Residential Fire Sprinkler Inspection

Similar documents
SPRINKLER SYSTEM DRY WET

Annual Water-Based Fire Protection Systems Inspection

Annual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System

FIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT

ADDENDUM #1 ITB# Fire Protection Maintenance Services Responses to Clarification Questions 10/06/2015

New Construction Fire Inspection Process

Inspection Report Nursing Home Life Safety Code Section 4 - Annual Fire Alarm Testing and Maintenance. For

2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7

Oxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:

Skilled Healthcare Documentation Requirements Life Safety and Fire Protection

Service Requirements SEMI- ANNUAL ANNUALLY OTHER REF. REQUIREMENT

Quick Guide for Fire Sprinkler Inspection Requirements Key Deficiencies with NFPA References NFPA & NFPA 13/

Report of Inspection/Test

Sprinkler Inspection Certificate

Inspection of Fire Sprinkler Systems. NFPA 25, Inspection, Testing & Maintenance of Water Based Fire Protection Systems

USAutomatic Sprinkler Corporation

FIRE SPRINKLER SYSTEMS POLICY

MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

FIRE SPRINKLER SYSTEMS POLICY

NFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers,

Environmental Health & Safety

Global Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

MONTECITO FIRE PROTECTION DISTRICT

System Test Report CLEAN AGENT

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST STANDPIPE SYSTEMS

UBC Technical Guidelines Section Edition Fire Protection General Requirements Page 1 of 6

NFPA Edition Update

FIRE ALARM APPLICATION CITY OF MADISON HEIGHTS

Sprinkler Permit Applications

Final EC Inspection Report 03/2010

Fire Alarm and Life Safety System Inspection Certificate

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

Fire Sprinkler System Design and Installation Requirements

Global Property. QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Plan Review

AUTOMATIC FIRE SPRINKLER SYSTEMS

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

Inspector: PROPERTY INFORMATION Photo Smoke Detector Notification Control Panel Stand Alone Smoke Detector Dialer SUMMARY ONLY

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Fire Sprinkler Submittal Requirements and Acceptance Testing

SECTION SPRINKLER SYSTEMS

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

Sheetz Inc. Fire Protection Service Guidelines

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

SECTION WET-PIPE SPRINKLER SYSTEMS

False Sense of Security???

Burnsville Fire Department 100 Civic Center Pky, Burnsville, MN Fire Marshal: FAX:

Plan Review Check List Fire Alarm System

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 8 Annual Sprinkler System Inspection Revised

Fire Alarm Testing and Inspection Report

Revised March 2015 Fire Alarm Systems Verification. Schedule I(A) Services. *Manditory Site visit required*

Design & Construction Standards, Revised January

DISTRICT OF SECHELT. Inspection and Testing of Fire Protection Equipment Bylaw No. 397, 2002

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

EXHIBIT D ATTACHMENT G - UNIT PRICING DMS-14/15-039B - SIMPLEXGRINNELL, LP FIRE SPRINKLER SYSTEM INSPECTIONS YEARS 1-5

CITY OF PASADENA FIRE DEPARTMENT

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

Gas Station & C Store SECTION CWM Job No

Facilities Management

WALL ESCUTCHEON PIPE SEAL WITH APPROVED FIRE CAULKING (SEE SPECIFICATIONS) NOTE: 12" 12" 24"

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

Prefunctional Checklist

FIRE INSPECTION CHECKLIST

Checklist For Life Safety

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

A. This section includes design and performance information for fire protection and suppression systems.

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

Division 21: FIRE SUPRESSION WET-PIPE SPRINKLER PROTECTION SYSTEM. The Academy Sept Table of Contents 1 Division 21

FIRE SAFETY SYSTEMS MAINTENANCE INFORMATION

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

B. Section Identification for Fire Suppression Piping and Equipment.

Other EC and LS documents may be requested by surveyors, as needed, throughout the survey.

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

Established /10/2015. Doran Pruisner Dan Wood

2016 CDM Smith All Rights Reserved July 2016 SECTION FIRE PROTECTION - SPRINKLER AND STANDPIPE SYSTEMS

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

You are required to READ ALL PAGES. of this application

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

Building Life Safety Systems Testing

1 Exam Prep NFPA 14 Stand Pipe Systems Questions and Answers (Plumbing Contractors)

TECHNICAL DATA EASYPAC COMMERCIAL RISER MANIFOLD ASSEMBLIES 1-1/4-8 (DN32 - DN200)

Fire Permit Application

SECTION FIRE-SUPPRESSION STANDPIPES

DIVISION 21 - FIRE SUPPRESSION

Fire Alarm and Life Safety System Inspection Certificate

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

PLAN REVIEW CHECKLIST

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST

TECHNICAL DATA. 32a. September 18, /4-8 (DN32 - DN200)

ADDENDUM NO. 3 March 19, 2018

*** Inspection *** Please identify yourself as a Cintas representative when arriving onsite.

Transcription:

Residential Fire Sprinkler Inspection Hickory, NC 88.38.6363 Charleston, SC 843.78.08 Greensboro, NC 336.373.3973 Columbia, SC 803.99.00 Raleigh, NC 99.834.9644 Greenville, SC 864.458.7070 Charlotte, NC 704.37.3473 Atlanta, GA 770.978.7998 Tampa, FL 83.83.80 Date 7/7/6 Annual Quarterly PO Box 9489 Hickory, NC 8603 FED4-00006 EF0009 FPC-0004 CFC4900 # of wet systems: 7 Company: Oakland Mill Apartments # Antifreeze: Address: 0 Nelson Dr. # of BFPs Fire 8 Dom NC 809 Inspector: Adam Sims Phone: (704) -46 Contact: Cheryl Pate License #: 363 NERAL INFORMATION (GI) No N/A (SI) - CONTINUED No N/A. Are all dwelling units accessible for visual inspection? 0. Hangers & Seismic bracing OK?. Does the building appear to be fully sprinklered?. Antifreeze Systems tested? 3. Systems in service without modification since the last. Relief valves on system OK? inspection? 3. FDC swivels, gaskets, & caps in place and OK? 4. Spare head box with heads and wrench securely monitored? 4. FDC signs in place? 5. FDC equipped with ball drip? 5. Stock/storage a minimum of 8 below sprinkler head & ceiling tiles in place? 6. Sprinkler system main drain test completed? 6. Gauges condition good & less than 5 years old? ALARM INFORMATION (AI) No N/A Last calibration date: 03. Was the WMG or Electric bell tested & OK? 7. Wet system areas adequately heated?. Central Station flow alarm tested & OK? 8. Inspection of common areas only. 3. Central Station tamper tested & OK? VALVE INFORMATION (VI) No N/A 4. Alarm devices free from physical damage & all electrical connections secure?. Are all main control valves open? 5. Alarm trim, and valves OK & set properly?. Main control valves in good condition and identified? 6. Inspectors test connection(s) opened and flowed? 3. Are control valves secure? (Record pg. ) BFP INFORMATION (BI) No N/A 4. Are all control valves accessible & free from leaks?. Backflow devices pressure tested? 5. 5 year Internal check valve inspections due.. Backflow device forward flow tested? 6. Are all control valves provided with the proper controls? Sprinklers 7. All control valves operated through full range & returned to Make: normal position? Model: Globe gl490 8. Valves lubricated, as needed? Year: 03 SPRINKLER & PIPING INFORMATION (SI) No N/A Temp: 55/75. Are all sprinklers unobstructed? Finish: White. Sprinklers & escutcheon plates free of corrosion, tape, paint, & physical damage? QR/SR: Qr 3. Are all sprinklers less than 50 years old? K Factor: 4. Are all QR Sprinklers less than 0 years old? Thread: / 5. Are escutcheon plates OK? Esch: Sem rec 6. Riser in good condition & accessible? GB/Sldr: Gb 7. Hydraulic nameplate in place & OK? Antifreeze Systems(s) 8. System ID securely attached & legible? Location Number of Heads Temperature 9. Pipe in good condition, free of damage & obstructions, and leaks? Main Drain & Alarm Test System No: 3 4 5 6 7 8 9 System Size: Static Pressure (psi): Residual Pressure (psi): Static Pressure (psi): 30 45 Local Alarm OK (Y / N):, Locked, or Sealed No. of s Accessible (Y / N) Location (F=FDC, R=Riser) N F N F N F N F N F N F N F All Systems left in Service Inspections Tags In Place Inspection Results Discussed with Property Representative 7/7/6 Property Representative: Inspector s Signature: Date: 0

Hickory, North Carolina 8603 Hickory, NC 88.38.6363 Greensboro, NC 336.373.3973 Raleigh, NC 99.834.9644 Charlotte, NC 704.37.3473 Charleston, SC 843.78.08 FED4-00006 Columbia, SC 803.99.00 FPC-0004 Greenville, SC 864.458.7070 Atlanta, GA 770.978.7998 Tampa, FL 83.83.80 DATE: NFPA #7 FIRE ALARM INSPECTION/ENGINEERED SYSTEM INSPECTION REPORT EF0009 CFC4900 07/07/06 :00am EDT CUSTOMER: Oakland Mill Apartments ADDRESS: 0 Nelson Dr. CITY/STATE: PHONE: (704) -46 JOB #: 55374 NC ZIP: 809 Annual Semi Annual Other Monitoring Company ME: Oakland Mill Apartments PHONE: Building # Alarm Mfg. Model Manual Stations Smoke Detectors Heat Detectors Duct Detectors Waterflow Switches Switches Horn/Strobes Horns Only Strobes Only Door Holders Elevator Recall Battery Type Battery Date Panel Keys Pullstation Keys Clubhouse Vs 5 Na Na Na Na 6 V 8Amp 03 Bldg Vs v 8 amp 03 Bldg Vs v 8amp 03 Bldg 3 Vs v 8 amp 03 Notes or Deficiencies: 6- volt 8amp due for replacement X Date: Technician certifies alarm system was inspected. Deficiencies are noted. (If Applicable) 7-7-06 07/07/06 :00am EDT X Date: Customer has been informed of any deficiencies and accepts responsibility for verifying alarm signals to monitoring Co. (If Applicable)

Hickory, North Carolina 8603 Hickory, NC 88.38.6363 Greensboro, NC 336.373.3973 Raleigh, NC 99.834.9644 Charlotte, NC 704.37.3473 Charleston, SC 843.78.08 FED4-00006 Columbia, SC 803.99.00 FPC-0004 Greenville, SC 864.458.7070 Atlanta, GA 770.978.7998 Tampa, FL 83.83.80 DATE: NFPA #7 FIRE ALARM INSPECTION/ENGINEERED SYSTEM INSPECTION REPORT EF0009 CFC4900 07/07/06 :00am EDT CUSTOMER: Oakland Mill Apartments ADDRESS: 0 Nelson Dr. CITY/STATE: PHONE: (704) -46 JOB #: 55374 NC ZIP: 809 Annual Semi Annual Other Monitoring Company ME: Oakland Mill Apartments PHONE: Building # Alarm Mfg. Model Manual Stations Smoke Detectors Heat Detectors Duct Detectors Waterflow Switches Switches Horn/Strobes Horns Only Strobes Only Door Holders Elevator Recall Battery Type Battery Date Panel Keys Pullstation Keys Bldg 4 Vs v 8amp 03 Bldg 5 Vs v 8amp 03 Bldg 6 Vs v 8amp 03 Bldg7 Vs v 8amp 03 Notes or Deficiencies: X Date: Technician certifies alarm system was inspected. Deficiencies are noted. (If Applicable) 7-7-06 07/07/06 :00am EDT X Date: Customer has been informed of any deficiencies and accepts responsibility for verifying alarm signals to monitoring Co. (If Applicable)

PO Box 9489 Hickory, NC 8603 FED4-00006 EF0009 FPC-0004 CFC4900 Fire Sprinkler/Alarm Inspection Hickory, NC 88.38.6363 Charleston, SC 843.78.08 Greensboro, NC 336.373.3973 Columbia, SC 803.99.00 Raleigh, NC 99.834.9644 Greenville, SC 864.458.7070 Charlotte, NC 704.37.3473 Atlanta, GA 770.978.7998 Tampa, FL 83.83.80 Oakland Mill Apartments Company: 07/07/06 :00am Date Annual Quarterly Monthly No hydraulic nameplates installed at risers 7 total. Comments and Recommendations Roger Miller Inspector s Signature Customer Acknowledgment Print Name & Title

070 7th St. Ct. SE Phone: 88.38.6363 Fax: 88.38.6370 Address of Property: 0 Nelson Dr. Meter Model & Number: NC 809 Type of Service: DOM IRRIG. F.L. Combo (DOM/F.L.) Type of Assembly: RP DC PVB Size of Assembly: Model: 007mqt Serial Number: 04479 Location of Assembly: Bldg riser room Containment (at meter) or Isolation (at branch) Line Pressure: PSI: Check Valve # Relief Valve Check Valve # Pressure Vacuum Breaker.0.8 Shut Off # Held Tight Shut Off # Held Tight Assembly: PASSED FAILED NOTE: All repairs must be completed within (0) ten days. Kit: DIFF DUPL ELEC Manufacturer: 05844 TESTER: CERT. Adam NO: TIME/DATE: CALIBRATION 05-cm9-93 7-7-06 DATE: 5--06

070 7th St. Ct. SE Phone: 88.38.6363 Fax: 88.38.6370 Address of Property: 0 Nelson Dr. Meter Model & Number: NC 809 Type of Service: DOM IRRIG. F.L. Combo (DOM/F.L.) Type of Assembly: RP DC PVB Size of Assembly: Model: 007mqt Serial Number: 04307 Location of Assembly: Bldg riser room Containment (at meter) or Isolation (at branch) Line Pressure: PSI: Check Valve # Relief Valve Check Valve # Pressure Vacuum Breaker.8.0 Shut Off # Held Tight Shut Off # Held Tight Assembly: PASSED FAILED NOTE: All repairs must be completed within (0) ten days. Kit: DIFF DUPL ELEC Manufacturer: 05844 TESTER: CERT. Adam Sims NO: TIME/DATE: CALIBRATION 05-cm9-93 7-7-06 DATE: 5--06

