Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Similar documents
Satellite XT. Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Life Safety Network. Intelligent solutions for advanced requirements

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

Unipoint controller. The Unipoint, a simple DIN rail mounted controller

Midas. Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes

Metro Gas Detector. The Metro addressable gas detector enables remote monitoring of flammable and toxic gas hazards

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Series 3000 XPIS. 2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sieger Apex. Flexibility that meets your requirements

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Xgard. Fixed detectors For flammable, toxic or oxygen gases

GAS DETECTOR ST400EC PART.NO

Searchpoint Optima Plus

Toxic Gas Detection. Model F12. Toxic Gas Detection

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Operating Instructions

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

OLC(T) 100 FIXED GAS DETECTOR

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

MDA Scientific Midas. Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes

Model D12. Digital Gas Transmitter

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Operating Instructions and Maintenance Manual

3M Oldham OLCT 100. Description. Fixed Gas Detector

Fixed-Point Industrial Gas Detection

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

Monitores Personales. Personal Monitor

SIL 2. Ultima X Series Gas Monitors CERTIFIED

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

Ordering Information. Ordering Information. Transmitter S3KUX S3KAX

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Micro III (Models G203, G203S, and G213) Operation Manual

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

Fixed-Point Industrial Gas Detection

Sensepoint XCL. Gas Detection. Fixed Gas Detector FEATURES & BENEFITS. Flexible Output Options. Visual Integration. Faster Installation

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Introducing gas detection so intelligent, it s as close to 100% prevention as you can get

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

EC FX NH3 SECONDARY HEADLINE. A new and improved approach to ammonia gas detection

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

Sensepoint XCD. Flammable, toxic and oxygen. catalytic, electrochemical cell and infrared sensors.

Touchpoint Pro Flexible Gas Control System

Zareba Sensepoint Pro

Zareba Metro Gas Detector

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

MICRO III (G202 / G202s / G212) Single Gas Detector

Stand Alone DYNAGARD SP Operation Manual

Equipment. Model R002. Description. SF6 leak detector

Sensepoint XCD RTD. Remotely monitor toxic gases in Class 1, Div 2 areas while reducing the maintenance, training and overall cost of gas monitoring

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

System 57. An advanced world of intelligent gas detection system management

Sensepoint XCL Fixed Gas Detector

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Technical Summary. Searchpoint Optima Plus Specification. Output ma sink or source, (Default current source) 0-4 ma (Default 4 ma)

SP-220. Features. Combustible handheld gas leakage detector

Sensepoint XCD RTD. A gas transmitter for use with directly or remotely mounted toxic and Oxygen gas sensors

System 57. An advanced World of intelligent gas detection system management

Sensepoint XCD. Flammable, toxic and oxygen deficiency gas detector using catalytic, electrochemical cell and infrared sensors.

IGD.CO.UK

Gas Detection For Life

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

PHD6. Flexible, comprehensive monitoring backed up by high performance functionality

Application Note. Comparison of optical detection systems for Infrared (IR) Hydrocarbon gas detection

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

Fixed Gas & Flame Detection International Product Range Overview

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Honeywell Analytics is pleased to announce the release of Version firmware software for the SPM Flex TM product line.

SPM Flex Chemcassette Tape-Based Gas Detector

APPLICATION DATA SHEET

GMA 36 Pro. Operation Manual. Stand Alone Monitor

GMA 36 Pro. Operation Manual. Stand Alone Monitor

Warranty Registration

PROTECTION THAT MAKES SENSE Bluetooth Enabled Gas Detector

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

XNX Universal Transmitter. A universal transmitter compatible with all Honeywell Analytics gas sensor technologies DRAFT

MICRO IV. Operation Manual. Single Gas Detector

Micro IV. Single Gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

Honeywell Analytics. Order List BW Clip & IntelliDoX

Micro IV Operation Manual

portable gas analyser

Safety Manual. XNX TM Universal Transmitter. Table of Contents SIL 2 Certificates Overview Safety Parameters

G-TECTA TM. Portable Gas Detection Instruments

Operating Instructions

XNX Universal Transmitter

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Transcription:

