LED retrofits! 4 T8 Specification Guide. Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! Pure Bright

Similar documents
TROFFER RETROFIT KIT (TRK)

T8 Self Ballasted UL & CSA LED TUBE RETROFITS

LED RETROFIT SOLUTIONS

Energy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight

2018 Instant Lighting Rebates Product Catalog

2018 Midstream Lighting Product Catalog

LHBXD LED Linear High Bay

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

LED Linear Design Highlights

Lumination LED Luminaires

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

LED ECO PANEL.

WARRANTY LED ECO PANEL.

BAS SDL8' LED Strip Diffused Lens

Millenium Os. Luminaire LED. For Stairwells and Public Spaces. Designed and manufactured in the USA. High Abuse Motion-Activated Lighting Product

Product Specifications MaxLumen MRI LED Diffused Lighting

LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:

SECTION INTERIOR LIGHTING

Product Specifications MaxLumen MRI LED Diffused Lighting

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

Product Specifications MaxLumen MRI LED Diffused Lighting

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

SDL4 LED Strip Diffused Lens

SYSTEM. field cuttable. lipleds 8200 Series

LED lighting for light industrial areas IHB series high bay LED luminaires. IHB series. High bay LED luminaires for light industrial areas

LED Lighting Product Guide. Spring A portfolio of industry-leading solutions that are changing the way we look at light.

Energy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015

BAYMAX TM LED LINEAR HIGHBAY FIXTURE BLHT SERIES

New LED Product Offerings

EarthTronics products. About us. Where efficiency meets innovation. T5 & T8 Linear. Founded in 2007, EarthTronics, Inc. is a Michigan based

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

LED RETROFIT CONVERSION KITS

Explosion Proof LED Light - Equivalent to Watt HID C1D2, UL Listed

Highbay Linear LED Series Flat Profile Design

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

Project: Comments: Prepared By: Control. Code Fixture & Trim D3 Wall Wash, Round. Platform & Control Wide Gamut, Tunable

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

Dimensions (111mm) (111mm) 3 (76mm)

EcoSystem H-Series Ballasts

LED Lighting Product Guide. Winter A portfolio of industry-leading solutions that are changing the way we look at light.

Fast. Precise. Versatile. UL Lighting Sciences

LED Lighting: Technology Selection and System Commissioning Course Number: CXENERGY1519

Emergency Lighting. Product Guide LED. The right source for the. right light

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

LHB LED High Bay. Technical Specifications. Description. Performance Data. Dimensions & Weights. Delivered Lumens Efficacy.

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

DHL-LP-LED Low Profile LED Linear High/Low Bay

Lumination LED Luminaires

P5500 LED Architectural Downlighting

Product Specifications

B. It is recognized that these standards are updated irregularly and lighting technology is changing rapidly.

Catalog Number. Notes

HIGH POWER LED RETROFIT MODULE

ACT.NOW.FOREVER 2017 LIGHTING PRODUCT CATALOG

Catalog # Project. Comments. Prepared by. Warranty Five year warranty

THINTEK G2 PANEL.

THINTEK G2 PANEL.

LED High Bay. 150W LED High Bay GLC-ANHB-150W-1. PERFORMANCE LED Chip Lumen Output (IES) Power Consumption Efficacy (IES) Beam Angle

E10 & L9 Low Wattage Light Cone Data

LED ROUND MINI PANELS

EcoSystem H-Series 347 V~ Ballast Overview

High Lux Performance White LED MR16 Lamp

Evolve LED Garage Light

Philips MASTER LEDbulb DIM W & W E27/B K 230 V

HIGH LUMINOUS EFFICIENCY

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

FPLHB - Fidelux Premier Linear Highbay

TRMUNV220ACXXXA UNIVERSAL VOLTAGE HIGHBAY RETROFIT KIT

CL001 >400 Watt lamp basecase, up to 600 Watt replacement fixture $95.00 Fixture

Canadian Model Number Designations. Models ending in... LED-8030M42 C-A = 347V LED-8030M42 -A = 120/277V LED-8030M42 C = 120/347V

