SUPPLEMENTAL INFORMATION SHEET FOR QPL SUPPLEMENTAL INFORMATION SHEET FOR QUALIFIED PRODUCTS LIST

Similar documents
SUPPLEMENTAL INFORMATION SHEET FOR QPL SUPPLEMENTAL INFORMATION SHEET FOR QUALIFIED PRODUCTS LIST

SUPPLEMENTAL INFORMATION SHEET FOR QPL SUPPLEMENTAL INFORMATION SHEET FOR QUALIFIED PRODUCTS LIST

SUPPLEMENTAL INFORMATION SHEET FOR QPL SUPPLEMENTAL INFORMATION SHEET FOR QUALIFIED PRODUCTS LIST

SUPPLEMENTAL INFORMATION SHEET FOR QPL SUPPLEMENTAL INFORMATION SHEET FOR QUALIFIED PRODUCTS LIST

SUPPLEMENTAL INFORMATION SHEET FOR QUALIFIED PRODUCTS LIST PRODUCTS QUALIFIED UNDER SAE AEROSPACE STANDARD AS7928

The activity responsible for this QPL is the Defense Supply Center Columbus (DSCC-VQ), Columbus, OH

THE ACTIVITY RESPONSIBLE FOR THIS QPL IS THE DEFENSE SUPPLY CENTER COLUMBUS (DSCC-VQ), COLUMBUS, OH TEST OR QUALIFICATION REFERENCE

THE ACTIVITY RESPONSIBLE FOR THIS QPL IS THE DEFENSE SUPPLY CENTER COLUMBUS (DSCC-VQ), COLUMBUS, OH TEST OR QUALIFICATION REFERENCE

THE ACTIVITY RESPONSIBLE FOR THIS QPL IS THE DEFENSE SUPPLY CENTER COLUMBUS (DSCC-VQ), COLUMBUS, OH TEST OR QUALIFICATION REFERENCE

SEMIANNUALLY 29 November 1996 SUPERSEDING QPL-l May 1996 QUALIFIED PRODUCTS LIST PRODUCTS QUALIFIED UNDER MILITARY SPECIFICATION

QUALIFICATIONS VALIDATED QML ANNUALLY 12 February 1998 SUPERSEDING QML November 1997 QUALIFIED MANUFACTURERS LIST

SEMIANNUALLY 29 November 1996 SUPERSEDING QPL September 1996 QUALIFIED PRODUCTS LIST PRODUCTS QUALIFIED UNDER MILITARY SPECIFICATION

The activity responsible for this QPL is the Defense Supply Center Columbus (DSCC-VQ), Columbus, OH TEST OR QUALIFICATION REFERENCE -1-

NEMA Standards Publication WC High-Temperature and Electronic Insulated Wire, Impulse Dielectric Testing

S200 SHIELD TERMINATORS

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

ANNUALLY 25 July 2002 SUPERSEDING QML March 2002 QUALIFIED MANUFACTURERS LIST PRODUCTS QUALIFIED UNDER PERFORMANCE SPECIFICATION

DETAIL SPECIFICATION SHEET

DLA Land and Maritime - VQ Supplemental Information Sheet for Electronic QPL-81381

Insulated High Temperature Hook-Up Wire; Types ET (250 Volts), E (600 Volts), and EE (1000 Volts)

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

SolderSleeve Insulated Electrical Termination Devices

DETAIL SPECIFICATION. EXTINGUISHER, FIRE, HALOCARBON (HFC-236fa), PORTABLE, WITH MOUNTING BRACKET, FOR AVIATION USE

ANNUALLY 25 November 1998 SUPERSEDING QML February 1998 QUALIFIED MANUFACTURERS LIST DEPARTMENT OF DEFENSE PERFORMANCE SPECIFICATION

38-SDMS-03 SPECIFICATIONS FOR LV DIGITAL PANEL METERS

SolderSleeve Shield Terminators

THE ACTIVITY RESPONSIBLE FOR THIS QPL IS THE DEFENSE SUPPLY CENTER COLUMBUS (DSCC-VQ), COLUMBUS, OH , telephone (614)

FEB. 17 Rev. A1

DETAIL SPECIFICATION

Procedure. for. Installation. of the P/N & P/N Voice Alert Systems. Procedure IP 1 Rev. 1. Date

AUTOMOTIVE MINIATURE WIRE (AMW)

Product Specification CAT 6 UNSHIELDED PATCH CORDS

/Oct/2014 Rev E

Wire and Cable The Industry Standard for Rugged, Reliable Performance

THE ACTIVITY RESPONSIBLE FOR THIS QPL IS THE DEFENSE SUPPLY CENTER COLUMBUS (DSCC-VQ), COLUMBUS, OH , telephone (614)

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

Industrial Strength Leak Detection

THE ACTIVITY RESPONSIBLE FOR THIS QPL IS THE DEFENSE SUPPLY CENTER COLUMBUS (DSCC-VQ), COLUMBUS, OH , telephone (614)

Mar11 Rev C

DETAIL SPECIFICATION

Cat 6 Unshielded Patch cords

METRIC. Wire and Cable. Wire and Cable. Table of Contents. Dimensions in this section are millimeters over inches

9Wire and Cable. Table of Contents

Cat 6 Shielded Patch cords

Plug shell and receptacle, single cavity, floating, EN Application of modular rectangular modules and shells per EN4165

Tether and Umbilical Cables for Remotely Operated Vehicles

American National Standard


Installation Procedure and Inspection Criteria for SolderSleeve Coaxial Cable Terminators on Coaxial Cables Rated For At Least 125 C.

SECTION ISOLATED POWER SYSTEMS

TABLE OF CONTENTS. Section Title Page 1.0 SUMMARY TEST SPECIMEN Materials and Construction TEST PROGRAM 4

THE ACTIVITY RESPONSIBLE FOR THIS QPL IS THE DEFENSE SUPPLY CENTER COLUMBUS (DSCC-VQ), COLUMBUS, OH , telephone (614)

Your Pick... One Solution

COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE

RF one-step BNC/TNC connectors for coaxial cable termination

Jan05 Rev A EC

PAIRED UNJACKETED. Insulation Nominal Anixter. Paired Conductors Thickness O.D. Number AWG Strand No. IN IN

DESCRIPTION. 42 mm. 125 mm

Jun08 Rev C

Capital Projects Group Fire Extinguishers Specification

BAT LTE SKU: IPD-BAT-LTE

MIL-STD-1407B 17 December 1985 SUPERSEDING MIL-STD-1407A 16 July 1975 MILITARY STANDARD HEATERS, VEHICULAR COMPARTMENT; HEATERS, COOLANT, ENGINE;

/Oct/2014 Rev B

8Electrical Interconnect Products

American National Standard for Electrical Lamp Bases Specifications for Bases (Caps) for Electric Lamps

SEMIANNUALLY 22 May 2001 SUPERSEDING QPL July 1997 QUALIFIED PRODUCTS LIST PRODUCTS QUALIFIED UNDER PERFORMANCE SPECIFICATION MIL-PRF-39005

ISO 9152 INTERNATIONAL STANDARD. Aerospace Bolts, with MJ threads, in titanium alloys, strength class MPa Procurement specification

CSI Master Format 2012 Guide Specification for: Hot Water Temperature Maintenance (HWAT) Systems

Introducing SlimSeal SSL Connector

Sensor and transducer cables

VERIFICATION OF FIRE ALARM SYSTEMS

Florida Senate SB 982 By Senator Bennett

Raychem Overvoltage Devices. ROV14, ROV14H, ROV14E 14mm Series Metal Oxide Varistors

THE ACTIVITY RESPONSIBLE FOR THIS QPL IS THE DEFENSE SUPPLY CENTER COLUMBUS (DSCC-VQ), COLUMBUS, OH , telephone (614)

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

AS/NZS :2003 Luminaires - Part 1: General requirements and tests

Two Circuit Heavy Duty Burner Connector

NEMA Standards Publication WC Standard for Controlled Impedance in Internal Electrical Cable

C-Bus Four Channel General Input Unit Installation Instructions

Completed Projects / Projets terminés

Ultrasonic Clamp-On Flow Meter Testing

Title: Fire Sprinkler System Permit Requirements

Mar11 Rev B

FIRE ALARM PRE-INSPECTION CHECKLIST 1. REFER TO CHAPTER 10 OF CURRENT STATE ADOPTED NFPA 72, FOR INSPECTION, TESTING AND MAINTENANCE PROCEDURES.

MILITARY/AEROSPACE MARKETS INNOVATIVE SOLUTIONS GUIDE

Raychem Overvoltage Devices. ROV05, ROV05H 5mm Series Metal Oxide Varistors

Department of General Services Real Estate Services Division Professional Services Branch Additional Detailed Instructions (ADI)

FIRE & LIFE SAFTEY STANDARD

Certificate of Compliance

IFGC-2012 AMENDED IFGC-2015 IFGC-2018 CHAPTER 1 SCOPE AND

SVENSK STANDARD SS-EN :2005

AS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection

Iowa Electrical Examining Board Division of the State Fire Marshal s Office

SECTION ELECTRICAL GENERAL PROVISIONS

NEMA Standards Publication WC Standard for Controlled Impedance Shielded Twisted Pairs in Internal Electrical Cable

Table of Contents. Section Title Page 1.0 SUMMARY TEST SPECIMEN Materials and Construction 3.0 TEST PROGRAM 2

EMS510 Electrical Wiring Guide Volume 2, Rev 1.4

FIRE ALARM SYSTEM INSPECTION

CONTENTS AUTOMATIC TRANSFER SWITCHES

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

Transcription:

SUPPLEMENTAL INFORMATION SHEET FOR QPL 85485 QUALIFICATIONS HAVE BEEN VALIDATED (Frequency: 3 Years) BY VERIFICATION TESTING -6 16 Sept 2014 SUPPLEMENTAL INFORMATION SHEET FOR QUALIFIED PRODUCTS LIST OF PRODUCTS QUALIFIED UNDER SAE AEROSPACE STANDARD MIL-C-85485 CABLE ELECTRIC, FILTER LINE, RADIO FREQUENCY ABSORPTIVE This list has been prepared for use by or for the Government in the acquisition of products covered by the subject non-government standard and such listing of a product is not intended to and does not connote endorsement of the product by the Department of Defense. All products listed herein have been qualified under the requirements for the product as specified in the latest adopted issue of the applicable non-government standard. This list is subject to change without notice; revision or amendment of this list will be issued as necessary. The listing of a product does not release the manufacturer from compliance with the non-government standard requirements. The activity responsible for this qualified products list and for qualification approval is the Naval Air Systems Command, AIR-4.4.5.3, 48298 Shaw Rd., Building 1461, Patuxent River, Maryland 20670-1900. Manufacturer s full name, cage number, office and plant addresses are listed at the end of this QPL. THIS DOCUMENT IS AN OFFICIAL SUPPLEMENTAL INFORMATION SHEET OF THE PRODUCTS TRANSFORMED TO AN EQUIVALENT QUALIFICATION DATA SET (QDS). USERS OF THIS DOCUMENT MUST VISIT THE QUALIFIED PRODUCTS DATABASE (QPD) TO VERIFY QUALIFICATION INFORMATION. PLEASE VISIT HTTP://ASSIST.DAPS.DLA.MIL/ONLINE/START/ TO ACCESS INFORMATION. YOU MUST HAVE A USER PASSWORD TO ENTER SITE. ONCE LOGGED IN CHOOSE QPD FROM THE SIDE MENU. YOU CAN SEARCH BY QPL NUMBER, DOCUMENT NUMBER, GOVERNING SPEC, TITLE, FSC, GOVERNMENT, NON-GOVERNMENT (NGS), MANUFACTURER, OR SOURCE NAME. DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. AMSC N/A FSC 6145 1

NAME, ADDRESS AND PLANT CAGE NUMBER NAME, ADDRESS AND PLANT CAGE NUMBER For the sake of brevity, part number designations are displayed and interpreted as shown. GOVERNMENT MANUFACTURER S M85485/X- 22 -* XXX421-22 -* thru thru 10 10 * The asterisk in the part number will be replaced by color code designation. Matrices generate the following fictitious part numbers: (gauge size intervals of 2) M85485/X-22-* M85485/X-20-* M85485/X-18-* M85485/X-16-* M85485/X-14-* M85485/X-12-* M85485/X-10-* XXX421-22-* XXX421-20-* XXX421-18-* XXX421-16-* XXX421-14-* XXX421-12-* XXX421-10-* 2

MIL-C-85485/5, CABLE, ELECTRIC, FILTER LINE, COMPONENT WIRE, TIN-COATED COPPER CONDUCTOR, RADIO FREQUENCY ABSORPTIVE, 150 C, 600-VOLT. M85485/5-22 -* 55FA0411-22 -* Tyco Electronics-Raychem thru thru 10 10 05120201.AJ/01-23-13 M85485/5-22-7L -20-7L -18-7L -16-7L -14-7L -12-7L -10-7L H90052240702 H90052040702 H90051840702 H90051640702 H90051440702 H90051260702 H90051060702 Judd Wire Inc. 05113501.AD/04-30-2014 MIL-C-85485/6, CABLE, ELECTRIC, FILTER LINE, COMPONENT WIRE SILVER-COATED HIGH STRENGTH COPPER ALLOY CONDUCTOR, RADIO FREQUENCY ABSORPTIVE, 150 C, 600-VOLT. ` M85485/6-24-* 55FA0414-24-* Tyco Electronics-Raychem 05120201.AJ/01-23-13 M85485/6-24-7L H90062440702 Judd Wire Inc. 05113501.AD/04-30-2014 MIL-C-85485/7, CABLE, ELECTRIC, FILTER LINE, UNSHIELDED, UNJACKETED, MULTIPLE-COMPONENT, RADIO FREQUENCY ABSORPTIVE, 150 C, 600-VOLT. M85485/7-22T2A -20T2A M9002012**12 M9002014**12 Judd Wire Inc. 05113501.AD/04-30-2014 3

M85485/7-18T2A -16T2A -14T2A -22T3A -20T3A -18T3A -16T3A -14T3A -22T4A -20T4A -18T4A -16T4A -14T4A -22T5A -20T5A -18T5A -16T5A -14T5A -24M2A -24M3A -24M4A -24M5A M9002016**12 M9002018**12 M9002020**12 M9003012**12 M9003014**12 M9003016**12 M9003018**12 M9003020**12 M9004012**12 M9004014**12 M9004016**12 M9004018**12 M9004020**12 M9005012**12 M9005014**12 M9005016**12 M9005018**12 M9005020*812 M9002058**12 M9003058**12 M9004058**12 M9005058**12 Judd Wire Inc. (Continued) 05113501.AD/04-30-2014 M85485/7-24M2A 55FA0424-24-* Tyco Electronics-Raychem -24M3A 55FA0434-24-* -24M4A 55FA0444-24-* 05120201.AJ/01-23-13-24M5A 55FA0454-24-* -22T2A 55FA0421-22-* -22T3A 55FA0431-22-* -22T4A 55FA0441-22-* -22T5A 55FA0451-22-* -20T2A 55FA0421-20-* -20T3A 55FA0431-20-* -20T4A 55FA0441-20-* -20T5A 55FA0451-20-* -18T2A 55FA0421-18-* M85485/7-18T3A 55FA0431-18-* 4

-18T4A 55FA0441-18-* Tyco Electronics-Raychem -18T5A 55FA0451-18-* (Continued) -16T2A 55FA0421-16-* 05120201.AJ/01-23-13-16T3A 55FA0431-16-* -16T4A 55FA0441-16-* -16T5A 55FA0451-16-* -14T2A 55FA0421-14-* -14T3A 55FA0431-14-* -14T4A 55FA0441-14-* -14T5A 55FA0451-14-* MIL-C-85485/8, CABLE, ELECTRIC, FILTER LINE, SHIELDED, JACKETED, RADIO FREQUENCY ABSORPTIVE, 150 C, 600-VOLT. M85485/8-22T1A -20T1A -18T1A -16T1A -14T1A -12T1A -10T1A -22T2A -20T2A -18T2A -16T2A -14T2A -22T3A -20T3A -18T3A -16T3A -14T3A -22T4A -20T4A -18T4A -16T4A -14T4A C90010920002 C90010940002 C90010960002 C90010980002 C90011000002 C90011020002 C90011040002 M90020920002 M90020940002 M90020960002 M90020980002 M90021000002 M90030920002 M90030940002 M90030960002 M90030980002 M90031000002 M90040920002 M90040940002 M90040960002 M90040980002 M90041000002 Judd Wire Inc. 05113501.AD/04-30-2014 5

M84545/8-22T5A -20T5A -18T5A -16T5A -14T5A -24M1A -24M2A -24M3A -24M4A -24M5A -24U1A -24U2A -24U3A -24U4A -24U5A -24V1A -24V2A -24V3A -24V4A -24V5A M90050920002 M90050940002 M90050960002 M90050980002 M90051000002 C90011380002 M90021380002 M90031380002 M90041380002 M90051380002 C90011700002 M90021700002 M90021700002 M90041700002 M90051700002 C90011860002 M90021860002 M90031860002 M90041860002 M90051860002 Judd Wire Inc. (Continued) 05113501.AD/04-30-2014 M85485/8-24U1A 55FB1414-24-* Tyco Electronics-Raychem -24U2A 55FB1424-24-* -24U3A 55FB1434-24-* 05120201.AG/12-31-09-24U4A 55FB1444-24-* -24U5A 55FB1454-24-* -22T1A 55FB1411-22-* -22T2A 55FB1421-22-* -22T3A 55FB1431-22-* -22T4A 55FB1441-22-* -22T5A 55FB1451-22-* -20T1A 55FB1411-20-* -20T2A 55FB1421-20-* -20T3A 55FB1431-20-* -20T4A 55FB1441-20-* -20T5A 55FB1451-18-* 6

M85485/8-18T1A 55FB1411-18-* Tyco Electronics-Raychem -18T2A 55FB1421-18-* (continued) -18T3A 55FB1431-18-* 05120201.AJ/01-23-13-18T4A 55FB1441-18-* -18T5A 55FB1451-18-* -16T1A 55FB1411-16-* -16T2A 55FB1421-16-* -16T3A 55FB1431-16-* -16T4A 55FB1441-16-* -16T5A 55FB1451-16-* -14T1A 55FB1411-14-* -14T2A 55FB1421-14-* -14T3A 55FB1431-14-* -14T4A 55FB1441-14-* -14T5A 55FB1451-14-* -12T1A 55FB1411-12-* -10T1A 55FB1411-10-* MIL-C-85485/9, CABLE, ELECTRIC, FILTER LINE, COMPONENT WIRE, TIN-COATED COPPER CONDUCTOR, RADIO FREQUENCY ABSORPTIVE, 150 C, 600-VOLT. M85485/9-22-* H9009224 Judd Wire, Inc. -20-* H9009204-18-* H9009184 05113501.AD/04-30-2014-16-* H9009164-14-* H9009144-12-* H9009126-10-* H9009106 M85485/9-22 -* 55FA0511-22 -* Tyco Electronics-Raychem thru thru 10 10 05120201.AJ/01-23-13 7

MIL-C-85485/10, CABLE, ELECTRIC, FILTER LINE, COMPONENT WIRE, SILVER-COATED HIGH-STRENGTH COPPER ALLOY CONDUCTOR, RADIO FREQUENCY ABSORPTIVE, 150 C, 600-VOLT M85485/10-24-* H9010244**** Judd Wire, Inc. 05113501.AD/04-30-2014 M85485/10-24-* 55FA0514-24-* Tyco Electronics-Raychem 05120201.AJ/01-23-13 MIL-C-85485/11, CABLE, ELECTRIC, FILTER LINE, UNSHIELDED, UNJACKETED, MULTIPLE-COMPONENT, RADIO FREQUENCY ABSORPTIVE, 150 C, 600-VOLT. M85485/11-24T2* M9002220**** Judd Wire, Inc. M85485/11-22T2* M9002222**** M85485/11-20T2* M9002224**** 05113501.AD/04-30-2014 M85485/11-18T2* M9002226**** M85485/11-16T2* M9002228**** M85485/11-14T2* M9002230**** M85485/11-24T3* M85485/11-22T3* M85485/11-20T3* M85485/11-18T3* M85485/11-16T3* M85485/11-14T3* M85485/11-24T4* M85485/11-22T4* M85485/11-20T4* M85485/11-18T4* M85485/11-16T4* M85485/11-14T4* M9003220**** M9003222**** M9003224**** M9003226**** M9003228**** M9003230**** M9004220**** M9004222**** M9004224**** M9004226**** M9004228**** M9004230**** 8

M85485/11-24T5* M9005220**** Judd Wire, Inc. (continued) M85485/11-22T5* M9005222**** (Continued) M85485/11-20T5* M9005224**** 05113501.AD/04-30-2014 M85485/11-18T5* M9005226**** M85485/11-16T5* M9005228**** M85485/11-14T5* M9005230**** M85485/11-24M2* M85485/11-22M2* M85485/11-20M2* M85485/11-18M2* M85485/11-16M2* M85485/11-14M2* M85485/11-24M3* M85485/11-22M3* M85485/11-20M3* M85485/11-18M3* M85485/11-16M3* M85485/11-14M3* M85485/11-24M4* M85485/11-22M4* M85485/11-20M4* M85485/11-18M4* M85485/11-16M4* M85485/11-14M4* M85485/11-24M5* M85485/11-22M5* M85485/11-20M5* M85485/11-18M5* M85485/11-16M5* M85485/11-14M5* M9002268**** M9002270**** M9002272**** M9002274**** M9002276**** M9002278**** M9003268**** M9003270**** M9003272**** M9003274**** M9003276**** M9003278**** M9004268**** M9004270**** M9004272**** M9004274**** M9004276**** M9004278**** M9005268**** M9005270**** M9005272**** M9005274**** M9005276**** M9005278**** 9

M85485/11-24M2* 55FA0524-24-* Tyco Electronics-Raychem -24M3* 55FA0534-24-* -24M4* 55FA0544-24-* 05120201.AJ/01-23-13-24M5* 55FA0554-24-* -22T2* 55FA0521-22-* -22T3* 55FA0531-22-* -22T4* 55FA0541-22-* -22T5* 55FA0551-22-* -20T2* 55FA0521-20-* -20T3* 55FA0531-20-* -20T4* 55FA0541-20-* -20T5* 55FA0551-20-* -18T2* 55FA0521-18-* -18T3* 55FA0531-18-* -18T4* 55FA0541-18-* -18T5* 55FA0551-18-* -16T2* 55FA0521-16-* -16T3* 55FA0531-16-* -16T4* 55FA0541-16-* -16T5* 55FA0551-16-* -14T2* 55FA0521-14-* -14T3* 55FA0531-14-* -14T4* 55FA0541-14-* -14T5* 55FA0551-14-* MIL-C-85485/12, CABLE, ELECTRIC, FILTER LINE, SHIELDED, JACKETED, RADIO FREQUENCY ABSORPTIVE, 150 C, 600-VOLT. M85485/12-24T1* C9001300**** Judd Wire, Inc. M85485/12-22T1* C9001302**** M85485/12-20T1* C9001304**** 05113501.AD/04-30-2014 M85485/12-18T1* C9001306**** M85485/12-16T1* C9001308**** M85485/12-14T1* C9001310**** M85485/12-12T1* C9001312**** M85485/12-10T1* C9001314**** M85485/12-24T2* M9002300**** 10

M85485/12-22T2* M9002302**** Judd Wire, Inc. (continued) M85485/12-20T2* M9002304**** (Continued) M85485/12-18T2* M9002306**** 05113501.AD/04-30-2014 M85485/12-16T2* M9002308**** M85485/12-14T2* M9002310**** M85485/12-24T3* M85485/12-22T3* M85485/12-20T3* M85485/12-18T3* M85485/12-16T3* M85485/12-14T3* M85485/12-24T4* M85485/12-22T4* M85485/12-20T4* M85485/12-18T4* M85485/12-16T4* M85485/12-14T4* M85485/12-24T5* M85485/12-22T5* M85485/12-20T5* M85485/12-18T5* M85485/12-16T5* M85485/12-14T5* M85485/12-24M1* M85485/12-22M1* M85485/12-20M1* M85485/12-18M1* M85485/12-16M1* M85485/12-14M1* M85485/12-12M1* M85485/12-10M1* M85485/12-24M2* M85485/12-22M2* M9003300**** M9003302**** M9003304**** M9003306**** M9003308**** M9003310**** M9004300**** M9004302**** M9004304**** M9004306**** M9004308**** M9004310**** M9005300**** M9005302**** M9005304**** M9005306**** M9005308**** M9005310**** C9001348**** C9001350**** C9001352**** C9001354**** C9001356**** C9001358**** C9001360**** C9001362**** M9002348**** M9002350**** 11

M85485/12-20M2* M9002352**** Judd Wire, Inc M85485/12-18M2* M9002354**** (Continued) M85485/12-16M2* M9002356**** 05113501.AD/04-30-2014 M85485/12-14M2* M9002358**** M85485/12-24M3* M85485/12-22M3* M85485/12-20M3* M85485/12-18M3* M85485/12-16M3* M85485/12-14M3* M85485/12-24M4* M85485/12-22M4* M85485/12-20M4* M85485/12-18M4* M85485/12-16M4* M85485/12-14M4* M85485/12-24M5* M85485/12-22M5* M85485/12-20M5* M85485/12-18M5* M85485/12-16M5* M85485/12-14M5* M85485/12-24U1* M85485/12-22U1* M85485/12-20U1* M85485/12-18U1* M85485/12-16U1* M85485/12-14U1* M85485/12-12U1* M85485/12-10U1* M85485/12-24U2* M85485/12-22U2* M85485/12-20U2* M9003348**** M9003350**** M9003352**** M9003354**** M9003356**** M9003358**** M9004348**** M9004350**** M9004352**** M9004354**** M9004356**** M9004358**** M9005348**** M9005350**** M9005352**** M9005354**** M9005356**** M9005358**** C9001380**** C9001382**** C9001384**** C9001386**** C9001388**** C9001390**** C9001392**** C9001394**** M9002380**** M9002382**** M9002384**** 12

M85485/12-18U2* M9002386**** Judd Wire, Inc. M85485/12-16U2* M9002388**** (Continued) M85485/12-14U2* M9002390**** 05113501.AD/04-30-2014 M85485/12-24U3* M85485/12-22U3* M85485/12-20U3* M85485/12-18U3* M85485/12-16U3* M85485/12-14U3* M85485/12-24U4* M85485/12-22U4* M85485/12-20U4* M85485/12-18U4* M85485/12-16U4* M85485/12-14U4* M85485/12-24U5* M85485/12-22U5* M85485/12-20U5* M85485/12-18U5* M85485/12-16U5* M85485/12-14U5* M85485/12-24V1* M85485/12-22V1* M85485/12-20V1* M85485/12-18V1* M85485/12-16V1* M85485/12-14V1* M85485/12-12V1* M85485/12-10V1* M85485/12-24V2* M85485/12-22V2* M85485/12-20V2* M85485/12-18V2* M9003380**** M9003382**** M9003384**** M9003386**** M9003388**** M9003390**** M9004380**** M9004382**** M9004384**** M9004386**** M9004388**** M9004390**** M9005380**** M9005382**** M9005384**** M9005386**** M9005388**** M9005390**** C9001396**** C9001398**** C9001400**** C9001402**** C9001404**** C9001406**** C9001408**** C9001410**** M9002396**** M9002398**** M9002400**** M9002402**** 13

M85485/12-16V2* M9002404**** Judd Wire, Inc. M85485/12-14V2* M9002406**** (Continued) 05113501.AD/04-30-2014 M85485/12-24V3* M9003396**** M85485/12-22V3* M9003398**** M85485/12-20V3* M9003400**** M85485/12-18V3* M9003402**** M85485/12-16V3* M9003404**** M85485/12-14V3* M9003406**** M85485/12-24V4* M85485/12-22V4* M85485/12-20V4* M85485/12-18V4* M85485/12-16V4* M85485/12-14V4* M85485/12-24V5* M85485/12-22V5* M85485/12-20V5* M85485/12-18V5* M85485/12-16V5* M85485/12-14V5* M9004396**** M9004398**** M9004400**** M9004402**** M9004404**** M9004406**** M9005396**** M9005398**** M9005400**** M9005402**** M9005404**** M9005406**** M85485/12-24U1* 55FB1514-24-* Tyco Electronics-Raychem -24U2* 55FB1524-24-* -24U3* 55FB1534-24-* 05120201.AJ/01-23-13-24U4* 55FB1544-24-* -24U5* 55FB1554-24-* -22T1* 55FB1511-22-* -22T2* 55FB1521-22-* -22T3* 55FB1531-22-* -22T4* 55FB1541-22-* -22T5* 55FB1551-22-* -20T1* 55FB1511-20-* -20T2* 55FB1521-20-* -20T3* 55FB1531-20-* 14

M85485/12-20T4* 55FB1541-20-* Tyco Electronics-Raychem -20T5* 55FB1551-20-* (Continued) -18T1* 55FB1511-18-* -18T2* 55FB1521-18-* 05120201.AJ/01-23-13-18T3* 55FB1531-18-* -18T4* 55FB1541-18-* -18T5* 55FB1551-18-* -16T1* 55FB1511-16-* -16T2* 55FB1521-16-* -16T3* 55FB1531-16-* -16T4* 55FB1541-16-* -16T5* 55FB1551-16-* -14T1* 55FB1511-14-* -14T2* 55FB1521-14-* -14T3* 55FB1531-14-* -14T4* -14T5* -12T1* -10T1* 55FB1541-14-* 55FB1551-14-* 55FB1511-12-* 55FB1511-10-* 15

NAME, ADDRESS AND PLANT CAGE NUMBER NAME, ADDRESS AND PLANT CAGE NUMBER Judd Wire, Inc. 12703 124 Turnpike Road Turners Falls, MA 01376 Plant: Same Address Tyco Electronics-Raychem 06090 300 Constitution Drive Menlo Park, CA 94025 Plants: Tyco Electronics-Raychem Northside at Oakside Redwood City, CA 94063 Tyco Electronics-Tijuana Av. Produccion No. 20 Parque Industrial Internaccional Tij Tijuana B.C. Mexico 22424 362Y2 SU473 16