UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications

Similar documents
[U] Serie MOV. Manual de Ingeniería

[U] Serie MHB / MHA Manual de Ingeniería

MANUAL DE INGENIERIA. Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79

Four-way Cassette Type

Floor-Standing Type(E Series)

Ceiling & Floor type Unit

Multi Inverter Air Conditioning Condensing Units - Summary

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

Service Manual. Multi Split Type Heat Pump Air Conditioners. Applied to: HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_HOS-21U11IM

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Part 1 General Information... 1 Part 2 Outdoor Unit... 4 Part 3 Installation... 45

High static Pressure Duct Type Air-conditioner

Service Manual. Air Conditional

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

MINI CHILLER INVERTER H4 Service manual MUENR-H4 (5, 7, 10, 12, 14, 16 kw)

Content. The specifications, designs, and information in this book are subject to change without notice for product improvement.

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Aqua Mini Full DC Inverter Unitary Chiller 50Hz. Content

Floor-Standing Type(S2 Series)

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

DC Inverter Multi-split System Technical Manual - 50Hz/R410a

Service Manual. Air Conditional

1. Features Specification Dimensions Refrigeration cycle diagram Operation limits

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Midea R410A Domestic Pools & Spas Heat Pump Water Heater 50Hz A1 Series Technical Manual

Window Y9USC/E 09 / 12 / 18 B5R

Service manual. MIV V4+ Mini

Technical Guide. Split Air-Conditioners Equipment Residential COS Series

1. Product Lineup. 2. External Appearance. 3. Nomenclature M R C 36 H W N1 - R. Power supply R: 380~415V 3Ph~ 50Hz. Refrigerant type N1: R410A

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

COMMERCIAL AIR CONDITIONERS. Aqua Mini Chiller 50/60Hz

Thank you for selecting LENNOX air conditioners.

MODEL: CCT 301 INV CCT 501 INV CCT 70 INV-S CCT 100 INV-S CCT 140 INV-S CCT 170 INV-S

R410A50Hz Universal Outdoor Series Technical Manual

Submittal Data Sheet

TECHNICAL & SERVICE MANUAL

SERVICE MANUAL CONDENSING UNIT ASE-18AH, ASE-24AH, ASE-36AH, ASE-48AH, ASE-60AH

R4H4. Product Specifications

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

R4H4. Product Specifications

inverter mini chiller

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

Cassette SERVICE MANUAL. YKHC 18 to 48 YKHC 18 YKHC 24 YKHC 30 YKHC 36 YKHC 48 SM-YKHC-18-48GB 03-07

Midea Precision Air Conditioner Technical Manual (Down delivery series)

TECHNICAL DATA & SERVICE MANUAL

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units

Air Conditioners. Technical Data RZQG-L

N4H4. Product Specifications

1. Outdoor units lineup

Concealed Ducted Split Series R-407C MBH

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Blanc ON-OFF Series. Service Manual 2016

Technical Manual. R410A 50Hz Universal Outdoor Series Inverter type. R410A50Hz Universal Outdoor Series Technical Manual LCAC/2016.

13 SEER CONDENSING UNITS & AIR HANDLERS

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL GUIDE MODELS: DCPM/DHPM PREMIUM SERIES DUCTLESS SINGLE-SPLIT AIR CONDITIONERS AND HEAT PUMPS 22 SEER 1 PHASE 3/4 THRU 3 NOMINAL TONS

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

R22 air-cooled modular chiller 50Hz unit. Content

technical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air

Mobile Type Air Conditioner

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

High Heat COP. High/Low Stage

HITACHI ROTARY COMPRESSOR MODEL SG153BG3GC I. SPECIFICATION. This specification is applied to SHANGHAI HITACHI rotary compressor. 2.

MAC N-407 Air-Cooled Chiller

WCH5**4. Product Specifications

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

PAJ3. Product Specifications

CASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES

Wired controller KJR-08B/BE. Run. Fault. TB Tot. Out. Query. Heat. Net-On. Turn-On Mode

N4A6. Product Specifications

DC Inverter Multi-split System Technical Manual - 50Hz/R410a

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Air Conditioner Service Manual

PAR5. Product Specifications

Installation, Operation & Maintenance

MODULAR CHILLER. R410a R22

Specifications. (Model) KSIB009-H /2500 (W) 10600/9000(Btu/h) 13000/9500(Btu/h) 1250/ / SEER 16 HSPF 9.

AIR HANDLER UNIT R410A 60HZ ON-OFF CONTROL

MACH N-407 Heat Pump Air-Cooled Chiller

SERVICE MANUAL UNI ON/OFF ASC-60A

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ductless Multi Split. Continuous Comfort. Endless Options.

