Certificate of Conformity Certificate num. Registration date Version Valid until Number Issue date

Similar documents
Certificate of Conformity Certificate num. Registration date Version Valid until

Certificate of Conformity Certificate num. Registration date Version Valid until Number Issue date

Certificate of Conformity Certificate num. Registration date Version Valid until Number Issue date

Hochiki Devices. It also highlights any specific requirements and technical information.

Certificate of Conformity Certificate num. Registration date Version Valid until

Certificate of Conformity Certificate num. Registration date Version Valid until

APPLICATION NOTE. Document Type. Application Note. Document Title. Date January Version DS0167/Iss 2. ESP Technical Summary

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

ZXSe Range Data Sheet

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

COMPANY OVERVIEW Company Overview Commencing operations in 1999, Incite Fire has quickly become a leading supplier quality fire detection products and

The EN54 Part 2 & 4 Fire System

Wireless Fire & Security Solutions. Fire Product Showcase

An introduction to... Sigma

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Advanced FireAlarm Panel 1-4Loop

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

FIRElux Emergency Lighting

Electronics Ltd. Life Safety System Specialists

The EN54 Part 2, 4 and 13 Fire System

Wireless Fire & Security Solutions. Fire Product Showcase

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Solution F2. Fire Alarm Control Panels one step ahead.

Intelligent addressable fire alarm control panel

Eurofyre Limited range of ProFyre C24 Control and Indicating Equipment (refer to attached appendix for details and conditions) Certification Manager

FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

Reliably Advanced Extinguishing Control

The Kentec driver connects to the Kentec Syncro range of fire detection panels. Available for Commander and ObSys.

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

SUPREMATouch Modular Fire & Gas Detection System

Touch Screen 1 loop Addressable Fire Alarm Panel

Addressable and Conventional Fire Protection

Reliably Advanced Extinguishing Control

Consultant Specification AGILE Wireless Fire Detection System

Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide.

For Complete Fire and Gas Solutions

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

Planning Instructions MEW01472 Revision -

Fire detection and alarm systems. Part 4: Power supply equipment (ISO :2003, MOD) AS (Incorporating Amendment No.

Solution F1. Fire Control Panels the new generation

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

Fire control panels FC726 FC726-XA

A Guide To BS Understanding the selection, spacing and siting of detectors

Fire control panels FC360

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

Excel-EN Conventional Fire Control Panel

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

Certificate of Product Approval

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

CONTROL PANELS. Tech Data Sheet D01688GB1 10/2012 Fire Detection. Control Panels of the FX 3NET (ALC) Fire Detection System

Syncro AS. Analogue Addressable Fire Control Panel. Product Manual

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

Fire control panel detect 3004 plus and accessories

On the job around the clock 24/7: Fire detection systems

TrueAlarm Fire Alarm Controls

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

Intelligent Security & Fire Ltd

Certificate of constancy of performance,

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Process Alarm Solutions

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Planning Instructions MEW01090 Revision 4

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Australian Standard. Functional safety Safety instrumented systems for the process industry sector

Fire and Gas Monitoring Panel ST7-HV

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

VIGILANT MX1-Au Fire detection and alarm system Engineer s Specification

SUPREMATouch. Modular Fire & Gas Detection System

Touchpoint Pro Flexible Gas Control System

Intelligent Addressable Fire Alarm System

LaserFOCUS VLF-250 Engineering Specification

Planning Instructions MEW01776 Revision -

Sita200plus. 200detectors. Single loop analogue addressable System

The EN54 Part 2 and 4 Fire System

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

Added password for IP setup page : Password must be in IP format!

Intelligent Security & Fire Ltd

Precept Marine Control Panel Application Guide

Fire and Smoke Control Systems

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

General Routing Interface

Saxon Range 1-8 Zone Convertional Control Panels

SUPREMATouch. Modular Fire & Gas Detection System

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Vigilant MX4428 Fire Alarm System

Intelligent Single Loop Fire Alarm Control Panel

ConfigManager PLUS. Fire Alarm Control Panel MAN Programming Software for FireFinder PLUS

MX4428. Addressable Fire Alarm System. Features. Advantages & Options

Product Catalogue. Intelligent Control Equipment for Life Safety. Issue 1

RTD TEMPERATURE SENSING SYSTEM

Written by: A.C. Amended by G.G. Checked by: JBJ/PB Approved by:jbj

Different types of Fire Alarm System

ID2000. intelligent fire alarm panel

2004 AUSTRALIAN STANDARDS UPDATE

INTELLIGENT FIRE ALARM CONTROL PANEL

Transcription:

CSIRO Verification Services Clayton, Victoria, Australia +61 (0)3 9545 2777 http://www.activfire.gov.au/ Page 1 of 5 Taktis, TS Series, fire control panels Issued by Product designation (Refer to the Schedule/enclosures for further specified details) Agent/distributor Incite Fire Block Y, Unit 1, Regents Park Estate, 391 Park Road, REGENTS PARK, NSW, AUSTRALIA, 2143 Registrant Kentec Electronics Limited Units 25-27 Fawkes Avenue, Questor, DARTFORD, KENT, UNITED KINGDOM, DA1 1JQ Producer Kentec Electronics Limited Units 25-27 Fawkes Avenue, Questor, DARTFORD, KENT, UNITED KINGDOM, DA1 1JQ Conformance criteria and evaluation The Taktis, TS Series, fire control panels have been evaluated and verified as conforming with the relevant requirements of the following criteria. 1. Australian Standard AS 7240.2-2004, 'Fire detection and alarm systems - Part 2: Control and indicating equipment (ISO 7240-2:2003, MOD)'. 2. Australian Standard AS 7240.4-2004, 'Fire detection and alarm systems - Part 4: Power supply equipment (ISO 7240-4:2003, MOD)'. 3. Australian Standard AS 4428.3-2010, 'Fire detection, warning, control and intercom systems - Control and indicating equipment - Fire brigade panel'. Limitations/conditions of conformance Limitations/conditions of conformance, where identified on this certificate, are derived from qualifications from evaluation(s) for conformity and/or other related technical documentation. All details with respect to design, assembly and installation instructions and restrictions should be checked against the producer's current technical manual/data sheets and the requirements of the Authority having Jurisdiction. Specified limitations/conditions, determined from the evaluation for conformity, include the following. i. Compatibility of this equipment with new or existing actuating devices should be verified prior to installation. This certification is issued within the scope of CSIRO Verification Services Rules governing ActivFire Scheme and is valid only for the product(s) as submitted for evaluation and verification of conformity, subject to the following conditions. Reference to details, limitations and requirements, where documented as a schedule/enclosure with this certificate. The Registrant is responsible for their attestation of conformity and ensuring that on-going production complies with the conformance criteria defined in this certificate. This certificate will not be valid if any changes or modifications are made to the product which have not been notified and validated by CSIRO Verification Services. This certificate is subject to periodical re-validation upon verification that all requirements, as determined by the conformity assessment body, continue to be satisfactorily met by the Registrant. This certificate may only be reproduced in its published form, without modification and inclusive of all schedules/enclosures. Any changes, errors or omissions, must be submitted in writing and if necessary or requested, substantiated with relevant evidence. Any representations, such as advertising or other marketing related activities or articles shall reflect the correct contents of this certificate and conform with all relevant trade practices.and consumer protection legislation and regulations. Any terms or conditions of use as applicable to content and documentation as published or accessed through web sites administered by the CSIRO Verification Services. David Whittaker Executive Officer ActivFire Scheme CSIRO Australia, 2018 This certificate remains the property of CSIRO and may be subject to amendment, suspension or withdrawal at any time. The validity and authenticity of this certificate can be verified by the certification register located at http://www.activfire.gov.au

