PGAS-20 Series. Pump-priming Portable Gas Detector Operation Manual

Similar documents
IMR IX176 Portable Gas Detector User Manual

EST User Manual. (Please read this manual carefully before using)

E1000 Portable gas detector

IMR EX610. Portable Gas Detector. Operation Manual

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

Using the QRAE Plus personal multigas monitor

RAE Systems Systems. User Presentation. October Protection Through Detection

Operate the Mutli-Gas Monitor PID

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

Safe Operation Manual. Honeywell IQ Force Gas Detector

GasAlertMicroClip X3 Specifications

ENMET Corporation. PO Box 979 Ann Arbor, MI RECON. Manual. Manual Part Number MCN-410, 12/03/08

MGC Dock User s Manual

Single Gas Monitor 777

ALTAIR 5X Multigas Detector Product Specification

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

USER MANUAL MINITRACER PORTABLE SNIFFER

1, 2, 3, and 4-Gas Detector. Technical Reference Guide

MGC Dock User s Manual

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

BST-MG07 Multi-gas Detecting Alarm Manual Instruction

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Personal Single Gas Monitor. Activation Operation Troubleshooting

PGM100 Carbon Monoxide

MULTI-GAS MONITOR. Eastern Energy Co., Ltd. 40/4 Vitoondumri Rd., Banbueng Banbueng, Chonburi, Thailand

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Operations Manual TS400. Test Station for G450/G460 Gas Detector

RECON/4a Portable Multi-Gas Detector Operation and Maintenance Manual

Contents. Outline of Product. Features of Product. Specifications of Product. Name and central function of section. Illustration of Terminal

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Reference Manual. MultiVision Gas Detector

Fixed Life Single Gas Monitor

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

SCAN200E USER S MANUAL

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

Model:AS8900 MULTI-GAS MONITOR O 2 %VOL H 2S PPM LEL%VOL CO PPM. Version number:as

Single Gas Clip and SGC Plus User s Manual Rev 2.3

EXPERT TRI-STAR. Temperature controller. User s Manual

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

Dräger X-am 2500 (MQG 0011) Technical Manual

MiniRAE 3000 ppbrae Basic Operation Pocket Reference

Single Gas Clip and SGC Plus User s Manual Rev 2.1 READ FIRST BEFORE OPERATION WARNING STATEMENTS / AVERTISSEMENT Activating tthe detector for the

GasAlertMicro 5. 1, 2, 3, 4, and 5 Gas Detectors. Quick Reference Guide

Fire Command Keypad. XR5 User s Guide

Technical Reference Guide. 1, 2, 3, and 4-Gas Detector

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Sirius MultiGas Detector

FlameGard 5 MSIR HART

TARGET Series Portable Gas Detector Operation & Maintenance Manual

Dräger X-am 7000 Multi-Gas Detection

Instruction Manual Eagle Series

UltraRAE 3000 Basic Operation Pocket Reference

1, 2, 3, and 4-Gas Detector. Technical Reference Guide

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

Activation Operation Troubleshooting Part Number: Edition: Release Date:

QUICK REFERENCE GUIDE

Instruction Manual QUICK 855PG PROGRAMMABLE SMD REWORK STAION

FlameGard 5 UV/IR HART

HRS55PG PROGRAMMABLE SMD REWORK STAION. Instruction Manual. Thank you for purchasing our SMD Rework station. The unit is exclusively designed for

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

INSTRUCTION MANUAL MODEL GX-82A

DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station.

Using the MiniRAE 2000 & ppbrae PID

RAE Systems. Using the MeshGuard. Protection Through Detection

KANE-ALERT-CO 2 Monitor with Temperature

Clip SGD. Portable single Gas Detector. User manual

1.1 Definitions of alert icons. For your safety

Operating Instructions and Maintenance Manual

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

Bacharach Bodyguard 4 User's Guide

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Operations Manual DS 220. Docking Station for Micro IV

NexSysLink. 2 CAN Display Operation Manual. CAN Instruments Product Family

Dräger X-am approved as type MQG 0010 Multi-Gas Monitor Technical Manual _01.eps

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

OI-2400-DOCK Multi Gas Docking Station. Operation Manual trevision 2.2w

SC-01 Operator s Manual

RAE Systems RAE Systems RAE Systems Presented by David Lucha RAE Systems Protectio n Through Detection

VASTHI ENGINEERS. Vasthi Explosive Meter Sheet No. 1 of 5. Vasthi Monitors for Combustible Gas.

Dräger X-am approved as type MQG 01** Multi-Gas Monitor. Technical Handbook. CO2 Vol% CH4 %UEG. CO ppm. ppm NH _01.

Intruder alarm panel Terxon MX Operating instructions

NH 3 RESPONDER Portable Ammonia Leak Detector QUICK REFERENCE GUIDE

PROCESS ANALYSERS. SERVOFLEX MiniMP (5200) Gas Analyser. Operator Manual. Part Number: A Revision: 8 Language: UK English

TM-802 Formaldehyde Meter User s Manual

GasAlertMicro 5 and GasAlertMicro 5 PID O 2, CO, H 2 S, PH 3, SO 2, Cl 2, NH 3, NO 2, HCN, ClO 2, O 3, VOC, and Combustibles

System. For a better understanding of this product, please read this user manual thoroughly before using it.

Halton SAFE / 7.14 user guide and installation instructions

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Reference Manual. MultiPro Gas Detector

Security System. User Guide for the LED Command Center

Reference Manual MultiPro Gas Detector

Multi-gas Monitor. Product Manual Set-up Operation Service. Part Number: Version 12

Portable Gas Detector Instruction Manual

CSP-204 CSP-208 CSP-104 CSP-108

Warranty Registration

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

Tri-Tech Medical Inc.

Transcription:

PGAS-20 Series Pump-priming Portable Gas Detector Operation Manual (Please read this introduction carefully before use and installation) (Rev 1.0) HENAN ZHIYI SYSTEM ENGINEERING CO., LTD.

Precautions Since some steps or improper operation, and ignore certain specific conditions may impair the performance of the instrument, for the safety and measure performance of the instrument, please strictly refer to the following instructions to operate and measurements. 1 Before use this instrument, please read carefully and total understand the content of this manual, strictly follow every stipulate of this manual. 2 Gas detector must be test and maintain by trained technical every three to six month, and write record. Only use Globeinstrument Instrument approved accessory when maintain. 3 The first use instrument must be charged fully, and by matched dedicated charger. 4 Since this instrument have build-in high capacity battery, so please don t test it in high temperature environment. 5 Please test performance before use it, if the instrument can not pass the performance test, can recalibration or restore factory calibration. 6 The vent of sensor must keep clean, Sensor vent blockage or dirt of water network cause reading lower than the actual concentration. 7 The change of atmosphere pressure may cause the reading suddenly change. 8 When detect combustible gas, the concentration of oxygen in air will affect the concentration of combustible gas. 9 This instrument operation temperature is -20-70,but the different sensor may cause operation temperature range reduce. 10 If there s some unusual condition when use it, please contact our technical support 86-0371-68988008. I Product Introduction PGAS-20 handheld pump gas detector is a alarm instrument, can continuous detect combustible gases, oxygen, or toxic gas concentrations and limit of the operating environment, is essential protective equipment for the production of industrial safety. 3.5-inch TFT LCD display, real-time observation of the target gas concentration,the concentration values color will change when the hight and lower two level alarm. It applies to toxic gas leak disaster, underground pipe or mines, industrial gas detection, power, petrochemicals, medical equipment, cold storage and furniture workplace environment and other places, can effectively ensure staff safety from abuse, production equipment from damage. With built-in air pump sampling methods, fast response, low noise. 1

II Function Feature Audio alarm Vision alarm USB communication Color LCD display Test record Alarm record Calibrate record For audio, prompt; there are two different frequency and duration for concentration alarms. Lower concentration:2hz Hight concentration:4hz Operate failure:4hz,ring 2 Operate success:1hz,ring 1 Status indicator:4hz,ring every 5 minutes In addition to the oxygen sensor, higher than the low concentration and less than high concentration produce the low concentration alarm, higher than the high concentration produce high concentration alarm. If there s lower concentration alarm in test status, the number of indicate concentration value display yellow, if have high concentration alarm will display red typeface. the icon in the status bar also displays alarm status. Instrument have USB communication port, will communicate with computer directly with 9600 byte speed. Equipped with a full-color 3.5-inch TFT screen, numeric display and graphics can be displayed simultaneously, so that the test is very intuitive. Instrument uses a high-capacity FLASH memory chips, will be able to store a month (in 30 seconds recording) measurement data, and you can view the data with the instrument, you can use a computer to view the data. Instrument will record recently 4 times alarm time and type. Instrument will record recently 4 times calibrate time and calibrate 2

