ATEX. Wolf Safety Lamp Company. The widest range of portable ATEX lighting approved for use in explosive atmospheres

Similar documents
distributed by Sole Agent in Great China Universky (Jiangsu) Technologies, Inc. Phone: Fax:

ATEX. Wolf Safety Lamp Company. Includes NEW LinkEx LED. The widest range of portable ATEX lighting approved for use in explosive atmospheres

Wolf Safety Lamp Company HAZARDOUSAREA PORTABLE & TEMPORARY LIGHTING POWER DISTRIBUTION

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications

INTRINSICALLY SAFE LIGHTING RANGE

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

EU Directive 94/9/EC Equipment and Protective Systems intended for use in potentially explosive atmospheres (ATEX)

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

NexLED. Ex e LED BULKHEAD. Features. Standard Specification. International Approvals. NexLED with Exit Sign kit

High Quality LED Lighting!

Ex LED light fittings

LED NEW FB-SERIES LED NEW-SF FIXTURE LED NEW-SD FLOODLIGHT LED NEW-SD STREET. LED Explosion-proof Platform Light. LED Tri-proof Light

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

Compact, robust crimping tool. suitable for a variety of noninsulated. terminals. Also features a cable cutter and spring return.

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

LIFE SAFETY & RESCUE SOLUTIONS. Torches and lighting solutions COPY ONLY

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

of Conformity IECEx Gert f cate Test Safe

Telephony & Communication

HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments.

EX-SIGNAL- AND ESCAPE SIGN LUMINAIRS

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

Products for the area

FLASHLIGHT ANSI STANDARDS

OPTIBAR DP 7060 Supplementary Instructions

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

XLFE-4/1. Borosilicate glass globe

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

D O M E S T I C LED. Lighting C O M M E R C I A L

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Distributed by ECO LIGHT PRODUCT OVERVIEW. Hazardous Area Luminaires

Integrated Solutions Low Voltage Systems

INSTRUCTION MANUAL (ATEX / IECEx)

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

Dräger X-am 7000 Multi-Gas Detection

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

ATEX. Tough controls for tough environments. ia.danfoss.com. Brochure Controls. Danfoss controls - designed and approved for hazardous areas

PERSONAL COMBUSTIBLE GAS DETECTOR

WHO WE ARE AND WHAT WE DO

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Light special. Product special

Industrial & Hazardous Area Electrical Equipment

Hazardous Area Portable Fan Heater The Bulldog

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

G-TECTA TM. Portable Gas Detection Instruments

Celebrating YEARS Manufacturers of Visual & Audible Signalling Devices. NEW Exd

Intrinsically Safe Solutions

Hazardous Area Portable Fan Heater The Bulldog

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

PRODUCT DATA SHEET ilh8

Vehicle Safety & Warning. Product Catalogue (0)

FIRE AND SAFETY. Manual Call Points p15-1 Magnetic Door Holders p15-3 Detection Cables p15-4 Portable Signals p15-7 Solar Powered Signals p

Industrial Signalling

Illumination unit For sight glass level indicator Model LGI

High bay LED lighting fixture

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

ILED Aquarius CIRCLE-H Mk 2 Helideck Lighting System

DB5 Intrinsically Safe Sounder Type DB-5

BC9700 series High Power LED Explosion Proof Light

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

LED Explosion proof Torch Light. Ex Marking:Ex ibⅡc T4 Gb Ex ib ⅢC T130 Db IP 68. KHJ-LED Explosion Proof Lighting

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

EXPLOSION PROTECTION SPECIALISTS. Experts in Equipment for Explosive Atmospheres TOTAL SUPPLY MEASURE DETECT METER POWER LIGHT HEAT

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Motorola Professional Series Enhanced ATEX Portable Radios. October 2007

Basic Ex products / Zone 1, 21

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

Annubar Flowmeter Series

Approved by: Document no.: EGT

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

ATEX, NOMENCLATURE AND CODING

Dräger X-am 5000 Multi-Gas Detection

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

LED Protected Catalogue

ATEX. IECEx. culs GOST-R. VdS

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Dräger Polytron 8000 Stationary gas detector (EC)

Druck DPI 705/DPI 705 IS Series

IECEx Certificate of Conformity

OPTIBAR P 1010/2010 C Supplementary instructions

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

DTS Light fittings for explosive atmospheres

2018 PRODUCT CATALOGUE

INSTRUCTION MANUAL (ATEX / IECEx)

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

Hazardous Area Portable Fan Heater The Bulldog

We measure it. testo 316-Ex CH 4 testo 316-1

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Beamex Calibration White Paper. Calibration in hazardous areas

Dräger Polytron 5100 EC Detection of toxic gases and vapors

IT S WHAT S INSIDE THAT

Specification Sheet. Certificates. Features. Application. Anti-Explosive Lamp

Phoenix Flameproof. Pan & Tilt heads and Camera Housings for potentially explosive environments.

