Air-handling unit (AHU) design manual

Similar documents
AIR-HANDLING UNIT (AHU) DESIGN GUIDELINE

PACKAGED TYPE. Water heat exchanger is built in the outdoor units. OPTIONAL PARTS LIST. Step Interface 3) Flow Temperature Controller 3)

FLOW TEMP. CONTROLLER 3 (Cased) PAC-IF041B-E

Air to Water (ATW) Heat pump, Interface (I/F) and Flow temp. controller (FTC) Technical manual

FLOW TEMP. CONTROLLER 2B (Cased) PAC-IF032B-E

FLOW TEMP. CONTROLLER 2B (Cased) PAC-IF032B-E

Central Home Heating and Hot Water Supply

Application Engineering

Inverter Hot Water Heat Pumps

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

Figure 1: Schematic of internal heat exchanger vapor-injection cycle

AIR CONDITIONERS MODELS PQHY-P650YSHM-A PQHY-P700YSHM-A PQHY-P750YSHM-A PQHY-P800YSHM-A PQHY-P850YSHM-A PQHY-P900YSHM-A DATA BOOK

1. Dimensions Service Space Piping Diagrams Wiring Diagrams Electric Characteristics...

2009 Panasonic Marketing Europe GmbH / All rights reserved

PUHZ-SHW140YHA PUHZ-SHW230YKA

HERO SERIES-DC INVERTER HEAT PUMPS

BASIC HEAT PUMP THEORY By: Lloyd A. Mullen By: Lloyd G. Williams Service Department, York Division, Borg-Warner Corporation

MYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

TECHNICAL & SERVICE MANUAL

Product Data Sheet Refrigeration Dryer DFLO 66 (-W) bis DFLO 2400 (-W)

HP RECESSED HEAT PUMP RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. For use with Mr Slim Outdoor Units

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

AE October 1965 Reformatted October Hot Gas Bypass Control Systems

DATASHEET CoolTeg Plus CW CoolTeg Plus DX CoolTeg Plus XC

FLOW TEMP. CONTROLLER [MASTER] (Cased) PAC-IF061B-E PAC-IF062B-E PAC-IF063B-E. FLOW TEMP. CONTROLLER [SLAVE] (Cased) PAC-SIF051B-E

Best Practices for DX Piping. Greg Drensky Jacco & Associates

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

BLOOD PLASMA Walk-in Freezers

Hot Water Heat Pump Catalogue

GUG-01SL-E GUG-02SL-E GUG-03SL-E

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

ingersoll rand refrigerated air dryers

Scroll Water Cooled Chiller

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

DAVE DEMMA REDUCING ELECTRICAL CONSUMPTION

DAIKIN Modular Inverter Air Cooled Chiller

REFRIGERANT CHANGEOVER

Chapter-8 Capacity Control of Refrigeration Systems

Screw Water Cooled Chiller SCW210

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Heat Pump Water Heater (Generation 4) Troubleshooting (Effective 1 Nov 2016)

DVM S Universal Communication Kit (UCK) Design Guide

SiBE Service Manual. Condensing Unit LRMEQ5-20AY1(E) Booster Unit LCBKQ3AV1(E)

THE FIVE W s SYSTEMES LMP MECHANICAL SUB-COOLING. I.G.A. GIRARD, TERREBONNE, Qc. INCREASED SYSTEM EFFICIENCY & LOWER ENERGY COSTS

Installation Manual for. Series HWM and Non-ETI HYDRONIC WATER MODULE with SC and SD COMPRESSOR UNITS and R-410 REFRIGERANT

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

On Balance: Heat Rejection Control a Packaged Solution

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

Air Cooled Scroll Chiller / Heat Pump

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump

SCA 620C AIR COOLED SCREW CHILLER

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

Technical data. Danfoss DHP-L

PKA-RP60KAL.TH PKA-RP71KAL.TH PKA-RP100KAL.TH

PUHZ-SHW230YKA SERVICE MANUAL R410A. September 2012 SPLIT-TYPE, AIR TO WATER HEAT PUMP. No. OCH534. [Service Ref.] [Model name] CONTENTS

TECHNICAL GUIDE MODELS: DCPM/DHPM PREMIUM SERIES DUCTLESS SINGLE-SPLIT AIR CONDITIONERS AND HEAT PUMPS 22 SEER 1 PHASE 3/4 THRU 3 NOMINAL TONS

SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS PEAD-RP50EA PEAD-RP60EA PEAD-RP71EA PEAD-RP100EA(2) PEAD-RP125EA PEAD-RP140EA

MCQUAY Long Piping Application Manual First Edition November 2005

Executive Summary. Number of Low Number of High Number of Faults , Number of OK

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

Multi-Zone Technical Overview

APPROVAL SHEET SPECIFICATIONS OF HERMETIC SCROLL COMPRESSOR C-SBR180H16A

Installation Manual for CCS Cased Coils with SC, SD, SW Compressor Units and R-410A Refrigerant

WHA 3000P Hot Air Station

Advance Split

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Low Profile Unit Coolers

TEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor

Bringing a year round comfort solutions to extreme climates

Technicians Manual Single Compressor

Inverter scroll compressors VZH hybrid manifold

Ingersoll Rand. Refrigerated Air Dryers

VENTILATION, HEATING AND AIR CONDITIONING*

Suction Accumulators. Introduction. Suction Accumulators

CONTROL PANEL INSTRUCTIONS RSQ-4

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

FLOW TEMP. CONTROLLER 2 (Cased) PAC-IF031B-E

MAC N-407 Air-Cooled Chiller

Inverter scroll compressors VZH hybrid manifold

SEVEN STEPS TO EFFECTIVE PRE- SEASON COOLING CHECKUPS

NORDYNE has received reports of malfunctioning TXV valves in ton split systems and package units.

MODELS LIST. Nominal Capacity RT

3. INDOOR UNIT OPERATION

Gary Parker Refrigerants Product Manager

VENTILATION. Effective heat exchange and fresh air ventilation

Tube-in-tube heat exchanger Type HE

Sunleaves Air Conditioner

Floor-Standing Type(E Series)

Technical Manual Binair Monobloc Heat Pump

WCH5**4. Product Specifications

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

PULSE WIDTH MODULATING VALVES

UA Series Air Dryers. 10 Year Warranty Limited ( SCFM) Setting a new standard in Quality and Reliability WAS 360

Ecodan Air Source Heat Pump and Flow Temperature Controller 2

DC Inverter Smart VRF Products(R410A)

TECHNICAL DATA & SERVICE MANUAL

Transcription:

Air-handling unit (AHU) design manual Contents September 2013 1. Interface unit and line up for Outdoor unit 1 2. System configuration 2.1 Return air temp. control: MANUAL STEP MODE 2 2.2 Return air temp. control: AUTO STEP MODE 3 2.3 Supply air temp. control: MANUAL STEP MODE 4 3. Requirement on AHU design 5 4. System Design Responsibility 6 5. Regulations 6 Related documents: Please also refer to the following manuals PAC-IF012B-E INSTALLATION MANUAL Air to Water (ATW) Heat pump, Interface (I/F) and Flow temp. controller (FTC) Technical manual

1.Interface unit and line up for Outdoor unit 1.1 Interface for AHU MODEL NAME Power supply Dimension(mm) H W D 278 336 69 Weight(kg) 2.5 PAC-IF012B-E (I/F) ~/N(Single Phase), 50Hz, 230V Function AUTO STEP mode MANUAL STEP mode AUTO STEP MODE: * Variable capacity request signals for Heat pump are calculated by INTERFACE MANUAL STEP MODE: * Variable capacity request signals for Heat pump need to be calculated by LOCAL SYSTEM CONTROLLER * System controller can send "Capacity steps" by non-voltage contact signals or analog signals to Interface. With interface, there are steps 1 to 7. * Refer to "Air to Water (ATW) Heat pump, Interface (I/F) and Flow temp. controller (FTC) Technical manual" for details. 1.2 Outdoor unit line up for AHU OUTDOOR UNIT *1 35 50 60 71 100 125 140 200 250 PUHZ-RP - - - - - - - PUHZ-ZRP - - PUHZ-SHW *2 - - - - - - Pipe Diameter Gas φ9.52 φ12.7 φ15.88 φ15.88 φ15.88 φ15.88 φ15.88 φ25.4 φ25.4 Liquid φ6.35 φ6.35 φ6.35 φ9.52 φ9.52 φ9.52 φ9.52 φ9.52 φ12.7 Outdoor operation range refer to the specifications of outdoor unit *1 Basically, model name of outdoor unit shows rated cooling capacity, however, for SHW series, they are named by Air to Water rated heating capacity. Please see below conversion nominal heating list. SHW80: 71 SHW112: 100 SHW140: 125 *2 SHW230 : CAN NOT be used as heat source for AHU. 1

2. System configuration 2.1 Return air temp. control: MANUAL STEP MODE Air Handling Unit Remote Controller (for user interface) Target temp. thermistor RETURN AIR (Room Air) PAC-IF012B-E System Controller FAN SUPPLY AIR Indoor heat exchanger Refrigerant pipe (Gas) Refrigerant pipe (Liquid) Outdoor Unit 2.1.1 Thermistor position : Liquid pipe thermistor : Cond./Evap. temp. thermistor PUHZ-RP PUHZ-ZRP PUHZ-SHW TH1 (SW2-6=OFF) - - (SW2-6=ON) : nessesary -: Unnessesary <Target temp. thermistor ) > Secure thermistor where average return air temperature for heat exchanger can be detected. Secure thermistor where radiant heat from heat exchanger can be avoided. <Liquid pipe thermistor () > Secure thermistor where liquid refrigerant pipe temperature can be detected. Protect the thermistor with heat insulating materials to eliminate affect by ambient temperature, etc. Place the thermistor before distributor head as per example. Example) < Cond./Evap. temp. thermistor () > (RP/ZRP models only) Secure thermistor where Cond./Evap. temperature can be detected on the indoor HEX pipe. It should be located in the middle of inlet and outlet ports. If there are several paths, please locate it on the top one. distributor 2.1.2 Indoor unit operation range Return air operation range COOLING 19~32 HEATING 17~28 2.1.3 Requirement on AHU design Refer to page 6. [3.Requirement on AHU design] 2.1.4 Caution * Please don't select step 0 for 3min. after compressor ON. (= Keep compressor ON for 3 min. at least.) * Please keep operating range shown at 2.1.2. * Auto change-over function between cooling and heating mode is not available with PAC-IF012B-E. * Please don't send STEP 0 during defrost operation 2

2. System configuration 2.2 Return air temp. control: AUTO STEP MODE Air Handling Unit Remote Controller(MA R/C) (for user interface) PAC-IF012B-E System Controller TH1 RETURN AIR (Room Air) FAN SUPPLY AIR Indoor heat exchanger Refrigerant pipe (Gas) Refrigerant pipe (Liquid) Outdoor Unit 2.2.1 Thermistor position TH1: Target temp. thermistor : Liquid pipe thermistor : Cond./Evap. temp. thermistor PUHZ-RP PUHZ-ZRP PUHZ-SHW TH1 (SW2-6=OFF) - (SW2-6=ON) : nessesary -: Unnessesary <Target temp. thermistor (TH1) > Secure thermistor where average return air temperature for heat exchanger can be detected. Secure thermistor where radiant heat from heat exchanger can be avoided. <Liquid pipe thermistor () > Secure thermistor where liquid refrigerant pipe temperature can be detected. Protect the thermistor with heat insulating materials to eliminate affect by ambient temperature, etc. Place the thermistor before distributor head as per example. Example) < Cond./Evap. temp. thermistor () > (RP/ZRP models only) Secure thermistor where Cond./Evap. temperature can be detected on the indoor HEX pipe. It should be located in the middle of inlet and outlet ports. If there are several paths, please locate it on the top one. distributer 2.2.2 Indoor unit operation range Return air operation range COOLING 19~32 HEATING 17~28 2.2.3 Requirement on AHU design Refer to page 6. [3.Requirement on AHU design] 2.2.4 Caution * Please keep operating range shown at 2.2.2. 3

2. System configuration 2.3 Supply air temp. control: MANUAL STEP MODE Air Handling Unit Remote Controller (for user interface) RETURN AIR (Room Air/Fresh Air) PAC-IF012B-E System Controller Target temp. thermistor FAN SUPPLY AIR Indoor heat exchanger Refrigerant pipe (Gas) Refrigerant pipe (Liquid) Outdoor Unit 2.3.1 Thermistor position : Liquid pipe thermistor : Cond./Evap. temp. thermistor PUHZ-RP PUHZ-ZRP PUHZ-SHW TH1 (SW2-6=OFF) - - (SW2-6=ON) : nessesary -: Unnessesary <Target temp. thermistor > Secure thermistor where average supply air temperature for heat exchanger can be detected. Secure thermistor where radiant heat from heat exchanger can be avoided. <Liquid pipe thermistor () > Secure thermistor where liquid refrigerant pipe temperature can be detected. Protect the thermistor with heat insulating materials to eliminate affect by ambient temperature, etc. Place the thermistor before distributor head as per example. Example) < Cond./Evap. temp. thermistor () > (RP/ZRP models only) Secure thermistor where Cond./Evap. temperature can be detected on the indoor HEX pipe. It should be located in the middle of inlet and outlet ports. If there are several paths, please locate it on the top one. distributor 2.3.2 Indoor operation range Return air operation range Supply air operation range COOLING 19~32 10~25 HEATING 0~28 20~60 2.3.3 Requirement on AHU design Refer to page 6. [3.Requirement on AHU design] 2.3.4 Caution * Please don't select step 0 for 3min. after compressor ON. (= Keep compressor ON for 3 min. at least.) * Please keep operating range shown at 2.3.2. * When the fresh air inlet is below 0, heat the air to at least 0 before delivering it to the heat exchanger. * Please don't send STEP 0 during defrost operation. 4

3. Requirement on AHU design 3.1 Indoor unit heat exchanger volume Please make sure to keep the HEX capacity within the following range. If the piping length is 30m or shorter, HEX capacity can be increased as follows. OUTDOOR UNIT 35 50 60 71 100 125 140 200 250 Maximum Volume(cm3) Pipe Length 30m~ 1050 1500 1800 2130 3000 3750 4200 6000 7500 20m 1350 1800 2700 3030 3900 4650 5100 7800 9300 10m 1650 2100 3600 3930 4800 5550 6000 9600 11100 Minimum Volume(cm3) 350 500 600 710 1000 1250 1400 2000 2500 *For other pipe lengths not shown on this table, please calculate them by linear interpolation. 3.2 MAX Air flow volume Please make sure to keep the air flow volume less than maximum air flow volume, shown in the table below. OUTDOOR UNIT 35 50 60 71 100 125 140 200 250 Max Air flow [m3/min] 15 20 23 27 37 46 51 72 89 3.3 Selection of Indoor heat exchanger Please make sure to size HEX properly so that the nominal capacity can be kept within 90%-110% under Standard conditions. <Standard conditions> [1]COOLING Evaporation temp. (refrig.) 10 Superheat at evaporator outlet (refrig 5 Expansion valve inlet temp. (refrig.) 40 Air inlet temp. 27 /19 Ambient temp. (outdoor) 35 /27 [2]HEATING Condensing temp. (refrig.) 45 Superheat at condenser inlet (refrig.) 20 Subcool at condenser outlet (refrig.) 5 Air inlet temp. 20 /15 Ambient temp. (outdoor) 7 /6 <Nominal capacity> OUTDOOR UNIT 35 50 60 71 100 125 140 200 250 COOLING(kW) 3.5 5.0 6.0 7.1 10.0 12.5 14.0 20.0 25.0 HEATING(kW) 4.1 6.0 7.0 8.0 11.2 14.0 16.0 22.4 27.0 3.4 Caution * Diameter of HEADER is very important The refrigerant flow velocity decrease will reduce oil migration through the system, and in turn will effect the lubrication of mechanical components. (The compressor being the number one component that could seize.) Please use the pipe outside diameter or less as shown in the table below. OUTDOOR UNIT 35 50 60 71 100 125 140 200 250 MAX Diameter of HEADER φ19 φ28 * Withstanding pressure Design pressure of outdoor unit is 4.15MPa. The following must be satisfied about burst pressure of connecting appliance. Burst pressure: More than 12.45MPa(3 times more than design pressure) * Contamination maintenance matters Clean inside of heat exchanger to keep it clean. Be sure to rinse and not to leave any flux or residual materials. NB : Do not use chlorine detergent when cleaning. 5

4. System Design Responsibility * Mitsubishi Electric do not accept any responsibility on the local system design. Therefore, Mitsubishi Electric do not accept any responsibility on the failure (incl. outdoor unit) caused by inappropriate AHU design and local system design. 5. Laws and Regulations *Please make sure to comply with localised laws and regulations in terms of the AHU system designed locally. *The declaration of Conformity for our outdoor units and interface is available from the relevant factories. 6