Product Data. S UTEC ignition control and fan timer board provide. S S Cabinet features an insulated enclosure for the burner

Similar documents
Product Data. 367AAN Low --- Boy Oil Furnace Input Capacities: 70,000 thru 154,000 BTUH Series E 367AAN FEATURES/BENEFITS

Product Data. 58CMA MULTIPOISE OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES CMA FEATURES/BENEFITS

Product Data 58CMA FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data 369AAN FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data. 58VLR LOW --- BOY OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES VLR FEATURES/BENEFITS

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data 58VMR FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data. 58CMA Multipoise Oil Furnace. Series 120 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. 58CMA Multipoise Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. S Unit may also be sidewall vented with an approved A S OVM units equipped with ECM 2.3 Variable Speed

Product Data. CBLAAA LOW-BOY OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES 140

Product Data. S Unit may also be sidewall vented with an approved A S OVL units equipped with optional ECM 2.3 Variable

Product Data OBM/OVM. MULTIPOISE OIL FURNACE INPUT CAPACITIES 70,000 thru 154,000 BTUH THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data. 58RAV High-Efficiency Downflow/Horizontal Induced-Combustion Gas Furnace. 80% AFUE At Budget Price

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140, 150

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 160

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. S QuieTecht noise reduction system. S SmartEvapt -Humidity control when using a Thermidistat Control

Product Data STANDARD FEATURES

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

Product Data. S HYBRID HEAT Dual Fuel System compatible S All models are chimney friendly when used with accessory vent kit

Product Data. S ECM Blower Motor included S QuieTecht noise reduction system S SmartEvapt Humidity control when using a Thermidistatt Control

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace. Series 120 Input Capacities: 40,000 thru 135,000 Btuh

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace Series 131 Input Capacities: 40,000 thru 120,000 Btuh

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM range

Product Data. 58WAV WeatherMaker 8000 Energy-Efficient Deluxe Upflow Furnace. Series 150 and 160 Input Capacities: 45,000 thru 155,000 Btuh

Product Data. 340AAV 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Sizes 040 thru 140

58CTA/CTX PERFORMANCE 80 TWO --- STAGE WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

395CAV Sizes 045 thru 155 Series H and J

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Deluxe Upflow Furnace

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE

TECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C)

Product Data. 58CVA/CVX INFINITY 80 VARIABLE SPEED 4---WAY MULTIPOISE GAS FURNACE Input Capacities: 70,000 thru 155,000 Btuh Series 160

Product Data. 58GFA High-Efficiency Induced-Combustion Upflow Furnace. Heating Inputs: 65, ,000 Btuh

PREMIUM OIL Furnaces. Variable Speed Option. Up to 87.5% Efficiency Optional Cooling Up to 4 Tons High-Grade Stainless Steel Heat Exchanger FEATURING

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

Wt. Lbs Model Number (BTUH) Hz

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Cooling Capacity CFM in. w.c. (125 Pa)

Product Data. 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58TUA WeatherMaker Speed High-Efficiency Upflow Furnace. Input Capacities: 40,000 thru 135,000 Btuh

TECHNICAL SPECIFICATIONS

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE 3 -PASS PRIMARY HEAT EXCHANGERS FLOW -THROUGH SECONDARY HEAT EXCHANGERS MONOPORT INSHOT BURNERS

TECHNICAL SPECIFICATIONS

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

Model PG9MAB MULTIPOISE CONDENSING GAS FURNACE SS-PG9MAB-01. Time Roman FEATURES. burners seldom, if ever, needs cleaning.

Product Data. Comfort Heatt technology, the ultimate in heating comfort...

TSTAT0201CW Recommended (sold separately)

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

MERIT SERIES Downflow

Product Data. 58STA/STX 4-WAY MULTIPOISE INDUCED-COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh THE CARRIER 58STA/STX GAS FURNACE

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

Product Data. IdealComfortt technology, the ultimate in heating comfort...

