V46. Pressure actuated water valves. Refrigeration components Modulating water valves. Catalogue page

Similar documents
V46 2-way Pressure Actuated Water Valves - Commercial Applications

Opening Point Adjustment Range psig (kpa) Commercial Type Non-Corrosive RefrigerantsS (R) 160 to 260 (1103 to 1793) 70 to 150 (483 to 1034)

13-1. Temperature Regulator

Series P215LR/BR Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

V246 Series Two-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

ProRadiant Controls, Valves and Actuators

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

Radiator Valve Program

Three-way reversing valve

V2, V4 and V8 Thermostats Self-acting Temperature Controls I GB-1. Characteristics. Applications. Function. Design

SECTION REFRIGERANT PIPING

PF Series. Piston Actuated Valves

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

THE THERMOSTATIC STEAM TRAP

RA 2000 Series RA 15/6T & TB Conversion Valve

Sealed Type Liquid Line and Suction Line Specifications

Radiator Trap Radiator Valve

RA15/6T & TB Conversion Valve

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)

y Small dimensions. Easy to install in refrigerated counters or cold rooms

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler

Quality Heat Exchangers

Dynamic thermostatic radiator valves DYNAMICAL

Temperature controller for steam (PN 25) AVT / VGS - external thread

TECHNICAL DATA OBSOLETE

Thermostatic Radiator Valves (Caleffi)

TA-Compact-P. Giving you MORE by giving you LESS

SECTION DOMESTIC WATER PIPING SPECIALTIES

STRAIGHT AND ANGLED THERMOSTATIC VALVES

Pressure switch KPU. Data sheet

TECHNICAL DATA. model c-2

Quality Heat Exchangers

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Disc Type Steam Trap TSD-42

PTG series valves 0490EN June 2018 Valves with thermostatic option for radiators, with presetting

Series F61. Liquid Flow Switches. Feature and Benefits. T-body and Pipe-insert types available

Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications

M7100 Pressure Transducer

PureFlow. PureFlow. Fittings system This section doesn t meet California AB1953, Vermont ACT 193 and NSF 61 Annex G Standards.

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

THERMODYNAMIC STEAM TRAP

INSTALLATION INSTRUCTIONS

Dehydrators and Filters

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

pyxis u pyxis ua NEW rcgroupairconditioning

VALVES SECTION 15100

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Brazed Plate Heat Exchanger

Control valves for floor heating systems. Floor Heating Manifolds

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Refrigerated Air Dryer

FSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION. 71

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

Installation Instructions for Med-Touch Series LCD Medical Gas Area, Master & Combination Alarms Conversion Kits

Installation Instructions

610 AC3 CONTROL KNOB (OFF, PILOT, ON) TEMPERATURE SELECTION KNOB ON-OFF REGULATING THERMOSTAT THERMOELECTRIC SAFETY DEVICE.

Deluge Valves. Model 68 DE\ EL. Electrically Actuated Remote-Reset Deluge Valve. Dorot Fire Protection Division. Certification & compliance by design

Flow Control for Fire Protection

Flexible. Upgrade and service with ease Extend lifetime with modular design. Thermostatic expansion valves Type TE5-55

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

I ntroduction. Series F61. Liquid Flow Switches. Feature and Benefits

pyxis pyxisa NEW rcgroupairconditioning

Systems for central heating

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

Thermostatic expansion valves for ammonia Type TEA

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Brazed Plate Heat Exchanger

LIQUIDATOR 450 SERIES

Thermo-Platens. Cast-In Aluminum and Bronze Platen Die Heaters for Plastics Processing Equipment

V246 Series 2-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants

Technical Specification

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

Fuel Manager Diesel Fuel Filtration. FM1, FM10, FM100 and FM1000 Complete Systems, Elements and Service Parts

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Thermostatic valve bodies

HERZ Regulating valve 4002

49 Danfoss Thermostat Kits Ranco Varifix Kits

FLOAT AND THERMOSTATIC STEAM TRAPS FLT17 (DN 1/2 to 1 ; DN15 to DN25)

TECHNICAL DATA OBSOLETE

SOLUTIONS GUIDE. For total efficiency

GASTEC QA. Approval Requirements 6

Series 20 Dual Check Backflow Preventers

F4060 RESILIENT SEATED GATE VALVES

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

REFRIGERANT PIPING SYSTEM

Thermoplastic K-LINK hoses and accessories for refrigeration and air conditioning system

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Water Piping and Pumps

General Characteristics SM185S3QC. Dimensions. Terminal box. Electrical Characteristics. Recommended Installation torques

IDU22C, 22C1, 37C, 37C1, 55C, 75C

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

General information on refrigerant controllers

Honeywell Control Valve. HFP Asia Pacific

CTC EcoZenith i550 Pro All-in-one tank with built-in, intelligent control.

