ATEX Vacuum Pumps in Accordance with the Directive 94/9/EG (ATEX 95) Technical Information

Similar documents
Innovative Vacuum Solutions

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

Explosion-protected actuator Page 259 of 292

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

ATEX, NOMENCLATURE AND CODING

VSD AND SS DRIVING ATEX MOTORS February 2014

Root's Blowers. Introduction. Options to Choose from: RUTA Vacuum Systems. Root's Blower Vacuum Pumps. Industrial Series WAU Blower Hydrocarbon Oil

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

ATEX, NOMENCLATURE AND CODING

Ex Products Highest level of safety under the most difficult conditions

Mechanical Vacuum Systems for Secondary Metallurgy Steel Degassing

Implementation of ATEX Guidelines

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

Dual certification! Air handling units for potentially explosive atmospheres

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Beamex. Calibration White Paper. Calibration in hazardous areas

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

OPTIBAR DP 7060 Supplementary Instructions

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Beamex Calibration White Paper. Calibration in hazardous areas

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

ATEX Safety Switches. More than safety.

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

1. GENERAL TECHNICAL INFORMATION

Overview of Hazardous Locations as They Relate to Solenoid Valves

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Ulster Bank Business Achievers Award Emerging Technology

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

[ TECHNOLOGY ] and does this definition affect a burner.

Vacuum in the laboratory. products and solutions

Vacuum Pump Systems Excerpt from the Leybold Full Line Catalog 2018 Catalog Part Vacuum Pump Systems

BINDER Scientific Product Catalog

Phoenix Flameproof. Pan & Tilt heads and Camera Housings for potentially explosive environments.

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

EtherCAT Box Modules (EPxxxx-xxxx)

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY

ATM Lighting sp. z o.o

UL HAZARDOUS LOCATIONS SERVICES

TRASCO ATEX Couplings

4) Intrinsic Safety Certification

Guide to Hazardous Location Approvals:

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

OPTIWAVE X500 Supplementary Instructions

ANNEX GD-CERT-EX-EN SIT

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

IRceL CH4 Methane (CH 4

Hazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations)

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

Guide for hazardous areas

ATLAS COPCO CREATES VACUUM TECHNIQUE

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

ATEX Explained A brief Introduction

ATM Lighting sp. z o.o

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

Competence for Safety. ATEX Category 3 Description. Example of a zone division for combustible fluids (gases) and combustible dust

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Product Overview 2015 Innovative Vacuum Components and Systems for Versatile Applications

A comparison of Vacuum Drying Processes of Food Products

MICROpeL 75 Combustible Gas Sensor Part Number: PM

THE BELGIAN PIONEER IN GAS DETECTION

OPTIBAR P 1010/2010 C Supplementary instructions

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Dräger Polytron SE Ex Fixed Gas Detector

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Explosion protection Marijan Gorše, dipl. ing.

INSTRUCTION MANUAL (ATEX / IECEx)

THE BELGIAN PIONEER IN GAS DETECTION

Intrinsically safe acoustic emission equipment opens the door to permanent monitoring applications in the oil and gas industry

PEPPERL+FUCHS GmbH

General. Applications and Accessories for Oil Diffusion Pumps. leybold. Application. Accessories LEYBOJET 630 DIP DIP DIP DIP 30000

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

manual addendum DELPHI Ex

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

INSTRUCTION MANUAL (ATEX / IECEx)

Hazardous Locations. A look at Hazardous Locations Product Certification. Presented By

FLAMMABLE GAS DETECTOR DAX 3F-C INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FC_MAN01_EN.indd Ver. V1R2

Advance Optima Continuous Gas Analyzers AO2060-Caldos15, -Caldos17, -Magnos106, -Uras14 Category 2G Analyzer Modules