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

ELITE SERIES Downflow - High Efficiency Blower Motor

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Product Data. 59TP5A Performance Boost Two---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

Product Data. 40MBDQ Ducted Slim Ductless System Sizes 09 to 58 INDUSTRY LEADING FEATURES / BENEFITS TABLE OF CONTENTS

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL SPECIFICATIONS

TSTAT0101SC Recommended (order separately)

8+* Bulletin No November 1997

Product Data. 58MXA Deluxe 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. Series 111 Input Capacities: 40,000 thru 120,000 Btuh

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

Product Data. 59SP5A Performance Boost, Single---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

installation, start-up, and operating instructions

Product Data. 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace. Series 121 Input Capacities: 40,000 thru 120,000 Btuh

Product Data PF4MNP FAN COIL SIZES 018 THRU 060 STANDARD FEATURES AIR HANDLER TECHNOLOGY AT ITS FINEST

Installation, Start-Up, and Operating Instructions For Sizes , Series 111

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

RE9X Series Downflow, Upflow Electric Furnaces

Product Data. 925SA PREFERREDt SERIES SINGLE -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES A LIMITED WARRANTY*

G6RC Series TECHNICAL SPECIFICATIONS

G34M Bulletin #69/ August 2003

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MVC / 38MVC 40MVQ / 38MVQ High---Wall Duct Free Split System Sizes 009 to 024

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B

Indiana WX Oil Furnace Inspection Guide

THE WALL-MOUNT AIR CONDITIONERS (50HZ)

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

350MAV HIGHLY-EFFICIENT 4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE. Sizes 040 thru 140 Series D. Form No. PDS 350M.40.

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

Downflow/Horizontal Right Induced Draft Gas Furnace

96.7 THE NEW GENERATION OF OIL-FIRED WARM AIR FURNACES + COMFORTABLE + PERFORMANCE + ECONOMICAL OPERATION + EASE OF MAINTENANCE + VERSATILE AFUE UP TO

Transcription:

LOW --- BOY OIL FURNAE INPUT RATE: 70,000 thru 154,000 BTUH ERIE 10 Product Data THE LATET IN OIL FURNAE TEHNOLOGY A0666 The model combines high efficiency and quiet operation with oil heating technology. The is available in sizes. Each size can be fired at 3 different rates by a simple nozzle change. Unit 105 covers input ranges from 70,000 to 105,000 Btuh. Unit 10 covers input ranges from 119,000 to 154,000 Btuh. The furnace design is a low -boy style for upflow applications where overhead space is limited. The components of the are the finest in the industry. The unit uses a Riello oil burner with a UTE fan timer board. The is a standard part of a quality -built home. This high efficiency furnace will provide years of quality service to home builders and homeowners alike. As with other arrier furnaces, this model is designed to work as part of a total home comfort system which includes elements for cooling, air cleaning, humidification, ventilation, and zoning. This unit is not approved for use in mobile home installations. FEATURE/BENEFIT Riello Oil Burner and UTE ontrols High quality Riello oil burner allows safe and efficient combustion of oil. UTE ignition control and fan timer board provide reliable operation and easy connection of thermostat and accessory wiring. asing Made of 18 -gauge painted steel for years of durability. abinet features an insulated enclosure for the burner and controls. Insulation and oundproofing Unique sound trap along with insulated walls efficiently capture most combustion noise and vibration make this unit one of the quietest on the market. Flue silence baffle ensures quiet operation. ombustion Products Venting Rear flue outlet. Unit may be vented using Type L vent material and a factory -built metal or masonry chimney. Unit may also be sidewall vented with an approved power venter. Adjustable Blower peed 4 -speed blower for precise airflow selection of heating or cooling operation. onstant Low-peed Blower witch Allows continual low -speed air circulation through the home to maximize comfort while maintaining efficiency. ombustion hamber/heat Exchanger ertifications Air is constantly filtered and stagnant air is avoided. This option can be controlled by the homeowner. omposed mainly of stainless and aluminized steel, the unique combination combustion chamber/heat exchanger resists corrosion, overheating, and deterioration. Heat transfer properties make it highly efficient. All seams are tightly welded for leak -free operation. unit is A certified. The efficiency is AHRI efficiency rating certified. 1

