- FLEXIBLE SPRINKLER HOSE FITTINGS FOR USE WITH COMMERCIAL SUSPENDED CEILING AND CLEAN ROOM CEILING -
|
|
- Ashlee Warren
- 5 years ago
- Views:
Transcription
1 Nov FLEXIBLE SPRINKLER HOSE FITTINGS FOR USE WITH COMMERCIAL SUSPENDED CEILING AND CLEAN ROOM CEILING - - FLEXIBLE SPRINKLER HOSE FITTINGS FOR USE IN DUCTS -
2 - WITH COMMERCIAL SUSPENDED CEILING AND CLEAN ROOM CEILING Certification FM Approvals
3 WITH CLEAN ROOM CEILING SFT TYPE SEUNGJIN s SFT is used for clean room piping system of semi-conductor factories (PDP, TFT-LCD and etc) such as Samsung and LG Electronics. The product is certificated by FM Approvals. Mould Reducer is welded on the hose. It should be used in combination with sprinkler for use clean room where mould-bar on the ceiling is connected.
4 WITH CLEAN ROOM CEILING SFT TYPE SFT Reducer and Nipple used for exclusive use of clean rooms are welded on the both edges of the flexible tube. Generally, it is used for clean room ceilings. The customers can choose one of the two Nipple types, the Union Type(Slip Nut Type) or Welded Nipple Type. It is designed for better safety of earthquake-proof facilities.
5 WITH CLEAN ROOM CEILING SFT TYPE (SJ-CR-XX-B2, SJ-CR-XX-B2)
6 WITH CLEAN ROOM CEILING SFT TYPE (SJ-CR-XX-B1) Model Rated Pressure, psi (Bar) Outlet NPT/BSPT in inch. Assembly length, ft(mm) Number of Bends Minimum Bend Radius in. (mm) k- Factor Equivalent Length of 1 in. Schedule 40 Pipe, ft / (m) SJ-CR-07-B1 175 (12,1) ½ 2.3 (700) 1 9 (230) (5,7) SJ-CR-10-B1 175 (12,1) ½ 3.3 (1000) 2 9 (230) (7.1) SJ-CR-12-B1 175 (12,1) ½ 3.9 (1200) 2 9 (230) ,3 (8) SJ-CR-15-B1 175 (12,1) ½ 4.9 (1500) 3 9 (230) ,7 (9.3) SJ-CR-18-B1 175 (12,1) ½ 5.9 (1800) 4 9 (230) ,5 (10,2) SJ-CR-07-B1 175 (12,1) ¾ 2.3 (700) 1 9 (230) 8 9,6 (2,9) SJ-CR-10-B1 175 (12,1) ¾ 3.3 (1000) 2 9 (230) 8 13,9 (4,4) SJ-CR-12-B1 175 (12,1) ¾ 3.9 (1200) 2 9 (230) 8 16,2 (4,9) SJ-CR-15-B1 175 (12,1) ¾ 4.9 (1500) 3 9 (230) 8 22,3 (6,8) SJ-CR-18-B1 175 (12,1) ¾ 5.9 (1800) 4 9 (230) 8 27,1 (8,3)
7 WITH CLEAN ROOM CEILING SFT TYPE (SJ-CR-XX-B2) Model Rated Pressure, psi Outlet NPT/BSPT in inch. Assembly length, ft(mm) Number of Bends Minimum Bend Radius in. (mm) k- Factor Equivalent Length of 1 in. Schedule 40 Pipe, ft / (m) SJ-CR-07-B2 175 (12,1) ½ 2.3 (700) 1 9 (230) (5,7) SJ-CR-10-B2 175 (12,1) ½ 3.3 (1000) 2 9 (230) (7.1) SJ-CR-12-B2 175 (12,1) ½ 3.9 (1175) 2 9 (230) ,3 (8) SJ-CR-15-B2 175 (12,1) ½ 4.9 (1500) 3 9 (230) ,7 (9.3) SJ-CR-18-B2 175 (12,1) ½ 5.9 (1800) 4 9 (230) ,5 (10,2) SJ-CR-07-B2 175 (12,1) ¾ 2.3 (700) 1 9 (230) 8 9,6 (2,9) SJ-CR-10-B2 175 (12,1) ¾ 3.3 (1000) 2 9 (230) 8 13,9 (4,4) SJ-CR-12-B2 175 (12,1) ¾ 3.9 (1200) 2 9 (230) 8 16,2 (4,9) SJ-CR-15-B2 175 (12,1) ¾ 4.9 (1500) 3 9 (230) 8 22,3 (6,8) SJ-CR-18-B2 175 (12,1) ¾ 5.9 (1800) 4 9 (230) 8 27,1 (8,3)
8 WITH CLEAN ROOM CEILING SFT TYPE (SJ-CR-XX-B1, SJ-CR-XX-B2) Model SJ-CR-XX-B2 SJ-CR-XX-B2 SJ : SEUNG JIN CR : Clean Room Description Flexible Hose Length : 07=700 mm(2.3ft) 10=1000 mm(3.3ft) 15=1500 mm(4.9ft) 12=1175 mm(3.9ft) 18=1800 mm(5.9ft) B2=Bracket 1 (Thin panel Model) B2=Bracket 2 (Thick Panel Model) Part Material Quantity Flexible Tube Mould Reducer STS304 1 STS304 1 Nipple STS304 or HR 1 Fitting STS304 or S10C 1 Nut STS304 or S10C 1 Band Ring STS304 2 Max Ambient Temp, F 225 F (107 C) Adapter STS304 2 O-Ring NBR 1 Working Pressure 175psi Bracket STS304 2 K-Factor 1/2" outlet 5.6 gpm 3/4" outlet 8.0 gpm Braid STS304 1 O-Ring NBR 1
9 WITH COMMERCIAL SUSPENDED CEILING SGP TYPE SEUNGJIN s SGP is used for commercial ceiling or clean room piping system of semiconductor factories. The product is also certificated by FM Approvals. Union Type(Slip Nut Type) There are two types of SEUNG JIN s SGP. One is Union Type(Slip Nut Type) and the other is Welded Reducer Type. Welded Reducer Type
10 WITH COMMERCIAL SUSPENDED CEILING SGT TYPE Instead of the reducer used for exclusive use clean rooms, this product is developed for use commercial ceiling. It is very easy to install and assemble the products in building and office. (1) SGP Union Type(Slip Nut Type) The customers can choose various shapes and materials(sts or HR etc.) of Reducers and Nipples.
11 WITH COMMERCIAL SUSPENDED CEILING (1) SGP Union Type(Slip Nut Type) Part Material Quantity Flexible Tube STS304 1 Reducer STS304 or HR 1 Nipple STS304 or HR 1 Fitting STS304 or S10C 2 Nut STS304 or S10C 2 O-Ring NBR 2 Braid STS304 1 Braid Ring STS304 2 Adapter STS304 2 Square Bar SPCC 1 Bracket L1 SPCC 1 SGP Union Type and Accessories Bracket S1 SPHC 2
12 - FLEXIBLE SPRINKLER HOSE WITH FITTINGS FOR USE WITH COMMERCIAL SUSPENDED CEILING - The above photos show the shape of the installed Flexible Sprinkler Drops on the ceiling.
13 WITH COMMERCIAL SUSPENDED CEILING (1) SGP Union Type(Slip Nut Type)
14 WITH COMMERCIAL SUSPENDED CEILING (2) SGP Welded Reducer Type Bushing(Wing Nut) Type Aluminum Connect Type There are two types of SGP Welded Reducer Type. One is Bushing(Wing Nut) Type and the other is Aluminum Connect Type.
15 WITH COMMERCIAL SUSPENDED CEILING (2) SGP Welded Reducer Type - Bushing(Wing Nut) Type Part Material Quantity Bushing (Wing Nut) S10C or Brass 1
16 WITH COMMERCIAL SUSPENDED CEILING (2) SGP Welded Reducer Type - Aluminum Connect Type Part Material Quantity AL Clean Connect AL O-Ring NBR 2
17 WITH COMMERCIAL SUSPENDED CEILING SGP Type (SPB-BXX-B1) Model Rated Pressure, psi (Bar) Outlet NPT/BSPT in inch. Assembly length, ft(mm) Number of Bends Minimum Bend Radius in. (mm) k- Factor Equivalent Length of 1 in. Schedule 40 Pipe, ft / (m) SPB-B700-B1 175 (12,1) ½ 2.3 (700) 1 9 (230) (5,7) SPB-B1000-B1 175 (12,1) ½ 3.3 (1000) 2 9 (230) (7.1) SPB-B1200-B1 175 (12,1) ½ 3.9 (1200) 2 9 (230) ,3 (8) SPB-B1500-B1 175 (12,1) ½ 4.9 (1500) 3 9 (230) ,7 (9.3) SPB-B1800-B1 175 (12,1) ½ 5.9 (1800) 4 9 (230) ,5 (10,2) SPB-B700-B1 175 (12,1) ¾ 2.3 (700) 1 9 (230) 8 9,6 (2,9) SPB-B1000-B1 175 (12,1) ¾ 3.3 (1000) 2 9 (230) 8 13,9 (4,4) SPB-B1200-B1 175 (12,1) ¾ 3.9 (1200) 2 9 (230) 8 16,2 (4,9) SPB-B1500-B1 175 (12,1) ¾ 4.9 (1500) 3 9 (230) 8 22,3 (6,8) SPB-B1800-B1 175 (12,1) ¾ 5.9 (1800) 4 9 (230) 8 27,1 (8,3)
18 WITH COMMERCIAL SUSPENDED CEILING SGP Type (SPB-BXX-B2) Model Rated Pressure, psi Outlet NPT/BSPT in ïnch. Assembly length, ft(mm) Number of Bends Minimum Bend Radius in. (mm) k- Factor Equivalent Length of 1 in. Schedule 40 Pipe, ft / (m) SPB-B700-B /2 2.3 (700) 1 9 (230) (5,7) SPB-B1000-B /2 3.3 (1000) 2 9 (230) (7.1) SPB-B1200-B /2 3.9 (1200) 2 9 (230) ,3 (8) SPB-B1500-B /2 4.9 (1500) 3 9 (230) ,7 (9.3) SPB-B1800-B /2 5.9 (1800) 4 9 (230) ,5 (10,2) SPB-B700-B /4 2.3 (700) 1 9 (230) 8 9,6 (2,9) SPB-B1000-B /4 3.3 (1000) 2 9 (230) 8 13,9 (4,4) SPB-B1200-B /4 3.9 (1200) 2 9 (230) 8 16,2 (4,9) SPB-B1500-B /4 4.9 (1500) 3 9 (230) 8 22,3 (6,8) SPB-B1800-B /4 5.9 (1800) 4 9 (230) 8 27,1 (8,3)
19 WITH COMMERCIAL SUSPENDED CEILING SGP Type(SJ-CR-XX-B2, SPB-BXX-B2) Model SPB-BXX-B2 SPB-BXX-B2 Description Flexible Hose Length : 07=700 mm(2.3ft) 10=1000 mm(3.3ft) 15=1500 mm(4.9ft) 12=1175 mm(3.9ft) 18=1800 mm(5.9ft) B2=Bracket 1 (Thin panel Model) B2=Bracket 2 (Thick Panel Model) Part Material Quantity Flexible Tube STS304 1 Reducer STS304 or HR 1 Nipple STS304 or HR 1 Fitting STS304 or S10C 2 Max Ambient Temp, F Working Pressure K-Factor 225 F (107 C) 175psi 1/2" outlet 5.6 gpm 3/4" outlet 8.0 gpm Nut STS304 or S10C 2 O-Ring NBR 2 Braid STS304 1 Braid Ring STS304 2 Adapter STS304 2
20 SEUNG JIN IND. CO., LTD IN DUCTS HUME DUCT TYPE In the process that the volatile gas, hydrogen chloride, or nitric acid gas made in the semi conductor factory, will be leaked outside through inner of the duct system, this product with sprinkler installed inner of duct is very helpful to extinguish the fire early. It is designed to protect sprinkler head from the corrosion resulted in hydrogen chloride, nitric acid gas and for the gas of inner duct not to leak into indoor.