070 7th St. Ct. SE Phone: 88.38.6363 Fax: 88.38.6370 Address of Property: 0 Nelson Dr. Meter Model & Number: NC 809 Type of Service: DOM IRRIG. F.L. Combo (DOM/F.L.) Type of Assembly: RP DC PVB Size of Assembly: Model: Serial Number: 04305 Location of Assembly: Bldg 3 riser room Containment (at meter) or Isolation (at branch) Line Pressure: PSI: Check Valve # Relief Valve Check Valve # Pressure Vacuum Breaker.0.0 Shut Off # Held Tight Shut Off # Held Tight Assembly: PASSED FAILED NOTE: All repairs must be completed within (0) ten days. Kit: DIFF DUPL ELEC Manufacturer: 05844 TESTER: CERT. Adam Sims NO: TIME/DATE: CALIBRATION 05-cm9-93 7-7-06 DATE: 5--06

070 7th St. Ct. SE Phone: 88.38.6363 Fax: 88.38.6370 Address of Property: 0 Nelson Dr. Meter Model & Number: NC 809 Type of Service: DOM IRRIG. F.L. Combo (DOM/F.L.) Type of Assembly: RP DC PVB Size of Assembly: 8" Model: 909 Serial Number: 673 Location of Assembly: In hotbox beside bldg 0 Containment (at meter) or Isolation (at branch) Line Pressure: 45 PSI: Check Valve # Relief Valve Check Valve # Pressure Vacuum Breaker.4 5.0 7.4.6 Shut Off # Held Tight Shut Off # Held Tight Assembly: PASSED FAILED NOTE: All repairs must be completed within (0) ten days. Kit: DIFF DUPL ELEC Manufacturer: 05844 TESTER: CERT. Adam Sims NO: TIME/DATE: CALIBRATION 05-cm9-93 7-7-06 DATE: 5--06

070 7th St. Ct. SE Phone: 88.38.6363 Fax: 88.38.6370 Address of Property: 0 Nelson Dr. Meter Model & Number: NC 809 Type of Service: DOM IRRIG. F.L. Combo (DOM/F.L.) Type of Assembly: RP DC PVB Size of Assembly: Manufacturer: Wilkins Model: 375 Serial Number: A9754 Location of Assembly: In hotbox left of bldg 4 Containment (at meter) or Isolation (at branch) Line Pressure: 45 PSI: Check Valve # Relief Valve Check Valve # Pressure Vacuum Breaker 3. 6.4 9.6.6 Shut Off # Held Tight Shut Off # Held Tight Assembly: PASSED FAILED NOTE: All repairs must be completed within (0) ten days. Kit: DIFF DUPL ELEC Manufacturer: 05844 TESTER: CERT. Adam Sims NO: TIME/DATE: CALIBRATION 05-cm9-93 7-7-06 DATE: 5--06

070 7th St. Ct. SE Phone: 88.38.6363 Fax: 88.38.6370 Address of Property: 0 Nelson Dr. Meter Model & Number: NC 809 Type of Service: DOM IRRIG. F.L. Combo (DOM/F.L.) Type of Assembly: RP DC PVB Size of Assembly: Model: 007mqt Serial Number: 04460 Location of Assembly: Bldg 4 riser room Containment (at meter) or Isolation (at branch) Line Pressure: PSI: Check Valve # Relief Valve Check Valve # Pressure Vacuum Breaker.0.0 Shut Off # Held Tight Shut Off # Held Tight Assembly: PASSED FAILED NOTE: All repairs must be completed within (0) ten days. Kit: DIFF DUPL ELEC Manufacturer: 05844 TESTER: CERT. Adam Sims NO: TIME/DATE: CALIBRATION 05-cm9-93 7-7-06 DATE: 5--06

070 7th St. Ct. SE Phone: 88.38.6363 Fax: 88.38.6370 Address of Property: 0 Nelson Dr. Meter Model & Number: Na NC 809 Type of Service: DOM IRRIG. F.L. Combo (DOM/F.L.) Type of Assembly: RP DC PVB Size of Assembly: Model: 007mqt Serial Number: 04306 Location of Assembly: Bldg 5 riser room Containment (at meter) or Isolation (at branch) Line Pressure: PSI: Check Valve # Relief Valve Check Valve # Pressure Vacuum Breaker.8.8 Shut Off # Held Tight Shut Off # Held Tight Assembly: PASSED FAILED NOTE: All repairs must be completed within (0) ten days. Kit: DIFF DUPL ELEC Manufacturer: 05844 TESTER: CERT. Adam Sims NO: TIME/DATE: CALIBRATION 05-cm9-93 7-7-06 DATE: 5--06