WATER TEMPERATURE CONTROL SYSTEMS

Similar documents
MODEL 270-LF ECO-MIX THERMOSTATIC MIXING LEAD FREE THERMOSTATIC POINT OF USE MIXING VALVE. Submittal Data Sheet S-827-LF February 2013

CLASSIC HIGH LOW MANIFOLD SYSTEMS

COMPLETE WATER TEMPERATURE CONTROL SYSTEM

NEW GENERATION HIGH LOW SYSTEMS

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

Submittal S-NV-150-LF-M November, 2018 MEGATRON MODEL NV-150-LF DIGITAL TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

Submittal S-NV-200-LF-M DIGITAL TEMPERATURE CONTROL STATION. Valve assembly is ASSE 1017 Certified. Valve assembly is cupc Certified

Mixing Safety and Performance

Hose Stations. Leonard THS Thermostatic and SW/CW Manual Hose Stations

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION MEGATRON MODEL 10NB-LF 4 HOT & COLD INLETS 4 MIXED OUTLET 2 RETURN PIPING

WALL MOUNTED SHOWER SYSTEMS

Wall Mounted Shower Systems

INSTALLATION ADJUSTMENT SERVICE

HL45, HL80 Thermostatic High-Low Valves

TMV45 & TMV80 Standard Thermostatic Mixing Valves

INSTALLATION ADJUSTMENT SERVICE

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA)

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

OUTLET HOT INLET COLD INLET INSTALLATION

MEGATRON MODEL 2, 3, 4, and 5

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20* (As furnished with models TM-554, TM-356, TM-356-W/HA Valve is ASSE 1017 listed

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM * TM-500A, TM-550A

MODEL TA. TA-SB 117.5mm mm HOT INLET. TA mm mm mm mm

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550

30 R -10 C F H C INSTALLATION. Maximum Operating Pressure 125PSI (860 KPA) for Hot and Cold Water. CAUTION

WALL MOUNTED SHOWER SYSTEMS

TA-300, TA-300-LF, TA-350, TA-350-LF

MEGATRON MODEL 2NB-LF, 3NB-LF, 4NB-LF, 5NB-LF NEXT GENERATION MANIFOLD SYSTEMS TM-520B-LF, 820B-LF, 920B-LF, 1520B-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF TM-820-LF, TM-920-LF, TM-1520A-LF

INSTALLATION ADJUSTMENT SERVICE TM-1520A-DT, TM-2020A-DT PARALLEL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE NEXT-GENERATION MANIFOLD SYSTEMS TM-520B-LF, TM-820B-LF, TM-920B-LF, TM-1520B-LF

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

DOMESTIC OUTLET. kg/cm 2 11 psi LEONARD LEONARD -10 C F LEONARD R THERMOSTATIC LEONARD LEONARD C F C F 60 COLD INLET HOT INLET

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20 (As furnished with models TM-554, TM-356, TM-356-W/HA, TM PRV, 8015, 12520, 15020)

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

MEGATRON MODEL 2N, 3N, 4N, 5N HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF, TM-820-LF, TM-920-LF, TM-1520A-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

LEONARD -10 LEONARD VALVE CO. CRANSTON RI USA. TYP TM US. P aten ts 2.970, 3,06 1, , " Maximum Operating Pressure 125PSI (8.6 Bar).

INSTALLATION ADJUSTMENT SERVICE 2P TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS

Installation S

INSTALLATION ADJUSTMENT SERVICE TM-1520A-2P, TM-1520A-2P-LF TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEMS TYPE *TM-600, TM-650, *TM-800, *TM-850, TM-5100, TM-5125

HOT INLET COLD INLET INSTALLATION

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B

MODEL 210, 210-LF THERMOSTATIC WATER MIXING VALVES INSTALLATION SETUP AND OPERATING INSTRUCTIONS

Thermostatic Radiator Valves (Caleffi)

INSTALLATION ADJUSTMENT SERVICE MEGATRON MODEL 8N-LF. Valve assemblies are ASSE 1017 listed

SS-7600 THERMOSTATIC MODEL INSTALLATION INSTRUCTIONS

SECTION DOMESTIC WATER PIPING SPECIALTIES

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE TM-200 (NEW STYLE) TMS-200 (VALVE ONLY)

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

INSTALLATION ADJUSTMENT SERVICE 2PS TM-2020B-2P, TM2020B-2PS-LF PARALLEL SYSTEMS

Installation S

BRADLEY CORPORATION DOMESTIC WATER PIPING SPECIALTIES Page 1 of 9

Installation S

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

Installation S

FM Mattsson. Pressure Balancing Thermostatic Mixing Valves FEATURES. - Different on the inside

