Fire Safety. Installation Instructions Model D2300CPS Fiber Optic Interface INTRODUCTION MOUNTING ELECTRICAL CONNECTIONS. Figure 1 D2300CPS Module

Similar documents
IFS Fiber Module Installation & Operation

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

IFS SFP Tranceivers User Manual

Installation Instructions Model CDC-4

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

Fire Safety. Installation Instructions. Model RCC-2/R and RSE-1 Remote Control Centers OPERATION INTRODUCTION INSTALLATION

MXL/MXLV 19 Rack Mount Equipment

TruVision Bullet IR Camera Pocket Guide

TruVision Bullet IR Camera Pocket Guide

Installation Instructions Model DLC

KM300 Carbon Monoxide Detection System Installation Manual

Fire Safety. Installation Instructions Model MMB-2 Main Control Board OPERATION. INSTALLATION Always remove power before installation.

Installation Instructions Model HZM

Installation Instructions Model SSD-C-REM

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

MXL/MXLV Enclosuress & Equipment Models: MME-3, MBR-MP, MLE-6, MBR-3MP, MDL-1, MDB-1, MDG-1, MHD-1, MHD-2, MHD-3, MHD-4

SIGA-CC1 Single Input Signal Module Installation Sheet

Installation Manual. Wiegand Interface Unit Four-State (WIU-4) North America T F Asia T F

R Series Remote Annunciators and Expander Installation and Operation Guide

FEC403EN Installation Manual

R-Series Remote Annunciators and Expanders Installation and Operation Guide

Fire Safety. Installation Instructions Model PSR-1 Remote Power Supply INTRODUCTION. Figure 1 PSR-1 Remote Power Supply

FTP-1000 Touchpad/Display Installation Manual

AND ARCHITECT SPECIFICATIONS

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

safety & regulatory information

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

KFP-CF Series Operation Manual

3M Benchtop Air Ionizer 963E. User s Guide

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens.

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Remote Booster Power Supply Technical Reference Manual

Advisor Advanced User Guide

Panel Remote Annunciators Installation Instructions

Pet Immune SAW PIR Motion Sensor

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005

CZ-6A Six Zone Interface Module

Fire Safety. Installation Instructions Model NIM-1W Network Interface Module MXL NETWORK INTERFACE APPLICATIONS OPERATION NIM-1W

Advanced Protection System

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

ZP2 Series Operation Manual

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

Booster Power Supply Manual

Copyright Notice. Thinklogical, LLC 100 Washington Street Milford, Connecticut U.S.A. Telephone:

Wireless High Bay Sensor (WHS100) Installation Instructions

1X-F Series Installation Manual

Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide. Version A0 Part Number UM-102 September 2005

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

ShockLink. Important Product Information.

Operating Instructions MXL Multi-Line Keyboard/Display Panel

4100U City and Relay Cards Installation Instructions

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features

Fire Safety. Installation Instructions. Model ADBX-11. Audible Base INTRODUCTION. Model ADBX-11

Concord 5 TouchScreen Installation Sheet

Installation Manual. Wiegand Interface Unit Two-State (WIU-2) North America T F Asia T F

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

4009 Fiber Optic Link Option Installation Instructions

/9308 External Battery Chargers Installation Instructions


(EN) RevC AS610-AS630 Outdoor Siren Installation Sheet.pdf. Remark: Rev. Date: Modif. no.

KONICA MINOLTA GP-502 OPERATION MANUAL

Network Camera. Quick Guide DC-T1233WHX. Powered by

Premier External TD. Installation Manual INS352-3

METEOROLOGICAL INSTRUMENTS

KFP-AF Series Fire Alarm Control Panel Installation Manual

NX-181xx NetworX Voice keypad with touch buttons User Manual

field SENSE EC-FS2-001-A

ANNUNCIATOR FIXED MODULE

4120 Fire Alarm Network Reference

Model 17A00 Expansion Enclosure

NetworX NX-548E Receiver Installation Instructions

TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide

TruPortal Wireless Locks Quick Reference

Fiber Optic Cable Fence Disturbance Sensor

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

RMS/RPX Reader. User Manual

IDP-Zone-6 Six Zone Interface Module

FCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE. Field Charger/Power Supply

G4 Pulsed Fiber Laser

System Overview (continued) System Components. The FireFinder XLS system has been seismic qualified in accordance with:

1 UL 864 Compliance. 2 Product Overview. Network Communications Module NCM-W/F Product Installation Document. 1.1 Products Subject to AHJ Approval

MMF Six Zone Interface Module

Installation Manual For The Mxl Panel READ ONLINE

MXL-IQ CONTROL PANEL. Operation, Installation, and Maintenance Manual. Siemens Industry, Inc. Building Technologies Division Florham Park, NJ

