FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG.

Similar documents
FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item #

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item #

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N

FG-L Technical Data Sheet

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #

P/N _F NSF Certified June 2010

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016

PWEE Technical Data Sheet

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item #

RLNIE with INNOVATOR II

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item #

RL with INNOVATOR II No Heat Doors

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #

RM with INNOVATOR Doors

RLT with INNOVATOR Doors

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

Nosing Heater. Return Grill Heater

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018

RMN with INNOVATOR Doors Technical Data Sheet

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount

Engineering Plan Views

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF

LifeLine Premier RLNIE

LWU Technical Data Sheet

BEXD-8A. P/N _A NSF Certified P/N_ _A C B P E D K. Technical Data Sheet. November 2010

RLNIE P/N G. P/N _G NSF Certified. Technical Data Sheet. Warning: Terminal block NOT for case-to-case wire connection!

RL with INNOVATOR Doors

ISF and ISM. Low and Medium Temperature Remote and Self Contained Island Merchandisers. Installation & Service Manual IMPORTANT

NFW, NCW, NFWG, NCWG, NFWE, NCWE

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB

Installation & Service Manual

Installation & Service Manual

Low Temperature. Installation & Operation Manual IMPORTANT. Single Deck Wall & Island Merchandisers. Keep in store for future reference!

MD Medium Temperature Self Contained Open Vertical Merchandisers

P/N _B September Field Installed Dual Temp Operation E P R Controlled (Evaporator Pressure Regulator)

Installation & Service Manual

GSVM Medium Temperature Self Contained Open Vertical Merchandisers. Installation & Service Manual

MD Medium Temperature Self Contained Open Vertical Merchandisers

Self-Contained MERCHANDISERS. February

HGL- 1, 2 & 3 BS, TS. Bottom / Top Mount Low Temperature Remote and Self Contained Glass Door Merchandisers. Installation & Service Manual IMPORTANT

BCH Medium Temperature Merchandisers

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

Medium Temperature Bulk Produce and Bakery Merchandisers

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

ON3.5EM-NRG ON3.5EM-NRG. Narrow Multi-Deck Merchandiser with Synerg-E End Cap (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT GENERAL NOTES:

Self-Contained MERCHANDISERS. October

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases

F-6 Multi-deck Frozen Food Wall Merchandisers

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES

HGM-1, 2 & 3 BS, TS. Bottom / Top Mount Medium Temperature Remote and Self Contained. Installation & Service Manual. Glass Door Merchandisers

OPTIONAL CONTROLLER. Kit P/N _A. December 2016 ANTI-CONDENSATE HEATER FOR REACH-IN GLASS DOORS. Spanish French

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for future reference!

Self-Contained Medium Temperature Delicatessen, Dairy, Meat, Produce and Bakery Merchandisers

6DMLH-NRG 6DMLH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES

O3UM-NRG O3UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 10', 12' (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT

ISF and ISM Low and Medium Temperature Self Contained Island Merchandisers

Reach-in Merchandisers

RFLNS, RFMNS & RFLTM Freedom Line

OIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA:

Service Merchandisers

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

EcoVision Door Manual

O5MH-NRG O5MH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT

Glass Lids for Low Temperature Single Deck Wall & Island Merchandisers

OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL

O5M-NRG O5M-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

Installation & Service Manual

Glass Doors, Hinged Bottom Mounts

KRSCP Self-Contained Walk-In Unit Installation and Service Manual Addendum

O5DM-NRG O5DM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT Case Weight O5DM-NRG ---

Service Merchandisers

ON4UM-NRG ON4UM-NRG. Narrow Multi-Deck Merchandiser 4', 6', 8', 12' (Dairy/Deli/Produce) SHIPPING WEIGHT GENERAL NOTES

OHMH-NRG OHMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

Rear Roll-in Dairy Medium Temperature Free Standing or Suspended Merchandisers Installed in Walk-in Cooler Exterior Walls

SERIES NAV S Display Merchandisers

RFLN & RFMN Freedom Line

O2.5UM-NRG O2.5UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 12' Case (Dairy/Deli/Meat/Produce/Seafood)

Ultra Low Front Rear Load Medium Temperature

Low Temperature. Installation & Operation Manual. Keep in store for future reference. Single Deck Wall & Island Merchandisers P/N F