Installation S

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

MIRAGE EC/QREC OH-ELO CONCEALED PENDENT SPRINKLER VK538 (K11.2) TECHNICAL DATA

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL

TIMES SQUARE TWO-HANDLE THERMOSTAT

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

Automatic Temperature Controller (ATC)

WAL-RICH CORPORATION SINCE 1950

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

FM Mattsson. Pressure Balancing Thermostatic Mixing Valves FEATURES. - Different on the inside

MEGATRON MODEL TA, TA-LF

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

Instructor: Sales person: Phone: Sales person: Phone: Sales person: Phone: Sales person: Phone: Service Manager: Phone: Service Manager: Phone:

microfast sr/qr extended coverage pendent sprinkler

Thermostatic mixing valves with interchangeable cartridges

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

Model SFMV Series. Lead-Free Supply Fixtures Based On The MV17 Master Mixing Valves

Transcription:

Mixing Safety & Performance for Over 100 Years WATER TEMPERATURE CONTROL SYSTEMS TM-2020B-LF-DT TM-2020B-2PS-LF MEGATRON 6NB-LF ASSE 1017 LOW LEAD CERTIFIED Made in the USA with Domestic and Imported Parts 1360 Elmwood Ave., Cranston, RI 02910 TF: 800.222.1208 P: 401.461.1200 F: 401.941.5310 www.leonardvalve.com

WATER TEMPERATURE CONTROL SYSTEMS Leonard Megatron Regulate water temperature for building hot water systems and other commercial, institutional and industrial applications. DURA-trol solid bi-metal thermostatic control Adjustable high temperature limit stops set for 120 F Mixed water capacity from 1-678 GPM (3.7-2567 l/min) Simple installation, reduced setup costs All lead-free bronze, brass and stainless steel construction System mounted on strut with return piping and circulator Factory-preassembled and tested as a complete control station Water Temperature DURA-trol Bi-Metal Control System Megatron All valve assemblies are ASSE 1017 Listed and 3rd Party certified as Lead-Free 1NB-LF 2NB-LF 3NB-LF 4NB-LF 5NB-LF 6NB-LF 7NB-LF 8NB-LF 10NB-LF 3/4 inlets, 1 outlet, 1-42GPM (3.7-159 l/min) 3/4 inlets, 1 outlet, 1-72 GPM (3.7-272 l/min) 1 inlets, 1-1/4 outlet, 1-84 GPM (3.7-318 l/min) 1-1/4 inlets and outlet, 1-103 GPM (3.7-390 l/min) 1-1/4 inlets, 1-1/2 outlet, 1-158 GPM (3.7-598 l/min) 2 inlets and outlet, 1-214 GPM (3.7-810 l/min) 2 inlets and outlet, 2-316 GPM (7.6-1196 l/min) 3 inlets and outlet, 2-428 GPM (7.6-1620 l/min) 4 inlets and outlet, 3-642 GPM (11.4-2430 l/min) Standard Megatron Systems Piping Methods Method 2 (up to 8.0 GPM) 1NB, 2NB, 3NB, 4NB Method 5 (over 8.0 GPM) 5NB, 6NB, 7NB, 8NB, 10NB Optional Piping M5 RP 1 RP 1-1/4 RP 1-1/2 RP 2 Method #5 piping for systems circulating over 8.0 GPM 1 Return line size (M5) 1-1/4 Return line size (M5) 1-1/2 Return line size (M5) 2 Return line size (M5) LMS-188-4P-BMS Building Management System Interface AU-3000 Audio Visual Alarm FM Floor Mounted FS Free Standing SCO Solenoid Control Option LC Less Circulator 2 Pump H High Temperature Recirculation loop with circulator 2 Pump R Redundant Recirculation pump RDU Remote Display Unit Megatron 8NB-LF-LC-FM 2-428 GPM (7.6-1620 l/min) 3 inlets/outlet, 1-1/2 return line 2 ASSE 1017

WATER TEMPERATURE CONTROL SYSTEMS 2018 Leonard Megatron Regulate water temperature for building hot water systems and other commercial, institutional and industrial applications. Paraffin-based thermostatic control solutions Adjustable high temperature limit stops set for 120 F Mixed water capacity from 0.25-416 GPM (0.95-1575 l/min) Simple installation, reduced setup costs All lead-free bronze, brass and stainless steel construction System mounted on strut with return piping and circulator Factory-preassembled and tested as a complete control station Water Temperature Paraffin Wax Control System Megatron 270-LF 370-LF XL-32A-LF XL-82-LF XL-150-LF XL-200-LF XL-150-2P-LF 1/2 inlets and outlet, 0.25-11 GPM (0.95-42 l/min) 3/4 inlets and outlet, 0.25-12.5 GPM (0.95-47 l/min) 3/4 inlets and outlet, 1-32 GPM (3.7-121 l/min) 1 inlets, 1-1/4 outlet, 1-58 GPM (3.7-219 l/min) 1-1/4 inlets, 1-1/2 outlet, 3-124 GPM (11.4-469 l/min) 2 inlets and outlet, 5.0-198 GPM (18.9-750 l/min) 2 inlets and outlet, 6-248 GPM (22.7-939 l/min) XL-200-SW-2P-LF 3 inlets and outlet, 5-198 GPM (18.9-750 l/min) Standard Megatron Systems - Piping Method Method W (wax and electronic only) Optional Piping RP 1 RP 1-1/4 RP 1-1/2 RP 2 1 Return line size 1-1/4 Return line size 1-1/2 Return line size 2 Return line size LMS-188-4P-BMS Building Management System Interface AU-3000 Audio Visual Alarm FM Floor Mounted FS Free Standing SCO Solenoid Control Option LC Less Circulator 2 Pump H High Temperature Recirculation loop with circulator 2 Pump R Redundant Recirculation pump RDU Remote Display Unit Megatron XL-150-2P-LF-BMSI-FS 6.0 248 GPM (23 938 l/min) 2 inlets/outlet, 1-1/2 return line 2018 Leonard Valve www.leonardvalve.com 3

HIGH CAPACITY MANIFOLD SYSTEMS Leonard High Capacity Manifold Systems Designed specifically for convention hotels, large apartments or condominiums and large prisons Regulate water temperature over a wide range of flows for large commercial and institutional applications. Thermostatic water mixing valves, DURA-trol solid bi-metal thermostatic control and paraffinbased thermostatic control solutions Ten-Year Limited Thermostat Warranty Adjustable high-temperature limit stops set for 120 F (49 C) Mixed water capacities up to 678 GPM Factory-preassembled and tested systems High Capacity Manifold Systems XL-150-2PS-LF 2 inlets/outlet, 6-248 GPM (22.7-939 l/min) TM-1520B-2PS-LF 2 inlets/outlet, 2-316 GPM (7.6-1196 l/min) XL-200-2PS-LF 3 inlets/outlet, 10-396 GPM (37.9-1499 l/min) TM-2020B-2PS-LF 3 inlets/outlet, 2-428 GPM (7.6-1620 l/min) TM-2020B-3PS-LF 4 inlets/outlet, 3-642 GPM (11.4-2340 l/min) Enclosures STSTL REC Stainless Steel Recessed Cabinet* STSTL EXP Stainless Steel Exposed Cabinet* *Available on selected models, contact Leonard SUFFIX TC SUFFIX IT Test Connection Piping on Outlet (2 Only, contact Leonard) Inlet Thermometers TM-2020B-2PS-LF-STSTL-REC TM-2020B-3PS-LF XL-150-2PS-LF 4 ASSE 1017

NEXT GENERATION HIGH-LOW SYSTEMS Leonard Next Generation High-Low Systems Control water temperature for domestic hot water systems, shower rooms and other commercial, institutional and industrial applications Dual thermostatic water mixing valves in a simple piping arrangement provide precise water temperature control of both high and low mixed water flow ranges DURA-trol solid bi-metal thermostatic control (Ten-Year Limited Thermostat Warranty) Adjustable high-temperature limit stops set for 120 F (49 C) Mixed water capacities up to 226 GPM (856 l/min) All lead-free bronze, brass and stainless steel construction Factory-preassembled and tested systems Next Generation System TM-420B-LF-DT 3/4 inlets, 1 outlet, 1-49 GPM (3.8-185 l/min) TM-520B-LF-DT 3/4 inlets, 1 outlet, 1-75 GPM (3.8-284 l/min) TM-820B-LF-DT 1 inlets, 1-1/4 outlet, 1-89 GPM (3.8-337 l/min) TM-920B-LF-DT 1-1/4 inlets and outlet, 1-115 GPM (3.8-435 l/min) TM-1520B-LF-DT 1-1/4 inlets, 1-1/2 outlet, 1-165 GPM (3.8-625 l/min) TM-2020B-LF-DT 2 inlets and outlet, 1-226 GPM (3.8-856 l/min) Optional Finish CP Enclosures STSTL REC STSTL EXP BWE REC BWE EXP Chrome Plated Stainless Steel Recessed Cabinet Stainless Steel Exposed Cabinet Baked White Enamel Recessed Cabinet Baked White Enamel Exposed Cabinet SUFFIX TC Test Connection Piping on Outlet LMS-188-4P-BMS Building Management System Interface SCO Solenoid Control Option SUFFIX IT Inlet Thermometers HT High Temperature Thermometer DURA-trol solid bi-metal thermostat directly linked to valve porting Locked temperature adjustment setting Adjustable high temperature limit stop Internal parts of bronze, brass and stainless steel TM-920B-LF-DT TM-186-920B-LF-DT-STSTL-REC 2018 Leonard Valve www.leonardvalve.com 5

