PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

Similar documents
PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

PolyGard 2-channel Gas Controller MGC-03

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

Carbon Monoxide CO Transmitter ADT-X3-1110

Combustible Gas Detection and Control System

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Two-Channel Gas Controller

User Manual. PolyGard AT-3300 V3. Transmitter for Combustible Gases. Serial No. ET April 2009

User Manual. PolyGard Single Point Controller SPC Single Point Gas Controller for Combustible Gases Serial Number _E_1008.

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

User Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007

Multi-Gas-Controller MGC2

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Oxygen (O2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Gas Controller Module GC-06

Danfoss gas detection units

User Manual. PolyGard Single Point Controller SPC3-11XX. Single Point Gas Controller Serial Number _E_1007. May 2009

User Manual. PolyGard Single Point Controller SPC-43-20XX. Single Point Gas Controller for Refrigerant Gases Serial Number _E_.

APPLICATION DATA SHEET

Sensor unit MC2 with analog output for Freon gases and refrigerants

Danfoss gas detection Controller unit

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Danfoss gas detection units

Installation and Wiring 1.

Nitrogen Dioxide Stand-Alone Detector - Analog, ModBus

Dräger PEX 3000 Flammable Gas Detection

ESD500. ESD500 Combustible / Toxic Gas Detector

PRODUCT CATALOG 2016 PT. Victoria Globalindo Teknik PT. Victoria Agfasindo

ESD3000 ESD200 Combustible / Toxic Gas Detector

Danfoss gas detection unit Type GD Heavy Duty

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

ESD3000IR ESD3000IR. Infrared Gas Detector

MICROpeL 75 Combustible Gas Sensor Part Number: PM

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Installation & User Manual

Dräger Polytron 5700 IR Detection of flammable gases and vapours

User Manual. PolyGard CO LC-1112 V3. Electrochemical analog carbon monoxide transmitters serial no. EC-S 002. August 29, 2006

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

Model C Combustible Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

Model D12-IR. Digital Gas Transmitter...

Dräger Polytron SE Ex Fixed Gas Detector

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

GAS PLUS ALARM SYSTEM

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

Inc Series Digital Gas Detector/Controller. Operation Manual

Dräger Polytron 8700 IR Detection of flammable gases and vapors

CC28. Operation Manual. Transmitter for flammable gases and vapours

CMF, CMX & CMA series

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

02/11/2015

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

PolyGard Controller LGC/LG2-04. Multi-Point Controller Serial Number S00 User Manual Preliminary Version. August 11, 2006

02/11/2015

Toxic Gas Detection. Model F12. Toxic Gas Detection

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Dräger Polytron 8700 IR Detection of flammable gases and vapors

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Remote alarm indicator and test combination MK2430

Products and performance

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR

Dräger PIR 3000 Detection of flammable gases and vapours

Model D12. Digital Gas Transmitter

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

MODEL: Q8 SERIES NON-INTRUSIVE CALIBRATION GAS TRANSMITTER/SENSOR

S5000 Gas Monitor. GMS5000.com

GMA101. Operation Manual. Worldwide Supplier of Gas Detection Solutions

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

GS100M Gas Detection Controller

ALTAIR 5X Multigas Detector Product Specification

Version Inc Series Digital Gas Detector/Controller. Operation Manual

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Xgard. Fixed detectors For flammable, toxic or oxygen gases

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

SP-220. Features. Combustible handheld gas leakage detector

Process Alarm Module RTA 421

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

QAS SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR

Dräger Polytron 5100 EC Detection of toxic gases and vapors

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Electron Microscopy Sciences

Dräger REGARD -1 Control System

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Analog Room Pressure Monitor RPC Series

Catalytic Bead DrägerSensors for Fixed Gas Detectors

Detection, Protection, Innovation

Recalibrate the way you look at gas detection

GAS DETECTION SYSTEMS

Warranty Registration

Transcription:

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases DESCRIPTION Gas measuring and monitoring controller based on stateof-the-art microtechnology with integrated sensor for continuous monitoring of the ambient air and detecting toxic gases and vapours. As an option the SPC-X3-34XX is provided with an input for one external analog transmitter. 4 alarm thresholds per sensor/transmitter are free programmable. Configuration and operation are possible via the logical, simple system menu structure without specific programming knowledge. APPLICATION The SPC-X3-34XX is suitable for a wide range of industrial and commercial applications. Free programmable parameters and setpoints enable the individual adaptation to a variety of applications in the field of gas measuring and monitoring. Standard enclosure FEATURES Continuous monitoring Integrated gas sensor Good resistance to poisoning Long life expectancy Modular design (plug-in technology) Standard version with display/led/keyboard Comfortable calibration and maintenance Reverse polarity protected Overload-proof and short-circuit-proof (0) 4 20 ma / (0) 2 10V analog signal output 2 x relay outputs / 1 binary output IP 65 version Different housing versions 230 VAC power supply incl. 2 power relays in conjunction with POW-03 module (option) 230 VAC / power supply unit (option) Uninterruptible emergency power supply (option) 4 20 ma input for external transmitter (option) Integrated buzzer with reset function internal/external (option) Serial interface (option) Service tool for versions without display/led/keyboard (option) Manual calibration via potentiometers (option) Heating (option) Duct mounting (option) only without display/led/keyboard MSR Electronic GmbH Würdingerstr. 27a 94060 Pocking GERMANY 1 Jan 09

SPECIFICATIONS Electrical Power supply 18-28 VDC/AC, reverse polarity protected Power consumption (without options) 130 ma, max. (2,5 VA) Analog output, current or voltage selectable 0 (4) 20 ma, load 500 Ω 0 (2) 10 V, load 50 kω overload-proof and short-circuit-proof Alarm relay (1) 30 VAC/DC 0,5 A, potential-free, SPDT Alarm relay (1) 30 VAC/DC 0,5 A, potential-free, SPNO/SPNC Binary output 3 /0,1 A open collector Visualisation Display Two lines, 16 characters each Status LED (4) Normal operation- Fault- Alarm1- Alarm 2 Operation 4 push-buttons menu-driven Sensor performance Gas type Combustible gases/ vapours (see order inform.) Sensor element Ex sensor, catalytic bead (pellistor) Measuring range 0-100% LEL Accuracy ± 1 % of reading Long-term zero point drift < ± 6 % measuring range /year Long-term sensitivity drift < ± 1,5 % measuring range / month Response time t 50 3 s; t 90 10 s /methane Sensor life expectancy 3 years/normal operating environment Temperature range - 20 C to + 50 C (-4 F to 122 F) Temperature drift 1% Storage period Max. 6 months Mounting height Depending on gas type External transmitter Toxic gases, Ex gases, Freons, temperature, humidity, pressure, etc. Operating environment Humidity 15 95 % RH non-condensing Working temperature -10 C to + 50 C (14 F to 122 F) Storage temperature 5 C to 30 C (86 F to 122 F) Pressure range Atmospheric ± 10 % Physical Enclosure Plastic Type C* Polycarbonate Flammability UL 94 V2 Enclosure color* RAL 7032 (light grey) Dimensions (W x H x D) 130 x 130 x 75 mm (5.12 x 5.12 x 2.95 inch.) Weight Approx. 0.6 kg (1.323 Ibs.) Protection class IP 65 Installation Wall mounting Cable entry Standard 6 x M 20 Wire connection Screw type terminal, min. 0.25 mm 2 (24 AWG) max. 2.5 mm 2 (14 AWG) MSR Electronic GmbH Würdingerstr. 27a 94060 Pocking GERMANY 2 Jan 09

Guidelines Warranty Options Analog input Voltage for ext. analog transmitter Buzzer Acoustic pressure Frequency Serial interface Transceiver Heating Temperature controlled Ambient temperature Power supply Power consumption EMC Directives 2004 / 108 / EEC CE 1 year on material (without sensor) 4 20 ma overload-proof and short-circuitproof, input resistance 200 Ω max. load 50 ma 83 db (A) (distance 200 mm) (0.6 ft.) 2300 Hz RS 485 / 19200 Baud 3 C ±2 C (37,5 F ± 35.5 F) - 40 C (- 40 F) 18-28 VDC/AC 0,5 A; 12 VA MSR Electronic GmbH Würdingerstr. 27a 94060 Pocking GERMANY 3 Jan 09

ORDERING INFORMATION SPC-X3-34XX X XXXXXXXXX X1XXXXXXX XX1XXXXXX XXXX1XXXX XXXXX1XXX XXXXX2XXX XXXXXX1XX XXXXXXX1X XXXXXXXX0 XXXXXXXX1 XXXXXXXX2 XXXXXXXX3 XXXXXXXX4 XXXXXXXX5 XXXXXXXX6 Version Buzzer integrated Heating Serial interface Display/LED/keyboard (standard) Manual calibration 4 20 ma analog input Factory calibration 0 100% LEL. Menu language German Menu language English Menu language USA Menu language Dutch Menu language Danish Menu language Czech Menu language French Enclosure C Plastic (standard) 1 Duct mounting 1 4 IP 65 protection 1 5 Stainless steel 7 Plastic (comfort) Gas types 00 Methane CH 4 08 Ammonia NH 3 10 Ethylene C 2 H 4 25 Ethyl alcohol C 2 H 5 OH 27 Ethyl acetate CH 3 COOC 2 H 5 30 Benzene C 6 H 6 35 n-hexane C 6 H 14 40 Hydrogen H 2 45 Iso propanol alcohol (CH 3 ) 2 CHOH 50 Methanol CH 3 OH 58 Methyl ethyl ketone C 4 H 8 O 60 n-butane C 4 H 10 70 n-octane C 8 H1 8 75 n-pentane C 5 H 12 80 Propane C 3 H 6 85 Acetone (CH 3 ) 2 CO 90 Toluene C 7 H 8 91 n-heptane C 7 H 16 98 JP8 1 See data sheet PolyGard AT/DT Enclosures Example: Single Point Controller SPC-X3 for methane, stainless steel housing, buzzer, incl. factory calibration 0-100 % LEL, menu language English Order No.: SPC-X3-3400-5-X1XXXXX11 MSR Electronic GmbH Würdingerstr. 27a 94060 Pocking GERMANY 4 Jan 09

CONNECTING DIAGRAM Power Unit 4-20 ma AT-02/03 Option ext. Transmitter 7 6 5 4 3 2 1 X4 Bus_B Bus_A 4-20 ma_inp 4-20 ma_out SPC-X3 R2 R1 X5 1 DIO 2 3 Option 4 ext. Buzzer 5 ----- 6 NO 7 NC 8 COM 9 COM 10 NO/NC 11 ----- MSR Electronic GmbH Würdingerstr. 27a 94060 Pocking GERMANY 5 Jan 09