Instruction Manual. Satellite Switched, Power Monitoring Unit. RS2 Series

UC-331-UCX Dual Path Communication Module. Quick Start Guide

Install Guide TP-2014-IG-V02

TLM-1 TOWER LIGHT MONITOR V3.0. INSTALLATION and OPERATING INSTRUCTIONS

Network Display Unit Installation Instructions

Installation Instructions Model MDACT MXL/FireFinder-XLS Multi-Point Digital Alarm Communicator

Transcription:

Fire Safety Installation Instructions Model Fiber Optic Interface INTRODUCTION The Model from Siemens uilding Technologies, Inc. (See Figure 1) is a Fiber Optic interface for the MXL s RS-485 network (MNET or XNET) or the FireFinder XLS network (HNET or XNET). It uses a two-fiber (duplex) pair between each device. The can function as either a repeater or an end point unit. RS485 - +-1 +24 VDC -1 WRNING: This module is NOT backwards compatible with the existing 2300CP. This unit uses +24VDC. Make sure to read the front of the module and connect to the correct voltage. Otherwise, serious damage to the unit will result. Figure 1 Module The can operate in either a daisy chain (See Figure 2) or star configuration (See Figure 3). This allows for network configurations that are not possible with the RS-485 network alone. WRNING: The module is not listed for use by Factory Mutual. pplications requiring fiber connectivity of voice modules/systems are therefore not Factory Mutual listed. WRNING: Do not use the with CXL Systems. MOUNTING The has four keyhole slots for #6 screws. Mount the device in the locations listed below using the four #6 screws provided. bracket (P/N 500-692880) is available for mounting the in any MXL enclosure that will accept a MOM-4 (See Figure 4). This bracket has the same footprint as the MOM-4 and accommodates two modules. n assembly kit is included with the bracket that contains four nuts and eight screws. Mount the bracket in the enclosure with the four nuts at the positions labeled X (See Figure 4). Start four of the 6-32 screws and slip the keyhole slots in the over them. Tighten the four screws. System 3 style rails that mount on an MR or MME-3 backbox (P/N MSR-1) are also available and can be used for mounting the with the System 3 MPFO racket. Up to three brackets can be installed on a single rail. bracket, Model D2300-MP, is available for mounting two modules in any FireFinder XLS C enclosure. The D2300-MP fits in the same footprint as a CC-5 and mounts to the C-MP. hardware kit is provided for attaching the D2300-MP to the C-MP and mounting two modules onto the D2300-MP. Mount the modules prior to installing the D2300-MP onto the C-MP. Note that when using two modules, the center two mounting holes on each share the two center studs on the D2300-MP (See Figure 5). ELECTRICL CONNECTIONS INPUT The uses filtered or unfiltered 24 VDC. The can only be powered from the sources listed in Table 1 on page 6. Siemens uilding Technologies, Inc. 8 Fernwood Road Florham Park, New Jersey 07932 Siemens uilding Technologies, Ltd. 2 Kenview oulevard rampton, Ontario L6T 5E4 CN P/N 315-050018-0

DUPLEX OPTICL FIER UDGET - MX LOSS -13 d 62.5/125 FIER - 9 d 50/125 FIER DUPLEX OPTICL FIER UDGET - MX LOSS -13 d 62.5/125 FIER - 9 d 50/125 FIER NO CONNECTION NO CONNECTION XTM - + -1 +24 VDC -1 - + -1 +24 VDC -1 - + -1 +24 VDC -1 RS-485 32 NODES MX RCC-1 PSR-1 RS-485 32 NODES MX RCC-1 MM RS-485 32 NODES MX USE THE 120 ¼ W, 5% EOL RESISTOR SSEMLY, S PPLICLE: (MM-1/) OR P/N 140-049099 (MM-3) PSR-1 Figure 2 Daisy Chain Configuration (MNET Shown) 2

DUPLEX OPTICL FIER UDGET - MX LOSS -13 d 62.5/125 FIER - 9 d 50/125 FIER NO CONNECTION NO CONNECTION NO CONNECTION TO DDITIONL MODULES XTM P P P P - + -1 +24 VDC -1 - + -1 +24 VDC -1 - + -1 +24 VDC -1 RS-485 32 NODES MX PSR-1 MM USE THE 120 ¼ W, 5% EOL RESISTOR SSEMLY, S PPLICLE: (MM-1/) OR P/N 140-049099 (MM-3) PSR-1 Figure 3 Star Configuration (MNET Shown) 3

