EARTH LEAKAGE RELAY. User Manual - Issue 1.0

Similar documents
Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

CMD420 / CMD421 Series

MO n : 12JMC rév A

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

CTT8 TEMPERATURE MONITOR DEVICE

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

OPERATING INSTRUCTIONS COP-IE, COP-I, COP-E (ANSI 50,51,50N,51N)

Temperature Controllers

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

38-SDMS-03 SPECIFICATIONS FOR LV DIGITAL PANEL METERS

1.7. Insulation fault evaluators EDS460/490 EDS461/491

7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities.

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

1.7. Insulation fault evaluators EDS460/490 EDS461/491

REA 105 Arc Protection Module. Operator s Manual

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

Insulation fault evaluator EDS460-DG

MODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

M15051) INSTRUCTION MANUAL

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

Room thermostats with LCD for wall mounting

OPERATING INSTRUCTIONS COP-F (ANSI 81O/81U)

Reyrolle Protection Devices. 7PG26 DAD High Impedance Current Relay. Answers for energy

Universal controller for panel mounting Models CS6S, CS6H, CS6L

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

RCMA423-DM RCMA423-DM1C RCMA423-DM2C RCMA423-DM3C. Operating Manual

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

MSP1000 Motor Protection Relay

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Analog Annunciator Unit SACO 16 A3. Product Guide

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

VAMP 120 & 121. Arc flash detection units. Product picture

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

Delta XRD. Supervision Relays. rms A U X I L I A R Y T R I P P I N G S U P E R V I S I O N

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Operation and use. Functions and characteristics

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Remote alarm indicator and test combination MK2430

SENTINEL A - Fault Passage Indicator

Moulded case circuit brakers

Item Number Description Price. Accessories " Diesel/Water/Waste tank sender $ Battery temperature sensor $2.22

SENTINEL D - Fault Passage Monitoring

Numerical Relay MELPRO TM -S Series

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

LINETRAXX RCMS460-D/-L RCMS490-D/-L

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

LC2200 Level Controller Installation and Maintenance Instructions

SET Installation and Operating Instructions. Level switch for one sensor

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Instructions for the fan motor control system, SILVER C

Installation Manual Tracker 221

Monitoring Devices 11/1

ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on 24 V supply lines for medical locations SELVTESTER-24

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection

User Manual. Power Distribution Unit. Version: 1.0

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

M2500 Engine Controller Installation Manual

Welcome to Hager Presentation

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

Process & TeMPerATUre UniversAl input DigiTAl MeTers

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Table of Contents. Protective Relays

DIGITAL ALARM UNIT Model ALU-AP

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

General Routing Interface

Room Temperature Sensors

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

Low Temperature Zirconia Oxygen Analyzer

SET-2000 Hi Level/Oil

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

RE-PR3-E-27 3-Phase Panel Mount 27kW

02/11/2015

DKG-108 POWER FACTOR CONTROLLER

D5100 Industrial Differential Pressure Transducer

PMD-MXT -XX -XXX. Ordering Example. Model Input Channels Input Type. THC Thermocouple channels channels channels RTD RTD

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

Overload relays. General descriptions. Configuration of the front

BENDER A-ISOMETER IRDH265 IRDH365

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Spectron LSN (Life Safety Network) Suggested Specifications

MW Pince courant de fuite Leakage current Clampmeter. Notice d utilisation User s Manual M3950M00

Transcription:

Earth Leakage Relay www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters EARTH LEAKAGE RELAY User Manual - Shunts Digital Multimeters Clamp Meters Insulation Testers SUBJECT TO CHANGE WITHOUT NOTICE This manual superseded all previous versions please keep for future reference

Earth Leakage Relay Features True RMS Measurement Stores last 15 faults Detection of fault with display of parameter value Trip relay DPM USB configuration with PRKAB with PRKAB 4 digit 7 segment LED display 1. Applications Leakage protection for: Control panels and switch boards Sensitive environment like chemical plants, Oil refiners Generators, utility power monitoring, Transformers, Motor Mining and control Engineering 2. Product Features Leakage current monitoring in 1 & 3 phase system User selectable power on delay, Reset delay, Trip Delay, Alarm delay Front side Test & Auto / Manual Reset function 4 Digits ultra bright LED Display User selectable password protection Trip relay cum DPM with class 2FS(full scale) True RMS measurement The instrument measures distorted waveform up to 15 Harmonic LED indication - LED indication for relay-1, relay-2 status - LED indication for CBCT Open fault - LED indication for Pre-alarm and Alarm - Trip indication are displayed on 4 Digit display Previous fault Storage Instrument memorizes the last 15 fault occurred. USB Configuration with PRKAB Simply configure the RISH RELAY using USB interface. Onsite selection of Auto scroll / Fixed Screen User can set the display in auto scrolling mode or fixed screen mode using front panel keys. Auto / Manual reset In auto mode instrument automatically clears itself. If the device set into manual mode, then device must be reset manually by push button. Adjustable set point for - Leakage Current - Alarm Adjustable time delay for Alarm - Leakage Current - Mining and control Engineering - Leakage protection for - Power ON - Reset Trip or Buzzer mode Relays can be used in Trip mode to protect the system or in Alarm mode to control the Alarm. User selectable Input rated current The input rated current of CBCT can be programmed on site as 0.03A to 30A using front panel keys. Compliance to International Safety standards Compliance to International Safety standard IEC 61010-1 - 2010 EMC Compatibility Compliance to International standard IEC 61326 EARTH LEAKAGE RELAY 1