Function menu range size. calibrate-zero calibrate-range calibrate-restore factory-adc value-calibrate period alarm-lower value alarm-high value alarm-twa-stel-alarm mode Parameter set-gas type-decimal-gas range-gas unit-cfc module (Only when the gas type is TVOC) System set-address-back light brightness-back light brightness-back light time-pump transfer set- turn off time-store alternation-language set Record check-history record-alarm record-calibrate record delete record-store capacity Time set-year-month-date-hour -minute-second Charge This Instrument use lithium battery supply power, since no full charge when out from factory, so need fully charge before use it, follow below steps 1. Plug USB cable 2. In start status see if the battery status icon is charge icon ;If in turn off status plug USB, then charge icon will illumine 3. It will take about 8 hours to charge full. In the top bar can see the icon of different battery,including percentage of remain battery. Audio will alarm when instrument battery is less then 2%, will turn off when 0%. III Basic operation Instrument turn on interface:instrument will read instrument parameter when turn on, if inner component operate normal, if the battery is normal. Turn off key will shield when turn on.take the VOC detector interface as the example. 3

Turn on interface Main interface 1 Time 8 High lower value alarm 2 The battery area 9 TWA,STEL alarm 3 Curve display area 10 Fault,error code 4 Gas type 11 Back light grade 5 Measure concentration 12 Alarm mode 6 CFC modulus 13 Pump speed 7 Gas unit Instrument in the normal state can not only display the concentration with digital but also display the concentration with curve. in the top bar shows the current real time, the current power, In the bottom bar has high and low values alarm icon, TWA, STEL icon, fault, error icon, backlight level icon, alarm mode icon, pump speed icon. These make the user real-time observe the running status of the instrument. Please know the function of every key before use it Long press power turn on or turn off, short press is return key function. Menu key:in test interface press menu key into menu set interface. Shortcut key:in test interface, press shortcut key into shortcut menu set. OK key Up key: add function and up move function 4

Down key:reduce and move down function Left key:shift function Right key:shift function In main menu press key will into menu main interface,alarm, store record, turn off function will be limited. Before into menu key except shortcut menu key and power key,other keys will be shielded and have no function, after go to menu key can press,,, into sub menu selection, after selected, press into operate. Instrument calibration: Non-professionals misuse, if misuse may cause tests result not precision; if calibration errors, please re-calibration, or restore the factory default, if still not solved, please return to the factory When select instrument calibration press,can do zero calibration, range calibration, restore factory default calibration, ADC value,calibrate interval set option, operating person can press, key to select sub menu, after selected, press, into operate. 5

Zero calibration:after selected zero calibration, press confirmation key to calibrate, also can press return key cancel this zero calibration.; Range calibration:after selected range calibration, press confirmation key to calibrate, at this time can press, key to add or reduce;press, key to shift to numbers set,after set, press confirmation key to finished calibration or press return key to cancel this calibration; Restore factory calibration : after selected restore factory calibration press confirmation key enter,or press return key cancel this operate.; Calibrate interval:this operation is to note every types of sensor calibration period, normally, according to factory identification is ok.,or press confirmation key to modify,at this time press, key to add or reduce;when finished set, press confirmation key to finish operation or press return key to cancel this operation; Alarm set When select alarm set, press to enter, can set lower value alarm, high value alarm,twa,stel alarm,alarm sound set, operating person can press, key to select sub menu, then press to operate. 6

Lower value alarm set:after selected lower value alarm press confirmation key to set,at this time can press, key to add or reduce;press, key to shift to number set,after set press confirmation key to finish operation or press return key to cancel this operation; High value alarm set:after select high value alarm, press confirmation key to enter set,at this time, can press, key to add or reduce;press, key to shift to number set,after set press confirmation key to finish the operation or press return key to cancel this operation; TWA alarm set: after select TWA alarm, press confirmation key to enter set,at this item, can press, key to add or reduce;press, key to shift to number set,after set press confirmation key to finish operation or press return key to cancel this operation; Note:first set high value alarm, then set lower value alarm,. Otherwise lower value alarm can t be set STEL alarm set:after selected STEL alarm press confirmation key to enter set,at this time can press, key to add or reduce;press, key to shift to number set,after set press confirmation key to finish operation or press return key to cancel this operation; Alarm sound set: after selected sound set, then press confirmation key to enter set,at this time to press, confirmation to select (ON) or(off),after set to press confirmation key to finish operation or press return key to cancel this operation; Parameter set After selected parameter set, then press to enter,can set gas type, decimal, gas range, gas unit.cfc(only when gas type is TVOC can set) operation person can press, key to select sub menu,after selected to press to enter operation. 7

Gas type set:after selected gas type, then press confirmation key to enter set, at this time, can press, ket to add or reduce;after set, press confirmation key to finish operation or press return key to cancel this operation; Decimal set:after select decimal, then press confirmation key to enter set,at this time, can press, key to add or reduce;after set, then press confirmation key to finish operation or press return key to cancel this operation; Unit set:after selected gas unit, then press confirmation key to enter set,at this time can press, key to add or reduce;after set, then press confirmation key to finish operation or press return key to cancel this operation; System set After selected system set, then press to enter,can set address, backlight brightness, backlight time,pump speed, turn off set,store time,language set Operating person can press, key to select sub menu,after select, then press to enter operate. 8

Address setting:after selected address, then press confirmation key to enter set,at this time, can press, key to add or reduce;press, key to shift to number set,after set, then press confirmation key to finish operation or press return key to cancel this operation;( address size is (1-255)) Backlight brightness setting : after selected backlight brightness, then press confirmation key to enter set,at this time can press, key to select (backlight only two grade);after set. Press confirmation key to finish operation or press return key to cancel this operation. Backlight time setting:after selected backlight time, then press confirmation key to enter setting,at this time, can press, key to select(backlight time unit is seconds); after set, press confirmation key to finish operation or press return key to cancel this operation. Pump speed setting after selected pump speed, press confirmation key to enter setting,at this time, press, key to select(pump speed only have three grade); after setting, press confirmation key to finish operation or press return key to cancel this operation. Off time setting:after selected off time, press confirmation key to enter setting, at this time, can press, key to select(off time unit is minutes); after set, press confirmation key to finish operation or press return key to cancel this operation. Store time setting:after selected store time, press confirmation key to enter setting,at this time, can press, key to select(store time unit is second); after set, press confirmation key to finish operation or press return key to cancel this operation. Language setting:after selected language, press confirmation key to enter setting,at this time, can press, key to select. after set, press confirmation key to finish operation or press return key to cancel this operation. Data Log When selected data log, then press to enter, can check data record, alarm record, calibration record, delete record, store capacity.operation person can press, key to select sub menu,then press enter operating check. 9

Data record check : select history, then press confirmation key to enter to check,at this item, can press, key to turn page to check every page twenty record; Alarm record check:after selected alarm record, press confirmation key to enter to check,alarm record only keep the latest four alarm record.. Calibration record check:after selected calibration record press confirmation key to enter to check,alarm record only keep the latest four calibration record. Delete record check:after select delete record, press confirmation key to enter to delete,also can press return key to cancel this operation; Memory status check: store capacity only check present the percent of store capacity in total capacity. Time & data After selected time setting, press to enter,can operate year,month, date, hour, minute, second. Operating person can press, key to select sub menu, then press enter to operate. 10

Year setting: after selected year setting, then press confirmation key to set, at this time, can press, key to select,;after setting, press confirmation key to finish operation or press return key cancel this operation; Month setting after select month, press confirmation key enter setting,at this time, press, key to select;after setting press confirmation key to finish operation or press return key cancel this operation; Day setting: after selected date setting, press confirmation key to enter setting, at this time,can press key to select;after setting, press confirmation key to finish operation or press return key to cancel this operation; Time setting:after selected time setting, press confirmation key to enter setting, then press, key to select;after setting, press confirmation key to finish operation or press return key to cancel this operation; Minute setting:after selected minute setting, press confirmation key to enter setting, then press, key to select; after setting, press confirmation key to finish operation or press return key to cancel operation; Second setting:selected second setting, press confirmation key to enter setting, then press, key to select; after setting, press confirmation key to finish operation or press return key to cancel operation; Appendix I: Fault Code Meaning (Fault)type Fault code Fault reason Introduction Step F1 The Re-start, still unusual, then mico-processor MCU running unusual return to factory to test fault F2 Store fault Store can t storage Return factory to test F3 Data invalid Date in storage is invalid Return factory to test F4 Analog circuit ADC input voltage over unusual normal range Return factory to test Can t read component F5 Out IC fault (including AD DA digit potential device clock digit humiture sensor etc) Return factory to test Can t read probe data or F6 Probe abnormal probe return abnormal Return factory to test report F7 F8 Communication abnormal Power voltage abnormal Communication with the host computer(like S485 wireless CAN)abnormal Power voltage too high, too lower or too volatile Check wire road and configure, still abnormal, then return factory to test Change power supply,still abnormal, then return 11