LED Lights Catalogue 2012

Transcription:

Includes NEW ATEX Fluorescent Leadlamp Range Wolf Safety Lamp Company The widest range of portable ATEX lighting approved for use in explosive atmospheres Wolf Safety have Ex lighting products for all purposes, the correct apparatus for every hazardous area application. Wolf Safety Lamps have proven quality and reliability in their wide use in many industry sectors including firefighting, oil, gas, petrochemicals, aviation, marine, offshore, pharmaceuticals and water treatment. ATEX WOLF SAFETY LAMP COMPANY Saxon Road Works, Sheffield, S8 OYA Tel: +44 114 255 1051 Fax: +44 114 255 7988 E-mail: info@wolf-safety.co.uk Website: www.wolf-safety.co.uk

WOLF MINI & MICRO TORCHES Primary Cell Mini Safety Torches Ultra small size ATEX Approved for explosive gas and dust atmospheres T4 and T5 temperature class versions Zone 0 certified LE models Simple, robust design with integral clip Single handed switching Ingress protection to IP67 as and ust Approval roup I Mining Approval M-10 M-20 M-40 M-60 I M1/II 1 Ex ia I/IIC T5 t A20 IP67 T80 o C Baseefa06ATEX0084 Zone Zone Zone Zone 0, 1 & 2 1 & 2 0, 1 & 2 0, 1 & 2 Zone Zone Zone Zone 20, 21, 22 21, & 22 20, 21, 22 20, 21, 22 25g I M1/II 2 Ex ib I/IIC T4 t A20 IP67 T80 o C I M1/II 1 Ex ia I/IIC T4 t A20 IP67 T80 o C 60g 22 x 70mm 22 x 146mm 4 x LR44 2 x LR03 3 x LR1 (N) (AAA) I M1/II 1 Ex ia I/IIC T4 t A20 IP67 T80 o C 1x5mm LE 1.05W 3x5mm LE 1W LE Xenon 2hrs 2.3hrs 10hrs 10hrs IP67 M-10 8 lux (13 ) @ 2.5m M-20 100 lux (6 ) @ 2.5m M-40 15 lux (18 ) @ 2.5m M-60 45 lux (8 ) @ 2.5m WOLF ATEX SAFETY TORCH Primary Cell Safety Torch ATEX Approved for explosive gas and dust atmospheres T6 and T4 models Simple, robust design Optimum Halogen light output High energy, long life alkaline cell approval Low battery power indicator option TS-26/TR-26 TS-24/TR-24 TS-24+/TR-24+ II 2 EEx e ib II 2 EEx e ib IIC T4 IP67 T95ºC IIC T6 IP67 T65ºC (Tamb=40/55ºC) BAS02ATEX2220X 0.350kg/0.390kg 0.450kg/0.490kg 60 x 60 x 200/60 x 80 x 195mm 2 x R20 () 2 x LR20 () 1.2W 1.7W Xenon 2.0W Halogen 5hrs 12hrs 10hrs IP67 TS-26/TR-26 180 lux (5 ) @ 5m TS-24/TR-24 230 lux (5 ) @ 5m TS-24+/TR-24+ 280 lux (5 ) @ 5m

WOLF ATEX LE TORCH High-tech LE Safety Torch ATEX Approved for explosive as and ust atmospheres LE light source fitted for life, no bulb replacement required High output focussed spot beam with flood of lower level fringe light Over 7.5 hours high power output from 4 x AA alkaline primary cells Compact and lightweight torch design Low battery indicator fitted on TR-40+ model Zone 0 version available All models with roup I Mining Approval TR-40 & TR-40+ TR-45 II Ex ib IIC T4/T3 ta21 IP67 T85 C Baseefa07ATEX0091 Zone 0, 1 & 2 0.350Kg 60 x 80 x 195mm 4 x LR6 (AA) 1W LE 72hrs IP67 II 1 Ex ia IIC T4/T3 ta21 IP67 T85 C Baseefa07ATEX0091 TR-45 TR-40/TR-40+ Wolf ATEX LE Torch 1.4W LE beam (approx 6 ) Peak luminous intensity at 5m, 230lux 0035 WOLF RECHAREABLE TORCH Rechargeable Safety Torch ATEX Approved for explosive as and ust atmospheres Outstanding light output from LE or Halogen bulb versions Compact and lightweight ergonomic torch design Up to 6.5 hour duration using latest battery technology Battery state-of-charge indicator Mains and vehicle quick charge option Zone 0 version available R-30 R-50 II 2 T85ºC Ex eib II 2 T85ºC Ex ib IIC T4 t A21 IP67 T85ºC IIC T4 t A21 IP67 T85ºC Baseefa05ATEX0068 Baseefa05ATEX0069 0.340kg 0.375kg 60 x 80 x 195mm 7.4V 2.2Ah Li-Ion 4W Halogen 3W LE 3.5/6.5hrs IP67 R-30L/R-50L 12-24Vdc R-30H/R-50H 100-254Vac 3.0 hrs R-30 340 lux (6 ) @ 5m R-50 360 lux (6 ) @ 5m

WOLF ZONE 0 HEATORCH Primary Cell Safety Headtorch Explosive Atmosphere, Category 1 certified for Zones 0,1 & 2 Everlasting light source Push button switchable three, five or seven LEs Long 30 hour duration Robust anti-static thermoplastic enclosure Totally hands free for head or hardhat use HT-200 II 1 EEx ia IIC T4/T3 Baseefa04ATEX0398 Zone 0, 1 & 2 0.215kg 110 x 95 x 85mm 3 x LR6 (AA) 7 x 5mm LE 30 hrs IP54 114 lux (28 ) @ 1m, 19 lux (28 ) @ 2.5m WOLF UO ATEX LE HEALAMP Rechargeable Safety Headtorch Completely hands free for head or hardhat use Pivoting head unit for accurate beam positioning Selectable 1W LE or 5mm LE Cluster Explosive gas, vapour and mist certified for zones 1 & 2 Rechargeable, supplied with quick battery charger Robust, ergonomic design HT-01 II 2 EEx ia IIC T3 Ex ia 21 T200 o C INERIS02ATEX0056 0.325kg 50 x 50 x 60mm 4.8V 2.7Ah Ni-MH 1W LE 5 x 5mm LE 10hrs 30hrs IP68 100-240Vac 3.5hrs 1W variable beam 31lux (4.5º) @ 5m (spot) 14lux (13.5º) @ 5m (wide) 0.5w LE BEAM 6.5lux (27º) @ 2.5m 0035

WOLFLITE HANLAMP H-4CA Primary Cell Safety Handlamp Category 2 certified for Zones 1 & 2 explosive atmospheres ust ignition protected for Zones 21 and 22 Alkaline primary cell approval giving 20 hour duration Increased light output from halogen bulb Robust anti-static thermoplastic lamp enclosure Ingress protection to IP66 H-4CA II 2 EEx e ib IIC T4 IP67 T135 C BAS00ATEX2203 1.45kg 130 x 140 x 185mm 4 x LR20 () 2.4W Halogen 20hrs IP66 960lux (3.5 ) @ 5m WOLFLITE HANLAMP H-251A Rechargeable Safety Handlamp Explosive gas, vapour and mist certified for Zones 1 & 2 ust ignition protected for Zones 21 and 22 Electronic current limited battery with deep discharge protection Halogen or LE light source with LE bulb replacement option Robust anti-static thermoplastic lamp enclosure For use with Wolf mains and vehicle chargers H-251A II 2 EEx e ib IIC T4 IP67 T135 C BAS00ATEX2176 1.75kg 130 x 140 x 185mm 4.0V 5.0Ah Pb 2.8W Halogen 1W LE 7hrs 24 Hrs IP66 C-251LV 12-32Vdc C-251HV 230/110Vac 10hrs 700lux (4 ) @ 5m

WOLF ATEX TURBOLITE High-power compressed air Safety Lamp For use in Zones 1 and 2 hazardous areas Aluminium super-lightweight construction 250 watt Halogen light output Safe compressed air power source ust ignition protected for Zones 21 and 22 using remote exhaust roup 1 Mining approval with alternative brass construction A-TL44A A-TL45A II 2 II T4 (Tamb = 55 C) T135 C SIRA02ATEX5099X 5.5kg 7.1kg 170 x 180 x 280mm 220 x 180 x 240mm 0.75m 3 /min @ 5-8bar 250W Halogen IP40 IP68 A-TL45A A-TL44A A-TL44A/B 70lux @ 2.5m A-TL45A/B 2000lux (10 ) @ 5m A-TL45A/B 950lux (25 ) @ 5m WOLF ATEX WORKLITE Rechargeable high output LE floodlight ATEX Approved for Zone 1 explosive as and ust atmospheres High power white LE beam with flood of lower level fringe light LE light source fitted for life, no bulb replacement required Long duration, up to 12 hours full power, 24 hours half power Locking pivot head Toughened glass lens with optional disposable lens guard WL-85 WL-70 WL-80 II 2 Ex e ib mb IIC Ex t A21 IP65 T135 C Sira07ATEX3027 23kg 16kg 16.6kg 550 x 240 x 230mm 12/24hrs 470 x 240 x 230 12/6hrs 12 x 3W LE 6 x 3W LE 12 x 3W LE IP65 100 254VAC WL-85 12hrs 8hrs WL-70 WL-70 18W LE beam (approx 30 ) Peak luminous intensity at 5m 120lux WL-85 & WL-80 36W LE beam (approx 30 ) Peak luminous intensity at 5m 210lux