21 IN DUCTS HUME DUCT TYPE (DUXX-YYYY)
22 - FLEXIBLE SPRINKLER HOSE WITH FITTINGS FOR USE WITH COMMERCIAL SUSPENDED CEILING - Union Type(SPB-BXX) UL/FM Model Rated Pressure, psi (Bar) Outlet NPT/BSPT in inch. Assembly length, ft(mm) Number of Bends Minimum Bend Radius in. (mm) k- Factor Equivalent Length of 1 in. Schedule 40 Pipe, ft / (m) SPB-B /2 2.3 (700) 1 9 (230) (5,7) SPB-B /2 3.3 (1000) 2 9 (230) (7.1) SPB-B /2 3.9 (1200) 2 9 (230) ,3 (8) SPB-B /2 4.9 (1500) 3 9 (230) ,7 (9.3) SPB-B /2 5.9 (1800) 4 9 (230) ,5 (10,2) SPB-B /4 2.3 (700) 1 9 (230) 8 9,6 (2,9) SPB-B /4 3.3 (1000) 2 9 (230) 8 13,9 (4,4) SPB-B /4 3.9 (1200) 2 9 (230) 8 16,2 (4,9) SPB-B /4 4.9 (1500) 3 9 (230) 8 22,3 (6,8) SPB-B /4 5.9 (1800) 4 9 (230) 8 27,1 (8,3)
23 IN DUCTS HUME DUCT TYPE (DUXX-YYYY) Model BSPT in. Hose Assembly length, ft(m) Equivalent Length of 1 in. Schedule 40 Pipe, ft(m) DUXX-YYYY 1/2 2.6(0.8) 8.3(2.6) DUXX-YYYY 1/2 8.5(2.6) 31.8(9.7) DUXX-YYYY 3/4 2.6(0.8) 7.6(2.3) DUXX-YYYY 3/4 8.5(2.6) 31.4(9.6) Model DUXX-YYYY DU : Duct Description XX : Product Length. 08 (08 is a 0.8m(2.6 ft) through 26 long hose assembly and26 is a 2.6m(8.5ft) long hose assembly. YYYY : Year and month manufactured. At present, the maximum length of a flexible sprinkler hose assembly including end connections, is up to 1.8 m(6 ft) by new FM Approvals policy. (FM Class Number 1637, Feb. 2010)
24 IN DUCTS HUME DUCT TYPE (DUXX-YYYY) Temperature Pressure Connection Minimum Bend Radius K-Factor 225 F (107 C) 175psi Inlet 1" Outlet 1/2" or 3/4" 8" 1/2" outlet 5.6 gpm 3/4" outlet 8.0 gpm Part Material Quantity Flexible Tube STS304 1 Nipple STS304 or HR 1 Nut STS304 or S10C 2 Fitting STS304 or S10C 2 Band-Ring STS304 2 Adapter STS304 2 Braid STS304 1 O-Ring NBR 2
Seung-Jin Ind.Co.,Ltd.
