PASSIVE FIRE PROTECTION FTI-MARNEROS LTD

Similar documents
Loss Prevention Standards

BRE & LPCB Ruth Tucker -Passive Fire Protection

Welcome to the. Firestop Seminar. Hilti Technical and Engineering Support

Managing Fire Safety in Occupied Buildings FM Ireland Fire Safety Theatre

FIREPRO SoftSeal System

The Association for Specialist Fire Protection. Understanding Best Practice in passive fire protection

Passive Fire Protection Guidance for the Fire Risk Assessor. Niall Rowan Technical Officer Association for Specialist Fire Protection

The Association for Specialist Fire Protection

The Passive Fire Protection Handbook

FIREPRO FIRESTOPPING AND PENETRATION SEALS PRODUCT GUIDE

The Passive Fire Protection Handbook

MECHANICAL FIRE STOPPING SOLUTIONS

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

PASSIVE FIRE PROTECTION GETTING IT RIGHT

PRODUCT SPECIFICATION FireMaster Plus

fire resistance testing

Passive Fire Protection Guidance. Niall Rowan Technical Officer Association for Specialist Fire Protection

- CONSTRUCTION FIRE SAFETY STANDARDS

EVOLUTIONS FIRE PROTECTION

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

Connecta System THE FIRE PERFORMANCE TUNNEL LIGHTING AND POWER SYSTEM

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

Smoke and Fire Curtains. Performance Door sets for security and Fire resistant applications. Northern Doors (UK) Ltd

Fire and Security Products and Services

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

Maintenance. Why Maintain Fire Doors? Regulations

Standards and third party certification

Fire Protection. Intumescent fire and smoke seals for door assemblies

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15.

ACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS

IFE Level 3 Certificate in Passive Fire Protection

IFE Level 3 Certificate in Passive Fire Protection

ELECTRICAL FIRE STOPPING SOLUTIONS

Advanced Fire Rated Ductwork Solutions

FACADES AND FIRE The Essential Elements

PRODUCT SPECIFICATION FireMaster Plus Concertina

The Physical Environment Portal: Module 5, LS Leadership

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

- CONSTRUCTION FIRE SAFETY STANDARDS

SMOKE & FIRE THE LEADING EDGE IN. Smoke & Fire Curtains

Intumescent Fire Dampers

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

for the Fire Protection of Buildings WAREHOUSES AND STORAGE BUILDINGS 1: DESIGN PRINCIPLES

BRISTOL: A History & Future.

Loss Prevention Standard

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

STEEL DUCT - FIRE RATED CLADDING INSTALLATION MANUAL

Regulatory Reform (Fire Safety) Order 2005

SMART FIRE CURTAINS INTISI7. for invisible fire protection closures

CI/SfB (68.5) February Intelligent security and fire protection. SecureFire S e c

Saving lives with coatings

IFE Level 2 Certificate in Passive Fire Protection

asphalt applications European Asphalt Standards and their application in the UK mpa asphalt Asphalt Information Service Mineral Products Association

Life Safety and Fire Resistant Glazing Systems

Understanding Passive Fire Protection

THE HOME OF REACTIVE PROTECTION SYSTEMS

Module 7. Control of Smoke & Highlights of Code Requirements

The Association for Specialist Fire Protection

FireMaster. The Fire Curtain Barrier WITHOUT CORNER POSTS. Inspiring design, maximising floor space and increasing income.

30 mm 180 mins RWS / HCM. 24 mm 120 mins RWS / HCM. GS Kitchen Extraction & Ventilation up to 240 mins, BS 476 pt 20 & 24

FIRESTOP INSPECTION. Dr. Selina LIN. Technical Manager August 01, FS Inspection 1

HIGH EXPANSION INTUMESCENT SEALANT Prevents the spread of smoke and fire

The Association for Specialist Fire Protection. Guidance in Passive Fire Protection

Fire Protection Industry

THE TRUE FIRE SURVIVAL CABLE

Kensington Aldridge Academy, London W10

FIRE & SMOKE CURTAINS

Fire Resistance of Timber Structures

Smoke Master SMIA Compact pressurisation and smoke exhaust system

General Principles of Smoke Control

PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex

Protective & Marine Coatings Europe, Middle East, Africa & India

FIRE PROTECTION INNOVATORS IN CABLE MANAGEMENT

Passive Fire Protection DuraSystems Barriers Inc.

