THERMAL INTERFACE UNITS. Designed and manufactured in the UK. Designed for performance

Similar documents
Radiance Thermal Interface Units (TIU) RAPID - RTIU702XXX

heat interface units A BOILER WITHOUT A FLAME

Hot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY

PRODUCT GUIDE JUNE 2018

Euromixer Thermostatic Mixing Valves

Stored Water District Heating Interface Units. Heat Interface Units

The Ultimate Solution for Electric Central Heating. Fusion. Comet

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

The Safety Valve Specialist Thermostatic Shower Controls

InTec 2 X HIGH EFFICIENCY BOILERS LOW CARBON SOLUTIONS

PRODUCT GUIDE WATER CONTROLS FOR A MODERN WORLD HEATING & COOLING DISTRIBUTION SYSTEMS HEATING SYSTEM COMPONENTS

Thermomix Underfloor Heating Control Pack

Herz York Direct Heat Interface Unit

AquaCyl solar system solar water heating solution for the larger home with greater hot water demand (2 or more bathrooms in use simultaneously)

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

SUPERIOR QUALITY HEAT INTERFACE UNITS PUTTING YOU IN CONTROL. Pegler Yorkshire

heat interface units A BOILER WITHOUT A FLAME HIU Single PHE options

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

T. +44 (0) E.

FLEXIBLE METAL - BENDING THE RULES OF PLUMBING CONNECT WITH CONFIDENCE SEE OUR NEW EXTENDED RANGE OF VALVES -

THERMAL STORE MAINS PRESSURE SYSTEM

Installation and Servicing Instructions. Alpha FlowSmart

ModuSat TP. Energy. Heat Interface Units

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Efficient heating that won t cost the earth

GIACOMINI HEAT INTERFACE UNITS

Baxi Combi HE Range. Baxi Combi HE. Keeping Britain Warm

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

THERMAL STORE MAINS PRESSURE SYSTEM

VENTED CYLINDER RANGE

turbomax plus High performance combination boiler range

Shower Panels with a Thermostatic Sequential Control

ModuSat TP. Energy. Heat Interface Units

Biomass. Biomass solid fuel boiler range

Thermostatic mixing valves with replaceable cartridge for centralized systems

EcoSeries S O L A R H O T WAT E R S O L U T I O N S. Ecological & Economical

T. +44 (0) E.

FlowSmart. The high efficiency, high performance space saving heating system.

HI-MAX INSTANT Indirect HIU First Fix Rail / Stand-off Kit Fitting Instructions

Performance & Efficiency.

Sirius FS. Working towards a cleaner future

Where gas is not an option,

ADVANCE ECB ELECTRIC COMBINATION BOILER

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS

QUALITY DESIGN. BUILT-IN RELIABILITY. CYLINDERS. The complete range of Warmflow Cylinders.

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

A homeowner s guide to the Baxi Neta-tec Combi

the electric heating company ELECTRIC BOILER HANDBOOK

DIGITAL HOT WATER SOLUTIONS

WALL-HUNG COMBINATION

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

aquaplus High performance combination boiler with integrated power store

Telo Shower Mixing Valve TL10016CP

Vented systems explained Performance without compromise Vented System (Gravity Fed) Positive Head Systems

Thermostatic bar mixer valve with adjustable head Installation guide

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

The simple solution to a daily challenge

WASHROOM SYSTEMS. PRODUCT GUIDE WATER CONTROLS FOR A MODERN WORLD HEATING SYSTEM COMPONENTS HEATING & COOLING DISTRIBUTION SYSTEMS

EnergyMasterHP. user guide. Cylinder for use with NIBE heat pump systems. v12 Nu-Heat 2017 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

12/11/08. David Pepper- Managing Director Lochinvar Ltd. Steve Addis - Product Manager L.Z.C products

Maincor Underfloor Heating UNDERFLOOR HEATING SYSTEMS. Introduction. Overview. Tel: Web: Why use Underfloor Heating?

Trianco Ltd, Thorncliffe, Chapeltown, Sheffield, S35 2PH Telephone: Facsimile: Website:

water solar heating SOLAR

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

New Zealand Sales Hotline: Sales Fax:

Gas Condensing Boilers

DK-HEAT RECOVERY FOR TRANSCRITICAL CO 2 REFRIGERATION SYSTEMS

The New Caroma TMV20

SOLAR HEATING SYSTEMS

Enzo Concealed Shower Mixing Valve

ecotec plus 937 Power store high efficiency combination boiler

COMPACT HRE ECO RF COMPACT HRE & ECO RF SMART CHOICE FOR HEATING AND HOT WATER

System Design for efficiency using electronic, intelligent HIU s. Neil Parry CIBSE Accredited Heat Network Consultant

Super high efficiency heating and hot water boilers for every type of home and commercial property.