Seung-Jin Ind.Co.,Ltd www.seungjin.kr Contents Chapter 1 Introduction 1. About Seung-Jin Ind. Co. Ltd 2. Brief Company History 3. Organization Chart 4. Products Chapter 2 Flexible Sprinkler Hose With Fittings
More informationI-VICFLEX.AB3. Victaulic VicFlex Style AB3 Sprinkler Fittings for Surface Mount Applications WARNING WARNING INTRODUCTION
INSTALLATION INSTRUCTIONS I-VICFLEX. Victaulic VicFlex Style Sprinkler Fittings for Surface Mount Applications INTRODUCTION WARNING Read and understand all instructions before attempting to install any
More informationBROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF
BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS Product Submittal A PART OF Limited Warranty SprinkFLEX warrants that its products will be free from defects in materials and workmanship under normal conditions
More information10.85 VicFlex Sprinkler Fittings
Series AQB Braided Flexible Hose Assemblies VicFlex sprinkler fittings provide sprinkler installation on suspended ceiling grids, wood or metal stud/joist or hat furring channel hard-lid ceilings utilizing
More informationSeries SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies
Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies SprinkFLEX Stainless Steel Sprinkler Fittings connect the branch line to the sprinkler using a flexible stainless
More informationI-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS I-VICFLEX.AB Victaulic VicFlex Style AB Sprinkler Fitting for Hat Furring Channel Ceiling Systems Read and understand all instructions before attempting to install any Victaulic
More informationModel vkfd28b braided flexible sprinkler drops (lpcb approved)
Page 1 of 6 1. DESCRIPTION Viking Flexible Sprinkler Drops are a complete assembly intended for installation into commercial suspended ceilings with medium to heavy support tee bars as described in ASTM
More informationFLEXIBLE CORRUGATED TUBE
Back To The Natur e S O L A R S Y S T E M SPRINKLER SYSTEM B O I L E R FLEXIBLE CORRUGATED TUBE INSULATED SOLAR HOSES S Y S T E M w w w. k a s. c o m. t r SOLAR SYSTEM System Definition of Corrugated
More informationTechnical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A
Worldwide Contacts www.tyco-fire.com FASTFLEX Model YN25, YB25, and YB28 Flexible Hose Europe, Middle East, and Africa Only General Description The TYCO FASTFLEX Flexible Hose is a unique sprinkler drop
More informationWARNING. Flexible Hose AH2 With AB6 With AB6. AH2-CC With AB6 With AB6
INSTALLATION INSTRUCTIONS I-VICFLEX. Victaulic VicFlex Sprinkler Fittings: Style Bracket Assembly with Models V33,, or V40 Dry Sprinklers Read and understand all instructions before attempting to install
More informationMAGNETIC DRIVE PUMPS AMERICA S MOST VERSATILE LINE OF CENTRIFUGAL PUMPS THINK QUALITY...THINK DELIVERY...THINK PRICE
MAGNETIC DRIVE PUMPS AMERICA S MOST VERSATILE LINE OF CENTRIFUGAL PUMPS THINK QUALITY...THINK DELIVERY...THINK PRICE Seal-less Design Price Pump magnetically driven, seal-less pumps provide a leak-proof
More informationTRUST THE ORIGINAL. SUBMITTAL PACKAGE
TRUST THE ORIGINAL. SUBMITTAL PACKAGE FlexHead Brochure We invented the concept of flexible fire protection The FlexHead Advantage FLEXHEAD QUALITY Best corrosion resistance Made from 100% 04 stainless
More informationCooling Strip Model SPB
Cooling Strip Model SPB Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...
More informationVM99 TANK REPLACEMENT PARTS 1. COVER BOLT BOLT (4 REQ'D FOR 21-34), 1/4"-20 x 1" THERMAL CUT-OUT THERMAL TRIP PLUG
VM99 TANK REPLACEMENT PARTS 1. COVER BOLT BOLT (4 REQ'D FOR 21-34), 1/4"-20 x 1" 700300-013 2. THERMAL CUT-OUT 409560-001 THERMAL TRIP PLUG 409210-010 3. HEATER TERMINAL COVER VM99 2-4 HEATER TERMINAL
More informationPRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM
ANNEXUREIII D: FIRE PROTECTION SYSTEM SECTION ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM Supply, Installation, testing and commissioning of Analogue Addressable Fire Alarm Control panel with battery backup
More informationVictaulic VicFlex Sprinkler Fittings Series AH2 and AH2-CC Braided Flexible Hoses 10.85
Victaulic VicFlex Sprinkler Fittings Series H and H-CC Braided Flexible Hoses 0.8 Series H Series H-CC.0 PODUCT DESCIPTION vailable Sizes by Component Series H Braided Hose:,, 8, 0, "/90, 9, 9,, 80. Note:
More informationSUPPLY,INSTALLATION,TESTING AND COMMISSIONING OF SPRINKLER SYSTEM AND FIRE ALARM SYSTEM FOR AIR INDIA LIMITED AT SHAMSHABAD, HYDERABAD.
i 1 a SPRINKLER SYSTEM M S Pipes confirming to IS 1239 Pt - I Heavy grade with painting, suitable type of supports malleable srewed specials such as M S Reducers,Tees, elbows, flanges. Including cutting,
More informationIntegrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)
Integrated Process Solutions w w w. m k s i n s t. c o m Series 48 s heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100) Series 48 heaters have been designed for safety, flexibility, power conservation,
More informationSECTION FIRE PROTECTION
SECTION 15300 - FIRE PROTECTION PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR
More informationVictaulic Vic-Flex Sprinkler Fittings Series AH2 Braided Flexible Hose 10.85
Victaulic Vic-Flex Sprinkler Fittings Series H Braided Flexible Hose 0..0 PODUCT DESCIPTION vailable Sizes by Component Series H Braided Hose:,,, 0, "/0,, 0,, 0. Note: length includes adapter nipple and."/0
More informationTECHNICAL DATA. Wet 26a. February 22, 2009
February 22, 2009 Wet 26a 1. DESCRIPTION The Viking Alarm Check Valve serves as a check valve by trapping pressurized water above the clapper and preventing reverse flow from sprinkler piping. The valve
More informationInstalling Protectowire Linear Heat Detector
PROTECTOWIRE FireSystems 1. Purpose The purpose of this guide is to ensure coverage of the area to be protected in accordance with accepted fire protection principles and to assure uniform installations.
More informationB. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.
(816) 373-4878 U1208-01/FAI29-029 (573) 751-2624 SECTION 2 105 17 - SLEEVES AND SLEEVE SEALS FOR FIRE-SUPPRESSION PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the
More informationFight or Flee? Extinguisher Basics Extinguisher Use Extinguisher Placement and Spacing Hydrostatic Testing OSHA Requirements Test Your Knowledge
OSHA Requirements Fight or Flee? Extinguisher Basics Extinguisher Use Extinguisher Placement and Spacing Hydrostatic Testing OSHA Requirements Test Your Knowledge The requirements of this section apply
More informationSPRINKLER ALARM TECHNICAL DATA SPRINKLER ALARM MODEL - GA
SPRINKLER ALARM TECHNICAL DATA MODEL MOUNTING TYPE WATER WORKING PRESSURE CONNECTION GA Type-A & Type-B 17.5 Bar (250 PSI) Inlet : 3/4 BSPT (3/4 NPT) Drain : 1 BSPT (1 NPT) GONG DIAMETER 205mm (8 ) GONG
More informationB. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.
DIVISION 21 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, sleeves, escutcheons, seals, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS
More informationKRS data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet
KRS822-50 data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429
More informationSubchapter 7. General Industry Safety Orders Group 27. Fire Protection Article 157. Portable Fire Extinguishers. Return to index New query
This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or
More informationFlow Switches. Liquid Flow Switches. Mounting Methods
Liquid The flow of liquids in pipelines plays an important role in industry and commerce. Under most circumstances it is essential to know whether or not there is a flow in a pipeline, and to act upon
More informationHusky Diaphragm Pump Suction Kits
First choice when quality counts. Husky Diaphragm Pump Suction Kits H B E C A D COMPONENTS E F Air-Powered Pump Packages for a Variety of Fluid Containers 2-461 When it Comes to Suction Kit Packages We
More informationOCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters
1200 North Main Street Fostoria, OH 44830 Phone: 800-495-4525 Fax: 419-435-0842 A DIVISION OF www.fostoriaindustries.com OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters *EXCLUDING
More informationBasic Vehicle Fire Protection Manual
Basic Vehicle Fire Protection Manual Basic Vehicle Fire Protection Manual TABLE OF CONTENTS Introduction... 3 System Operation...... 5 Component Overview.... 7 Operator Controls Control Panel.........
More information5000TC Series Toroidal (Electrodeless) Conductivity Sensors. Specification. Overview. Features. Description /00 Page 1 of 8
TC Series Toroidal (Electrodeless) Conductivity Sensors Overview The Honeywell TC toroidal (electrodeless) conductivity sensor measures the conductivity of solutions from.2 to millisiemens/cm. The sensors
More informationVK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) TECHNICAL DATA
Page 1 of 5 1. DESCRIPTION The Viking VK3021 Quick Response Pendent Sprinkler is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design
More informationDIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES
DIVISION 21 FIRE SUPPRESSION PART 1 GENERAL 1.01 DESCRIPTION A. Provide UL listed, FM approved listed fire protection specialties or accessories as required by either the equipment manufacturer or the
More informationSettlement Agreement. Schedule 1: Covered Products
Settlement Agreement Schedule 1: Covered Products COVERED PRODUCT BRANDS BRASSCRAFT PLUMBSHOP PEERLESS SOLUTIONS MASTER PLUMBER COVERED PRODUCT CATEGORIES - WATER SUPPLIES SUPPLY STOPS WATER SUPPLY CONNECTORS
More informationSPRINKLERS TABLE OF CONTENTS
SPRINKLERS TABLE OF CONTENTS SECTION 21 13 13 WET PIPE SPRINKLER SYSTEMS SECTION 211313 - WET PIPE SPRINKLER SYSTEMS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract,
More information1 Exam Prep. Questions and Answers
1 Exam Prep NFPA 14: Standard for the Installation of Standpipe and Hose Systems Questions and Answers 1. According to the NFPA-14, class I standpipes shall be at least inches in size. A. 2" 1/2" C. 3"
More informationSwegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES
Swegon PACIFIC Integrated chilled beam PACIFIC CHILLED BEAM The PACIFIC is a high performance chilled beam for installation in false ceilings. Built-in flexibility, designed to meet the needs of today
More informationIntegrated Process Solutions. Series 49. Thermal Management System
w w w. m k s i n s t. c o m Integrated Process Solutions Series 49 Thermal Management System The COMPLETE THERMAL MANAGEMENT Solution Controller Heater User Interface Series 49 Thermal Management System
More informationTECHNICAL DATA OBSOLETE
October 10, 2008 Deluge Devices 281a 1. PRODUCT DESCRIPTION The Viking Model C-1 is a rate-of-rise releasing device for use on hydraulic and pneumatic release systems controlling operation of Viking deluge
More informationModel: FT110 Dishwasher
PARTS MANUAL HOBART FOOD EQUIPMENT CO., LTD Model: FT110 Dishwasher HOBART FOOD EQUIPMENT CO., LTD 2003-07-10 Table of Contents Page Description 2 Panels, Upper chamber and Tank 4 Control Box 6 Control
More informationCold water compact class HD 1.8/13 C Ed
Cold water compact class HD 1.8/13 C Ed Cold water pressure washer for daily commercial use. With compact dimensions, solid construction and excellent manueverability, this unit is one of the most versatile
More informationSpecialties Quality, Durability, Reliability. FIrE ProTECTIon
_specialties:pcsectiond_new 2/6/2012 4:46 PM Page -36 36 SECTIon Specialties Quality, Durability, Reliability FIrE ProTECTIon In addition to our plumbing business, LYNCAR has been a leading supplier to
More informationB. Related Sections: The following Sections contain requirements that relate to this Section.