BAS SFP22 Edge-lit LED Panel

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

Basics Series Surface Mount LED Fixtures. Affordable and easy-to-install, 4" and 6" fixtures. It s a. Snap

Classix 6" 6" Round Lens Wall Wash

Hi-lume 3D Overview. Fluorescent Dimming Ballasts Hi-lume 3D Architectural Dimming

Technical application guide

Classix 6" 6" Round Lens Wall Wash

LEDHB LINEAR HIGH-BAY LED LUMINAIRE PART NUMBER BUILDER 140L** 200L** 170L*** 230L*** 300L*** 400L*** 840* IN 48IN

LM Series LED Architectural Downlighting HIGH LUMEN OUTPUT RECESS / SURFACE MOUNT GREEN ENERGY EFFICIENT LIGHTING

PRODUCT DATA SHEET LIGHTING PRODUCTS

LED Reliability and Current Standards for Measurement

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

Excellence in LED Lighting. e-solis Edge Lit LED Panels.

Pacific Gas and Electric Company Energy Efficiency Rebates for Your Business. Lighting Rebate Catalog Saving energy for a brighter future

56W Vapor Proof LED Fixture V Dimmable - DALI Network lms - IP67 - Outdoor Applications

Advanced Lighting For Office

WARRANTY FLEXOPTIX HIGH BAY/FLOOD.

LED Shoplight fixture

Hi-lume 3D Overview. Fluorescent Dimming Ballasts

TERRALUX RETROFIT LED LIGHTING

Suite: Foyer/Hallway/Closet PROJECT: ZIGG CONDOS TYPES ' S1 ' & ' S6 ' Description: Flush Mount lass. Finish: Diameter: " Height: 4" Lamp: x

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS

AVAILABLE THROUGH GRAINGER. LED Fixtures

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

LED RETROFIT CONVERSION KITS

Metalux SWLED LED. Type. Catalog # Project. Date. Comments. Prepared by

Transcription:

T8 PBT8-DL5004EFX-U AC 100V-277V Day Light 5000K Pure Bright LED retrofits! Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! With the highest safety rating available, UL Listed, these LED T8 Tubes replace fluorescent tube lights without any changes to your existing fixture or ballast. Retrofits in seconds and produces 60% in energy savings. 4 T8 Specification Guide

LED T8 Retrofit Product Description Illumination Performance: With a 320 illumination angle, the design allows more up light, providing a more uniform light output. This lamp delivers lumens of full spectrum LED light at 80 CRI while achieving 135 lumens per watt in average at the fixture level. Color Availability: The Pure Bright T8 LED tube lights are available in three color temperatures: 3000K, 4000K, and 5000K. UL testing: Our tube lights have passed the most rigorous testing procedures at Underwriters Laboratories and have archived the UL Listed category. Ballast Compatibility: Our tube light work with all electronic T8 ballasts, rapid-start, programmed-start and instantstart ballasts. Dimming: Dim with dimming ballasts (Triac and 0-10 VDC), enabling daylight harvesting and profile dimming based on controls. California Title 24 ready. The existing T8 electronic ballast stays in place. To retrofit, replace the fluorescent bulb with the Pure Bright LED tubes. Your existing ballast acts as the driver. Pure Bright Performance Table Retrofits existing 32W T8 fluorescent tube lights. No electrical alterations needed. Efficacy: 125.85 LPW in average to all color temperature Lamp Delivered Light Output: 2,068 lumens per 4 LED tube light Target System Delivered Light Output: 2,068 lumens Input Power: 13.0 Watts @ 1.0 ballast factor / 14.6 Watts @ 0.88 ballast factor / 16.6 Watts @ 0.78 ballast factor CRI: 80 Down Flux of Lamp: 78.3% Up Flux of Lamp: 21.71% Output Flux Ratio: in Solid Angle : 50.21% Installation: Installs into existing linear fluorescent luminaire and operates on existing ballast. Ballasts serves as LED driver. CIE Type: Semi-direct lighting. 78/22 flux direction designed to fill luminaire with illumination to provide even lighting. CCT: 3000K, 4000K, and 5000K Input Voltage: 120-277 VAC: determined by existing fluorescent ballast Lifetime: In-Situ Temperature Measurement Test 70,000 hours Warranty: 10 years Location: Suitable for damp or dry locations. Mounting: Linear fluorescent fixtures Controls: Dimmable (ballast dependent) enabling daylight harvesting and profiling. Ordering Information Example: PBT8-DL5004EFX-U PBT8 DL50 04 EF 4 U Product Color Temperature Length T8 Ballast Type Control Options Pure Bright LED T8 DL50: 5000K (Day Light) NW40: 4000K (Neutral White) WW30: 3000K (Warm White) 02: 2-Ft 03: 3-Ft 04: 4-Ft UB: 4-Ft U-Bend Other lengths available on request EF: Electronic Fluorescent Nearly all 120-277V T8 electronic ballasts including Instant-Start, Rapid-Start and Programmed-Start versions 2- or 4- wires input Dimmable based on ballast U: Universal Frosted lens Pure Bright Lighting Page 2 USA: (954) 780 8700 Canada: (416) 800 6091