factory to test F9 Gas pump abnormal Open circuit or jam Check or clear gas pump Warning type Warn code Warn reason measure D1 Calibration interval expire Re-calibration D2 Calibration invalid or no calibration Re-calibration D3 Sensor life over Change new sensor D4 Measure gas overload Change large range sensor D5 Humiture over allowed range Stop working D6 Clock set invalid Re-set D7 Battery no power or power too lowe Change battery D8 Reserved D9 Reserved Operation error type Error code Error reason Introduction Measure E1 Input A1 value error Input A1 value A2 value A1 value E2 Input A2 value error Input A2 value>range value or A1 value Input A2 value again E3 Input range Input range value is 0 or> Re-input range value value error 50000 E4 Zero calibration Calibration ADC value 20 % Fill N2 zero calibration error max ADC value E5 Range calibration error Calibration ADC value 25 % max ADC value Change high concentration standard gas or sensor Input calibration point 25 % range or 120 % range Re-input calibration value E6 Input TWA error Input TWA value > STEL Re-input TWA value value E7 Input STEL Input STEL value<twa value Re-input TWA value error E8 Reserved E9 Reserved 12

Alarm Tips Alarm type Display Sound, light, vibration introduction Lower alarm Low or A1 Sound lith vibrate, 1HZ(interval 0.5s)continue High alarm High or A2 Sound light vibrate, 2HZ(interval 0.25s)continue TWA TWA Sound and light,every 10 second one time,every two short(two 0.25s interval 0.25s) STEL STEL Sound light,every 10 second one time,every time three short( three 0.25s interval two 0.25s) warn D1-D9 sound,light every 20 second one time,every time two long(two 0.5s interval 0.25s), fault F1-F9 sound,every five second one time, every time three long(three 0.5s interval two 0.25s); light always on error E1-E9 sound, every time long ring 0.5 second Lower voltage Low Voltage Sound,30 second ring one time, every time two short( two 0.25s interval 5s) Auto off Auto OFF Sound light,every two second one time, every time 0.5 second, total five times Normal off Power OFF Sound light, one time last two second Operation OK Sound light, one time last one done second Operation FAIL Sound light,two times short 0.25 failed second,interval 0.25 second button no sound,one time short 0.25 second Auto enter to save power mode Save successfully 13

Appendix II Common problems and solutions 1 Can not boot No battery Express Mail request battery can not be 2 In the air, the detector shows the concentration exceeds and instability. 1PPM, 3 Detection of gas no reaction 4 Exceeds the set alarm value No sound 5 Automatic shutdown 6 Reading instability No electricity Possible sensor loose, poor contact. Causes the internal void of the inputs of the circuit, voltage drift. Around the ventilation or air-conditioning system is not closed ventilation Surrounded by high-power interference sources Not the end of the warm-up Sensor is bad connection Sensor failure or circuit failure Check whether the alarm setting mode select full The buzzer does not work properly installed in the instrument, so the battery is removed in the box, install themselves. Charger to fully charge and then use the detector is recommended for the first time fully charged before use. Make sure the connection is normal between the sensor and the circuit board Please turn off Keep away from sources of interference instrument Preheat after the end of the measurement Reconnect sensor Contact our Repairs Check the alarm settings in the sound settings whether the to "ON" Returned for repair or replacement required Low battery Please charge re-use, power is less than 2% System settings off time is set too short Polarization not enough time Sensor failure Circuit fault Surrounded by sources of interference, such as high-power jamming equipment Airflow around the probe, pressure instability AC interference Clogged with dust or probe into of the audio alarm, automatic shutdown reaches 0% Prolonged shutdown time or set to automatically shut down 0m Continued polarization Replace sensor Back to the factory for repair Move the instrument without interference and keep the area free from vibration Holding steady flow and pressure The instrument power supply circuit access instrumentation, and keep well grounded Suction tube or chamber cleaning up dust the gas chamber inside (the latter requires Depot) NOTE: After equipment failure, please contact our service personnel, and then decide whether to return for repair. 14

The Users Guide is published by Henan Zhiyi System Engineering Co., Ltd. No prior notices will be given in case of any discrepancy between the contents herein and the actual products due to typographical errors or constant update and improvements of the products. Please visit www. Globeinstrument.com or contact the Company for the latest version. Henan Zhiyi System Engineering Co., Ltd. reserves the right for final interpretation. Henan Zhiyi System Engineering Co., Ltd. Tel.: +86-371-68988008 Fax: +86-371-56980200 Zip Code: 450001 Add.: No. 101,Yulan Str, Hi-new Tech Zone, Zhenzhou City Http://www.globeinstrument.com 15