Battery Interconnects

Transcription:

2-way pressure actuated water valves - ommercial applications These pressure actuated modulating valves control the quantity of water to a condenser by directly sensing pressure changes in a refrigerant circuit. The valves can be used in non-corrosive refrigerant systems. mmonia power elements and valves designed for salt-water applications are available. The valves have a quick opening characteristic and open on pressure increase (direct acting). Reverse acting (close on pressure increase) is possible. eatures ffpressure balanced valve design ffpressure actuated ff3/8, 1/2, 3/4 are angled body type valves with high Kv value ff3/8 up to 2 pressure valves all range types ffquick opening valve characteristics ffno close fitting or sliding parts in water passages ffasy to disassemble. ll parts can be replaced ffspecial bronze bodies and monel parts ffpower elements with stainless steel bellows available ffwide range of pressure connection s ffnickel plated seats available for 3/8, 1/2, and 3/4 valves ffirect/reverse action imensions in mm Valve size 3/8 70 1 41 24 92 1/2 80 166 86 51 27 98 3/4 90 181 97 55 36 110 1 2 1 2a 1 2 3 (excl. valve depressor) 1: cm capillary 2: 7/16-20 UN flare nut 34 1: cm capillary 2: 1/4 tube for braze connection (incl. valve depressor mounted into machined flare) 1: cm capillary 2: 7/16-20 UN flare nut 3: copper sealring 15 1/4-18NPT (female) 5 7/16-20 UN

-9600-9608 ngled Size thread according to ISO 228 apillary (cm) dditional features It is possible to change into 45-9602 3/8 100 Nickel plated seat/longer capillary 99-9951 34 With special washer to prevent waterhammer at low flow capacity Nickel plated seat/solder connection.040 i.d.cap./solder connection 9600 1/2 99 34 Solder connection/ 062 id.cap 9600 3/4 9951 34 Solder connection 9300 9301 9606-9609 5 23 ngled 3/8 Nickel plated seat, high range. With washer to prevent waterhammer at low flow capacity Nickel plated seat, high range Nickel plated seat, high range. With washer to prevent waterhammer at low flow capacity 9510 High range 9300 9605 1/2 Nickel plated seat, high range -9951 34 Solder connection, high range -9510 High range -9300-9605 3/4 Nickel plated seat, high range -9510 High range

imension in mm Valve size 1 124 233 8 48 71 1¼ 126 242 144 57-9300 Size thread according to ISO 7-Rc apillary -9510 1-9600 -9300-9510 1¼ -9600-9511 10 23 1-9512 1¼ dditional features It is possible to change into 45 High range

G H J I imensions in mm Valve size G H I J 1½ 7 242 144 18 1 47 67 110 2 168 165 57 125 299 164 20 89 16 2½ 172 185 70 145 Size IN2533 flang connections apillary R-9300 1½ R-9600 S-9300 S-9301 11 18 T-9300 T-9301 11 18 2 2½ 18 dditional features It is possible to change into 45

imension in mm Valve size 3/8 67 6 79 41 24 1/2 80 153 86 51 29 10 3/4 86 163 96 55 35 1 233 8 52 124 71 1¼ 242 144 62-9600 Size thread according to ISO 228 3/8-9600 1/2-9600 3/4-9600 1-9510 1¼ -9600-9510 3/8 apillary dditional features It is possible to change into 45 7-9510 1/2 5 23-9510 3/4-9511 140 Longer capillary -9510 10 23 1 7-9511 1¼ 1 Longer capillary

G H J I imensions in mm Valve size G H I J 1½ 5 242 144 14 1 47 67 110 2 162 165 57 125 299 164 16 89 16 2½ 172 185 70 145 Size IN 86021 flange connections R-9510 1½ R-9600 S-9300 S-9301 11 18 T-9300 T-9301 11 18 2 2½ apillary 18