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

Transcription:

UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications Model UCV-76C UCV-96C Code 220075900040 220075900020 Power supply V- Ph-Hz 380-415~3~50 Capacity Btu/h 76000 96000 Cooling Input W 8100 10000 Rated current A 14.7 16.5 Max. input consumption W 12000 12000 Max. input current A 21.0 21.0 Starting current A 60 70 Model 403DH-64C2-X10( 2) 503DH-80C2(A) ( 2) Type Scroll Scroll Brand Hitachi Hitachi Supplier Hitachi Hitachi Capacity Btu/h 40260 50837 Compressor Input W 3600 4400 Rated current (RLA) A 6.8 8.34 Locked rotor Amp (LRA) A 56 66 Thermal protector Inner Inner Capacitor uf 20UF/450V 25UF/440-450V Refrigerant oil ml 1200 1400 Model YDK400-8C YDK900-6C Type AC motor AC motor Outdoor fan motor Brand Willing YongAn Input W 670/550 1000 Capacitor uf 20 20 Speed r/min 670/550 820 Number of rows 3 3 Tube pitch(a)x row pitch(b) mm 25.4x22 25.4x22 Fin spacing mm 1.5 1.5 Outdoor coil Fin type hydrophilic arcuate fin alum inurn foil Tube outside dia. and type mm φ9.53 φ9.53 innergroove tube innergroove tube Coil length x height x width mm 1917 710 66 1917 710 66 Number of circuits 14 14 Outdoor air flow m 3 /h 7200 10400 Outdoor noise level db(a) 64 67 Dimension (W H D) mm 980 1160 800 980 1160 800 Outdoor unit Packing (W H D) mm 1045 865 1260 1045 865 1260 Net/ Gross weight kg 218/228 218/228 Refrigerant Type R22 R22 type/quantity Charged volume g 6400 7000 Design pressure MPa 1.0/2.6 1.0/2.6

Liquid side/ Gas side mm(inch) φ9.53/φ19 φ9.53/φ19 Refrigerant piping Max. pipe length m 30 30 Max. difference in level m 20 20 Connection wiring Power wiring mm 2 5 6.0 5 6.0 Signal wiring mm 2 3 1.0 3 1.0 Operation temp 17 ~30 Ambient temp Cooling: 17 ~43 Application area m 2 80-120 100-150

Model UCV-76H UCV-96H Code 220075900030 220075900010 Power supply V- Ph-Hz 380-415~3~50 Capacity Btu/h 76000 96000 Cooling Input W 8100 10200 Rated current A 14.7 16.7 Capacity Btu/h 83600 105600 Heating Input W 8000 9800 Rated current A 14.5 16.3 Max. input consumption W 12500 12500 Max. input current A 22.0 22.0 Starting current A 60 70 Model 403DH-64C2-X10( 2) 503DH-80C2(A) ( 2) Type Scroll Scroll Brand Hitachi Hitachi Supplier Hitachi Hitachi Capacity Btu/h 40260 50837 Compressor Input W 3600 4400 Rated current (RLA) A 6.8 8.34 Locked rotor Amp (LRA) A 56 66 Thermal protector Inner Inner Capacitor uf 20UF/450V 25UF/440-450V Refrigerant oil ml 1200 1400 Model YDK400-8C YDK900-6C Type AC motor AC motor Outdoor fan motor Brand Willing YongAn Input W 670/550 1000 Capacitor uf 20 20 Speed r/min 670/550 820 Number of rows 3 3 Tube pitch(a)x row pitch(b) mm 25.4x22 25.4x22 Fin spacing mm 1.5 1.5 Outdoor coil Fin type hydrophilic arcuate fin alum inurn foil Tube outside dia. and type mm φ9.53 φ9.53 innergroove tube innergroove tube Coil length x height x width mm 1917 710 66 1917 710 66 Number of circuits 14 14 Outdoor air flow m 3 /h 7200 10400 Outdoor noise level db(a) 64 67 Dimension (W H D) mm 980 1160 800 980 1160 800 Outdoor unit Packing (W H D) mm 1045 865 1260 1045 865 1260 Net/ Gross weight kg 225/235 225/235

Refrigerant Type R22 R22 type/quantity Charged volume g 6400 7000 Design pressure MPa 1.0/2.6 1.0/2.6 Liquid side/ Gas side mm(inch) φ9.53/φ19 φ9.53/φ19 Refrigerant piping Max. pipe length m 30 30 Max. difference in level m 20 20 Connection wiring Power wiring mm 2 5 6.0 5 6.0 Signal wiring mm 2 4 1.0 4 1.0 Operation temp 17 ~30 Ambient temp Cooling: 17 ~43 Heating:- 7 ~24 Application area m 2 80-120 100-150

