Sentry G3 Machinery Protection Monitor

Similar documents
Sentry G3 Machinery Protection Monitor

DTM Distributed Transmitter-Monitor

Frequently asked questions: Intelligent Transmitter Series

Speed and Frequency Seite 1 von 7

Temperature Controllers

MHC Series Sensors

condition monitoring WP4086 Condition Monitoring System The WP4086 CMS System surveys vibrations with up to 8 external accelerometers

WP4086 Condition Monitoring System

UDC100 Universal Digital Controller Specifications

Tachometer/Hourmeter/Trip. Installation and Operation Manual

I/A Series 716C 1/16 DIN Temperature Controller

F4 Process Controller Installation and Operation Guide

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5

TEMPERATURE CONTROL MODULE MODEL R3-TC2

metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD.

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Proven Condition Monitoring Solutions

3500/61E & 3500/67E Temperature Monitor

TER Active Room Temperature Sensor (Controller),

02/11/2015

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

VIBstudio is an intelligent platform for online condition monitoring, failure protection and vibration-based diagnostics of machinery.

IntelliPack : 800 Series

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Process & TeMPerATUre UniversAl input DigiTAl MeTers

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

RAYCHEM NGC-30 COMPONENTS

DEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

Nov 08 PRODUCT SPECIFICATION SHEET

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

OVEN INDUSTRIES, INC.

02/11/2015

Wind power Condition Monitoring. Condition Monitoring Systems (CMS) in wind turbines CMS. Authors: Martin Kluge Michael Danitschek

DELOMATIC 400, DM-400 HYDRO

Protection and Condition Monitoring of the LM2500 Gas Turbine

Dew point set DS 400

The Next Generation Machine Protection System

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

Carbon Monoxide Transmitter

AS950 REFRIGERATED SAMPLERS

UDC 700 Universal Digital Controllers and Indicator Specifications

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

EL-OEM-3 OEM Packaged Voltage Data Logger

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

Module Features are-configurable, no module jumpers to set

A36D/TPSD Modbus TCP SCADA INTERFACE INSTRUCTIONS

Di-440 The Modular Analyser

TC515 and TC600 Installation Manual. a Winters company

SUPREMATouch. Modular Fire & Gas Detection System

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

EL-OEM-3 OEM Packaged Voltage Data Logger

Ramsey Motion Monitoring Systems

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

SUPREMATouch. Modular Fire & Gas Detection System

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

System 57. An advanced World of intelligent gas detection system management

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

LORAIN CIP 4890/48120 DC Power System

IVA7008 LEVEL METER - FFT ANALYZER - Auto Range

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

New Sensing products of Meggitt Group. Moscow - October the 23 rd

Specification for On-Line UPS Battery Monitoring and Data Management System

Engine Control Unit, ECU 100 Functional description Additional functions Parameter list

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

Advanced Test Equipment Rentals ATEC (2832)

M2000 Engine Controller

MODEL MP-1S OVERSPEED UNIT

MAJOR CONCERN on your GENERATORS?

Panel Mounted Fault Annunciator Series

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

Moulded case circuit brakers

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

Mobrey MCU900 Series Universal Control Unit

Universal Input Digital Panel Meter With Bargraph, NA3

Size and rating wise typical Third Party Inspection certificates for the models of Valves

RS Pro Infrared Temperature Sensor

Equipment Required. WaveRunner Zi series Oscilloscope 10:1 High impedance passive probe. 3. Turn off channel 2.

D5100 Industrial Differential Pressure Transducer

LC1350 Level Controller

Process Alarm Solutions

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Series Digital Controller Instruction Sheet

Batt-Safe Battery String Monitoring System

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

The EN54 Part 2 & 4 Fire System

ANEMOMETER 4403-RF-BAT

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

LUFKIN WELL MANAGER MODBUS MAP

Transcription:

TECHNICAL INFORMATION Sentry G3 Machinery Protection Monitor CONDITION MONITORING SOLUTIONS The Sentry G3 Machinery Protection Monitor is a high performance signal conditioning unit; providing a universal platform for the interfacing of various sensor types in compliance with the API 670 standard. Each of the four channels can be independently programmed to provide continuous monitoring and protection facilities across a broad spectrum of measurement regimes (including vibration, expansion, temperature, speed, etc). Utilising the latest DSP technology, once a channel is set up and running, the resulting alarm relay and analogue output facilities are independent from the remaining module functionality, resulting in a scalable high integrity configuration. The module is provided with an intuitive colour LCD display and drive facility to provide immediate viewing and access to the machine parameters. Several modes of display are available including bar graph, FFT and an alarm historian. The module provides the necessary power source for the selected transducer, providing for 2 (ICP type) or 3 wire accelerometer variants, ± 24V proximity probe systems, LVDTs and a range of speed & temperature sensors. Each transducer signal is buffered and available via the front panel analogue connection arrangement and a USB interface is provided for programming of the unit and storage of channel history and settings. Machine s Absolute and Relative Vibration Displacement and Thrust Position Speed, Phase and Reverse Rotation Differential and Casing Expansion Rod Drop Temperature Turbine Specialist s Shaft Eccentricity Differential Ramp Expansion Rotor / Stator Air Gap Flexible Configuration The unit is designed for mounting in a custom 19 inch rack assembly which also contains a dual redundant power supply option. The G3 system offers excellent channel density with up to 24 measurement channels in a 3U format. Each channel can provide independent analogue outputs of current and voltage for DCS connection in addition to an alarm relay. Further alarm relay expansion is possible through connection to digital outputs at the rear of the module. LPF, HPF, Tracking and Notch Filters Programmable Warning and Danger Alarms with Relay Logic Cross-Channel Voting Harmonic and Phase Analysis Programmable Transducer Supply Scaleable Module Hardware with plug in DSP card, up to four channels Dual Redundant Power Supply Gateway Communications Module USB Programmable Defeat, Park and Calibration modes DS 1221 1

Absolute Vibration Selectable s AM1 AM2 AM3 AM4 Overall Level, Band limited (LPF & HPF) Overall Level, Fixed HPF & Tracking LPF Overall Level, Fixed HPF & Tracking Notch Fund and Harm Magnitude & Phase Configurable Warning and Danger, negative and positive going alarms per channel. Select from Acceleration (m/s 2 or g), Velocity (mm/s or ips) and Displacement (um or mil). Select from average, rms, pk, pk to pk, pk / rms or db referenced to 20Log 10(1.0V). Filter Characteristics Low Pass Programmable 3dB, 100Hz to 10kHz Roll off >24dB / Octave High Pass Programmable 3dB, 0.1Hz to 100Hz Roll off >24dB / Octave Notch Filter Programmable, 100Hz to 10kHz Constant Q, 35dB rejection For AM1 & AM2 measurements Maximum range setting Acceleration 0 100.0g, ±0.2% typ, ±1.0% max Velocity 0 100mm/s, ±0.2% typ, ±1.0% max Displacement 0 1000um, ±0.2% typ, ±1.0% max For AM3 measurements Maximum range setting Acceleration 0 100.0g, ±1.0% typ, ±3.0% max Velocity 0 100mm/s, ±1.0% typ, ±3.0% max Displacement 0 1000um, ±1.0% typ, ±3.0% max Resolution of displayed readings better than be 1% min For AM4 measurements Maximum range setting Acceleration 0 100.0g, ±2.0% typ, ±5.0% max Velocity 0 100mm/s, ±2.0% typ, ±5.0% max Displacement 0 1000um, ±2.0% typ, ±5.0% max Phase 0-360º, ±1.0º typ, ±5.0º max Noise Floor Acceleration Velocity Displacement 0.001g rms typ 0.02mm/s rms typ 0.05um pk typ s Accelerometer Range 10.00mV/g to 10.00V/g Standard ICP option +24V or -24V 3/4 wire option +24V, -24V or +12V Velocity Transducer Active or Passive option Range 1mV/mm/s to 50mV/mm/s Standard ICP option +24V 3/4 wire option +24V or +12V Transducer Integrity Active device range Passive device Relative Vibration Selectable s AM1 AM2 AM3 AM4 AM5-19.0V to +19.0V O/C and S/C detection Overall Level, Band limited (LPF) Overall Level, Tracking LPF Overall Level, Tracking Notch Fund and Harm Magnitude & Phase Overall Level, dual mode eccentricity Configurable Warning and Danger positive going alarms per channel. Displacement (um or mil), pk or pk to pk, Filter Characteristics Low Pass Programmable 3dB, 100Hz to 10kHz Roll off 24dB / Octave High Pass Fixed 3dB at 0.8Hz, AM1 to AM4 Fixed 3dB at 0.015Hz, AM5 Roll off >24dB / Octave Notch Filter Programmable, 100Hz to 10kHz Constant Q, 35dB rejection Setting resolution, 1% For AM1 & AM2 measurements Displacement 0 1000um max, ±0.2% typ, ±1.0% max For AM3 measurements Displacement 0 1000um max, ±1.0% typ, ±3.0% max 2

For AM4 measurements Displacement 0 1000um max, ±2.0% typ, ±5.0% max Phase 0-360º, ±1.0º typ, ±5.0º max For AM5 measurements Displacement 0 1000um max, ±2.0% typ, ±5.0% max Low Speed mode measurement true pk-pk High Speed mode measurement rms calculated pk-pk LSM to HSM transition 0 50,000 rpm Noise Floor Displacement 0.05um pk typ Eddy Current / Proximity Probe Range 1.00mV/um to 10.00mV/um Fixed Options Thrust / Differential Expansion s AM1 Relative Expansion, Y = mx+c Y is the desired calibrated measurement X is the proximity probe measured value m is a scaling factor resulting from calibration c is an offset factor resulting from calibration AM2 Complementary Expansion, switches between 2-channels either side of a collar arrangement to enhance measurement range, each channel calibrated Y=mX+c. AM3 Dual Ramp Expansion, utilises 2-channels on a ramp collar arrangement (Chan A Chan B) / 2, each channel calibrated Y=mX+c. Dual level, configurable negative and positive going alarms per channel. Displacement mm, um, mil or inch Filter Characteristics Low Pass Measurement Filter 400Hz, 128 sample average Displacement 0 100mm max, ±0.2% typ, ±1.0% max Eddy Current / Proximity Probe Range 0.8mV/um to 10.00mV/um Fixed Options 3 Speed Measurement Parameters Frequency Range Resolution Dynamic range Measurement Range Input Settings 0.02Hz to 20kHz < ±0.1% of reading <±0.1% of full scale 100mV pk-pk 20V pk-pk 0 50,000 rpm 0 1000 Hz Teeth Setting Range 1 256 Threshold mode Manual Level Threshold detection Transistion Manual detection setting +19.0V to -19.0V Overspeed Mode The Overspeed mode when set shall capture maximum machine speed event following a shutdown. This positive going alarm can be allocated to an appropriate relay. Overspeed Mode Overspeed Trigger Zerospeed Alarm Auto / Manual 0 50,000rpm The zerospeed alarm is raised when the shaft rotation drops below a set speed. This negative going alarm can be allocated to an appropriate relay. Zerospeed detection period 1 60 seconds Over Acceleration Alarm The acceleration alarm is raised if the rate of change of speed exceeds the set percentage. This positive going alarm can be allocated to an appropriate relay. Acceleration Setting 1 1000% Acceleration Start 100 50000 rpm Eddy Current / Proximity Probe option 4 wire system -24V @ 50mA max Other Probe options Passive Magnetic Probe Phase Reference (1/rev) 2-wire 10kOhm 2-wire +12V 10kOhm 3-wire +12V 10kOhm When a DSP channel is configured in this mode a phase reference is generated for use by other channels configured in the absolute or relative vibration modes. Up to two channels per module can be configured as a phase reference. The phase reference is selectable from any other module channel connected to the rack system.

Measurement Parameters Frequency Range Resolution Dynamic range Measurement Range Buffered Output Input Settings Threshold mode Threshold detection Manual detection setting 0.02Hz to 20kHz < ±0.1% of reading <±0.1% of full scale 100mV pk-pk 20V pk-pk 0 50,000 rpm 0 1000 Hz TTL Manual Transistion +19.0V to -19.0V Eddy Current / Proximity Probe option 3.94mV/um or 7.84mV/um Other Probe options Passive Magnetic Probe 2-wire 10kOhm 2-wire +12V 10kOhm 3-wire +12V 10kOhm Casing Expansion / Valve Position (LVDT) Expansion or Position, Y = mx+c Y is the desired calibrated measurement X is the LVDT measured value m is a scaling factor resulting from calibration c is an offset factor resulting from calibration Dual level, configurable negative and positive going alarms per channel. Displacement mm, um, mil, inch or % of stroke Displacement 0 1000mm max, ±0.2% typ, ±1.0% max Transducer Drive AC LVDT Amplitude Voltage 3.5Vrms typ Frequency 3kHz ± 5% Integrity Alarms Invalid measurement alarm is raised if reading falls outside of calibrated stroke range. Transducer integrity alarm raised on loss of valid signal from secondary winding. Temperature Two channels of temperature measurement are available for each DSP channel. The DSP channel is fixed to a particular sensor type. Temperature ºC or ºF RTD K-type -20 ºC 150 ºC, ±0.5% typ, ±1.0% max 10mV / ºC -20 ºC 1000 ºC, ±0.5% typ, ±1.0% max 41uV / ºC Junction compensated Integrity Alarm Transducer integrity alarm raised on loss of valid signal from transducer. Reverse Rotation When two DSP channels are configured in this mode a phase reference is generated by each channel for detection in the module of reverse rotation against a multi-toothed target. Consult Sensonics for details regarding the precise positioning requirement of the probes. Measurement Parameters Frequency Range Resolution Dynamic range Buffered Output Input Settings Threshold mode Threshold detection Manual detection setting 0.02Hz to 20kHz < ±0.1% of reading <±0.1% of full scale 100mV pk-pk 20V pk-pk TTL Manual Transition +19.0V to -19.0V Eddy Current / Proximity Probe option 3.94mV/um or 7.84mV/um Other Probe options Passive Magnetic Probe Threshold mode Threshold detection Manual detection setting 2-wire 10kOhm 2-wire +12V 10kOhm 3-wire +12V 10kOhm Auto / Manual Pulse / Gap +19.0V to -19.0V 4

Forward and Reverse Alarm Two alarms are available to provide the status of the rotating shaft. Each alarm can be allocated to an appropriate relay. Zerospeed Alarm The zerospeed alarm is raised when the shaft rotation drops below a set speed. This negative going alarm can be allocated to an appropriate relay. Zerospeed detection period 1 60 seconds Rod Drop The Rod Drop measurement mode monitors the position of a piston rod synchronised to a once per revolution phase reference (configured in a separate channel). Alarm functions are available for relative change in rod position from calibration point and for rod vibration. These positive going alarms can be allocated to an appropriate relay. Displacement, mm, um, mil or inch Displacement 0 4mm max, ±0.2% typ, ±1.0% max Vibration 0 1000um max, ±0.2% typ, ±1.0% max Resolution of displayed readings shall be < 1% Average Rod Drop calculated when no sync pulse available. Eddy Current / Proximity Probe Fixed Options Rotor to Stator Air Gap The Rotor to Stator Air Gap mode monitors the stator wall gap to the rotor poles synchronised to a once per revolution phase reference (configured in a separate channel). Suitable for hydro turbine generator applications the system utilises readings from suitable capacitive displacement probes fixed at positions around the stator. Dual level, configurable negative and positive going alarms per channel. Gap 2 32mm, ±1.0% typ, ±2.0% max Resolution of displayed readings shall be < 1% Gap measurement provided for average, maximum and minimum with pole number for max and min. No. of Poles or samples per revolution, 2 to 128. Capacitive Proximity Probe 333mV/mm 4 wire system +24V @ 150mA max Integrity window 0.1V to 9.9V Common Alarm Features Parameter Alarms Two parameter alarms (A1 and A2) are available per channel, programmable within the set measurement range. Hysteresis, Latching mode and Delay are configurable. Hysteresis 1 to 10%, resolution 1% Delay 1 to 60s, resolution 0.1s Mode Latching or Fleeting For displacement measurements (e.g. thrust, differential expansion, air gap, etc.) each parameter alarm can be configured for both positive and negative going values for window alarming. For speed measurements each parameter alarm can be configured for either positive or negative going. Integrity Alarms The A3 and A4 alarms are allocated to transducer integrity and channel / gap integrity respectively. Hysteresis, Latching mode and delay are configurable. Hysteresis 1 to 10%, resolution 1% Delay 1 to 60s, resolution 0.1s Mode Latching or Fleeting Relay Alarms A single relay is available per channel; this can be allocated to an alarm or group of alarms as required and configured for energised or de-energised to alarm. For further relay expansion eight channels of Alarm I/O are available at the rear terminals for allocation to available alarm parameters. Summary Alarms A single open collector line at the rear terminals is allocated to a First up Alarm for identification of the primary channel alarm in the system rack. Gap, mm or inch 5

Channel Defeat Individual channels can be defeated to disable all alarm functionality and also configured to defeat parameter alarms in the event of an integrity alarm. During defeat all other channel interfaces operate as normal. Alarm Historian All alarm events are stored and time stamped for later access through the front panel display and drive facility. Capacity to store 100 events. Alarm Reset All latched alarm events or individual channel latched alarms can be reset through the front panel display and drive facility. Park Enable Front Panel Facilities Colour LCD display Display Modes Historian 5000pts Size 43mm x 57mm Resolution 240 x 320 pixels Backlight Timeout Function 4 Channel Bargraph 4 Channel Traffic Light All Channel Alarm Historian Single Channel Alarm Single Channel Trend Single Channel FFT 1024pts LED Indicators OK Active Green ALM Active Red TxRx Active Green Communications Navigation USB Type B Interface Windows XP compatible Menu Button Drive Button The Park function permits the analogue outputs to be forced to a preset value in the event of a transducer alarm (user software control only) Buffered Outputs Communications SMB Jack 75 Ohm Analogue Outputs Current and Voltage Outputs Two analogue outputs are available per channel, configurable for either 4 20mA or 0 10V. USB interface for front panel user set up RS-485 Modbus slave at rear terminals Power Supply Amplitude Linearity ±0.5% of range ± 1% of range Module Supply Voltage +18V to +28V Module Power Consumption 15W typ 20W max The analogue output is set across the measurement range as standard. Buffered Outputs For each channel the raw transducer signal is buffered to both the front panel and rear terminals. Frequency Range DC to 10kHz ± 1% For speed and timing measurement modes a TTL signal only is available at the rear terminals. Common Rack Features Trip Level Multiply or Divide; Module detection of this common rack facility will multiply or divide alarm levels when configured for vibration or speed channels respectively. Calibration; Module detection of this common rack facility will force the analogue outputs to a preset value. Alarms can be defeated in this mode if required. Reset; Module detection of this common rack facility will reset all active latched alarms. Set Up Disable; detection of this common rack facility will disable changes via the front panel user interface and disable the USB interface. Tacho 1 & 2: speed and phase marker channels can output tacho signal to backplane for use with other measurement channels Rack Supply Voltage 90-264Vac 50/60 Hz Rack Power Consumption 90W typ 120W max (with 6 modules) Mechanical Module Dimensions Module Mass Temperature 3U x 12HP x 220mm 0.9kg Operating -30 ºC to +65 ºC Storage -30 ºC to +85 ºC CE Marking EN55011 Heavy Industrial Standard conducted & radiated emissions EN61000-3-2:1995 EN61000-3-3:1995 EN55014 Heavy Industrial Standard Immunity EN61000-4-2:1995, EN61000-4-3:1996, EN61000-4-4:1995, EN61000-4-5:1995, EN61000-4-6:1996, EN61000-4-8:1993, EN61000-4-11:1994 Low Voltage Directive EN60950:1992+A1+A2+A3+A4 6

Software Facilities Front panel permits display of channels in various modes. Bar Graph with colour coded alarm status The Sentry G3 User interface provides complete set up and control of all module channels. Uploading measurement algorithms to the DSP card, configuring for sensor input type, measurement mode, alarm alarm levels and analogue outputs. Overall user panel provides intuitive status of the module measured values and alarm status. Traffic Light with colour coded alarm status The channel measurement panel is the same format for all measurement algorithms, providing a common interface for the detailed configuration of the channel parameters. FFT for dynamic channels If you require assistance with any questions please contact your local Sensonics representative 7 Sensonics Ltd Northbridge Road Berkhamsted Herts, HP4 1EF United Kingdom Tel: +44 (0)1442 876833 Fax: +44 (0)1442 876477 www.sensonics.co.uk