APPLICATION DATA SHEET S p e c i f i c a t i o n 2 SO22 WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700+ D e t e c t o r Website: C o n t r o l P a n e l - Wall mounting or 19 Rack Versions - 24V DC or 110/230vAC operation - 24V Independent Audio/Visual Alarm driver - Volt free contact outputs - Digital display showing gas concentration - ly addressable detector options - Battery backup options - Optional additional input/output cards - Easy installation - Modbus Output Option Power Source 85 to 264 VAC ( 18 to 30 VDC Option) Power Consumption 60 Watts (basic) 150 Watts (700+) Display 2 x 16 backlight LCD Operating Temperature 0 c to 55 c Operating Humidity Up to 95% non-condensing Resolution 0.00% or ppm Range Dependant Update Rate 1 Second Size (mm) 255 (H) x 265 (W) x 100 (D) Protection Standard IP54. With seal kit option fitted IP55 Inputs Up to 4 or up to 8 x 4-20mA loops Inputs (Optional) Additional 8 analogue 4-20mA loops 2 x RS485 data highways for up to 64 detectors (700+) Outputs (Standard) 3 x configurable SP relays (5 Amp non conductive load) 1 x fault SP relays (5 Amp non conductive load) 1 x solid state audio/sounder 24VDC 1 x solid state visual/flasher 24VDC Outputs (Optional) Up To 32 x configurable SP relays 5 Amp non inductive load Up To 16 x Analogue Outputs (4 per additional card) Up To 32 x Addressable Relay Outputs Optional Equipment Battery backup module 7AH 255 (H) x 265 (W) x 100 (D) CE Declaration BS EN61000-6-4 EMC Compatibility 'Emissions' BS EN 61000-6-2:2001 EMC Compatibility 'Immunity' BS EN 61010-1: 2001 Safety requirements, electrical equipment Weight 4.6 KG The Tocsin 700 provides ultimate system flexibility for small gas detection systems up to 64 detectors in size The Tocsin 700 control panel is compatible with all the Tocsin range of Toxic Flammable and Oxygen detectors and transmitters Additionally the Tocsin 700 detector control panel can be configured to accept inputs from industry standard smoke and heat detectors To compliment the system a range of accessories calibration sets and audio visual alarms are available S e n s o r s O p t i o n s F o r Flammable Gases Carbon Dioxide Carbon Monoxide Nitric Oxide Nitrogen Dioxide Hydrogen Cyanide Chlorine Hydrogen Sulphide Ammonia Oxygen Sulphur Dioxide Hydrogen Chloride Smoke Detectors Heat Detectors
D e t e c t o r C o n t r o l P a n e l D e t e c t o r O p t i o n s Ltd, 4a Pepper Rd DO T OPEN Ltd, 4a Pepper Rd Ltd, 4a Pepper Rd Ltd, 4a Pepper Rd DO T OPEN Ltd, 4a Pepper Rd For non hazardous area use Tocsin 103 series detectors are available as both 4-20mA analogue or RS485 addressable units. For further information refer to the Tocsin 103 and Tocsin 102 series detector data sheets. 700 Up To 32 Sensors on One addressable Loop Tocsin 102A Flammable Infra-Red Tocsin 102A Flammable Pellistor Tocsin 102A Toxic Gases or Oxygen Any Tocsin 102 Available with Tocsin 903 Local Display/Controller Using 4-20mA Process Output to Tocsin 700 Control Panel. Pellistors for wide application flammable gas detection, Infra Red detectors for 2 and targeted flammable gases. Electrochemical detectors for toxic gases and Oxygen detection. Notes: Tocsin 102 or 103 Series detectors either 2 or 3 wire 4-20mA output. Basic Tocsin 700 is supplied with 60W PSU and can accommodate up to 16 Analogue Detectors. The Tocsin 700+ is supplied with a 150W PSU and can accommodate up to 64 detectors a mix of analogue and addressable types. Note that the maximum number of analogue detectors is 16. SMOKE HEAT SMOKE Industry standard smoke and heat detector inputs. Up to 32 sensors per zone. Max 8 zones. Battery backup and additional I/O modules require additional accessory housings. 2 SO22 Website:
D e t e c t o r C o n t r o l P a n e l I / O O p t i o n s S t a n d a r d P a n e l I / O Basic Panel Equipped With 3 Assignable Relay Outputs Dedicated System fault O/P (Normally Energised) 700 Independent Audio and Visual Alarm Outputs 1 Amp Capability @24V DC O p t i o n a l I / O M o d u l e s Battery Backup Module P/N 5111401 Internal Sounder Option P/N 5133201 In Out In Out In Out In Out In Out 8 Channel Analogue 4-20mA Input Card. Converts Base Unit To Handle Up To 16 Detectors 8 Channel Relay P/N 5111001 8 Channel Relay P/N 5111001 Volt Free Contacts SP x 8 4 Channel 4-20mA Analogue P/N 5074601 4 Channel 4-20mA Analogue P/N 5074601 P/N 5133001 N o t e s Max 4 Additional Relay s Max 4 Additional Analogue s Additional I/O Modules can be supplied pre installed into the Tocsin 700 Accessory case ready mounted to the Tocsin 700 control panel or separately to allow for inclusion into custom panel builds. Please contact the sales office for further details. 2 SO22 Website:
P o s s i b l e S y s t e m C o n f i g u r a t i o n s Ltd, 4a Pepper Rd Ltd, 4a Pepper Rd Ltd, 4a Pepper Rd Ltd, 4a Pepper Rd Ltd, 4a Pepper Rd Ltd, 4a Pepper Rd OP1 RS232 Comms Link To Host Systems, SCADA, BMS etc OP2 OP3 OP4 SYSTEM FAULT SERVICE LABEL 3 Volt Free Relay Contact Outputs As Standard Expandable To 48 Outputs Audio Visual Units Available 700 Relay Output Nodes For Local Alarm or Control Up to 32 Detectors Flammable or Toxic Gases Per Loop 110/230 VAC 0r 24V DC Power Options Battery Back Up Units Available Connect RS485 Ports to Act as a Host For Another Tocsin 700 Series Control Panel. See the Same Detectors Connected to The Tocsin 700 on The Mimic Tocsin 700 Compatible With Tocsin 103, 102 or 903 Series Detectors. 8 off RS485 Ports. 700 OP1 OP2 OP3 OP4 SYSTEM FAULT SERVICE LABEL 2 Combine 4-20mA Analogue Detectors on the Same System as Addressable Detectors. Max 16 Analogue Inputs ATEX,safe Area or smoke and heat (32 per input). BOOSTER Power Boosters To Cater For Long Cable Runs ATEX or Safe Area Detectors Any Mix of Detectors, Flammable, Toxic, Oxygen and Relay Outputs 2 SO22 Website:
D e t e c t o r C o n t r o l P a n e l O p t i o n s S t a n d a r d To c s i n 7 0 0 I P 5 4 / 5 5 265 108 100 270 250 255 210 To c s i n 7 0 0 I P 5 4 / 5 5 W i t h A c c e s s o r y C a s e o r B a t t e r y B a c k u p 533 108 100 475 To c s i n 7 0 0 I P 5 4 / 5 5 W i t h A c c e s s o r y C a s e a n d B a t t e r y B a c k u p 108 801 100 268 475 Accessory cases can be added to the Tocsin 700 main panel to house either battery backup modules or additional I/O cards (relays, analogue inputs or outputs). Accessory cases are factory fitted items and should be specified when ordering. 2 SO22 Website:
D e t e c t o r C o n t r o l P a n e l O p t i o n s To c s i n 7 0 0 I P 6 6 V e r s i o n 280 260 125 230 180 Tocsin 700 Wall Mount Systems Sealed to IP66 Single Case Version Only 8 Analogue Channels and/or up to 64 Addressable Detectors To c s i n 7 0 0 1 9 " R a c k M o u n t V e r s i o n 485 TOCSIN 700R 133 AL 3 AL 2 AL 1 FAULT DETECTED POWER ADVANCED ADDRESSABLE GAS DETECTION SYSTEM TOCSIN 700 SERIES NTROLLERS 19 Rack Mount Format Tocsin 700 Systems. Industry Standard 3U High 19 Rack 500mm Deep. All Connections to the Rear Panel 5109601 TOCSIN 700 4 ANALOGUE/ADDRESSABLE CHANNELS NTROL PANEL 110/230VAC 60W 3 ALARM & 1 FAULT RELAY 5109601DC TOCSIN 700 4 ANALOGUE/ADDRESSABLE CHANNELS 24V DC POWER SUPPLY 3 ALARM & 1 FAULT RELAY 5109602 TOCSIN 700 4 ANALOGUE/ADDRESSABLE CHANNELS 110/230V AC BUILT IN BATTERY BACKUP 3 ALARM & 1 FAULT RELAY 5110001 TOC 700+ NTROLLER 8 ANALOGUE UP TO 64 ADDRESSABLE CHANNELS 110/230V AC 150W PSU 3 ALARM & 1 FAULT RELAY 5110001DC TOC 700+ NTROLLER 8 ANALOGUE UP TO 64 ADDRESSABLE CHANNELS 24V DC POWERED 3 ALARM & 1 FAULT RELAY 5110005 TOC 700 NTROL PANEL 8 ANALOGUE UP TO 64 ADDRESSABLE CHANNELS Ip66 VERSION 110/230V AC 150W 3 ALARM & 1 FAULT RELAY 5110801 TOCSIN 700 16 CHANNEL ANALOGUE UP TP 64 ADDRESSABLE CHANNELS 110/230V AC 150W PSU 3 ALARM & 1 FAULT RELAY 5110801DC TOCSIN 700 16 CHANNEL ANALOGUE UP TP 64 ADDRESSABLE CHANNELS 24V DC POWERED 3 ALARM & 1 FAULT RELAY 5998301 TOCSIN 700+ NTROLLER 8 ANALOGUE UP TP 64 ADDRESSABLE CHANNELS 24V DC PSU WITH PRINTER 19" RACK SYSTEM 5998302 TOCSIN 700+ NTROLLER 8 ANALOGUE UP TP 64 ADDRESSABLE CHANNELS 24V DC POWERED 19" RACK MOUNT SYSTEM TOCSIN 700 SERIES ACCESSORIES 5111101 TOCSIN 700 4 ACCESSORY ENCLOSURE USE TO HOUSE ADDITIONAL I/O CARDS 5074301 4-20mA OUTPUT CARD ACCESSORY CASE MOUNTING 4 OUTPUT CHANNELS AS LINEAR 4-20mA PROCESS 5111001 T700 RELAY OUTPUT CARD ACCESSORY CASE MOUNTING ADDRESSABLE 8 ADDITIONAL RELAY O/P S SP VOLT FREE 5111401 BATTERY BACK UP MODULE TOCSIN 700 PRE-MOUNTED IN ACCESSORY CASE 5133001 TOCSIN 700 EXTENDER CARD ACCESSORY CASE MOUNTING 9 TO 16 CHANNELS 4-20mA INPUTS 5111005 700 RELAY CARD DIN RAIL MOUNTING ADDRESSABLE MOUNTING WITH RIBBON INTERFACE CABLE 5135201 T700 INTERNAL SOUNDER OUTPUT, 80dBA 5138501 TOCSIN 700 PANEL MNT KIT BASE UNIT ONLY 2 SO22 Website: