SUBMITTAL DATA. Medbrooke ADD. Stuart Mc Munn Company 137 North Sixth Street Clarksburg, WV for. Prepared for

Similar documents
Roof Top Packaged Unit (RTU-1) Specification

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Summary Page

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13


Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

SUBMITTAL SCHEDULE & DATA

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

48PGD/E/F/L/M/N PG20-28

DCG Commercial. Submittal Data Form

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

SKYPAK II, 3 Ton Series, gives you a

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data Performance Data Electrical Data

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

SKYPAK II, 3 Ton Series, gives you a

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

62DA,DB,DC,DD,DE,DF07-38

Guide Specifications for InRow Direct Expansion

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Ruud Commercial Achiever Series Package Gas Electric Unit

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

48TM GAS HEATING/ELECTRIC COOLING UNITS

Rheem Commercial Classic Series Package Gas Electric Unit

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

Ruud Commercial Achiever Series Package Gas Electric Unit featuring HumidiDry Technology

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

Multi-Path RTU-TYPE 2

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

13 GEP A L P - 1 A

SKYPAK II Heating & Cooling Self Contained Packages

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

INSTALLATION INSTRUCTIONS

Report No CRT-414

Commercial Packaged Rooftop Systems

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

RT-OA TM Rooftop Outdoor-Air (DOAS)

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

50TJM Nominal Cooling Capacity Tons HFC R - 410A Refrigerant

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

RGE 13 A T - 1 A

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

C13-Series Engineering Guide

Now In Production JULY 2008

Advance Release September 2009

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

PAJ3. Product Specifications

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

4YCC3048A3096A /3/ /

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

48TF GAS HEATING/ ELECTRIC COOLING UNITS

Commercial High-Efficiency Condensing Units

TAG: RTU-2B 3B 4B 5B 6B 7B 1E MODEL: QTY. (7) 48TCED14A3A5-0B0A0 PACKAGED GAS/ELECTRIC ROOF TOP UNITS

Wall Mounted Air Conditioners with Gas Heat Models AVGA

Commercial High-Efficiency Condensing Units

R-410A LUXAIRE ACCLIMATE DYX MODELS 2-4 TON 60 Hertz

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

VertiCool Aurora Engineering Guide

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MACH N-407 Heat Pump Air-Cooled Chiller

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

Ruud Commercial Value Series Package Gas Electric Unit

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

Ruud Commercial Value Series Package Gas Electric Unit

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

KIC Air Curtains. Technical Guide

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

ELECTRICAL QUANTITY WEIGHT (LB)

SR SERIES WATER SOURCE HEAT PUMP SYSTEM SELECTION AND OPTIMIZATION GUIDE

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

Packaged Rooftop Air Conditioners Precedent - Cooling, Gas/Electric, Heat Pump 3-5Ton Standard and High Efficiency 3 Phase Rooftop Units

Roof Top Units - RTU-1/2/3/4

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

Transcription:

SUBMITTAL DATA for STOCK ROOFTOP UNIT AS ORDERED - PLEASE CHECK AND SIGN AS APPROVED Prepared for Stuart Mc Munn Company 137 North Sixth Street Clarksburg, WV 6301 Customer PO#: 38 Prepared by Mason and Barry Inc 301 Smiley Drive Saint Albans, WV 5177 1 of 13

Job Information Technical Data Sheet STOCK UNIT ADD Medbrooke Matt Duncan 04.50 RTU CO#1 Job Name Date Submitted By Software Version Unit Tag Unit Overview Model Number Voltage Design Cooling Capacity MPS010B 460/60/3 15738 Btu/hr AHRI 360 Standard EER IEER 11. 11.9 ASHRAE 90.1 010 Compliant Unit MPS010B Cooling, Standard Natural gas heat Hot Gas Reheat Constant volume 0 ft culus Model Number: Model : Heat : Hot Gas Reheat: Application: Altitude: Approval Physical Unit Dimensions and Weights Unit Length Unit Height Unit Width Unit Weight 93.7 in 44.0 in 58.7 in 1165 lb Unit Construction Powder Coat Galvanized Exterior: Doors: 3/4" foil face with mechanical fasteners, R value of 3.6 Single wall construction Insulation: Liners: Drain Pan Material Fan, Filter, Coil, Control Panel, and Economizer section Polymer Unit Electrical Data Voltage SCCR MCA MROPD 460/60/3 V 5 kaic 8.0 A 35A Return/Outside/Exhaust Air Outside Air Option : Factory Installed Econ, vertical return, DDC Controls Draw Through Filters ft² Face Velocity ft/min Air Pressure Drop inh₂o " Disposable 13.5 96 Included In Fan Performance 9 of 13