SECTION 211313- FIRE-SUPPRESSION PIPING PART1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general prov1s1ons of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationA HEATER KIT With Diesel Engine Connection Fittings
A-12142 HEATER KIT With Diesel Engine Connection Fittings Figure 1 (General Layout and Parts I.D.) Page 1 of 6 Read these instructions and identify all components. Please retain these instructions for
More informationSCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL /
SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL 60202 fpeschulte@aol.com 847/866-7479 SPRINKLER PROTECTION BASICS: TYPES OF : SPRAY - standard response - quick response -
More informationQuick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Quick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING Technical leaflet Introduction QDV is a quick closing oil drain valve, designed particularly for draining oil from systems
More informationROTARY VANE VACUUM PUMPS Exploded View DuraVane Rotary Vane Pumps Oil-Lubricated RVL301HH
Exploded View Pumps RVL0HH 95 SOUTH WOODLAND AVENUE, MICHIGAN CITY, IN 0-57 Please visit our website at Page Number Reference TOLL-FREE: 888-95-5 TEL.: 9-8-0 FAX: 9-8-0 www.dekkervacuum.com DWG //05 RVL0HH
More informationstandard response/ quick response extended coverage
1. DESCRIPTION Viking Extended Coverage Adjustable Recessed Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry
More informationDISCONTINUED. Widespread Lavatory Faucet TL170DD RENESSE. Contents. Installation and Owner s Manual. English Español Français
0GU3026 2007.5 TL170DD Widespread Lavatory Faucet Installation and Owner s Manual RENESSE Español Français Contents Important Safeguards---------------1 Specifications -------------------------2 Before
More informationSECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM
PART 1 GENERAL 1.01 SUMMARY SECTION 15371 KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM A. Section Includes: A complete wet chemical automatic fire suppression system for the exhaust hood, including necessary
More informationStorage Sprinkler. Model LP-46 (SIN) V4603, K25, Standard Response Storage Upright Sprinkler, Patent Pending
FireLock LP-46 Low Pressure Storage Sprinkler This storage sprinkler was designed for controlling fires in single, double and multiple row rack storage of up to Cartoned, Unexpanded, Group A plastic commodities
More informationElectrical Mini Tank Water Heater anual, and Warranty nformation
Electrical Mini Tank Water Heater Installation uide, ser anual, and Warranty nformation Electrical Mini Tank Water Heater 2.6 Gals 2.6 IMPORTANT SAFETY INFORMATION A SAFETY VALVE MUST BE USED FOR PROPER
More informationFlow Switches. Liquid Flow Switches. Mounting Methods
Liquid The flow of liquids in pipelines plays an important role in industry and commerce. Under most circumstances it is essential to know whether or not there is a flow in a pipeline, and to act upon
More informationWayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No
SECTION 213113 - ELECTRIC-DRIVE, CENTRIFUGAL FIRE PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationKITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM
PART 1 GENERAL 1.01 SUMMARY SECTION 15371 KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM A. Section Includes: A complete automatic fire suppression system for the exhaust hood, including necessary accessories.
More informationNorth Hanover Township School District North Hanover Township, New Jersey
SECTION 211313 - WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipes, fittings, and specialties. 2. Fire-protection valves. 3. Fire-department connections. 4. Sprinklers.
More informationFireSystems PROTECTOWIRE. Installing Protectowire Linear Heat Detector
PROTECTOWIRE FireSystems Installing 1. Purpose The purpose of this guide is to ensure coverage of the area to be protected in accordance with accepted fire protection principles and to assure uniform installations.
More informationRepair Parts List DRYER MODEL NUMBER MDG51PDAWW. When requesting service or ordering parts, always provide the following information:
Repair Parts List DRYER MODEL NUMBER MDG51PDAWW When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description 2005
More information(EE1500, EE2000, EE2500, EE3000)
EE-Ti (EE1500, EE2000, EE2500, EE3000) Heat Pump (Mfg. 2010 Present) 15 26 3 11 12 1 BLUE WIRE RED WIRE YELLOW WIRE ORANGE WIRE These pressure switches are installed in the refrigerant line near the compressor
More informationQuick closing oil drain valve QDV
MAKING MODERN LIVING POSSIBLE Technical brochure Quick closing oil drain valve QDV www.danfoss.com/ir Introduction QDV is a quick closing oil drain valve, designed particularly for draining oil from systems
More informationExplosion Proof 160 W Class 1 & 2 Fluorescent UV Light With 4 Lamps - Class 1 Division 1
Explosion Proof 160 W Class 1 & 2 Fluorescent UV Light With 4 Lamps - Class 1 Division 1 Part #: EPL-48-4L-UV Page: 1 Made in the USA The Larson Electronics EPL-48-4L-UV 160 Watt Explosion Proof UV Fluorescent
More informationMIG-FLEX EXTENSIBLE, FLEXIBLE METAL HOSES
A MEMBER OF EURO-QUALIFLEX MIG-FLEX EXTENSIBLE, FLEXIBLE METAL HOSES MIG-GAS MIG-SU Scan this QR Code www.ayvaz.com MIG-GAS (NATURAL GAS CONNECTIONS) Application Areas Natural gas applications Kitchen
More informationSTANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA
Page 1 of 6 1. DESCRIPTION Viking Standard/Quick Response Extended Coverage Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers
More informationMicro/Ultra Filtration System StamoClean CAT 430
Technical Information TI 338C/07/en/10.03 No. 51508729 Micro/Ultra Filtration System StamoClean CAT 430 Long-term Stable Membrane Filter for Immersion Operation in Activated Sludge Basins or Wastewater
More informationKidde Nitrogen Inert Gas Clean Agent Fire Suppression System
1. GENERAL 1.1 INTENT OF SPECIFICATIONS A. This specification details the requirements for an engineered inert gas fire suppression system Model Kidde Nitrogen. These requirements, combined with good engineering
More informationSTORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop
STORED PRESSURE 50, 125/150 lb. Stored Pressure These commercial stored pressure extinguishers are available in a choice of two sizes and three chemical options. The carriage design on both sizes provides
More informationSECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS
SECTION 15501 WET AUTOMATIC FIRE SPRINKLER SYSTEMS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Wet automatic fire sprinkler systems including fire pump, fire pump controller, alarms, safety devices,
More informationSPEAKMAN SAFETY PRODUCTS Installation Instructions SEF-TW
SPEAKMAN SAFETY PRODUCTS Installation Instructions SEF-TW DESCRIPTION The SEF-TW is a thermostatic mixing valve kit for supplying tepid water to the Speakman SEF line of Eyewash Faucets. The thermostatic
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS STEAM BOOSTER FOR DISHWASHERS #150-1 ML-110451 #180-1 ML-18599 #260 ML-18600 (0 to 20 PSI) ML-31683 (21 to 50 PSI) #320 ML-18601 (0 to 20 PSI) ML-31684 (21 to 50 PSI) #380
More informationVDC. Wireless AC Voltage Detection Sensor. The Leader in Low-Cost, Remote Monitoring Solutions. General Description. Monnit Sensor Core Specifications
1-50 The Leader in Low-Cost, Remote Monitoring Solutions Wireless AC Voltage Detection Sensor VDC 1-50 VOLT General Description The wireless AC voltage detection sensor can interface with other devices
More informationWest District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8
City of Ottawa Project No. CR006230 Page 1 of 8 PART 1 - GENERAL 1.1 Reference Standards.1 Conform to the following:.1 Provincial and municipal building and fire regulations as approved by Provincial Fire
More informationUSER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS
USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS APPLICATION INDEECO Explosion proof Electric Immersion Heaters for Hazardous Locations are ccsaus Certified for use in areas (external
More informationToroidal (Electrodeless) Conductivity Sensors Series 5000TC Specifications
Toroidal (Electrodeless) Conductivity Sensors Series TC Specifications 7-82-3-37 June Overview The Honeywell TC toroidal (electrodeless) conductivity sensor measures the conductivity of solutions from.2
More information1 Exam Prep NFPA 14 Stand Pipe Systems Questions and Answers (Plumbing Contractors)
1 Exam Prep NFPA 14 Stand Pipe Systems Questions and Answers (Plumbing Contractors) 1. What is the minimum diameter for a non-hydraulically calculated Class III fire standpipe that is part of a combined
More informationSECTION WET-PIPE SPRINKLER SYSTEMS
SECTION 21 1300 S PART 1 -GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationExplosion Proof Emergency Fluorescent Light Combination - Dimmable Ballast - C1D1-2 T8 lamps - 4'
Explosion Proof Emergency Fluorescent Light Combination - Dimmable Ballast - C1D1-2 T8 lamps - 4' Part #: EPL-EMG-48-2L-T8-D Made in the USA The Larson Electronics EPL-EMG-48-2l-T8-D Explosion Proof Emergency
More informationQUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.
Page 1 of 6 1. DESCRIPTION Viking Quick Response Extra-Large Orifice Pendent Sprinkler VK377 is a thermosensitive glass bulb spray sprinkler available in several different finishes and temperature ratings
More informationTANKER & STORAGE TANK PRODUCTS
Dry Bulk Dixon Dry Bulk products are designed for use with bulk trailers and truck blowers for the pneumatic transfer of dry bulk commodities such as powders, grains and plastic pellets. Other industrial
More informationSECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.
SECTION 15481 COMPRESSED AIR SYSTEM PART 1 - GENERAL 1.1 SECTION INCLUDES A. Pipe and pipe fittings, including valves, unions and couplings. B. Air compressor. C. After cooler. D. Refrigerated air dryer.
More informationMATRIX 2 - COD REV.02
COD. 0 REV. 0 - COD.0 - REV.0 - COD.0 - REV.0 TABLE Mod. MN/DE FEET M D0X ASSEMBLY CHASSIS DUO/ 0 FITTING / 0 GASKET D X X 0.0 RUBBER-HOLDER / 00 SCREW TCEI MX 00 RIGHT/LEFT LATERAL SIDE 0LL REAR BODY
More informationR7521SS COLORS/FINISHES. Stainless Steel 21 15/16" 1 3/16" 8 5/64" 1 25/32" 2 1/8" 23 5/8" Max. 1 3/8" G1/2" Female
MODERN SIDE LEVER STAINLESS STEEL PRO PULL-DOWN KITCHEN FAUCET R7521SS FEATURES Metal lever Dual spray modes Handspray locks into spray mode Stainless steel construction 1 5/8 max. installation depth on
More informationCITY OF MADISON FIRE DEPARTMENT (MFD) FIRE PROTECTION SYSTEM PLANS
CITY OF MADISON FIRE DEPARTMENT (MFD) FIRE PROTECTION SYSTEM PLANS Fire Protection Systems includes the following: Alternate Fire Suppression Systems Atrium Fire Protection Systems Automatic Fire Sprinkler
More informationSECTION METERS AND GAGES FOR HVAC PIPING
SECTION 23 0519 METERS AND GAGES FOR HVAC PIPING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Thermometers. 2. Gages. 3. Test plugs. 4. Thermowells. 1.2 SUBMITTALS A. Product Data: For each type
More informationMAIN FEATURES ADVANTAGES BENEFITS BOSS TRANSFORMER COMBI HF 110 CHEMICAL AND PHYSICAL FEATURES PACKAGING FEATURES
BOSS TRANSFORMER COMBI HF 110 Power flushing pump with antacid vertical axis. Suitable for domestic and medium dimensions systems. Practical trolley design with 110 litres tank. COD. 301301006 CHEMICAL
More informationA sprinkler operates automatically when the heat-actuated element is heated to, or above, its thermal rating.