Satellite XT Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Satellite XT Applications: Provides gas detection for: Gas cabinets Valve manifold box Equipment enclosure Ambient breathing zone Gas storage rooms OEM equipment Advantages: Fast, reliable, specific gas detection Continuous real time monitoring Interchangeable intelligent sensor cell No dynamic gas calibration required Generic sensor head electronics Low cost of ownership No moving parts to wear down or replace The Satellite XT is the simple solution for all Point-of-Use gas detection needs. Based upon the market s smallest and most reliable electrochemical cell technology, the Satellite XT offers flexibility, simplicity and ease of application. The Satellite XT can be purchased in either an analogue or digital configuration, allowing it to interface with new or existing facility control technologies. The digital Satellite XT is built on LonWorks technology. Life safety systems built on a LonWorks network platform allow users to leverage the cost efficiencies of distributed controls, while maintaining the integrity and reliability necessary for code compliant safety applications. The Satellite XT is an intelligent gas detection transmitter which utilises a unique electrochemical sensor to detect toxic, corrosive, and combustible gas. The Satellite XT is a Point-of-Use monitor normally located at or near a potential source of gas release. Field accessories allow sampling options for various environments including in situ duct detection and extractive designs for harsh or remote areas. Typical installations for gas detection sampling include gas cabinet exhaust ducting, valve manifold boxes, equipment enclosures and ambient breathing zones. Each digital Satellite XT transmitter bears a unique address for use on a LonWorks network. This feature allows it to participate in a community of other intelligent LonWorks devices, which when considered together, comprise a life safety system network. Gas concentration and alarm information are both displayed locally at the Satellite XT, as well as distributed onto the LonWorks network for use by other field devices. The Satellite XT provides complete programmability of all monitoring variables including gas type, alarm levels, and maintenance status.

Applications Sensor Extension Available lengths: 1 metre 2 metre 3 metre XT Series Advantages: XT Series: Modular set up to meet the needs of today and tomorrow DIN rail mounting for easy installation Small footprint Extractive Module XT: In-situ flow control Low maintenance Easy installation Options for the Satellite XT: The XT Series is a product generation designed to meet various gas detection and life safety requirements. The XT Series is built-up of the Satellite XT, the Extractive Module XT, and the Pyrolyzer Module XT. The modular set up allows users to easily change from Point-of-Use detection to an extractive detection. Extractive Module XT: The Extractive Module XT is the ideal add-on component which allows for gas sampling and detection in various environments, such as in-situ duct detection and detection in harsh or remote areas. Its primary function is the transportation of gas samples from the monitored point to the sensor. Typical installations include gas cabinet exhaust ducts, valve manifold boxes, and equipment enclosures, as well as installations under waffle slabs. Pyrolyzer Module XT: The Pyrolyzer Module XT completes the XT Series allowing for the detection of gases with Fluorine content. The central component of the Pyrolyzer Module XT, is the Pyrolyzer itself, which converts the gases to mineral acids.