SMOKESTOP evacu8 ACTIVE SMOKE BARRIERS WITH EGRESS LEADING THE WAY IN FIRE PROTECTION

FIRE RISK ASSESSMENT COMPETENCY COUNCIL

New Approaches to Design for Fire Safety

BS EN ISO : 2010

Introduction of MSBC Secure India Pvt Ltd. Manufacturer & Installer of Fire Resistance Timber Doorsets

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

FIRE SAFETY MANAGEMENT PROTOCOL FIRE DOORS & FIRE DOOR ASSEMBLIES

for the Fire Protection of Buildings STAND- ALONE COLD STORES 1: DESIGN PRINCIPLES Insurers' Fire Research Strategy funding scheme

Introducing the Good Practice Notes on Life and Fire Safety for Hotels and Hospitals

Paper presented at the International Symposium on Protection of Cultural Heritage Buildings from Fire, Kyoto, Japan, April 6 7, 2003

FIREMASTER CONCERTINA TM

THE IMPORTANCE OF FIRE DOORS

for the Fire Protection of Buildings FOOD PROCESSING FACTORIES 1: DESIGN PRINCIPLES Insurers' Fire Research Strategy funding scheme

ACTIVE FIRE CURTAINS INTISI7

ACS.CCLP1 PD SAFETY ASSESSMENT CRITERIA INITIAL & RE-ASSESSMENT DOMESTIC LPG PERMANENT DWELLINGS

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

Best Practice BS 3621: 2007 BS 8621: 2007 BS 10621: 2007 dhf

PRODUCT CATALOGUE ACTIVE FIRE AND SMOKE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIRE & SMOKE CURTAINS

Passive Fire Protection SEMINAR INTRODUCTION & OVERVIEW

ASFP OBTAINS FUNDING FROM CITB-CONSTRUCTIONSKILLS

Good Practice Guide GPG

Shared Services Partnership

FIRE TUBE Fire protection for process pipes and structural steel

Transcription:

PASSIVE FIRE PROTECTION FTI-MARNEROS LTD the art of passive fire protection since 1989

ABOUT FTI - MARNEROS is the joining of the fire department of Chr. Marneros & Co Ltd and Fire and Thermal Installations Ltd who were both IFC Certified Passive Fire Protection Contractors, specializing in the design and installation of passive fire protection systems in both new and existing buildings. The joining of both companies provides the most dedicated passive fire protection company in Europe combining over 50 years of experience experience and knowledge in the UK, Cyprus, Germany, Russia, Ukraine, Spain and Bulgaria. We are approved installers of all major fire protection manufacturers. We have the knowledge and expertise to provide and install the most costefficient solution to any passive fire protection needs. And most importantly for the client, we can issue fire certificates on completion. Our commitment to Integrity, Quality and Safety has earned us the reputation among Architects, Engineers, Owners, Inspectors and Contractors as being the ONLY viable option to providing competent, expert supply, installations and certification of all passive fire protection solutions.

WHAT IS PASSIVE FIRE PROTECTION? THE FUNDAMENTAL PURPOSE OF FIRE PROTECTION SYSTEMS IS TO PREVENT THE PASSAGE AND SPREAD OF SMOKE AND FIRE, FROM ONE COMPARTMENT TO ANOTHER, TO ALLOW FOR THE SAFE ESCAPE OF THE BUILDING OCCUPANTS. SECONDLY TO PREVENT OR REDUCE THE AMOUNT OF DAMAGE TO THE BUILDING STRUCTURE, NEIGHBOURING STRUCTURES AND REDUCE THE RISK OF COLLAPSE FOR THE EMERGENCY SERVICES. A NUMBER OF THE FUNDAMENTAL REQUIREMENTS OF FIRE PROTECTION ARE SPECIFIED IN THE BUILDING REGULATIONS AND EUROPEAN DIRECTIVES ADVOCATING THE FOLLOWING: MEANS OF ESCAPE INTERNAL SURFACE SPREAD OF FLAME TO LININGS STRUCTURAL INTEGRITY OF THE BUILDING FIRE COMPARTMENTATION ACCESS AND FACILITIES FOR EMERGENCY SERVICES COMPETENT, EXPERT, 3 RD PARTY CERTIFICATED PASSIVE FIRE PROTECTION CONTRACTORS TO ENSURE THE ABOVE IS CORRECT OTHER MORE COMMERCIAL REASONS FOR THE USE OF FIRE PROTECTION SYSTEMS, IS TO REDUCE THE AMOUNT OF DAMAGE AND PREVENT COLLAPSE OF THE BUILDING. THIS INTERN CAN HELP TO: ELIMINATE THE BUILDING OWNERS LIABILITY AND RISK PREVENTION OF DEATH FROM FIRE AND SMOKE INHALATION REDUCE THE POSSIBLE RISK TO THE FIRE FIGHTERS REDUCE THE RISING COST OF INSURANCE POLICES PROTECT CAPITAL INVESTMENT