Page 2 of 5 Producer's description The Taktis, TS Series, fire control panels form a central part of a fire detection and alarm system using the Hochiki Enhanced Systems Protocol (ESP). This equipment CIE contains an integrated AS4428.3 2010 Fire Brigade Panel (FBP) The Taktis, TS Series, fire control panels combine the latest hardware and software to produce a control and indicating system, which is powerful and sophisticated, yet simple to use This equipment incorporates an intuitive large robust 7 800 x 480, full colour graphical display with resistive touch screen functionality which delivers information on the status of the fire alarm system and enables full control. All field wiring can be connected to a passive motherboard enabling addition, reconfiguration or replacement of all electronic hardware without the need to disconnect any field wiring. This modularity also enables each panel to be customised with addressable loop detection circuits, conventional circuits, relay cards, additional sounder outputs or programmable I/O modules as required These modules include: 2 Loop addressable Hochiki ESP protocol board 8 zone conventional detection board 4 way sounder output board 8 way relay board 16 channel programmable I/O with digital inputs and open collector outputs o Media Gateway communications board Provides the means to communicate with any system and transmit real information back to a dedicated server A Bridge Network Card (connecting this equipment to existing Syncro networks) Loop Explorer 2 configuration software provides a familiar, simple to use PC application with the power to produce the most complex configurations via an easy to use interface. This equipment monitors inputs and activates the required outputs via panel front end configuration or cause and effect of the LE2 configuration software. Fire, Fault, Alert, Transparent, Technical Alarm, Security etc are a configured built menu along with AVF, Hotel Mode and AAF facilities. Technical specification The following details are a representative extract of the technical specification for the Taktis, TS Series, fire control panels and may be subject to change. Complete and current details should be determined from the designated producer s technical manual/data sheets. Schedule of variant designations The following is a schedule of validated variant designations of the certified/listed equipment. Type Model Variant Ident. TS2 TS3 Includes door? Description Schedule of optional functions with requirements Enclosure/cabinet dimensions H 710 mm x W 500 mm x D 150 mm Enclosure/cabinet dimensions H 1065 mm x W 560 mm x D 228 mm The following schedule of AS 7240.2 2004 optional functions with requirements have been validated. 1. Indications: a. Alarm counter (Cl. 7.13) b. Fault signals from points (Cl. 9.3) 2. Controls: a. Delays to outputs (Cl. 7.11) b. Dependency on more than one alarm signal (Cl. 7.12) c. Disabled condition (Cl. 10) d. Disablement of each addressable point (Cl. 10.5) e. Test condition (Cl. 11)

Page 3 of 5 3. Outputs: a. Output to fire alarm devices (Cl. 7.8) b. Control of fire alarm routing equipment (Cl. 7.9) c. Output to fire protection equipment (Cl. 7.10) d. Output to fault warning routing equipment (Cl. 9.9) 4. Operational a. Impact (operational) (Cl. 16.6, Annex ZA2: not optional) b. Vibration, sinusoidal (operational) (Cl. 16.7, Annex ZA2: not optional) 5. Marking requirements (Cl. 15, Annex ZA2: not optional) The following schedule of AS 7240.4 2004 optional functions with requirements have been validated. 1. Battery function check (Cl. 5.5) 2. Marking (Cl.8, Annex ZA2: not optional) 3. Impact (operational) (Cl. 9.7, Annex ZA2: not optional) 4. Vibration, sinusoidal (operational) (Cl. 9.8, Annex ZA2: not optional) 5. Vibration, sinusoidal (endurance) (Cl. 9.11, Annex ZA2: not optional) 6. Marking requirements (Cl. 15, Annex ZA2: not optional) Schedule of properties/characteristics The following schedule is an extract of physical and operational properties/characteristics of the certified/listed equipment. Model TS2 TS3 of loops 2-8 Loop Protocols Hochiki Enhanced Systems Protocol (ESP Protocol) Zonal fire indicators Up to 2000 per panel Networking 128 panels (115200bps) Auxiliary indicators Via additional touch screen display Display 7 full colour TFT LCD, 800 x 480 with resistive touch screen Addressable Points 127 Per Loop + 127 Sounder bases 2032 Addressable Points Max per panel Sub-addresses per panel 6400 (400 per loop) Addressable point text 80 characters Zone name text 80 characters Sounder outputs/rating Sounder x 4 24 Vdc @ 2.5 A, programmable for continuous power, synchronisation and power-drop on reset AUX 24V supplies AUX 2 x 24 Vdc fused at 500 ma Total C&E entries 50000 RS485 Expansion Cards 32 Programmable I/Os 512 Programmable I/O per panel Connection to PC USB type A & B Maximum loop current 400mA Power supply 10.25A Max batteries 28 Ah 40 Ah Programmable relays 2 Programmable relay 1 Volt free contact rated at 30 V, 1 A Fire relay Fire relay Volt free contact rated at 30 V, 1 A Alarm relay Alarm relay Volt free contact rated at 30 V, 1 A Fault relay Fault relay Volt free contact rated at 30 V, 1 A Programmable inputs 3 Programmable Inputs Programmable buttons 24 configurable via Loop Explorer Ancillary serial ports 2 configurable Event log/resolution 99999 at 1 second Inverted inputs and outputs Marine approvals AAF, Hotel modes, AVF

Schedule of components and/or assemblies The following is a schedule of validated components and/or assemblies of the certified/listed equipment. Description Board/Part No Issue/Rev/Version 10.25A Power Supply S408 Issue 10 LCD Main Processor Board S721 Issue H Taktis Main Back Board S722 Issue 1 Taktis Ethernet (Taktis Network/FAM/Ethernet) S723 Issue E Taktis Dual Loop Board S758 Issue F Taktis System Board A Module S769 Issue C Taktis System Board B Module S770 Issue D Zone LED board S771 Rev 3 Taktis Visio (SAM) Board S787 Rev B Main Program Software - RC_01_00_000_AU Page 4 of 5 Taktis Series designation Description Type ALN-ASN ATJ-ASN ACC-ASN ACD-ASN CO multi sensor ALK-ASN ACA-ASN ACB-ASN/ACB-ASNW Sensors ALG-AS ALK-AS ACA-E ACB-AS / ACB-ASW FB-1 FIREbeam CHQ-SZM2 Single zone monitor CHQ-DIM2 Dual switch monitor CHQ-DSC Dual sounder controller CHQ-DRC2 Dual relay controller CHQ-DZM2 Dual zone monitor CHQ-MRC2 Single input/output device Modules CHQ-PCM Plant Control Module CHQ-POM Powered output module CHQ-SIM Single Input Module CHQ-SOM Single output module CHQ-WS2 Wall sounder YBO-BS Base sounder Sounder CHQ-WSB2 Wall sounder beacon VAD YBO-BSB2 Base sounder beacon VAD VAD / Sounder CHQ-CB Ceiling beacon VAD CHQ-WB Wall beacon VAD VAD CHQ-AB Loop Powered Strobe CHQ-ARI Loop Powered Remote Indicator Strobe YBN-R/3 Non Electronic Standard Base YBN-R/3 SCI Short circuit isolator base YBN-R/2NA Non Electronic Standard Base YBO-R/SCI Short circuit isolator base Bases YCA-RL/5H2 Addressable Master Base YCA-RL/3H2 Addressable Slave Base HCP-E (SCI) Manual call point HCP-W (SCI) Manual call point waterproof Manual Call points Note: These components have been validated as connectable for the function and performance of this equipment. The schedule will be extended to include Type 1 component compatibility upon validation and acquittal of an AS 7240.13 evaluation program

Schedule of relevant articles Supplementary information The following schedule is an extract of articles significant and/or related as evidence of conformity. Ident. type Report Report Reference Ident. XF2738/R1 TE275059 Issue 1 Title / description Evaluation for Conformity of the Taktis, TS series, fire control panels to the requirements of AS 7240.2-2004, AS 7240.4-2004 and AS 4428.3-2010 Technical evaluation of the Kentec Electronics Ltd Taktis 4-6 loop analogue addressable control and indicating equipment to the requirements of selected clauses from EN54-2:1997 +A1:2006, EN54-4:1997 +A1:2002, +A2:2006, EN 50130-4:1995, +A1:1998, +A2:2003 and EN 50130-4:2011 Date issued (or date validated) 12-Dec-2014 Page 5 of 5 Source CSIRO, Fire Systems, AU BRE Global Ltd, UK TE 275059-SW Issue 1 Software evaluation of the Kentec Electronics Ltd, Taktis range of analogue addressable Control & Indicating Equipment to the requirements of Clause 13 in EN 54-2. 14-Jan-2015 Part Man-1154-In Revision E01.00, OPIN-000004IN, Revision E01.00 Taktis Fire Control Panel - Installation Manual Taktis Operating Instructions Dec-2014 Incite Fire, AU