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

Field Top Mounted Condensing Unit

Cabinet & Merchandiser Price List

SERIES NIM. Low Temperature Merchandisers PLEASE READ THIS MANUAL BEFORE USING THE PRODUCT

DDFF036 SERIES 11 : CONTROLS [1/15]

Transcription:

E C D E F J G I FWG Technical Data Sheet NSF Certified June 2016 DOE 2012 Energy Efficiency Compliant A We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. H B Item Part # Description Wiring Item # FAN ASSEMBLIES, AND THERMOSTATS A. 4W Standard Energy Efficient Fan Assembly (1) 0477653 Fan Motor, Evaporator (MO.4410544) 0464847 Fan Blade (FB.4780649) B. Optional Adjustable Refrigeration Thermostat (2) C. 0398557 Defrost Termination Thermostat (3) (Front/Electric Defrost only) (CT.4440611) D. 0398558 Defrost Termination Thermostat (3) (Rear/Electric Defrost only) (CT.4481088) E. 0481370 Heater Switch (4) (Koolgas Defrost only) (CT.4440738) HEATERS F. 208V Evaporator Defrost Heaters (5) 0481864 4 ft case (HE.4850637) 0444057 6 ft case (HE.4850620) 0462159 8 ft case (HE.4850603) 0444058 12 ft case (HE.4850571) Data sheet-excel FWG Item Part # Description Wiring Item # HEATERS (CONTINUED) G. 208V Drip Pan Defrost Heaters, Electric (6) 0481865 4 ft case (HE.4850638) 0444300 6 ft case (HE.4850609) 0462160 8 ft case (HE.4850636) 0444296 12 ft case (HE.4850572) 120V Drip Pan Defrost Heaters, Koolgas (7) 0488967 4 ft case (HE.4850641) 0465906 6 ft case (HE.4850628) 0465907 8 ft case (HE.4850622) 0465908 12 ft case (HE.4850623) H. Nosing Anti-sweat Heaters (8) 0495009 4 ft case (HE.4850687) 0495006 6 ft case (HE.4850684) 0495007 8 ft case (HE.4850685) 0495008 12 ft case (HE.4850686) I. Return Grille Anti-sweat Heaters (9) 0495013 4 ft case (HE.4850691) 0495010 6 ft case (HE.4850688 ) 0495011 8 ft case (HE.4850689) 0495012 12 ft case (HE.4850690) J. Return Glass Anti-sweat Heaters (10) 0481867 4 ft case (GL.4978594) 0474775 6 ft case (GL.4977903) 0474778 8 ft case (GL.4987838) 0474779 12 ft case (GL.4987839) Note: Revision M updated refrigeration data on page 3 and updated AHRI Total Display Area on page 5. 2016 HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 MEXICO 1-800-522-1900 WWW.HUSSMANN.COM Spanish 0538923

Engineering Plan Views PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 1 /4 Merchandiser Liquid Line (in.) 3 /8 Merchandiser Suction Line (in.) 5 /8 Wide Island 10-2004 64 ½ (1638) Electrical Field Concection 41 ½ (1054) 8 ½ (217) Waste A Electrical Stub Up Area 6 x 6 (152 x 152) Waste Wireway B D 43 (1114) 4 ¼ (108) Splashguard 4 ¾ (120) 29 ½ (750) Waste Refrigeration Waste 41 ½ (1054) 10 ¼ (261) Dimensions shown as inches & (mm). 12 (307) 4 ½ (115) 8 (203) 26 ½ (673) Splashguard C FRONT (12 Ft shown) 4 ft 6 ft 8 ft 12 ft General (A) Case Length (without ends or partitions) 48 1 /4 (1226) 73 3 /4 (1874) 96 3 /8 (2448) 144 1 /2 (3670) (Each end and insulated partition adds 2 in. (51 mm) to case line up.) Maximum O/S dimension of case back to front (includes bumper) 80 5 /8 (2046) 80 5 /8 (2046) 80 5 /8 (2046) 80 5 /8 (2046) Back of case to front of splashguard 72 (1829) 72 (1829) 72 (1829) 72 (1829) Back of case to O/S edge of front leg 59 3 /4 (1515) 59 3 /4 (1515) 59 3 /4 (1515) 59 3 /4 (1515) Distance between edges of external legs and center legs NA 30 1 /4 (768) 41 1 /2 (1054) 41 1 /2 (1054) Distance between edges of center legs NA NA NA 43 7 /8 (1114) Distance between front legs and splashguard 12 3 /8 (312) 12 3 /8 (312) 12 3 /8 (312) 12 3 /8 (312) Electrical Service (Electrical Field Wiring connection point) (B) RH End of case to center of stub up area 36 1 /8 (918) 61 5 /8 (1565) 84 1 /4 (2140) 132 3 /8 (3363) Back of case to center of stub up area 64 1 /2 (1638) 64 1 /2 (1638) 64 1 /2 (1638) 64 1 /2 (1638) Length of electrical wireway Wireway 26 1 /2 (673) 26 1 /2 (673) 26 1 /2 (673) 26 1 /2 (673) (C) RH End of case to LH end of wireway 40 1 /2 (1029) 67 1 /2 (1715) 90 1 /8 (2289) 138 1 /4 (3511) Waste s (One each end) (D) RH End of case to the center of LH waste outlet 36 1 /8 (918) 61 5 /8 (1565) 84 1 /4 (2140) 132 3 /8 (3363) RH End of case to the center of RH waste outlet 12 1 /8 (307) 12 1 /8 (307) 12 1 /8 (307) 12 1 /8 (307) Back O/S of case to center of waste outlets 70 1 /4 (1784) 70 1 /4 (1784) 70 1 /4 (1784) 70 1 /4 (1784) Schedule 40 PVC drip pipe 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) Refrigeration Back of case to center of front refrigeration outlet 64 7 /8 (1646) 64 7 /8 (1646) 64 7 /8 (1646) 64 7 /8 (1646) Back of case to center of rear refrigeration outlet 15 3 /4 (400) 15 3 /4 (400) 15 3 /4 (400) 15 3 /4 (400) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203) 8 (203) 20 ¾ (529) 59 ¾ (1515) 70 ¼ (1784) 72 (1829) 80 (2046) 2 of 7 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. FWG Technical Data Sheet

Wide Island Display with Glass Walls DOE 2012 Energy Efficiency Compliant Hussmann refrigerated merchandisers configured for sale for use in the United States meet or surpass the requirements of the DOE 2012 energy efficiency standards. Dimensions shown as inches & (mm). 5 ½ (140) Excel FWG REFRIGERATION DATA* Note: This data is based on store temperature and humidity that does not exceed 75 F and 55% R.H. MED FF IC Discharge Air ( F) +24 12 22 Avg Evporator ( F)** +19 20 30 Unit Sizing ( F) +17 23 33 Btu/hr/ft MED FF IC PARALLEL 4 ft/8 ft 413 598 643 6 ft/12 ft 422 607 652 33 (838) Fan Coil Coil Fan 59 ¾ (1517) 4 (101) Refrigeration 1 ½ (37) 3 ¼ (82) 68 (1747) 80 (2046) CONVENTIONAL 4 ft/8 ft 433 623 673 6 ft/12 ft 442 632 682 *Dual temperature operation kits are not suitable for ice cream temperature applications. **For high glide refrigerants, evaporator temperatures listed represent average coil temperature as measured throughout the coil. DEFROST DATA MED FF IC Frequency (hr) 24 24 24 Defrost Water (lb/ft/day) 2.2 2.1 1.8 (± 15% based on case configuration and product loading). ELECTRIC MED FF IC Temp Term ( F) 48 48 48 Failsafe (minutes) 60 60 60 FWG 9 (251) 35 (910) 15 (404) 24 (618) 3 (79) Case-to-Case Connection NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability. 11 ¾ (299) GAS Duration (minutes) NA 15 18 OFFTIME Not Recommended Standard Defrost Thermostat Close on rise: close 48 F open 33 F CONVENTIONAL CONTROLS Low Pressure Backup Control CI/CO ** MED +22 F / +10 F FF 17 F / 29 F IC 27 F / 39 F Indoor Unit Only, Pressure Defrost Termination* Not Recommended ***Use a Temperature Pressure Chart to determine PSIG conversions. Estimated Charge **** 4 ft 1.7 lb 27 oz 0.8 kg 6 ft 2.1 lb 34 oz 1.0 kg 8 ft 2.5 lb 40 oz 1.1 kg 12 ft 3.7 lb 59 oz 1.7 kg ****This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound (8 oz/0.2 kg). HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 3 of 7

Excel FWG Electrical Data 4 ft 6 ft 8 ft 12 ft Number of Fans 4W Evaporator 2 2 4 4 Amperes Watts 4 ft 6 ft 8 ft 12 ft 4 ft 6ft 8 ft 12 ft Evaporator Fans 120V 50/60Hz Standard Energy Efficient 0.24 0.24 0.48 0.48 16 16 32 32 230V 50/60Hz Standard Energy Efficient 0.12 0.12 0.24 0.24 16 16 32 32 230V 60Hz Export 0.30 0.30 0.60 0.60 48 48 96 96 230V 50Hz Export 0.36 0.36 0.72 0.72 54 54 108 108 Anti-sweat Heaters (on fan circuit) 120V 50/60Hz Standard 0.87 1.30 1.74 2.60 104 156 208 312 230V 50/60Hz Export 0.45 0.68 0.90 1.36 104 156 208 312 Minimum Circuit Ampacity 120V 50/60Hz Standard Energy Efficient 1.31 1.74 2.42 3.28 230V 50/60Hz Standard Energy Efficient 0.77 1.00 1.34 1.80 230V 60Hz Export 0.95 1.18 1.70 2.16 230V 50Hz Export 1.01 1.24 1.82 2.28 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Return Glass Anti-sweat Heaters 120V 50/60Hz Standard 0.08 0.13 0.16 0.22 10 15 18 26 230V 50/60Hz Export 0.04 0.07 0.08 0.12 10 15 18 26 208V Electric Defrost 8.75 13.07 15.38 23.07 1820 2720 3200 4800 230V Export Electric Defrost 7.91 11.83 13.91 20.87 1820 2720 3200 4800 120V Koolgas Defrost 2.50 2.67 3.33 6.66 300 320 400 800 208V Koolgas Defrost 1.06 1.54 1.92 3.84 220 320 400 800 230V Koolgas Defrost 1.17 1.70 2.12 4.25 270 400 488 977 Standard Lighting None 4 of 7 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. FWG Technical Data Sheet

Excel FWG Product Data Recommended Usable Cube 1 (Cu Ft/Ft) AHRI Total Display Area 2 (Sq Ft/Ft) Shelf Area 3 (Sq Ft/Ft) 7.28 ft 3 /ft (0.68 m 3 /m) 7.32 ft 2 /ft (2.23 m 2 /m) 5.50 ft 2 /ft (1.68 m 2 /m) 1 AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft 3 /ft [m 3 /m] 2 Computed using AHRI 1200 standard methodology: Total Display Area, ft 2 [m 2 ]/Unit of Length, ft [m] 3 Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is NONE. ESTIMATED SHIPPING WEIGHT 5 Case Solid End 4 ft 6 ft 8 ft 12 ft (each) lb (kg) 1000 (454) 1200 (544) 1400 (635) 1600 (726) 75 (34) 5 Actual weights will vary according to optional kits included. HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 5 of 7

Electric Defrost Standard 120V Power 1 8 9 120V Neutral 4 Ft - 2 Fans 8 Ft - 4 Fans 12 Ft - 4 Fans 1 8 9 Fans Nosing Anti-Sweat Heater Return Grille Anti-Sweat Heater 2 Refrigeration Thermostat (Optional) Light Blue To Condensing Unit L1 208V Power From Defrost Contactors L2 3 Defrost Termination Thermostat To Condensing Unit 6 Drip Pan Heater 5 Electric Defrost Heaters Return Class Anti-Sweat Heater Purple White 10 6 Drip Pan Heater 5 Purple 10 White Electric Defrost Heaters 120V Power 120V Neutral WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled Number = Parts List Item Numbers 6 of 7 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. FWG Technical Data Sheet

Gas Defrost Optional 120V Drip Pan Heater Koolgas Only 7 4 Heater Switch 208V/230V Drip Pan Heater Koolgas Only 7 7 4 Heater Switch 4 Heater Switch 120V Power 120V Neutral L1 L2 L1 L2 WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled Number = Parts List Item Numbers HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 7 of 7