Pure Bright T8 LED Tube Dimensions Overall Length Tube Length (without pin) Tube Diameter Pin Distance Pin Diameter Pin Height 47.27 (1212 mm) 46.72 (1198 mm) 1.0 (26 mm) 0.5 (13 mm) 0.096 (2.3 mm) 0.29 (7.0 mm) Ballast Driver Electronic Characteristics AC Input Range Power Factor Total Harmonic Distortion Efficiency Operation Temperature Storage Temperature 120 to 277VAC; 347VAC for Canada Determined by Ballast <20%, determined by ballast 0.99 @ 1.0BF = 125.85 LPW -20 C to +50 C, Tc: 58.3 C -20 C to +85 C Smart Driver Technology: Works With All T8 Ballast Types The Pure Bright unique patented design Smart Driver Technology has been in development for over five years. With UL Listed approval-the most rigorous NRTL requirements-there is no requirement to first compare ballast models for in-field installations. Lower testing approvals require installers to open ballast compartments, and to replace ballasts with those listed on UL-required installation instructions. Construction and Materials The lightweight aluminum heat sink efficiently draws hear away from the LED diodes. Lens materials are recognized and certified by Underwriters Laboratories (UL) to flammability specification UL-94 V-0. Pure Bright has been successfully tested on active oil tankers running 24/7 for over 50,000 hours (references available) under severe vibration conditions, with units installed in the boiler rooms operational at an average temperature of 117 F without failure. Optical System 320 wrap-around lens design places 22% of the illumination above the horizontal plane, and 78% below. This semi-direct designation enables full illumination of the fixture and ensures optimal lighting distribution. Spectral Performance Pure Bright LED Tubes provide significant improvements of illumination quality over fluorescent tubes. Shown at right is the distribution of 4000K bulbs. Controls Full dimmable (ballast dependent). C90 Zonal Lumen Distribution Zone Lumens % Lamp 0-30 307 16.0% 0-40 512 26.6% 0-60 966 50.2% 0-90 1,507 78.3% 90-120 285 14.8% 90-130 337 17.5% 90-150 395 20.5% 90-180 417 21.7% 0-180 1,925 100.0% Up/Down flux rate= 21.7% : 78.3% CIE Type: Semi-direct Lamp Light Distribution Curve (Units in Candella: cd) C0 /C180 C90 / C270 Spectroradiometric Parameters Spectral Distribution: 4000K Pure Bright Lighting Page 3 USA: (954) 780 8700 Canada: (416) 800 6091