'FIRE PROTECTION SOLUTIONS FOR EVERY SITUATION' WE ONLY SUPPLY AND INSTALL SYSTEMS THAT COMPLY WITH BS OR EN STANDARDS PROVIDING UP TO 4 HOURS FIRE PROTECTION Sizewell B Nuclear Power Station to Vasilikos Desalination Plant, Millenium Dome (O2 Arena) to THOK Theatre Nicosia, Heathrow Airport to Larnaca Airport, King s Cross Underground Station to Kings Avenue Mall Paphos, MTV Studios London to KPMG Limassol, Canadian High Commission London to WARGAMING Nicosia, The rebuilding of Berlin after the wall came down to the rebuilding of Vasilikos Power Station in 2012. What do all of these projects have in common? FTI MARNEROS Serving the Passive Fire Protection Industry for over 25 Years

fire stopping solutions for every situation Supplied & Installed Systems Up to 4 hours with BS or EN Certification Fire Compound Forms a load bearing high thermal insulating fire seal to prevent the spread of fire and smoke through openings in fire rated walls and floors. When installed around fire damper units, the excellent strength and shear resistance of fire compound ensures that the installation frame will be retained in the wall or floor, if the ductwork should collapse, even if the damper frame is not fixed to the structure. Fire Batt Barrier Are designed to prevent the spread of fire and smoke through openings in fire rated walls and floors where openings are formed to allow the installation of multiple building services, fire batts will also maintain the acoustic performance of the wall or floor. Fire batts consist of a dense wool core between 140kg/m3 to 160kg/m3 and are coated with an ablative coating which reduces the permeability of the stone wool preventing the passage of hot gases. Fire Collars & Pipe Wraps Designed to protect plastic pipes that pass through fire rated walls and floors. Pipe collars are fixed to the substrate after the walls or floors have been completed. Pipe wraps are placed around the plastic pipes before the walls or floors are completed. Both systems provide a quick and easy solution to prevent the passage of fire and smoke which is often overlooked. Fire Rated Movement Joint Seals Movement or expansion joint strips are highly compressible, flexible, fire resistant seals which are used where movement joints are formed in the structure of a building. The fire performance of movement and expansion joint strips will vary depending on the particular application and orientation. The simple compression fit with no mechanical fixing gives the optimum speed of application.

fire stopping solutions for every situation Intumescent Mastic We use both acrylic and silicone intumescent mastic depending on the type of fire protection required and the location within the building. It can be used in door frames, movement and construction joints, sealing and bonding of Fire Batts, top of walls and many other scenarios. Most acrylic intumescent mastics are over paintable and fungus resistant.. Slab Edge Fire Stopping Provides solutions for fire, smoke and sound barrier requirements in all cladding panels and curtain wall applications. The primary function is to maintain continuity of fire resistance by sealing the gap between fire compartment floors and walls both horizontally and vertically. Trapezoidal Deck Infills It is necessary to fire stop the trapezoidal deck infills above fire walls where the fire compartmentation can be breached. It is also used to increase the fire protection of a 3 sided fire protected beam. Intumescent Fire Pillows We install intumescent fire pillows to provide mainly temporary and in some cases permanent fire protection from the spread of flame. The intumescent fire pillows maintain the fire resistance of floors and walls where openings for services are located. They are most suitable for installing around cables which need to be regularly moved or changed.