UNUED LEAD 3 1 3 4 5 N 6 E H A O O E N O A T L T H U M 7 X ON 1 G W R Y A96369 OMBUTION HAMBER/ HEAT EXHANGER ONTROL ENTER A96370 OIL BURNER A06115 MODEL NUMBER NOMENLATURE 105 10 1 Riello Burner Low --- Boy Oil Furnace ooling ize Airflow (Nominal 400 FM per 1,000 Btuh ooling) 1 --- 100 FM Input apacity 105 --- 70,000 Btuh with 0.40 gph nozzle 91,000 Btuh with 0.50 gph nozzle 105,000 Btuh with 0.65 gph nozzle 10 --- 119,000 Btuh with 0.75 gph nozzle 140,000 Btuh with 0.85 gph nozzle 154,000 Btuh with 1.00 gph nozzle eries Always Ask For U Use of the AHRI ertified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.

UNUED LEAD 3 1 3 E ON A O T L 4 5 N 6 H UM 7 X ON 1 5 6 8 7 9 10 4 3 11 1 H E G W R Y 1 14 13 A9681 1. Heavy -duty blower circulates air across the heat exchanger to transfer heat into the home.. Access door to air filters and blower. 3. Air filters. 4. Unique silencer system controls combustion noise. 5. Return -air plenum. 6. tainless steel combustion chamber. 7. Heat exchanger designed and shaped to efficiently transfer heat from furnace into the home. 8. upply -air plenum. 9. Fully insulated internal walls to minimize heat loss. 10. High limit control to prevent overtemperature. 11. Manual switch to allow user control of constant low -speed blower operation. 1. Adjustable electronic fan timer control (inside) has low voltage electrical terminal strip for easy connection of thermostat, cooling control, electronic air cleaner, and humidifier. 13. Aesthetic removable cover. Hides and protects burner and controls. 14. High -performance oil burner. 3

LEARANE TO OMBUTIBLE UNIT APPLIATION LOW --- BOY Furnace 1 IDE upply Plenum and Warm---Air Duct Within 6 Ft of Furnace 1 BAK ervice learance 19 Furnace asing or Plenum TOP Horizontal Warm---Air Duct Within 6 Ft of Furnace BOTTOM* 0 FLUE PIPE Horizontally or Below Pipe 4 Vertically Above Pipe 9 FRONT 8 *Floor may be combustible. NOTE: Adequate service clearance should be provided over and above these dimensions as required. PHYIAL DATA UNIT IZE 105---1 10---0 INPUT (BTUH) 70,000 91,000 105,000 119,000 140,000 154,000 HEATING APAITY* 57,000 74,000 85,000 97,000 115,000 16,000 NOZZLE 0.40 --- 70A 0.50 --- 70W 0.65 --- 70W 0.75 --- 70B 0.85 --- 70W 1.00 --- 70W FIRING RATE (GPH){ 0.50 0.65 0.75 0.85 1.00 1.10 AFUE% 80.5 80.5 80.5 80.0 80.0 80.0 OIL PUMP TAGE/PREURE (PIG) 1/160 1/170 1/135 1/130 1/140 1/15 HEATING TEMP RIE _F 55---85 55---85 55---85 55---85 55---85 55---85 OOLING FM @ 0.5---IN. W TATI PREURE 150 150 150 1865 1865 1865 HEATING FM @ 0.---IN. W TATI PREURE 840 1130 145 1555 1890 080 REOMMENDED HEATING BLOWER PEED Med --- Low Med --- High High Med --- Low Med --- Low High HIPPING WEIGHT (LB) 35 35 35 60 60 60 BURNER MODEL (3450 RPM) 40 --- F3 40 --- F3 * apacity and AFUE in accordance with U.. Government DOE test procedures. { For rating purposes only. haded cells are as factory shipped. 40 --- F3 40 --- F5 40 --- F5 40 --- F5 4