Cooling Coil Fins per Inch Rows ft² Face Velocity ft/min Air Pressure drop inh₂o 18 3 13.5 96 Included In Fan Performance Cooling Performance Btu/hr Sensible Capacity Btu/hr 15738 96908 Entering Air Temperature Dry Bulb Wet Bulb 80.0 Leaving Air Temperature Dry Bulb Wet Bulb 67.0 57.6 Ambient Air Temp 57.0 95.0 Hot Gas Reheat Coil Section Air Pressure Drop Entering DB Leaving DB Aluminum Tube Micro channel 5.9 ft² 0.4 inh₂o 4577 Btu/hr 57.6 68.0 Control : On Off Control Fan Section Fan Wheel Diameter Quantity Vibration Isolation FC 15 in 1 Rigid Fan Performance Air Flow External Static Pressure Design Fan Speed Drive Package Speed Brake Horsepower Altitude 4000 CFM 1.00 inh₂o 1043 RPM 894.9 HP 0 ft Motor Horsepower Full Load Current 3.0 HP Open drip proof, EPAct 80.0 7.0 A Drives Service Factor Adjustable Sheave 10% Gas Heat Section Material Gas Ignition Combustion Blower Heat Stages Tubular Heat exchanger with in shot burner manifold Aluminized steel Natural Gas Electric Induced draft blower Stage Heating Performance Input Size Steady State Entering Air Dry Bulb Leaving Air Dry Bulb 5 MBH 1850 Btu/hr 81% 60.0 10.0 10 of 13

Condensing Section Compressor Quantity Total Power Capacity Control Refrigerant Scroll 9.1 kw steps R410A Compressor Amps: Compressor 1 Compressor 8.6 A 8.6 A LP, HP switch Compressor Options: Condenser Coil Fins Per Inch Rows Fin Material Refrigerant Valves Copper tube Aluminum None Condenser Fan Motors Number of Motors Full Load Current 0.7 A AHRI 360 Certified Data at AHRI 360 Standard Conditions Net Capacity 118000 Btu/hr 11. EER ASHRAE 90.1 11.9 IEER 010 Compliant Internal Static Pressure Drop Calculation 1.00 0.35 External Static Pressure: Internal Static Pressure: 1.35 inh₂o Total Static Pressure: Options Electrical Field Connection: Power Options: Power Block None Controls Temperature Controls: DDC controls, no BAS communication card Warranty Parts Warranty: Compressor Warranty: Heat Exchanger Warranty: Standard one year Standard five year Standard ten year AHRI Certification All equipment is rated and certified in accordance with AHRI 340/360 Notes As a standalone component, unit meets or exceeds the requirements of ASHRAE 90.1.010. The approving authority is responsible for compliance of multi component building systems. 11 of 13

M MPS 006 01 1 gas heat Drawing fo or RTU CO#1 1 MPS 0006 01 gas heat_drawing for RTU CO#1 Product Draw wing Unit Tag: RTU U CO#1 Product: Model: MPS010 0B Project Name: D Sales Engineer: Jan. 06, 015 Sales Office: Masson & Barry, Inc. Ver/Rev: Sheet 1 of 1 13600 Industrial Park Blvd. Minneap polis, MN 55441 Softwaare Version: 04.50 www.daikinapplieed.com Scale: NTS Toleerance: +/ 0.5 Dwg Units: in [mm] No change to this drawing may be made unless approve ed in writing by Daikkin Applied. Purchaaser must determinne that the equipment is fit and sufficient for the job specifications. J J 1 1 of 13 Prrepared Date: