High Volume Injection up to 5 ml with the Agilent 1200 Infinity Series Online SPE Solution for Highest Sensitivity

Similar documents
Enhancing Throughput of Online SPE Analysis of Pesticides in Wastewater The Agilent 1200 Infi nity Series Online SPE Solution

Application Note. The Agilent 1200 Infinity Series Online SPE Solution for the Highest Sensitivity. Author. Abstract.

Rapid Quantification of Polar and Semipolar Pesticide Metabolites with Combined Online SPE and Direct Injection

Application Note. Authors. Abstract

On-line SPE Enrichment of Trace Organic Contaminants in Water and Juices

Agilent InfinityLab Online SPE Solution

Analysis of Pharmaceuticals and Personal Care Products in Groundwater by Online SPE and LC/MS/MS

On Line SPE LC/MS/MS Applications

Direct Injection and Online SPE LC/MS/MS for the Determination of Pharmaceuticals and Personal Care Products (PPCPs) in Water Samples

An Advanced Heat Exchanger for the Agilent 1290 Infinity Thermostatted Column Compartment

Optimizing the Performance of the Agilent 1290 Infinity Evaporative Light Scattering Detector

Agilent 1290 Infinity II Online SPE Solution

Agilent 1290 Infinity II Vialsampler Data Sheet

Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples

Sensitive Determination of Microcystins from Environmental Waters Using On-Line SPE

AppNote 6/2008. Automated SPE and Fast GC-ECD Analysis of PCBs in Waste Oil KEYWORDS ABSTRACT INTRODUCTION. MACH, Fast GC-ECD, SPE, PCB, waste oil

DETERMINATION OF PAH In Particulate Matter PM 10 with SPE/EVAporation

AppNote 3/2009. Automation of Solid Phase Extraction Methods using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

Systems. Visit us at

FREESTYLE SPE UNIQUE POSSIBILITIES FOR SOLID PHASE EXTRACTION

300 series HPLC autosamplers

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Solid Phase Extraction using the 96-well Format ISOLUTE -96 Fixed Well Plates and ISOLUTE Array 96-well Plates

Automação de SPE utilizando sistema robótico Triplus RSH autosampler. Nova Analitica

Automated Sample Preparation: SPE GPC - EVAporation SUPERIORITY BY ADAPTATION. Visit us at

IMPROVING THE QUANTITATIVE REPRODUCIBILITY OF AN ATMOSPHERIC PRESSURE CHEMICAL IONISATION SOURCE FOR GC/MS AND GC MS/MS ANALYSIS

Thermo Scientific Dionex AutoTrace 280 SPE Instrument. Automate Large-Volume. Solid-Phase Extractions

This document is a preview generated by EVS

DETERMINATION OF PAH In Particulate Matter PM10 With SPE/EVAporation

Agricultural. drugs of abuse. Food & Beverage. Pesticides SOLID PHASE EXTRACTION. Inject. Wash Elute. Cartridges. Concentrate. Silica.

APPLICATION NOTE DETERMINATION OF THE HYDROCARBON-INDEX DIN EN ISO :2000. APPLICATION NOTE As of July 2017, Version: 1.

Online SPE-UHPLC-MS. CHRONOS for Control & System Integration. Flexible autosampler for sample preparation. Superior UHPLC system for analysis

The Complete and Easy Guide to Configuring Your Specific Thermo NanoLC for Mass Spec Analysis

Auto SPE-06Plus Solid Phase Extraction System. Reeko Instrument USA

InfinityLab Quick-Connect Bio-inert Heat Exchanger

Spark Holland introduces

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

Tool-free LC connections for HPLC, UHPLC and nano LC systems

detectors UltiMate 3000 Variable Wavelength Detectors

Thermo Scientific Rocket Evaporator. Revolutionary solvent evaporation complete laboratory workflow

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

JSB is an authorised partner of DETERMINATION OF THE HYDROCARBON-INDEX DIN EN ISO :2000. i n s p i r a t i o n m e e t s i n n o v a t i o n!

Customised HPLC Systems for Highest Performance

Improved HPLC Separations at Elevated Temperatures Using a New Stand-alone Preheater

Customers should provide all necessary operating supplies upon request of the engineer.

TYPES AND APPROPRIATE INJECTORS

An Automated SPE Procedure and Analysis for the Extraction of Chlorpromazine and Thioridazine from Plasma Application Note 213

CALIDUS tm the Modular micro Gas Chromatograph

GC Injectors. GC Injectors

DYE QUALITY CONTROL REFERENCE MATERIAL KIT

Nexera-i Specifications Prominence-i Specifications

Purge and Trap Troubleshooting Made Easy?

FIXED GAS ANALYZER (FGA)

How Important is Performance to your SPE Method Development?

Agilent Vac Elut SPS 24 Manifold User Guide

Agilent 1290 Infinity II LC

Order all the parts and accessories needed at one time Reduced learning curve for rapid implementation

SEC-MALS Noise Assessment and Cleaning Guide

MultiPurpose Sampler MPS robotic series

Agilent 1100 Series Refractive Index Detector. Reference Manual

API 2000 LC/MS/MS TurboIonSpray Ion Source Manual

FREESTYLE always ready

XENOSEP. SPE Systems for EPA Method 1664A. The Easiest, Most Cost Effective Way to Increase Productivity

SCION 436-GC. Dimensions and Weights

Agilent 1200 Series Variable Wavelength Detector

Perkin Elmer Clarus 500 Gas Chromatograph

Injection/Trapping. Analysis

get mass. without massive work. [ 3100 MASS DETECTOR ]

Q Trap LC/MS/MS TurboIonSpray Ion Source Manual. About This Manual... 1 Conventions Introduction... 3 Features... 4

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

Training Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.

Agilent 6400 Series. Maintenance Guide. Agilent Technologies

Fundamentals of Solid-Phase Extraction (SPE): Principles and Practical Tips for Developing Sample Preparation Methods

Installation of Hotel Drawers

Tubing spares and piping accessories. Gas purification and control 1 Moisture Traps,Carbon traps 2 Gas Purification Panels 3 Gas Control Box

The Road to Recovery. Mapping Advanced Sample Preparation Techniques for GC, GC-MS and HPLC Analysis

Product Guide for Ludger Clean Post-endoglycosidase and Post-exoglycosidase Clean-up Plate

Gagnez avec «David» Mighty MEPS contre les cartouches «Goliath» SPE

Automated Fractionation System that Increases Recovery and Optimize Precision of Solid Phase Extraction Methodology

HPLC Column Ovens and Temperature Controllers

HITACHI CHROMASTER. Clarity Control Module. Code/Rev.: M173/70I Date: 6/23/2018

Evaporators, Sealers and other Equipment

Installing the Agilent CE ESI-MS Sprayer Kit (G1607A)

An Introduction to Mass Spectrometry

WELCOME TO ELLUTIA CHROMATOGRAPHY SOLUTIONS

Agilent 1200 Series Diode Array and Multiple Wavelength Detectors

RapidTrace + Automated SPE Workstation. Instruments. Accessories Racks Vial Adapters Test Tubes O-Rings Miscellaneous

Use of Automation to Achieve

Advancing the power of SPE. Intelligent Automated Solid Phase Extraction. SmartPrep Brochure

Supra-Clean and Supra-Poly SPE Solutions. Solid Phase Extraction Columns

SystemsQT for Waters Alliance HPLC Systems (Revision G)

LABTRON LAAS - Series Atomic Absorption Spectrophotometer

Chromatography. Research Supplies. 2014/2015 Catalog

Agilent GC Sampler 80/120 SPME Option

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System

Methods of solid phase extraction. Methods of solid phase extraction

Technical specifications of FT-IR Spectrometer

BenchTOF. The next generation of time-of-flight mass spectrometers for GC and GC GC

PRODUCT CONFORMITY CERTIFICATE

Transcription:

High Volume Injection up to ml with the Agilent 00 Infinity Series Online SPE Solution for Highest Sensitivity Technical Overview Author Bettina Schuhn Agilent Technologies, Inc. Waldbronn, Germany Abstract The Agilent 60 Infi nity Standard Autosampler is recommended in the Agilent 00 Infi nity Series Online SPE Solution because it offers enhanced injection volume capabilities. High volumes are needed for highly sensitive measurements, like pesticides in water. With the 900 µl injection upgrade kit and the multi-draw upgrade kit, up to,800 µl can be injected. This Technical Note describes an additional high volume injection kit with a -ml sample loop and presents data supporting the precision of peak area and linearity. The -ml sample loop is connected to an external -position/6-port valve, which makes it possible to switch the sample loop out of the fl ow path to run normal HPLC methods in direct inject mode without the delay volume of the external loop.

Introduction To increase the injection volume of the 60 Infinity Standard Autosampler, a 900-µL analytical head and a,00-µl seat capillary can be added. This expands the injection volume to a maximum of,800 µl. However, for some online SPE methods and low compound concentrations, larger injection volumes are required to increase the sensitivity of the system and to achieve detection limits in the low ng/l range for applications such as drinking, environmental, and wastewaters. Levels below ng/l can be detected with the help of an external valve drive and a -ml sample loop. The sample is concentrated on the trapping column and the analytes are backflushed onto the analytical column. Using the solvent selection valve, the sample loop and trapping columns are flushed with up to three solvents with the 90 Infinity Flexible Cube. Experimental and Instrumentation All experiments were performed on an Agilent 00 Infinity Online SPE Solution comprising: Agilent 60 Infinity Binary Pump (p/n GB) and LAN card (p/n G69C) Agilent 60 Infinity Standard Autosampler (p/n G9B) with 900-µL head (p/n G-6000) and an Agilent 90 Infinity Thermostat (p/n G0B) Agilent 90 Infinity Flexible Cube (p/n GA) with two -position/0-port valves Agilent 00 Infinity Online SPE starter kit: (p/n GA) (one -position/0-port valve, 600 bar) Agilent 00 Infinity Online SPE direct injection kit: (p/n GA) (one -position/0-port valve, 600 bar) External valve drive (p/n G0A) with -position/6-port valve (p/n GA) and a -ml loop (p/n G60-68) Agilent 90 Infinity Thermostated Column Compartment (p/n G6C) Trapping columns Two Guard Column Hardware Kits (p/n 80999-90) (as part of GA) PLRP-S Cartridges,.. mm, 0 µm (p/n 98-) (as part of GA) 6-mL screw cap vials (glass p/n 90-, screw caps p/n 90-9, pre-slit septa p/n 88-8) Software Agilent MassHunter Data Acquisition for Triple Quadruple Mass Spectrometer, Version 06.00 Agilent MassHunter Optimizer software, Version 06.00 Agilent MassHunter Source and ifunnel Optimizer software, Version 06.00 Agilent MassHunter qualitative software, Version 06.00 Agilent MassHunter quantitative software, Version 0.0 Agilent Triple Quadrupole LC/MS System with Agilent Jet Stream Technology (p/n G660A)

System configuration and principle of operation The configuration of the system is based on the Agilent 00 Infinity Series Online SPE Solution. This includes the 90 Infinity Flexible Cube, which hosts two -position/0-port valves for direct injection and online SPE methods on the same instrument. To upgrade the instrument for high volume injection with up to ml, an additional external valve drive can be installed (G0A) at the 90 Infinity Flexible Cube (Figures and ). The external valve hosts a -pos/6-port valve to switch the sample loop in or out of the flow path. The sample loop is placed in the flow path between the needle seat capillary and the injection valve (port ) of the autosampler. Figure shows the valve setup with two -position/0-port valves and one -position/6-port valve, which hosts the -ml loop on the external drive. After the loading process, the external loop is flushed with the 90 Flexible Cube. If lower injection volumes are sufficient, the external loop can be easily bypassed due to the -position/6-port valve on the external drive (Figure ). Valve Drive -ml Loop Flexible Cube Binary Pump 6 Flexible Cube Solvent selection valve Flush pump Needle Seat Waste Sample Loop Standard Autosampler (900 µl Head) Metering Device SPE (Elute) Analytical column SPE (Load) Waste Figure. The Agilent 90 Infinity Flexible Cube with two -position/0-port valves, the autosampler configuration, and the external valve drive with the -ml loop. The sample is drawn and ejected with the autosampler into the external loop. After the ejection, the 90 Infinity Flexible Cube loads the samples from the loop to one of the trapping columns (see flow path). Valve Drive 6 Needle Seat 6 Waste 6 6 0 9 8 Sample Loop Metering Device 0 6 Standard Autosampler (900 µl Head) 9 8 -ml Loop Flexible Cube Flexible Cube Binary Pump Solvent selection valve 0 9 8 SPE (Load) 0 9 8 Flush pump 6 6 SPE (Elute) Analytical column Waste Figure. The -ml loop can be easily disabled if the position of the -position/6-port valve is changed. Hence, additional dead volume is saved.

Finally, the system is coupled to an Agilent 660 triple quadrupole mass spectrometer. The online SPE procedure consists of three steps (Figure ):. Loading and enriching the sample on the SPE cartridge (SPE ). Elution of SPE with the gradient flow. Rinsing and reconditioning SPE (from the previous run) Samples Tap water was spiked with an equimolar mixture of five pesticides (carbofuran, dimethoate, imazalil, metazachlor, metosulam) with 0 ng/l. Six consecutive runs were performed for every injection volume. Chemicals All solvents used were LC/MS grade. Acetonitrile was purchased from Merck, Germany. Fresh ultrapure water was obtained from a Milli-Q Integral system equipped with LC-Pak Polisher and a 0.-μm membrane point-of-use cartridge (Millipak). Formic acid was purchased from Agilent Technologies (p/n G-8060). Agilent 60 Infinity Binary Pump gradient Agilent 90 Infinity Flexible Cube and -ml Loop 0 % B Step Loading SPE with sample and ml of Solvent A Right valve switches (0.6 minutes) Step % 00 % B Figure. Schematic of the online SPE method, which includes the Agilent 90 Infinity Flexible Cube as a loading pump and an Agilent 60 Infinity Binary Pump to run the gradient. Method 60 Infinity Binary Pump Solvent A water, 0.% formic acid Solvent B 9% acetonitrile, 0.% formic acid Flow rate 0. ml/min Gradient Time (min) % B 0 0. 6. 00 8. 00 Post time 8 minutes 90 Infinity Thermostatted Column Compartment Temperature 0 C Column Agilent ZORBAX Eclipse Plus C8,. 0 mm,. μm (p/n 996-90) 90 Infinity Flexible Cube Pump. ml/min Solvent selection valve Solvent A: Water, Solvent A: Acetonitrile 60 Infinity Autosampler Draw and eject speed 900 µl/min % B Step SPE is in front of analytical column and Post time eluting SPE while SPE is rinsed with A ( ml) and A (6 ml) 0. 8. 6. Time (min)

Results and Discussion Performance characteristics precision of peak area Seven different injection volumes (,.,,,,, and 0. ml, n = 6) were analyzed and the relative standard deviation (RSD) of the peak areas were calculated. Figure shows the RSD values for different injection volumes and compounds. The chemical properties of the analytes have a huge impact on the linearity and precision. As it can be seen in Figure, the most nonpolar and latest eluting compound, matazachlor, has area RSD values of less than % for all injection volumes. In comparison, the first eluting compound, dimethoate, has the highest area RSD values in this set of compounds (0..6 %). For all compounds and injection volumes the area RSD was < %. Performance characteristics linearity Analysis of samples with different injection volumes but the same compound concentrations gives the linearity of the system coupled to the external sample loop. The calibration curves were developed for seven levels, at the same sample concentrations, and the linearity is illustrated by the correlation coefficients listed in Table. The linearity of the analyte is dependent upon its chemical characteristics, its ability to bind to the trapping column, and the performance of the autosampler coupled to the external loop. Area RSD (%) 0.00 8.00 Matazachlor 6.00 Metosulam.00 Carbofuran.00 Imazalil 0.00 Dimethoate 00,000,000,000 Injection volume (µl),000,00,000 Figure. Area RSD and its correlation to the injection volume (area RSDs for all compounds < %). Table. Compounds and their correlation coefficient and retention times. Compound Coefficient of determination (R ) Retention time (min) dimethoate 0.99.8 imazalil 0.990. carbofuran 0.99.8 metosulam 0.9. matazachlor 0.99.

Figure shows the correlation of peak area and injection volume for two pesticides. Regarding the peak area, it can be observed that matazachlor has, compared to the other analytes, the best characteristic to bind on the trapping columns. In addition, the peak area and sensitivity increases steadily to an injection volume of,00 µl. Between,00 and,000 µl, the peak area remains constant. The same behavior can be seen for all other compounds. This is a well-known behavior of fixed-loop injectors. When filling the loop to more than 0 % of the loop volume, some of the sample is already flushed out the other end of the loop due to the parabolic flow profile. Therefore, it is recommended not to fill the loop more than. ml. Tip The injector program can be optimized to save time during the autosampler multidraw process. The autosampler needs time to draw the sample from the vial and eject it into the loop. Therefore, it is more efficient to draw 900 µl in the last step of the injector program, because this volume does not have to be injected into the loop again (Figure 6). Another advantage of this injector program is that the 900 µl, which is drawn in the last step, will not be ejected in the loop. This minimizes the effect of the parabolic flow profile, since the loop is filled with less volume. During method optimization, it was determined that at least one loop volume of solvent A (water) in the 90 Infinity Flexible Cube should be used to transfer the sample from the sample loop to the SPE cartridge. However, the best performance and reproducibility was achieved when the sample loop was flushed three times ( ml) to transfer the sample to the cartridge. Peak area Peak area 0 6 A 6 0 0 0 0 00 B Matazachlor,000,000,000,000,00,000 Injection volume (µl) Carbofuran 00,000,000,000,000,00,000 Injection volume (µl) Figure. Correlation of the peak area and the injection volume of matazachlor and carbofuran (n = 6). Figure 6. Screenshot of injector program for -ml injection volume. 6

Conclusion This Technical Overview shows the precision and linearity of the Agilent 00 Infinity Series Online SPE Solution with a high volume injection kit, consisting of an external valve drive with a -ml sample loop. It was demonstrated that the -ml sample loop can be easily integrated in the 00 Infinity Series Online SPE Solution and achieves precise and reliable injection volumes between 00 and,00 µl. References. Installation Note for Multidraw Upgrade Kit G-68, Agilent Technologies, Installation Note, Publication Number G-90, 006.. R. López-Serna, S. Pérez, A. Ginebreda, M. Petrovic, D. Barceló, Fully automated determination of pharmaceuticals in environmental and waste waters by online solid phase extraction liquid chromatographyelectrospray tandem mass spectrometry, Talanta 8, 0, 00.. E. Naegele, Comparison of Direct Injection and Online SPE for Quantification by LC/MS of Trace- Level Herbicides in Water, Agilent Technologies, Application Note, Publication Number 99-0EN, 0.

www.agilent.com/chem This information is subject to change without notice. Agilent Technologies, Inc., 0 Published in the USA, October, 0 99-EN