Hazardous area descriptions

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas

testo 316-EX gas leak detector Instruction manual

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

Process Instrumentation. Product Guide. Registered Quality System to ISO 9001

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

STAINLESS STEEL FLAMMABLE GAS DETECTOR DAX 3F-I INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FI_MAN01_EN Ver. V1R2

Vacuum - The Universal Conveying Force Suction and transportation of powders, liquids and gases

DRYVAC SERIES A new idea for smart pumping

S-Series Screw. The nnovation. leader

Understanding Hazardous Locations Concepts

Motorola Professional Series Enhanced ATEX Portable Radios. October 2007

PHOENIXL 300 New Standards in Leak Testing. Technical information

Part I Extraction Process Equipment

INSTRUCTION & SERVICE MANUAL

3M Oldham OLCT 100. Description. Fixed Gas Detector

Transcription:

ATEX Vacuum Pumps in Accordance with the Directive 94/9/EG (ATEX 95) Technical Information 100.90.02

ATEX Certified Vacuum Pumps Oerlikon Leybold Vacuum offers a selection of different types of vacuum pumps, which comply with the safety and health requirements laid down in the ATEX Directive 94/9/EG: Rotary vane vacuum pumps TRIVAC B and SOGEVAC B RUVAC Roots pumps Dry compressing SCREWLINE vacuum pumps These vacuum pumps have been designed for pumping explosive gas mixtures from different explosion hazardous areas. They offer the necessary degree of safety and protection for personnel as well as the upstream and downstream process sections. Typical Applications for ATEX certified vacuum pumps Evacuation of gas cylinders Pumping of solvents in drying and filling applications Propane (R290), Butane (R600), Isobutane (R600a) as well as other refrigerants, which are used to fill refrigerant systems Pumping of solvent/air mixtures from distillation processes Vacuum sintering with hydrogen process step to remove binders Pharmaceutical freeze-drying Plasma coating processes with flammable precursors Kerosene vapor phase drying processes Fuel recycling Pumping out ammonia residues in nitriding processes TRIVAC D 16 B ATEX with flame arresters Vacuum Pump Type Overview and Classification* Type Model / Line Classification inside (i) outside (o) TRIVAC B, Cat. 3(i) II (i) 3G IIC T4 (50 Hz) II (i) 3G IIC T3 (60 Hz) B, Cat. 3(i/o) II (i) 3G IIC T4 (50 Hz) (o) 3G IIC D 16 B ATEX, 1(i)/2(o) II (i) 1G IIB3 T4 (50 Hz) (o) 2G IIB T4 II (i) 1G IIC (no C2H2, CS2) T4 (50 Hz) (o) 2G IIC T4 SOGEVAC SV40 ATEX IIA II (i)1g IIA T3 (o) 2G IIA T3 SV40 ATEX IIB + H2 II (i)1g IIB+H2 T4 (50 Hz) (o) 2G IIB+H2 T4 II (i)1g IIB+H2 T3 (160 C) (60 Hz) (o) 2G IIB+H2 160 C SV B ATEX Cat.3 II (i) 3G IIC T3 (o) 3GD IIC T3 RUVAC WA/WAU II (i) 3G IIC T3 II (i) 3G IIC T3 (50 Hz) II (i) 3G IIC T4 (50 Hz) (o) 3G IIC T3 (o) 3G IIC T4 SCREWLINE SP 250 (50/60 Hz) II (i) 3GD IIC T3 (160 C) X SP 250 (50/60 Hz) II (i) 3GD IIC T3 (160 C) (o) 3GD EEx na IIC T3 (160 C)X SP 250 (50 Hz) II (i) 2Gb 3D IIC T4 (o) 3GD EEx na IIC T3 (160 C)X SP 250 (60 Hz) II (i) 2Gb 3D IIC T3 (160 C) (o) 3GD EEx na IIC T3 (160 C)X SP 630 (50/60 Hz) II (i) 3G IIC T3 (160 C) X SP 630 (50/60 Hz) II (i) 2Gb 3D IIC T3 (160 C) (o) 3GD EEx na IIC T3 (160 C)X * of vacuum pumps in accordance with ATEX (extract)