Gas Sensors 9602 Gas Detection with Electrochemical Cells Substance / Sensor Sensor Part-No Nominal Range Comments AsH 3 Arsine (3 El.) 9602-6001 0... 1.00 ppm AsH 3 Arsine (2 El.) 9602-6000 0... 1.00 ppm special application AsH 3 Arsine (2 El.) 9602-6002 0... 10.0 ppm special application B 2 H 6 Diborane 9602-6200 0... 1.00 ppm Br 2 Bromine 9602-6800 0... 5.00 ppm Cl 2 Chlorine 9602-5300 0... 5.00 ppm ClF 3 Chlorine Trifluoride 9602-7410 0... 1.00 ppm ClO 2 Chlorine Dioxide 9602-7400 0... 1.00 ppm CO Carbon Monoxide 9602-5400 0... 500 ppm COCl 2 Phosgene 9602-6600 0... 1.00 ppm F 2 Fluorine 9602-6400 0... 5.00 ppm GeH 4 Germane 9602-6900 0... 5.0 ppm Hydrogen (1%) 9602-5100 0... 1.000 % vol. Hydrogen (4%) 9602-5101 0... 4.00 % vol. special range S Hydrogen Sulphide 9602-5200 0... 100 ppm S Hydrogen Sulphide (org.) 9602-5201 0... 30.0 ppm special application Se Hydrogen Selenide 9602-5600 0.00...5.00 ppm HBr Hydrogen Bromide 9602-7000 0... 30.0 ppm HCl Hydrogen Chloride 9602-5800 0... 30.0 ppm HCN Hydrogen Cyanide 9602-5700 0... 30.0 ppm HF Hydrogen Fluoride 9602-6500 0... 10.0 ppm HMDS Hexamethyldisilazane 9602-6715 0... 0.500 % vol. HMDS Hexamethyldisilazane 9602-6714 0... 500 ppm N 2 H 4 Hydrazine 9602-7600 0... 1.00 ppm NH 3 Ammonia 100ppm 9602-6704 0... 100 ppm Standard NH 3 Ammonia 1000ppm 9602-6705 0... 1000 ppm Standard, for higher range NO Nitric Oxide 9602-7200 0... 250 ppm NO 2 Nitrogen Dioxide 9602-7300 0... 25.0 ppm O 2 Oxygen 9602-5500 0... 25.0 % vol. O 3 Ozone 9602-7100 0... 1.00 ppm O 3 Ozone 9602-7101 0... 1.00 ppm Exhaust monitoring PH 3 Phosphine (2 El.) 9602-6100 0... 1.00 ppm special application PH 3 Phosphine (3 El.) 9602-6101 0... 1.00 ppm SiH 4 Silane 9602-6300 0... 50.0 ppm SO 2 Sulphur Dioxide 9602-5900 0... 25.0 ppm TEOS Tetraethyl Silicate 9602-7500 0... 100 ppm TMB Trimethyl Borate 9602-7510 0... 200 ppm TMP Trimethyl Phosphite 9602-7800 0... 30.0 ppm Note: Further gases and ranges on request

Gas Detection with Combustible Gas Sensors Substance / Sensor Sensor Part-No Nominal Range Comments Methane 9602-9900 0... 100 LEL for Satellite C only /Standard Methane 9602-9901 0... 100 LEL for Satellite C only Methane 9602-9902 0... 100 LEL for Sat-Ex C Version Methane 9602-9903 0... 100 LEL for Sat-Ex C Version Methane 9602-9905 0... 100 LEL for Sat-Ex C Version Further gases and ranges on request Pyrolyzer Module XT Gas Detection with Electrochemical Cells Substance / Sensor Sensor Part-No Nominal Range C 4 F 6 Hexafluoro-1,3-butadiene 9602-9732 0...50.0 ppm C 5 F 8 Octafluorocyclopentene 9602-9730 0... 20.0 ppm CH 3 F Methyl Fluoride 9602-9720 0... 0.500 % vol. DCE 1,2 Di-chloro-ethylene 1,2 9602-9600 0... 1000 ppm NF 3 Nitrogen Trifluoride 9602-9700 0... 50.0 ppm SF 6 Sulphur Hexafluoride 9602-9710 0... 0.500 % vol. Further gases and ranges on request Sensors 1. How do electrochemical sensors work? All Honeywell Analytics electrochemical sensor cells are amperometric type i.e. are fuel cell type acting like batteries, where one component, in order to generate a current, is missing: the gas that should be detected (target gas). The target gas diffuses through a gas permeable membrane into the sensor where an electrochemical reaction results in a low current that is direct proportional to the measured gas concentration (generally in na/ppm reading). 3. How does a sensor self test work? All relevant sensor data (ref. Pos 2) are programmed onto the PROM inside the electrochemical sensor. Our detectors can read this data. Every 24 hours an automatic sensor self-test is performed, which compares an electronically initiated sensor signal with the stored calibration curve. This makes sure that the sensors are always within specification that is set during the first calibration. If the sensor is out of specification the instrument will indicate that the sensor either needs to be checked or needs to be replaced. 2. How does the electrochemical sensor work with the detection instrument? The current is amplified to a signal that is processed through an electronic circuit in order to display the real-time gas concentration. Inner Housing PTFE Membrane Measuring Electrode (Anode) The zero current of the electrochemical cell is always present and is monitored and suppressed by the electronics. There are different ways to adjust the correct amplification factor of the electronics. Honeywell Analytics has created the intelligent sensor which features a built-in PROM. All relevant sensor data such as sensitivity, target gas, date of first calibration, calibration data, zero current, and alarm levels are programmed onto this chip. Our detectors can read this data and adjust the amplifying factor automatically. Separator Outer Housing Membrane for Pressure Compensation Reference Electrode Electrolyte Counter Electrode (Cathode) Memory Chip

Technical Specifications Satellite XT FTT Satellite XT FTT Satellite XT FTT/R Satellite XT FTT/C Satellite XT R Power requirements Voltage 12 to 24 VDC 12 to 24 VDC 12 to 24 VDC 12 to 24 VDC Consumption max. 0.6W max. 1.4W max. 0.9W max. 1.4W Network Data transmission 78Kb per second 78Kb per second 78Kb per second Wiring topologies Free, e.g. Bus, Star, Loop, or Mixed Free, e.g. Bus, Star, Loop, or Mixed Free, e.g. Bus, Star, Loop, or Mixed Wiring Network 4-wire shielded cable 4-wire shielded cable 4-wire shielded cable 4-wire shielded cable 2 x 2 x 1.0mm 2 / 2 x 2 x 1.0mm 2 / 2 x 2 x 1.0mm 2 / 2 x 2 x 1.0mm 2 / 17 AWG (approx. 2m delivered 17 AWG (approx. 2m delivered 17 AWG (approx. 2m delivered 17 AWG (approx. 2m delivered with instrument) with instrument) with instrument) with instrument) Relay contacts 6-wire shielded cable 6 x 0.25mm 2 / 6-wire shielded cable 6 x 0.25mm 2 / 23 AWG (approx. 3m delivered with 23 AWG (approx. 3m delivered with instrument) instrument) Relay outputs Contacts 3 x SPST (Single-Pole Single-Throw) 3 x SPST (Single-Pole Single-Throw) Max. ratings 250 VAC / 30 VDC, 2A 250 VAC / 30 VDC, 2A Graphic display 122 x 32 dots with backlight 122 x 32 dots with backlight 122 x 32 dots with backlight 122 x 32 dots with backlight Status LED Green Green Green Green Keypad 6 touch-sensitive membrane 6 touch-sensitive membrane 6 touch-sensitive membrane 6 touch-sensitive membrane function keys function keys function keys function keys Physical dimensions Size 145 x 95 x 50mm 145 x 95 x 50mm 145 x 95 x 50mm 145 x 95 x 50mm LxWxD 5.7 x 3.7 x 2.0 5.7 x 3.7 x 2.0 5.7 x 3.7 x 2.0 5.7 x 3.7 x 2.0 Weight 480g (17oz) 650g (23oz) 520g (18oz) 620g (22oz) Mounting Special mounting plate Special mounting plate Special mounting plate Special mounting plate (delivered with instrument) (delivered with instrument) (delivered with instrument) (delivered with instrument) Housing protection class IP 52 (option: IP 65) IP 52 (option: IP 65) IP 52 (option: IP 65) IP 52 (option: IP 65) RFI / EMC EN 55022 EN 55022 EN 55022 EN 55022 EN 50082-2 EN 50082-2 EN 50082-2 EN 50082-2 Operating conditions Temperature -20 C up to +40 C -20 C up to +40 C -20 C up to +40 C -20 C up to +40 C -4 F up to +104 F -4 F up to +104 F -4 F up to +104 F -4 F up to +104 F Pressure 700 up to 1300hPa 700 up to 1300hPa 700 up to 1300hPa 700 up to 1300hPa Humidity 20 up to 90% r.h. 20 up to 90% r.h. 20 up to 90% r.h. 20 up to 90% r.h. Part number 9602-0400 9602-0405 9602-0450 9602-0505 Clean Room Digital version