Renewable Range Cylinders providing a perfect partnership with renewable energy inputs SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

Performance on demand

Bar valve with fixed and adjustable shower heads. Installation guide. Midas Plus installation instructions Page 1

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

Puro Mini Dual Control Shower Mixer PU90010CP

ADVANCE ELECTRIC THERMAL STORE

Design & Product Guide. Danfoss FlatStations.

Unvented water heating

INTA ION MODERN BAR / BATH SHOWER MIXER CP

THE REMEHA HIU RANGE Installation, operation and maintenance manual December 2017

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

Compact HRE Boiler Range. The smart choice for heating and hot water

Your guide to. Biomass Heating Systems

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Solar thermal domestic hot water system

Hydronic Mechanical Panels

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

FM Mattsson. Pressure Balancing Thermostatic Mixing Valves FEATURES. - Different on the inside

Gas, oil and heating products. The main line products at competitive prices with even better prices on our VALUE range.

Increase the attractiveness of your multi-family building

SEALED THERMAL STORE

MEGAFLO HE Iss 1

Transcription:

THERMAL INTERFACE UNITS Designed and manufactured in the UK Designed for performance

THE BENEFITS ARE ALL IN THE NAME DEPENDABILITY From the instant we first started supplying the plumbing market and hot water system manufacturers in 1986, Reliance Worldwide Corporation (UK) Ltd. has been the last word in dependability. We are part of Reliance Worldwide Corporation (Aus) Pty Ltd. who are global specialists dedicated to improving and delivering worldleading pressure, temperature and flow control products. INNOVATION Reliance Worldwide Corporation (UK) Ltd. has been, and always will be, at the forefront of innovative and dynamic end-to-end plumbing and heating solutions. With an impressive track record for developing market-leading thermostatic technology in the UK, we owe it all to our customers. By actively listening to and identifying their needs, then developing products to meet and surpass them, we have a formidable reputation for true innovation. RELIABILITY Reliance Worldwide Corporation (UK) Ltd. is all about steadfast reliability. Buy Reliance Worldwide Corporation (UK) Ltd. products once, experience genuine reliability and you become a customer for life. We also offer comprehensive warranties as we have such proven faith in the quality, performance and ultimately the reliability of our products. SIMPLICITY Cutting edge technology is used to design and create Reliance Worldwide Corporation (UK) Ltd. products, with ease of installation and minimisation of maintenance being a key aim. A high quality reliable product that is simple to install not only satisfies customers, it speeds up fitting time. Anything that can make the installer s job easier and faster can only have a positive effect on reducing cost. QUALITY Every Reliance Worldwide Corporation (UK) Ltd. product is manufactured to the highest standards using pioneering techniques and only the very highest quality materials. Our reputation is built on premium quality and high performance. Knowing this, our customers appreciate the convenience of being able to turn to a single supplier to access a truly comprehensive range of ultra-reliable plumbing and heating products. Reliance Worldwide Corporation (UK) Ltd. is an accredited manufacturer to the following International Standards. 2

THERMAL INTERFACE UNITS (TIUs) Radiance TIUs from Reliance Worldwide Corporation (UK) Ltd. offer the perfect solution as they can be adapted to exact requirements when an instantaneous or stored hot water system is required in a Community Heating Network installation. As a leading supplier to the UK heating industry for many years, we have gained a wealth of knowledge and experience in the design and production of innovative products. The Reliance Water Controls brand is recognised for quality and reliability and our TIUs, created specifically to suit UK systems, have been designed, manufactured and tested to ensure they provide the same high levels of satisfaction and longevity. We understand that no two project requirements are the same, that is why we provide a dedicated technical and design support service to work alongside you. This enables us to develop custom-built solutions to meet the exacting needs of your project. We won t just focus on the TIUs, we will ensure your whole system operates as effectively and efficiently as possible to meet every demand. Our Radiance TIUs are manufactured in the UK ensuring lead times are minimal and deliveries can be made to suit a site s requirements. Designed and manufactured in the UK CONTENTS What is a TIU And How Does It Work? 4 High Efficiency Solution for community networks 5 Radiance Range Overview 6 Radiance Features and Benefits 8 Rapid Specification 10 Swift Specification 11 Active Specification 12 Zest Specification 13 Spirit Specification 14 Chill Specification 15 Optional Extras 16 Diversity Charts 18 System Design 21 Conformance and Approvals 21 Guarantee 21 Related Products 22 Tel: +44 (0)1386 712 400 Email: sales@rwc.co.uk 3