Model UCV-150H Code 220075900000 Power supply V- Ph-Hz 380~415-3-50 Supply electricity type Separated supply electricity Capacity Btu/h 150000 Cooling Input W 16000 Rated current A 30 EER Btu/W.h 9.38 Capacity Btu/h 165000 Heating Input W 17000 Rated current A 32 COP Btu/W.h 9.71 Max. input consumption W 24000 Max. input current A 39 Starting current A 70 Model 603DH-90C2Y-X10 ( 3) Type Scroll Brand Hitachi Supplier Guangzhou Hitachi Capacity Btu/h 57322( 3) Compressor Input W 5000( 3) Rated current (RLA) A 9.5( 3) Locked rotor Amp (LRA) A 70( 3) Thermal protector Overload Protector (Internal) Capacitor uf 20uF/450V( 3) Refrigerant oil ml SUNISO 4GDI-HT / 1800ml( 3) Model YDK450-6A ( 2) Type AC Motor Outdoor fan motor Input W 720/420 ( 2) Capacitor uf 20uF/450V ( 2) Speed r/min 810/530 ( 2) Number of rows 3 Tube pitch(a)x row pitch(b) mm 25.4 22 Fin spacing mm 1.7 Outdoor coil Fin type Hydrophilic aluminum Tube outside dia. and type mm 9.53/Innergroove Coil length x height x width mm 2170 1220 66 Number of circuits 24 Outdoor air flow m 3 /h 14000 Outdoor noise level db(a) 63 Outdoor unit Dimension (W H D) mm 1380 1630 830 Packing (W H D) mm 1434 1790 860

Net/ Gross weight kg 356/382 Type R22 Refrigerant type/quantity Charged volume g 12000 Design pressure MPa 1.0/2.6 Liquid side/ Gas side mm(inch) 16/35 Refrigerant piping Max. pipe length m 50 Max. difference in level m 20 Connection wiring Power wiring mm 2 5 9.0 Signal wiring mm 2 4 1.0 Operation temp 17~30 Ambient temp -7~43 Application area m 2 180~240

2. Dimension 2.1 UCV-76C UCV-96C UCV-76H UCV-96H Unit: mm

2.2 UCV-150H

3. Service Space 3.1 UCV-76C UCV-96C UCV-76H UCV-96H Top view of the outdoor unit (multiple units installed) Note: 1. In case any obstacles exist above the outdoor unit, such obstacles must be 2000mm above the outdoor unit. 2. If miscellaneous articles are piled around the outdoor unit, such articles must be 400mm below the top of the outdoor unit.

3.2 UCV-150H 1). When installing the unit, leave a space for maintenance shown in the following figure. Install the power supply at the side of the outdoor unit. For installation procedure, see the relevant installation manual. 2). Ensure enough space for installation and maintenance. (See the following figure) NOTE: 1. In case any obstacles exist above the outdoor unit, such obstacles must be 2000mm above the outdoor unit. 2. If miscellaneous articles are piled around the outdoor unit, such articles must be 400mm below the top of the outdoor unit. The distance of the foundation bolt is shown in the following figure.

4. Piping Diagrams 4.1 UCV-76C UCV-96C Outdoor Unit Indoor Unit Condenser 1 Condenser 2 Capillary Evaporator 1 Evaporator 2 Comp 1 Comp 2 Vapor-liquid separator 4.2 UCV-76H UCV-96H Outdoor Unit Indoor Unit ST1 ST2 Condenser 1 Condenser 2 Capillary Evaporator 2 Evaporator 1 Comp 1 Comp 2 Vapor-liquid separator

4.3 UCV-150H

5. Wiring Diagrams 5.1 UCV-76C

5.2 UCV-76H

5.3 UCV-96C

5.4 UCV-96H

5.5 UCV-150H

6. Field Wiring 6.1 UCV-76C UCV-96C 6.2 UCV-76H UOV-96H

6.3 UCV-150H

7. Electric Characteristics Model Outdoor Unit Power Supply Compressor OFM Hz Voltage Min. Max. MCA TOCA MFA MSC RLA KW FLA UCV-76C 50 380V 342V 418V 20 21 60 49 6.7 0.4 3.1 UCV-76H 50 380V 342V 418V 20 21 60 49 6.7 0.4 3.1 UCV-96C 50 380V 342V 418V 23 23 72 54 7.9 0.9 1.93 UCV-96H 50 380V 342V 415V 20 23 60 54 7.9 0.9 1.93 UCV-150H 50Hz 380V/3ph 342V 415V 40 44 120 70 9.5 0.45 2 3.28 Remark: MCA: Min. Current Amps. (A) TOCA: Total Over-current Amps. (A) MFA: Max. Fuse Amps. (A) MSC: Max. Starting Amps. (A) RLA: Rated Locked Amps. (A) OFM: Outdoor Fan Motor. FLA: Full Load Amps. (A) KW: Rated Motor Output (kw)