Structural Fire Protection of Steel, Internal Walls and Ceilings Intumescent paints to Structural Steel Provides fast on-site and off-site fire protection for structural steel up to 2 hour fire rating. The initial primer coat is applied by the steel fabricator after blast cleaning the steel. In C1 environments, top coat is not required unless a decorative colour for visible steels is preferred by the project architect. Fire rated board Systems for Structural Steel The boards come in various materials such as Rockwool, Gypsum and Calcium Silicate and provide up to 4 hour fire protection. Calcium Silicate type fire boards provide a solution for Hydrocarbon oil fires such as fuel terminals and tunnel linings. Fire Walls From light weight gypsum walls to high performance reinforced cement bonded to steel sheets on both outer surface cover the full range of solutions for every project. These systems maintain the fire compartmentation and provide up to 4 hours fire resistance. Fire Ceilings We install various types of fire ceilings from fixed gypsum or calcium silicate boards to fire rated removable ceiling tiles, all systems provide up to 2 hours of fire protection and excellent insulation and acoustic upgrades.

General Fire Protection of Smoke Extract Ducts, Doors & Curtains Smoke Extract Ducts Fire Protection The on site installation of specialist intumescent paint to provide up to 2 hours of fire protection is a fast and cost effective solution for pre installed galvanised ducts. We also supply and install self supporting fire rated ducts made from Calcium Silicate or Durasteel boards with no need for galvanised ductwork. Automatic and Fixed Fire Curtains Automatic fire curtains are fire-resistant roller barriers that remain invisibly retracted until activated by an alarm signal, at which time they descend safely to their operational position. Fixed fire curtains are installed in ceiling voids or roof spaces. Wood & Steel Fire Doors Buildings are compartmentalised to delay the spread of fire and smoke from one area to another. These compartments are usually linked by fire doors to allow the flow of traffic around the building. Fire Doors have two important functions, when closed they form a barrier to stop the spread of fire and smoke, when opened they provide a means of escape. Fire & Smoke Air Transfer Grilles Allow air to pass freely between fire doors and walls. The slats and framing swell to many times their thickness in the event of a fire, fusing together to form a non-combustible mass which prevents the passage of hot smoke and gasses.

INDUSTRY CERTIFICATION QUALITY ASSURANCE IFC Certification Ltd (International Fire Consultants) is a UKAS accredited and internationally recognised provider of high quality and customer focused third party certification We are members of the Association of Specialist Fire Protection (ASFP) Also, our in-house Fire Protection Assessors with over 25 years of experience trains all operatives to the standard of Passive Fire Protection Installations NVQ/City&Guilds Level 2

SELECTIVE BRANDS For over 30 years, Coopers innovation and commitment to developing industry leading fire and smoke curtain has led them to become the designers preferred fire and smoke curtain manufacturer and installer. Furthermore, they also have third party certification which no one else has and are true gravity fail safe. http://www.cooperfire.com Nullifire is the leading developer of intumescent fire protective coatings in the UK and Europe and has pioneered the use of this technology for over 30 years to offer trusted, life-saving solutions to protect steel structures and timber surfaces; service penetrations; and construction movement joints. http://www.nullifire.com As a market-driven solution provider, Promat UK is the acknowledged leader in the business of passive fire protection and high performance insulation. Promat UK is a subsidiary of Promat International, part of Etex, a Belgian industrial group manufacturing and marketing high quality building materials and insulation systems. http://www.promat.co.uk Endoors srl. was established in 2005 to operate in the production of fire rated metallic and multipurpose doors and the trade of related products. Having established a national presence, the company has steadily expanded into foreign markets. http://www.endoors.it FSi are a Manufacturer and Developer of a full range of Built-In Fire Protection Systems. The keyword here is systems and not products; it is paramount that systems are installed as it is the only way that fire performance can be properly upheld. All solutions are made under strict ISO9001 factory guidelines and with the utmost efficiency. http://www.fsiltd.com

the art of passive fire protection since 1989 by FTI-MARNEROS LTD For Direct Professional Technical Advice: Call our Fire Assessor Phivos Petrou on +357 99006089 or email: fti@marneros.com FTI MARNEROS LTD 7, Koutsoventi, 4101, Limassol Cyprus, Tel: +357 25727055