WOLF FLUORESCENT LEALAMP Mains Powered Portable Fluorescent Luminaire ATEX & IECEx Approved for Zone 1 explosive as and ust atmospheres Fitted with Plugs and Sockets to Link in Series Uses Standard Compact Fluorescent lamps for ease of maintenance Twin or Quad lamp configuration Compact and robust design Integrated Unistrut compatible mounting points LL-500 II 2 Ex emb IIC T3/T4 Ex t A21 T100ºC IP66/67/68 Zones 1 & 2 Zones 21 & 22 4Kg 190ø x 580 24/42/110/230V AC/C 2 x 36W 10,000 hrs IP66/67/68 The specifications above are for 2 x 36W version, 18W & 55W versions are available. LL-500 2x 36W CFL (approx 180 ) 4x 36W CFL (approx 360 ) Peak luminous intensity at 2.5m 138 lux Peak luminous intensity at 5m 36 lux WOLF TANK LIHTIN KIT Safe Low Voltage Lighting ATEX Approved for Zone 1 explosive as and ust atmospheres Safe Extra Low Voltage Robust durable construction Choice of Stainless Steel or RP Transformer Powers up to 4 Lamps Twin or Quad lamp configuration Applications Include: Tank Cleaning Utility Markets Vessel Entry Tunnel maintenance Aircraft maintenance Sewers & rains Tank Lighting Kit Configuration Matrix Wolf Tank Lighting Kit Code LL-115 LL-215 LL-125 LL-225 LL-116 LL-216 LL-126 LL-226 Certification Code II 2 Ex emb II T3/T4 Ex t A21 IP66/67/68 T100 C Lamp Models * 4 x LL-524/20 3 x LL-524/20 & 1 x LL-544/20 Lamp Output 4 x 72W (288W) 3 x 72W & 1 x 144W (360W) Transformer LL-114 LL-214 LL-124 LL-224 LL-114 LL-214 LL-124 LL-224 Transformer Type RP Stainless Steel RP Stainless Steel Transformer Voltage 110V 230V 110V 230V 110V 230V 110V 230V * Please refer to the Fluorescent Leadlamp sales leaflet for individual lamp specification

WOLF FLAMEPROOF LEALAMP CERTIFICATION COE II 2 EEX E IIC T3/T4 WOLF EX LS LEALAMP CERTIFICATION COE II 2 EEX E IIA T3 Powerful Safety Halogen Spotlight Handheld Safety Inspection Lamp Complies with ATEX irective 94/9/EC High output Halogen light, up to 70 watts Lightweight alloy construction for single handed portability, as group IIC T3/T4 certified esigned for quick and easy relamping and maintenance 12, 24 or 42 Volts models available Ideal for cleaning, grit blasting and painting operations 0158 ATEX approval for use in zones 1 & 2 explosive atmospheres Uses standard 60 watt LS rough service ES lamps Robust construction with rubber handle and impact ring Toughened glass cover with steel cage Cast iron locking ring Convenient integral hanging hook 0158 WOLF LITETRACKER & BIKELITE CERTIFICATION COE II 1 EEX E IB IIC T4 WOLF HAZAR LAMP CERTIFICATION COE II 1 EEX IA IIC T4 Primary Cell Safety Flashing Indicator Primary Cell Safety Hazard Lamp Multi-functional, selectable torch-flash-strobe output Certified intrinsically safe ia for use in Zones 0, 1 or 2 Approved for use in Zone 0 explosive atmospheres Flashing or static light output selectable High intensity LE light source High strength polycarbonate case Small and lightweight Enhanced user conspicuity in dark conditions ATEX Continuous operation in flashing mode of up to two months aylight cut-out mode selectable from internally mounted switch Ultra-bright LE light source Ideal for highlighting obstacles and dangers in the hazardous area SL010 issue 5 MM/???/11.08/?K