3. Dimensions 4. Technical Specifications Input Current: Nominal Primary input current 0.03 Amp to 30 Amp Maxcontinuous input current 110% of rated value Auxiliary Supply: Auxiliary Supply Voltage 60V 300V AC-DC Aux supply frequency 45 to 66 Hz range Overload Withstand: Current 20 x for 1 second, repeated 5 times at 5 Minute Operating Measuring Ranges: Current Range 10mA - 30A Frequency 40...70Hz VA Burden: Input current burden < 0.25 VA approx. per phase Auxiliary supply burden < 4 VA approx for AC aux. < 4 W approx for DC aux. Reference condition for Accuracy: Reference Condition 23 C +/- 2 C Input waveform Sinusoidal (distortion factor 0.005) Input Frequency 50 or 60 Hz ±2% Auxiliary supply voltage Rated Value ±1% Auxiliary supply frequency Rated Value ±1% Accuracy: Input Current ±5% of setting of input range Power ON,Trip, Reset, Alarm, ±5% of Set Delay or ± 100 msec. time delays (whichever is greater) Frequency ±2% of input frequency Influence of Variations: Temperature coefficient : 0.05%/ C (for rated value range of (50...100% of rated value) use (0 50 C)) Mechanical Attributes: Weight < 250g Aprrox EARTH LEAKAGE RELAY 2

5. Electrical Connection Applicable Standards: EMC IEC 61326 Immunity IEC 61000-4-3. 10V/m min Level 3 industrial Low level Safety use IEC 61010-1-2010, Permanently connected IP for water & dust IEC 60529 Pollution degree: 2 Installation category: 300 V CAT III / 600 V CAT II High Voltage Test 2.2 KV AC, 50Hz for 1 minute between all Electrical circuits Environmental: Operating temperature -25 to + 55 C Storage temperature -30 to + 70 C Relative humidity 0... 95% non condensing Warm up time Minimum 3 minute Shock 15g in 3 planes Vibration 10... 55 Hz, 0.15mm amplitude Enclosure IP20 (front face only) Relay Contacts: Types of output 1CO, 2CO, 1CO+1CO Contact Ratings (Res. Load) 8A/250VAC/30VDC Mechanical Endurance 1x10^7 OPS Electrical Endurance NO- 3x10^4 OPS for 1CO / 1CO+1CO relay NC- 1x10^4 OPS 1x10^5 OPS for 2CO relay EARTH LEAKAGE RELAY 3

6. Operating Elements 1/2 Relay-1 and Relay-2 status LED : Indicates status of relay-1 and relay-2 respectively 3 4 Digit ultra bright 7 seg LED Display. 4 Indicates status of CBCT. 5 Indicates the status of voltage input. (In case of model with two CBCTs (5) indicates status of 2nd CBCT.) 6 Indicates the status of current input (Case (6) is only applicable to model with CBCT, current and voltage input.) 7 Enter Key : Confirms changes of parameter setting. When on the measurement screen, holding for 3 sec enters in setup menu 8 Test Key : Increments setting value, move upwards in the menu or change parameter. It is also used to test operation of relay. Continuous holding of test key changes relay position and when release it resets the relay position (Only in healthy condition). 9 Reset Key : Decrements setting value, move downwards in the menu or change parameter. It is also used to reset relay when manual reset mode is selected. 10 USB configuration with PRKAB. Parameters like CT ratio, PT ratio trip settings can be configured. 7. Parameter Settings Parameters ELR Rated current 0.03 Amp to 30 Amp Nominal Frequency 50 / 60 Hz Trip setting for earth leakage current 0.03 Amp to 30 Amp Trip setting for Differential / Hysterisis 1-15%* Trip setting for alarm 50% to 99% of set value Programmable Delay for Earth Leakage Current 0.1-30 Sec Programmable Delay for Power On 0.5-30 Sec Programmable Delay for Automatic Reset 0.2-30 Sec Programmable Delay for alarm 0.1-30 Sec Reset option Auto / Manual Relay control mode Energise / De-energise EARTH LEAKAGE RELAY 4

8. Ordering Information Model Name ELR ELR + ELR V ELR VI Description ELR with single CBCT input ELR with two CBCT inputs ELR with one CBCT input and one voltage input ELR with CBCT, current and voltage input(one each) Model Name 1 CO 1 CO + 1CO 2 CO ELR 4000 4001 4002 ELR + X 4011 X ELR V 4020 4021 4022 ELR VI X 4031 X Auxiliary supply voltage Order code 60-300V AC DC +/- 5% HA 24-60V AC DC +/- 5% LA Communication interface Description With PRKAB Z ELR PLUS Y X: not applicable Order Code Example: ELR - 4021-Z-HA ELR V with 1CO + 1CO,higher auxiliary supply and PRKAB EARTH LEAKAGE RELAY 5

Contact Sifam Tinsley Instrumentation Ltd 1 Warner Drive Springwood Industrial Estate Braintree, Essex CM7 2YW Tel: 01376 335271 E-mail: sales@sifamtinsley.com www.sifamtinsley.co.uk EARTH LEAKAGE RELAY 6