WHAT IS A TIU AND HOW DOES IT WORK? TIUs form part of a community heating network (CHN) that provides central heating and domestic hot water to individual properties or apartments within a single development. Traditionally in the UK, housing stocks have been built with individual gas combi boilers located in each apartment. Conversely, across mainland Europe Community Heating Networks - (or District Heating Systems as they were previously known), have long been the solution to provide heating and hot water in large community developments, with a centralised energy centre coupled with a low temperature hot water network. In recent years we have seen a resurgence of CHN developments in the UK as the available technology improves and becomes more popular in helping comply with current legislation for energy efficiency and reduced emissions. Community heating networks operate from a single energy source (the energy centre) that distributes energy in the form of hot water circulating within a primary network throughout a building or housing development. Each individual house or apartment has a secondary network which is connected to the primary network via a thermal interface unit that heats DHW and space heating water via plate heat exchangers to meet the individual demands of the property. Typical apartment type installation ENERGY CENTRE Domestic Hot Water Domestic Hot Water Return Flow Mains Water Supply Typical housing development installation ENERGY CENTRE 4

1 6 5 1. Ball Valves 2. Strainers 3. Diverter Valve 4. Plate Heat Exchanger - Heating (under expansion vessel) 5. Circulation Pump 6. Heat Meter 7. Differential Pressure Control Valve 8. Thermostatic Bypass Valve 9. Primary Zone Valve - Heating 10. Patented Spring Loaded Maintenance Free Expansion Vessel 11. Over Pressure Relief Valve with Pressure Gauge 12. Plate Heat Exchanger - DHW 13. Thermostatic Mixing Valve 14. Flow Sensor - DHW 15. Thermostatic Heating Control Valve 16. Wiring Box 17. Product Information Label 18. Insulated Stainless Steel Pipework 2 13 7 18 8 15 9 16 2 14 11 17 4 12 3 10 HIGH EFFICIENCY SOLUTION FOR COMMUNITY HEATING NETWORKS The absence of gas throughout the building avoids the cost of testing/regulations for installing gas The absence of flues saves cost and allows for an aesthetically pleasing building exterior No planning constraints Simple design; reduced maintenance Easily integrated with renewable heat sources if desired (CHP, biomass, heat pump, solar) Ultra-safe well-known technology using only low pressure hot water Individual metering options available, including automatic meter reading or a prepayment meter Tel: +44 (0)1386 712 400 Email: sales@rwc.co.uk 5

RANGE OVERVIEW The Radiance Thermal Interface Units range comprises six base models. Three instantaneous hot water units, two stored water units and a cooling unit. Our comprehensive range is designed to suit any project requirements. A number of optional extras are also available to suit your exact needs. Please see page 16-17. Rapid Description Indirect heating + instantaneous DHW T V A BUILDING SR SR Secondary Return SF Secondary Flow DHW Domestic Hot Water TVA Tenant Valve Assembly DHW Twin plate heat exchanger unit to generate instantaneous DHW with indirect heating connections. PRIMARY FLOW PRIMARY RETURN MAINS COLD WATER SF APARTMENT RAD RAD RAPID TIU Swift Description Direct heating + instantaneous DHW Single plate heat exchanger to generate instantaneous DHW with direct heating connections. Active Description Instantaneous DHW PRIMARY FLOW PRIMARY RETURN MAINS COLD WATER T V A T V A SWIFT TIU BUILDING SR SF BUILDING SR Secondary Return SF Secondary Flow DHW Domestic Hot Water TVA Tenant Valve Assembly DHW APARTMENT RAD RAD DHW TVA Domestic Hot Water Tenant Valve Assembly Instantaneous Hot Water Single plate heat exchanger to generate instantaneous domestic hot water only. PRIMARY FLOW PRIMARY RETURN MAINS COLD WATER DHW APARTMENT ACTIVE TIU 6

BUILDING SR SF Secondary Return Secondary Flow Zest T V A SR SF DHW DHW TVA Domestic Hot Water Tenant Valve Assembly Description Indirect heating + pre-plumbed cylinder stored DHW Stored Hot Water PRIMARY FLOW PRIMARY RETURN MAINS COLD WATER T V A ZEST TIU SR SF BUILDING PRE PLUMBED CYLINDER DHW APARTMENT RAD RAD SR Secondary Return SF Secondary Flow DHW Domestic Hot Water TVA Tenant Valve Assembly Single plate heat exchanger unit to generate indirect heating. Spirit Description Indirect heating + standard cylinder water storage PRIMARY FLOW PRIMARY RETURN MAINS COLD WATER STANDARD CYLINDER APARTMENT RAD RAD Single plate heat exchanger unit to generate indirect heating. SPIRIT TIU Chilled Water PRIMARY RETURN PRIMARY FLOW MAINS COLD WATER CHILL TIU BUILDING SF SR SR Secondary Return SF Secondary Flow FCU Fan Coil Unit APARTMENT FCU FCU Chill Description Cooling/Air conditioning A single plate cooling unit for air conditioning. Tel: +44 (0)1386 712 400 Email: sales@rwc.co.uk 7