THERMOSTATIC HIGH-LOW MASTER MIXERS XL Series Thermostatic Mixing Valves Copper encapsulated thermostatic control (Ten-Year Limited Thermostat Warranty) Mixed water capacities up to 216 GPM (818 l/min) All lead-free bronze, brass, and stainless steel construction Integral combination checkstops on inlets Locking temperature regulator Integral wall support Factory-preassembled and tested CASPAK Sizing Program Thermostatic High-Low Master Mixers XL-32A-LF 3/4 inlets/outlet, 1 33 GPM (3.8 125 l/min) XL-82-LF 1 inlets, 1-1/4 outlet, 1 61 GPM (3.8 231 l/min) XL-150-LF 1-1/4 inlets, 1-1/2 outlet, 3 130 GPM (11.4 492 l/min) XL-200-SW-LF 2 inlets/outlet, 5 208 GPM (18.9 787 l/min) Enclosures STSTL REC STSTL EXP BWE REC BWE EXP Stainless Steel Recessed Cabinet Stainless Steel Exposed Cabinet Baked White Enamel Recessed Cabinet Baked White Enamel Exposed Cabinet Optional Finishes RF Rough Bronze CP Chrome Plated (not available on XL-200-SW-LF) LWS BDT LMS-BMS AU-3000 Less Wall Support Ball Valve with Dial Thermometer on outlet Building Management System Interface Audio Visual Alarm XL-150-LF XL-82-LF XL-32A-LF XL-200-SW-LF 6 ASSE 1017

WATER TEMPERATURE CONTROL SYSTEMS 2018 LV Series are furnished with factory-assembled and test with: Highly responsive copper encapsulated thermostat assembly to control the intake of hot and cold water and regulate mixed water temperature Integral check valves on hot and cold inlets, wall supports, and locking temperature regulators Maximum hot water supply temperature: 200 F (93 C) Maximum supply pressure: 125 PSI Thermostatic Master Mixers LV-981A-LF 3/4 inlets/outlet, 2.5 44 GPM (9 157 l/min) LV-982-LF 1 inlets, 1-1/4 outlet, 3.0 66 GPM (11 250 l/min) LV-983-LF 1-1/4 inlets/outlet, 5.0 126 GPM (19 477 l/min) LV-984-LF 1-1/4 inlets, 1-1/2 outlet, 6.0 148 GPM (22.7 560 l/min) LV-985-SW-LF 2 inlets/outlet, 10 216 GPM (37.9 818 l/min) Enclosures STSTL REC STSTL EXP BWE REC BWE EXP Stainless Steel Recessed Cabinet Stainless Steel Exposed Cabinet Baked White Enamel Recessed Cabinet Baked White Enamel Exposed Cabinet Optional Finishes Hot water inlet Shuttle Mixing Chamber Adjustment knob Cold water Thermostatic inlet elements RF CP LWS BDT LMS-BMS AU-3000 Rough Bronze Chrome Plated (not available on LV-981A-LF or LV-985-SW-LF) Less Wall Support Ball Valve with Dial Thermometer on outlet Building Management System Interface Audio Visual Alarm LV-981A-LF LV-982-LF LV-983-LF LV-984-LF LV-985-SW-LF 2018 Leonard Valve www.leonardvalve.com 7

ACCESSORIES LMS-188-4P-BMS For those applications where it is desired to monitor temperature in the domestic hot water system, specify Leonard s Building Management System Interface. This LMS-188-4P is mounted in a cabinet, including an enclosure, temperature indication, a Type J thermocouple, a 9 power cord (plug in 120V) and an Ethernet category 5 connection for LMS-188-4P-BMS communication. AU-3000 To ensure additional protection, specify Leonard AU-3000 Audio Visual High Temperature Alarm Systems. Floor mounted (FM) For those applications MEGATRON with 2 legs, 3-1/2 and 45 braces front and back for mounting to floor in center of room. Free Standing MEGATRON with legs to floor to support the unit without hangers. 1360 Elmwood Ave., Cranston, RI 02910 TF: 800.222.1208 P: 401.461.1200 F: 401.941.5310 www.leonardvalve.com LV-110 REV 06/2018 2018 LEONARD VALVE COMPANY PRINTED IN THE U.S.A