Satellite XT 4-20 ma Satellite XT 4-20 ma Satellite XT 4-20 ma/r Satellite XT4-20 ma/c Power requirements Voltage 12 to 24 VDC 12 to 24 VDC 12 to 24 VDC Consumption max. 1W max. 1.8W max. 1.4W Analogue Signal Output Monitoring mode 2-20mA 4-20mA 78Kb per second Warning condition 2.8-4 ma 0.1Hz 2.8-4 ma 0.1Hz 2.8-4 ma 0.1Hz Maintenance mode 2.4-4 ma 1Hz 2.4-4 ma 1Hz 2.4-4 ma 1Hz Fault range 0-2mA 0-2mA 0-2mA Wiring Analogue interface 3-wire shielded cable 3x1.0mm 2/ 17 AWG 3-wire shielded cable 3x1.0mm 2/ 17 AWG 3-wire shielded cable 3x1.0mm 2/ 17 AWG (approx. 2m delivered with instrument) (approx. 2m delivered with instrument) (approx. 2m delivered with instrument) Relay contacts 6-wire shielded cable 6x0.25mm 2 / 23 AWG (approx. 3m delivered with instrument) Relay Outputs Contacts 3 x SPST (Single-Pole Single-Throw) Max. ratings 250 VAC / 30 VDC, 2A Graphic Display 122 x 32 dots with backlight 122 x 32 dots with backlight 122 x 32 dots with backlight Status LED Green Green Green Keypad 6 touch-sensitive membrane 6 touch-sensitive membrane 6 touch-sensitive membrane function keys function keys function keys Physical Dimensions Size 145 x 95 x 50mm 145 x 95 x 50mm 145 x 95 x 50mm LxWxD 5.7 x 3.7 x 2.0 5.7 x 3.7 x 2.0 5.7 x 3.7 x 2.0 Weight 480g (17oz) 650g (23oz) 520g (18oz) Mounting Special mounting plate Special mounting plate Special mounting plate (delivered with instrument) (delivered with instrument) (delivered with instrument) Housing Protection Class IP 52 (option: IP 65) IP 52 (option: IP 65) IP 52 (option: IP 65) IP 52 (option: IP 65) RFI / EMC EN 55011 EN 55022 EN 55011 EN 50082-2 EN 50082-2 EN 50082-2 Operating Conditions Temperature -20 C up to +40 C -20 C up to +40 C -20 C up to +40 C -4 F up to +104 F -4 F up to +104 F -4 F up to +104 F Pressure 700 up to 1300hPa 700 up to 1300hPa 700 up to 1300hPa Humidity 20 up to 90% r.h. 20 up to 90% r.h. 20 up to 90% r.h. Part number 9602-0200 9602-0205 9602-0250 Analogue version

Our Product Range Fixed Gas Monitoring Honeywell Analytics offers a wide range of fixed gas detection solutions for a diverse array of industries and applications including: Commercial properties, industrial applications, semiconductor manufacturers, energy plants and petrochemical sites. Detection of flammable, oxygen and toxic gases (including exotics) Innovative use of 4 core sensing technologies paper tape, electrochemical cell, catalytic bead and infrared Capability to detect down to Parts Per Billion (ppb) or Percent by Volume (%v/v) Cost effective regulatory compliance solutions Portable Gas Monitoring When it comes to personal protection from gas hazards, Honeywell Analytics has a wide range of reliable solutions ideally suited for use in confined or enclosed spaces. These include: Detection of flammable, oxygen and toxic gases Single gas personal monitors worn by the individual Multi-gas portable gas monitors used for confined space entry and regulatory compliance Multi-gas transportable monitors used for temporary protection of area during site construction and maintenance activities Technical Services At Honeywell Analytics, we believe in the value of great service and customer care. Our key commitment is providing complete and total customer satisfaction. Here are just a few of the services we can offer: Full technical support Expert team on hand to answer questions and queries Fully equipped workshops to ensure quick turnaround on repairs Comprehensive service engineer network Training on product use and maintenance Mobile calibration service Customised programmes of preventative/corrective maintenance Extended warranties on products Find out more www.honeywellanalytics.com Contact Honeywell Analytics: Europe, Middle East, Africa Life Safety Distribution AG Wilstrasse 11-U31 CH-8610 Uster Switzerland Tel: +41 (0)44 943 4300 Fax: +41 (0)44 943 4398 gasdetection@honeywell.com Americas Honeywell Analytics Distribution, Inc. 405 Barclay Blvd. Lincolnshire, IL 60069 USA Tel: +1 847 955 8200 Toll free: +1 800 538 0363 Fax: +1 847 955 8208 detectgas@honeywell.com Asia Pacific Honeywell Analytics Asia Pacific #508, Kolon Science Valley (1) 187-10 Guro-Dong, Guro-Gu Seoul, 152-050, Korea Tel: +82 (0)2 2025 0307 Fax: +82 (0)2 2025 0329 analytics.ap@honeywell.com Technical Services ha.emea.service@honeywell.com www.honeywell.com Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract. H_Satellite XT_DS01050_V1_EMEA 09/07 2007 Honeywell Analytics 12152