X - + -1 +24 VDC -1 RCKET P/N 500-692880 P P P P OMM-1 P P P P - + -1 +24 VDC -1 X WRNING DISCONNECT PRIOR TO REMOVING TERMINL LOCK PROTECTION Figure 4 Mounting the in an MR or MME-3 ackbox FIER OPTIC CLE LIMITED HNET/XNET ROUTE S SHOWN D2300-MP NIC-C DLC P5 1 1 P4 4 3 7 2 1 T1 6 12 _ + 1 2 T3 +24 VDC -1 - + -1 +24 VDC -1 - + -1 RESET CRD FIL CN FIL HNET FIL XNET FIL GND FULT LOOP FIL LOOP FIL CTIVE NETWORKS CN HNET XNET HNET/XNET STYLE STYLE 7 STYLE 4 GROUND FULT ENLED DISLED Z O N E 1 Z O N E 2 RESET CRD FIL HNET FIL GND FULT LRM TROULE ZONES STTUS CLSS OPEN CLSS RETURN SHORT CLSS OPEN CLSS RETURN SHORT PSC-12 RESET MODULE FIL CN FIL HNET FIL GND FULT 24V 12 FIL 24V 4 FIL + + + 1 2 3 - - - HNET NETWORK PORT + + + 1 2 3 - - - HNET + + + 1 2 3 - - - HNET TTERY O OFF ON 19 13 T2 24 18 1 2 _ T4 + P12 H N GND P9 _ + C-1 Figure 5 Mounting the in a C-1 ackbox 4

N.C. N.C. END POINT FCP UDGET - MX LOSS -13 d 62.5/125 FIER - 9 d 50/125 FIER RS-485 NETWORK MNET/HNET/XNET (SEE FIGURES 7, 8&9) REPETER FCP UDGET - MX LOSS -13 d 62.5/125 FIER - 9 d 50/125 FIER N.C. N.C. END POINT Figure 6 Wiring the as both a Repeater and End Point Unit FCP RS-485 RTINGS: 8V P-P 150m MX 80 OHMS MX 18 WG MIN - + -1 USE THE 120 ¼ W, 5% EOL RESISTOR SSEMLY, S PPLICLE: (MM-1/) OR P/N 140-049099 (MM-3) STYLE 4 MNET MM T1 4 () 3 () 2 1 - + -1 RS-485 RTINGS: 8V P-P 150m MX 80 OHMS MX 18 WG MIN - + -1 REFER TO NET-7 INSTLLTION INSTRUCTIONS P/N 315-091914 1 2 3 4 T1 NET-7 STYLE 7 MNET MOM-4 Figure 7 Wiring the RS-485 MNET Network in Style 4 and Style 7 5

SYSTEM Table 1 SOURCE MXL MM: T1 4-5; T5 9-12 MM-3: T9 +,-; T5 9-12 PSR-1: T3 1; 3-6 FireFinder XLS PSC-12: T4 +, - PSX-12: T4 +,- SOURCE PD-3 UX +, - PS-35 T1 5-6 For non-power limited wiring, the PLM-35 (Installation Instructions P/N 315-093495) must be used to comply with NFP 70 per NEC 760. ll wiring must be in accordance with rticle 760 of NEC or local building codes. For additional information on the MXL/MXLV System, refer to the MXL/MXLV Manual, P/N 315-092036. 24 VDC CURRENT CLCULTION (MXL ONLY) The 24 VDC output ratings for the MM/SM and PSR-1 are: MM/-3 6 at 24 VDC (MPS-6); 12 at 24 VDC (MPS-12) SM 6 at 24 VDC (MPS-6); 12 at 24 VDC (MPS-12) PSR-1 6 at 24 VDC (MPS-6); 12 at 24 VDC (MPS-12) The following modules all draw current from the 24 VDC supply. dd the value for each module that is installed in the enclosure where the is to be installed. e sure to include the in this calculation. MODULE CTIVE 24 VDC MODULE CURRENT QUNTIT Y TOTL CM-1 85m SC-1 41m SC 61m CMI-300 0m CRM-4 CSM-4 CZM-4 75m 34m + 1.5 max per circuit 720m 4 zones in alarm 57m MK/-4 0m NET-4 0m NET-7 0m NET-7M 0m MOI-7 120m MOD-16 850m max MID-16 32m max PIM-1 0m TC-1 44m RCM-1 130m ZC-30 3 at 30W OCC-1 17m ZC1-8 170m ZC2-8 342m ZC2-4 167m ZC3-4 168m ZCT-8 78m TOTL 6

* - + -1 * * RS-485 RTINGS: 8V P-P 150m MX 80 OHMS MX 18 WG MIN - + -1 *OMIT THIS EQUIPMENT FOR STYLE 4 XNET REFER TO NIM-1R OR NIM-1W INSTLLTION INSTRUCTIONS P/N 315-092953 OR P/N 315-099165, S PPLICLE Figure 8 Wiring the RS-485 XNET Network in Style 4 and Style 7 (MXL) 1 2 3 4 NIM-1R/-1W T3 MOM-4 RS-485 NETWORK The RS-485 MNET, XNET and HNET networks connect to the on the terminal block with the markings + (1) and -(2). Terminals 3 and 4 are not used. For Style 4 networks one is needed at each Fiber Optic drop. For Style 7 networks two modules are needed at each drop.end of line devices are required on each RS-485 pair in the system. Install them at the extreme ends of each pair. Refer to Figures 7 and 8 (MXL) and Figure 9 (FireFinder XLS) for wiring instructions and ratings for both Style 4 and Style 7. NOTE: Positive and negative ground fault detected when terminals shorted to earth. FIER CONNECTIONS The can function as both a repeater and an end point unit. When used as an end point, connect to the fiber connectors labeled. Make no connection to the connectors. In the repeater mode, use both pairs of connectors, and. Two Fiber Optic cables are required between each pair of modules. Use a high quality duplex Fiber Optic cable containing either 50/125 or 62.5/125 fiber. Duplex fiber optic cable has two cables in a single shield similar to electrical zip cord. Use ST style fiber connectors. Please contact the fiber manufacturer regarding instructions for terminating the fiber. 7 When installing the fiber pairs, each fiber must connect between the transmit data ( ) on one and the receive data line ( ) on the other. The fiber connection is classified as Style DCL per ULC-527. INDICTORS The has five LED indicators for Power and Status. The LEDs are located on the side of the module with the Fiber Optic connectors. The Power LED is green and lights whenever there is 24 VDC. oth channels and have a yellow and green LED. The green LED indicates that the is transmitting data on that channel. The yellow LED lights when data is received. ELECTRICL RTINGS ctive Standby 24VDC Module Current Input Power attery Power RS-485 Transmitter Power 24VDC Module Current 57m 57m 18-31 VDC, 57m max 24 VDC, 57m max 8V (P-P), 150m max 20µW (-17dm) (62.5/125 Fiber)

- + -1 RS-485 RTINGS: 8V P-P 150m MX 80 OHMS MX 18 WG MIN NO REQUIRED T THE NIC-C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 NIC-C ONE SLOT OF CC-5/CC 17 18 19 20 21 22 23 24 STYLE 4 HNET/XNET - + -1 - + -1 RS-485 RTINGS: 8V P-P 150m MX 80 OHMS MX 18 WG MIN NO REQUIRED T THE NIC-C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 NIC-C ONE SLOT OF CC-5/CC STYLE 7 HNET/XNET 17 18 19 20 21 22 23 24 P/N 315-050018-0 Figure 9 Wiring the RS-485 HNET or XNET Network in Style 4 and Style 7 (FireFinder XLS)

Contacting us For help installing, operating, maintaining, and troubleshooting this product, refer to this document and any other documentation provided. If you still have questions, contact us during business hours (Monday through Friday, excluding holidays, between 5 a.m. and 5 p.m. Pacific Time). Table 3. Sales and support contact information Sales Technical support Phone: E-mail Toll-free: 888.437.3287 in the US, including laska and Hawaii; Puerto Rico; Canada. Outside the toll-free area: 503.885.5700. techsupport@interlogix.com Fax 888.329.0331 888.329.0332 Note: e ready at the equipment before calling. Online nother great resource for assistance with your Interlogix product is our online publication library. To access the library, go to our website at the following location: http://www.interlogix.com 1 1. Many Interlogix documents are provided as PDFs (portable document format). To read these documents, you will need dobe Reader, which can be downloaded free from dobe s website at www.adobe.com.

Copyright Trademarks and patents Manufacturer Certification FCC compliance CM compliance Canada European Union directives 2011 UTC Fire & Security. ll rights reserved. Interlogix and IFS names and logos are trademarks of UTC Fire & Security. Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products. UTC Fire & Security mericas Corporation, Inc. 2955 Red Hill venue, Costa Mesa, C 92626-5923, US uthorized EU manufacturing representative: UTC Fire & Security.V. Kelvinstraat 7, 6003 DH Weert, The Netherlands N4131 Class : This equipment has been tested and found to comply with the limits for a Class digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Notice! This is a Class product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. This Class digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe est conforme à la norme NM-003 du Canada. 2004/108/EC (EMC directive): Hereby, UTC Fire & Security declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2004/108/EC. 2002/96/EC (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info. Contact information For contact information, see www.interlogix.com.