ATEX (94/9/EG) Compliant Rotary Vane Vacuum Pumps SOGEVAC ATEX These pumps are equipped with corresponding ATEX motors. The plastic parts are antistatic as well as the exhaust oil mist separator filters. SOGEVAC SV 40 ATEX Fitted with diaphragm pressure controller MR 40 is optionally possible PTB tested explosion proof design Flame arresters on the inlet and outlet sides Pressure sensor to monitor the pressure in the oil housing Pt100 temperature sensor for vacuum generator monitoring IIB+H2 version with additional Pt100 temperature sensor for temperature monitoring at the inlet Connection option at the gas ballast for inerting gas SOGEVAC SV 300 ATEX TRIVAC ATEX The inside and outside of the pump complies with the basic safety requirements of the EU Directive 94/9/EG. For special requirements, the TRIVAC D 16 B ATEX is available for use in explosion hazard zone 1. TRIVAC D 16 B ATEX Flame arresters on the inlet and outlet sides Pressure monitoring by a pressure sensor Temperature monitoring on the inlet and outlet sides Explosion-proof design of housing and motor SOGEVAC SV 40 B to SV 750 B ATEX Cat. 3/3 Pt100 temperature sensor for vacuum generator monitoring Connection option at the gas ballast for inerting gas Motor fitted with PTC resistors Water cooled version (SV 300 to SV 750 B) Free of copper containing metals (SV 200 to SV 750 B) SOGEVAC SV 300 ATEX detail

in Accordance with Directive 94/9/EG (ATEX 95) ATEX (94/9/EG) Compliant Rotary Vane Vacuum Pumps Roots Pumps RUVAC WA / WAU ATEX certified Roots pumps are available for the lines RUVAC WA / WAU 251/501/1001/2001. They comply with ATEX Category 3 (inside), as well as Category 3 (inside) and (outside) and are equipped with motors which comply with temperature classes T3 or T4. The RUVAC Roots pumps WA/WAU can optionally be equipped with a temperature monitoring facility (Pt 100 temperature sensor) ATEX compliant pump system with SOGEVAC SV 300 and RUVAC WAU 1001 Screw Pumps SCREWLINE SP The screw pumps from the lines SCREWLINE SP250 ATEX and SP630 ATEX comply with Category 3 (inside) respectively 2 inside and 3 outside. These pumps comply with the basic safety requirements laid down in ATEX Directive 94/9/EG. As standard, all SCREWLINE ATEX pumps are equipped with a barrier gas control unit.

Classification in Accordance with 94/9/EG Vacuum pumps for pumping flammable gases or vapors and explosive gas mixtures or vapors - gas explosion protection - in accordance with the EU ATEX Directive Areas of Application Vacuum pumps which shall be used for pumping flammable or explosive gas mixtures must fulfil special safety requirements. Most vacuum processes are running below the minimum ignition pressure (< 50 mbar). For this reason the systems are safe even in the case of malfunctions. However, there exists a risk in the vacuum pump, where the pressure of the ignitable gas mixture is above the minimum ignition pressure. Ignition Sources Potential ignition sources in vacuum pumps: Hot surfaces Compression heat Mechanically produced sparks Sparks caused by static electricity Electrically produced sparks Chemical reactions Classification The certified vacuum pumps from Oerlikon Leybold Vacuum comply as to their design and manufacture with the basic requirements laid down in the ATEX Directive (Directive 94/9/EG) which applies to equipment and protective systems intended for use in potentially explosive atmospheres, specifically belonging to Equipment Group II, Category 3 to Category 1. If the category differs between the inside (i), i.e. the process side and the outside (o) - pump sections which do not come into contact with the process gas - then this is stated separately. Moreover, a classification is effected according to gas groups and temperature classes. The Operator Directive A conforming utilisation of products in connection with explosive atmospheres is a requirement for being able to ensure the highest possible degree of safety for personnel and systems. The European Directive 99/92/EG - also called ATEX Operator Directive - demands the compilation of an explosion protection document. In this document the operator defines the minimum requirements regarding the safety engineering aspects for his particular application. For the purpose of fulfilling the requirements of the ATEX Operator Directive, the questionnaire overleaf has been included to assist you in selecting the vacuum pump best suited for your purpose. Please state your specific requirements there. Based on this information Oerlikon Leybold Vacuum will prepare an offer without obligation for a corresponding pump which should meet your requirements. ATEX Marking Ex Zones and Equipment Categories II 1(i) / 2 (o) G IIC T4 (12 C < T a < 40 C) X Special requirements Ambient conditions Temperature class T4 (< 135 C) Gas group IIC Type of explosive atmosphere: gas or vapor Category 2 outside, i.e. in the vicintiy of the pump (installation location) Category 1 inside, i.e. within the pump (process area) Equipment group II, i.e. not suited for mining applications Explosion protection icon Marking example: certified rotary vane pump TRIVAC D 16 B ATEX Explosive Zone* Category* Probability that atmosphere the pump is an ignition source Constant, No ignition source, long-term or 0 1 even not in the frequently event of rare present malfunctions To be expected No ignition source, from time to 1 2 also in case of time malfunctions Rarely, and No ignition source even if present 2 3 during normal then only briefly operation * Rating for the inside and outside of the pump, resp.

Fax Reply +49 (0)221 347 1245 Enquiry Regarding the Minimum Requirements According to Your Explosion Protection Document Please send this questionnaire by fax or E-mail to your Oerlikon Leybold Vacuum contact your local sales representative. Should you require assistance please use the general E-mail address: sales.vacuum@oerlikon.com From company: _ Name/department: _ E-mail: Tel.: _ Fax: _ Date: _ Thank you for your interest in Oerlikon Leybold Vacuum pumps, certified in accordance with ATEX directives. In order to select the vacuum pump best suited for your application, Oerlikon Leybold Vacuum requires the appropriate conditions for the specific application. Please take this information from the explosion protection document, the compilation of which is mandatory to you as the operator. Please fill in this page with care. Completeness of the information is essential. The correctness of the information will decide as to the required degree of safety for personnel and systems. In case you have any questions on this topic or require the design of vacuum pump technology in accordance with your specifications, then our application consultants will be pleased to help you. Please first propose the desired vacuum pump and the pumping speed: Please cross: 1. There is an explosive atmosphere (no mining applications) (i) within the pump (o) outside the pump Please state for each of the following the explosive atmosphere. (i) (o) 2. Zone (ignitable atmosphere) 0 Danger constant, long-term, frequent 1 Danger from time to time 2 Rare danger Please send me an offer. TRIVAC m 3 /h RUVAC m 3 /h 3. Gas group Gas/pumped medium: aggressive corrosive toxic radioactive (i) (o) I methane, for example II A propane, for example II B ethylene, for example II B1 II B2 II B3 II C hydrogen, for example Others (please state) Please answer the following questions: SOGEVAC m 3 /h SCREWLINE m 3 /h 4. Temperature class (maximum desired surface temperature of the operating agent) (i) (o) T1 up to 450 C max. T2 up to 300 C max. T3 up to 200 C max. T4 up to 135 C max. T5 up to 100 C max. T6 up to 85 C max. (please cross; duplicates are allowed) City/date Name/signature Company stamp Headquarter Germany Oerlikon Leybold Vacuum GmbH Bonner Strasse 498 D-50968 Cologne T +49 (0) 221-347-0 F +49 (0) 221-347-1250 info.vacuum@oerlikon.com www.oerlikon.com BICOM 09144.02-100.90.02 1.5.03.07 pe Printed in Germany on chlorine-free bleached paper Technical alterations reserved