Control / Residential / Suppression Mode Sprinklers Automatic sprinkler protection is recommended for industrial and other buildings having combustible construction or combustible occupancies. There are
More informationMATRIX 2 - COD REV.00
COD. 0 REV. 00 - COD.0 - REV.00 - COD.0 - REV.00 TABLE Mod. MN/DE FEET M D0X ASSEMBLY CHASSIS DUO/ 0 FITTING / 0 GASKET D X X 0.0 RUBBER-HOLDER / 00 SCREW TCEI MX 00 RIGHT/LEFT LATERAL SIDE 0LL REAR BODY
More informationINSTALLATION INSTRUCTIONS
,1,_2008 Lennox Industries Inc, Dallas, Texas, USA INSTALLATION INSTRUCTIONS CR33 Series Coils EVAPORATOR COILS _ Technical 505,056M LL.L[ Publications 04108 Litho U.S.A. Supersedes 05/05 CR33 Series Coils...
More informationADDITIONAL PRODUCTS 65
ADDITIONAL PRODUCTS 65 ADDITIONAL PRODUCTS Pictorial Table of Contents Model FastFlex Flexible Sprinkler Hose Page 67 Sprinkler & Valves Product Overview Page 72 Model UFBX Flexible Hoses Pages 68-69 Figure
More informationFIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.
15500 - FIRE PROTECTION PART I DESIGN GUIDELINES A. General 1. Vertical fire pumps shall not be used at the University. 2. coupling piping shall be permitted for sprinkler and standpipe systems only. B.
More informationAKOCABLE Heating Cable Solutions Electrical Tracing
AKOCABLE Heating Cable Solutions Electrical Tracing www.ako.com AKOCABLE HEATING CABLE TECHNOLOGIES Mineral insulation Series type heating cable Used for high temperature maintenance and/or exposure Fluoropolymer
More informationGAS FLOODING SYSTEM FOR CIFF AT BASEMENT
CONSTRUCTION OF BUILDINGS FOR LABORATORIES AND ASSOCIATED FACILITIES INSTEM BANGALORE SCHEDULE OF QUANTITIES FOR (EQUIPMENT ROOM 3 & 4) Sl.No. Description Unit Quantity Rate (in INR) in figure HFC-227ea
More informationTECHNICAL INSTRUCTIONS FOR AFTER SALES ULTRA ELECTRIC PASTA COOKER
TECHNICAL INSTRUCTIONS FOR AFTER SALES ULTRA ELECTRIC PASTA COOKER ULTRA ELECTRIC PASTA COOKER 1. ELECTRIC DIAGRAMS...3 1.1 PASTA COOKER...3 1.2 OPTION AUTOMATIC LIFTING...4 2. HYDRAULIC CIRCUITS...5 2.1
More informationR7520SS COLORS/FINISHES. Stainless Steel 16 9/16" 7 15/16"
MODERN SIDE LEVER STAINLESS STEEL PULL-DOWN KITCHEN FAUCET R7520SS FEATURES Metal lever only Dual spray modes Stainless steel construction 1 7/8 max. installation depth on deck Ceramic disc control cartridge
More informationUNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1
GENERAL: 1. All fire protection systems shall be installed in accordance with the International Fire Code and applicable NFPA standards. This guideline provides additional requirements for the design and
More informationPage 1 of 7. Form No. F_ Rev Replaces Form No. F_ Rev 17.1 (added 205deg version)
Page 1 of 7 1. DESCRIPTION Viking Freedom Residential Concealed Horizontal Sidewall Sprinkler VK480 is a small high-sensitivity solder link and lever residential sprinkler designed for installation on
More information4-11/16 Square Boxes. With Knockouts. Knockout Description Sides Ends Bottom. Catalog Number (Universal No.) Depth (inches) Wiring Cubic Inch Capacity
4-11/16 Square Boxes With Knockouts Knockout Sides Ends Bottom Commercial Products 4SJ-3/4 29.5 87.0/ 39.46 1-1/2 Deep, Welded COMMERCIAL PRODUCTS: SWITCH AND OUTLET BOXES AND COVERS 1-1/2 Deep, Welded
More informationReference Guide 2.1. Certificate Number
SAFE Reference Guide 2.1 This reference guide provides general information for the installation, servicing, and maintaining of a Linear Heat Detection System. For more detail, please refer to the Installation
More informationInstantaneous Oil-Fired Water Heater. Installation Manual OM-148. (Type B)
Instantaneous Oil-Fired Water Heater Installation Manual MODEL OM-148 (Type B) IMPORTANT THIS APPLIANCE SHOULD BE INSTALLED BY A LICENSED, AUTHORIZED PERSON(S) DUE TO THE NECESSITY OF MAKING ELECTRICAL,
More information