PERFORMANE DATA UNIT IZE 105---1 10---0 DIRET---DRIVE MOTOR Hp (P) 1/3 3/4 MOTOR FULL LOAD AMP 6. 9.5 RPM (Nominal) --- PEED 1075---4 1075---4 BLOWER WHEEL DIAMETER X WIDTH (In.) 10 x 8 1 x 10 FILTER IZE (In.) --- (Disposable) () 1 x 0 x 1 () 16 x 0 x 1 AIR DELIVERY -FM (WITH FILTER) UNIT IZE BLOWER MOTOR HP 105---1 1/3 P 10---0 3/4 P EXTERNAL TATI PREURE (In. wc) PEED 0. 0.3 0.4 0.5 0.6 0.7 0.8 0.9 High 145 1350 1305 150 1170 1030 95 805 Med --- High 1130 1045 1000 950 885 80 745 670 Med --- Low 840 810 770 740 685 635 580 500 Low 75 730 740 745 730 715 690 665 High 080 040 1965 1865 1700 1575 1475 1335 Med --- High 1890 1860 1770 1675 1550 1450 1330 115 Med --- Low 1555 1475 1395 130 110 1135 1050 940 Low 10 1165 1080 1000 95 855 780 655 ELETRIAL DATA UNIT IZE 105---1 10---0 UNIT VOLT --- HERTZ --- PHAE 115 --- 60 --- 1 115 --- 60 --- 1 OPERATING VOLTAGE RANGE (Min---Max)* 104 --- 13 104 --- 13 MAXIMUM UNIT AMP 1. 15.7 MINIMUM WIRE IZE (AWG) 14 1 MAXIMUM WIRE LENGTH (Ft){ 6 6 MAXIMUM FUE IZE OR KT BKR (Amps)} 15 0 TRANFORMER (4v) 40va 40va EXTERNAL ONTROL POWER AVAILABLE Heating 40va 40va ooling 30va 30va AIR ONDITIONING RELAY tandard tandard * Permissible limits of the voltage range at which the unit will operate satisfactorily. { Length is measured one way along wire path between unit and service panel for maximum % voltage drop. } Time---delay fuse type is recommended. 5

DIMENION 1 1 4 0" 0" 0" VENT ONN D 3" E 10" B A A98009 DIMENION (IN.) UNIT DIMENION RETURN UPPLY UNIT FLUE HEIGHT OPENING OPENING VENT WIDTH DEPTH HEIGHT IZE ONN A B D E 105---1 1---1/4 53---3/4 31---1/ 6---1/ 0 0 5 10---0 1---1/4 60---5/3 34---3/4 8---11/3 4 6 6

AEORIE ONTROL: THERMOTAT AND ZONING A9743 ENERGY/HEAT REOVERY VENTILATOR A94336 ELETRONI OR MEHANIAL AIR LEANER A97380 HUMIDIFIER A91365 Available in programmable and non---programmable models, arrier thermostats maintain a constant, comfortable temperature level in the home. For the ultimate in home comfort, arrier s, 4, and 8---zone systems allow temperature control of individual zones of the home. This is accomplished through a series of electronic dampers and remote room sensors. The 4---zone system is shown. arrier s energy or heat recovery ventilators exhaust stale indoor air and provide fresh outdoor air to the home while minimizing heat loss and humidity level. Especially useful for today s tighter constructed houses. Energy recovery ventilator is shown. leans the air of smoke, dirt, and many pollens commonly found. aves decorating and cleaning expenses by keeping carpets, furniture, and drapes cleaner. Electronic air cleaner is shown. By adding moisture to winter---dry air, arrier humidifier can often improve comfort and keeps woodwork, wallpaper, and paint in better condition. Moisturizing household air also helps to retain normal body heat and provides comfort at lower temperatures. KLABV001DET Blocked Vent hutoff Kit FURNAE AEORIE TP --- PRH01 --- A T --- PA01 T--- PHP01 TP --- NRH01 --- A T --- NA01 T --- NHP01 ZONEKIT01--- B ZONE4KIT01--- B ZONE8KIT01--- B HUMBP31 HUMABP31 HUMLBP317 HUMALBP317 HUMLFP1318 HUMALFP1318 HRVHA1100 PROGRAMMABLE THERMOTAT ELETION Thermostat, Auto changeover 7--- Day Programmable, F/, 3 --- tage Heat/ --- tage ool, Relative Humidity Thermostat, Auto hangeover, 5--- --- Day Programmable, F/, 1 --- tage Heat/1 --- tage ool Thermostat, Auto hangeover, 5--- --- Day Programmable, F/, --- tage Heat/1 --- tage ool NON---PROGRAMMABLE THERMOTAT ELETION Thermostat, Auto hangeover, Non--- Programmable, F/, 3 --- tage Heat/ --- tage ool, Relative Humidity Thermostat, Auto hangeover, Non--- Programmable, F/, 1 --- tage Heat/1 --- tage ool Thermostat, Auto hangeover, Non--- Programmable, F/, --- tage Heat/1 --- tage ool ZONING ONTROL ELETION omfort Zone II--- B --- Zone Kit/Temperature and Humidity ontrol omfort Zone II--- B --- 4 Zone Kit/Temperature and Humidity ontrol omfort Zone II--- B --- 8 Zone Kit/Temperature and Humidity ontrol HEALTHY HOME OLUTION Humidifier --- 1 g./day, 4V tandard, mall Bypass Humidifier --- 1 g./day, 4V Automatic, mall Bypass Humidifier --- 17 g./day, 4V tandard, Large Bypass Humidifier --- 17 g./day, 4V Automatic, Large Bypass Humidifier --- 18 g./day, 4V tandard, Fan Powered Humidifier --- 18 g./day, 4V Automatic, Fan Powered Heat Recovery Ventilator --- mall Horizontal Unit, 100 FM 7

AEORIE (ONTINUED) HRVVA1100 Heat Recovery Ventilator --- mall Vertical Unit, 100 FM HRVLHA1150 Heat Recovery Ventilator --- Large Horizontal Unit, 150 FM HRVLHA150 Heat Recovery Ventilator --- Large Horizontal Unit, 50 FM HRVVU1150 Heat Recovery Ventilator --- mall Vertical Unit, 150 FM HRVVU100 Heat Recovery Ventilator --- mall Vertical Unit, 00 FM HRVLVU1150 Heat Recovery Ventilator --- Large Vertical Unit, 150 FM HRVLVU100 Heat Recovery Ventilator --- Large Vertical Unit, 00 FM HRVLVU1330 Heat Recovery Ventilator --- Large Vertical Unit, 330 FM ERVHA1100 Energy Recovery Ventilator --- mall Horizontal Unit, 100 FM ERVVA1100 Energy Recovery Ventilator --- mall Vertical Unit, 100 FM ERVLHU1150 Energy Recovery Ventilator --- Large Horizontal Unit, 150 FM ERVLHU100 Energy Recovery Ventilator --- Large Horizontal Unit, 00 FM EZXAB1016 Media Filter abinet --- 1600 FM (Replacement Filter: EXPXXFIL0016) EZXAB100 Media Filter abinet --- 000 FM (Replacement Filter: EXPXXFIL000) TYPIAL INTALLATION AIR ONDITIONER OR HEAT PUMP UPPLY-AIR DUT RETURN-AIR DUT OIL TANK A/ OIL HIMNEY LOW-BOY OIL FURNAE FLUE PIPE AIR FLOW A98010 opyright 010 arrier orp. 7310 W. Morris t. Indianapolis, IN 4631 Printed in U..A. Edition Date: 11/10 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. atalog No: ---5PD Replaces: ---4PD 8