Pure Bright Safety Ratings: UL Listed- A clear choice for your next project Pure Bright LED T8 tubes have passed the most rigorous testing procedures at Underwriters Laboratories and have received UL Listed approval. When you are considering ballast-compatible LED products, the NTL safety rating significantly impacts how you are to use the products. When manufacturers products claim Plug and Play, but have only achieved UL Classified, you must first check the ballast model number to ensure it matches approved ballasts on the UL-approved installation instructions (must be supplied with tubes); failure to check ballast compatibility may affect commercial property insurance claims). National, State and Local Electric Codes determine when an electrician is required to change ballasts. UL Component rated lamps are not field installable. UL Mark UL Mark Description* Field Implications Installation Implications The UL Listed mark appears on end products suitable for field installation. Products are covered by UL s Follow-Up Services program to verify that the end products continue to be manufactured in compliance with UL s safety requirements. UL Listed Marks appears on end products suitable for field installation. Facility liability insurance policies recognize this mark. Works with all T8 ballasts. No electrician needed. The UL Classified mark appears on products that UL has evaluated but only with respect to specific properties, a limited range of hazards, or suitability for use under limited or special conditions. The UL Component mark is specifically used on parts are part of a larger product or system. These components have restrictions on their performance or may be incomplete in construction. UL Classified products are limited to specific ballast model numbers in ULapproved installation instructions. Facility liability insurance policies may be voided where inconsistencies exist. UL Component products in this category are intended to be installed in another end product, and are intended to be installed at the factory, not in the field. Electrician required where existing ballast is not included on UL-approved installation instructions list. Field installations in no approved. *Reference: http://ul.com/corporate/marks/ul-listing-and-classification-marks/apperance-and-significance/marks-for-north-america/ As Local Building Codes: Pure Bright Plastics Fire Safety Rating: UL 94-V-0 Fire codes, life safety and model building codes include numerous requirements that products and materials meet specified minimum flammability ratings. By ensuring that building materials meet hourly fire resistance ratings and don t exceed flame spread and smoke developed ratings, occupant safety is optimized. Failure to meet these minimum standards increases the chance of fire and smoke spread, and increased dangers for building occupants. The Pure Bright T8 LED tube lens materials are recognized and certified by Underwriters Laboratories to flammability specification UL 94 V-0 under yellow card listing. The UL 94 Standard provides a method for rating the ignition characteristics of plastic materials. The UL 94 V indicates a vertical burn test that is used widely for plastic materials that are used mostly in electrical devices. In this test-five vertically mounted samples are exposed to two successive ten-second bottom ignitions for a ¾ 50W Terrel burner flame ignition source. Flame resistance is then classified according to: 1) The time for the flame to self-extinguish, and 2) The duration of the afterglow To achieve a V rating (e.g. V-2, V-1, or V-0) the test samples, placed vertically with the test flame impinging on the bottom of the sample, must extinguish within specified times, not burning to the top clamp or dripping molten material which ignites a cotton indicator. The V-0 rating of our lens polymer is the highest rating under the UL 94-V test which means that: a) The extinguishment time (for each samples) was 0-10 seconds b) The afterglow time was 0-30 seconds per sample c) There are no flaming drips Pure Bright Lighting Page 4 USA: (954) 780 8700 Canada: (416) 800 6091

As a manufacturer, we take extra steps to ensure that use of our products in your facilities meet or exceed state and local building codes. We offer to work with you on your upcoming projects, and to ensure that you provide the safety your occupants deserve. EXAMPLE, New York City Building Codes 1 state that plastics in a lighting fixture must meet a Flame Spread Index within ASTM E 84 standards; defined by an ignition test of 7 seconds in duration. Since the UL 94-V-0 testing (two 10 second ignitions with an open flame) exceeds this, UL 94-V-0 more than meets New York City s requirement. (Reference: Section BC 2606.7.5: PLASTIC, Electrical Lighting Fixtures) Installation The Pure Bright ballast compatible LED T8 replace fluorescent tube lights with a twist. 1. Turn OFF power 2. Remove the fluorescent tube from fixture 3. Install Pure Bright LED T8 into fixture 4. Turn ON power Pure Bright Lighting Page 5 USA: (954) 780 8700 Canada: (416) 800 6091