Designed for high efficiency performance FEATURES AND BENEFITS: Designed and manufactured in the UK to be fully compatible with UK heating and hot water systems Highly energy efficient CHN systems are more eco-friendly and economical than alternative heating methods over system lifetime Radiance TIUs are Demand Controlled so there is only flow through the unit when there is a requirement for heat or DHW, which reduces unnecessary heat loss, lime-scale build-up and supports whole system longevity All internal pipe work is manufactured from high quality, flexible, fully insulated corrugated stainless steel pipes which reduce heat loss and permit bespoke configurations to be made with ease WRAS approved Options to suit individual projects Radiance TIUs can be configured with a number of optional extras to suit any individual projects requirements. Reliance Worldwide Corporation (UK) Ltd offer a system design support service to help Architects and Specifiers to ensure maximum energy efficiency is achieved for their projects Individual metering options include automatic meter reading or a prepayment type meters for minimal disruption to occupants. A meter reading service can also be provided via a partner organisation if required 8

Easy to install and commission The absence of gas or flues increase safety for occupants and reduces whole system installation costs in terms of both materials and labour time Connections are made easy with SharkBite push-fit ball valve connectors for an even faster installation. Ball valves with female BSP connections are also available if required Each unit is delivered fully factory assembled and is 100% leak tested prior to despatch to ensure product performance and reduce commissioning time The absence of soldered or brazed joints minimises contamination and leak potential eliminating the requirement for flushing prior to commissioning Reduced maintenance All pipe connections are union fittings sealed with washers for reliable joints and easy maintenance Radiance TIUs incorporate a patented spring loaded expansion vessel which delivers a high performance compact size unit with extended product lifetime which is entirely maintenance free Each unit is marked with a unique serial number, product code and production date to ensure individual product identifications/traceability for maintenance records Tel: +44 (0)1386 712 400 Email: sales@rwc.co.uk 9

RAPID SPECIFICATION Indirect Heating and Instantaneous Domestic Hot Water Unit Weight 45 (approx.) Kg Pressure Rating Primary (max) 10 bar Secondary (max) 3 bar Cold water mains (min) 2 bar Cold water mains (max) 4 bar Temperature Primary (min) 65 C Primary (max) 95 C Domestic hot water 30-60 C Differential Pressure Primary (max) 2.5 bar Primary (min) 0.5 bar DPCV Factory set 0.3 bar Heat Transfer Capacity *Higher kw available Heating circuit 15 kw DHW circuit 42 (Std.)* kw DHW Flow Rate Temp. rise from 10-50 15 l/min Circulation Pump Branded A rated Standard body 130mm(L) with 1½ connections Pump head 6m External Connections Primary flow Primary return Secondary flow Secondary return Boosted cold water Domestic hot water Thermostatic Bypass Adjustable 30-60 C A. 840mm B. 505mm C. 265mm A C B INTERNAL SYSTEM COMPONENTS 10 15 1A 2 3 5 1C M T PF 4 8 11 10 HM M 2 1D PR 1B 6 7 9 12 13 1E TMV 14 1F SF SR DHW BCW 1. Ball Valve Connections 1A - Primary Flow (PF) 1B - Primary Return (PR) 1C - Secondary Flow (SF) 1D - Secondary Return (SR) 1E - Domestic Hot Water (DHW) 1F - Boosted Cold Water (BCW) 2. Strainers 3. Diverter Valve for DHW 4. Plate Heat Exchanger - heating 5. Circulation Pump Heating System 6. Heat Meter (optional) 7. Differential Pressure Control Valve 8. Thermostatic By-pass Valve (optional) 9. Primary Zone Valve - Heating 10. Patented Spring Loaded Maintenance Free Expansion Vessel 11. Overpressure Relief Valve with Pressure Gauge 12. Plate Heat Exchanger DHW 13. Thermostatic Mixing Valve DHW (optional) 14. Flow Sensor DHW 15. Thermostatic Heating Control Valve (THCV) (optional)

SWIFT SPECIFICATION Direct Heating and Instantaneous Domestic Hot Water Unit Weight 35 (approx.) Kg Pressure Rating Primary (max) 10 bar Secondary (max) 10 bar Cold water mains (min) 2 bar Cold water mains (max) 4 bar Temperature Primary (min) 65 C Primary (max) 95 C Domestic hot water 30-60 C Differential Pressure Primary (max) 2.5 bar Primary (min) 0.5 bar DPCV Factory set 0.3 bar Heat Transfer Capacity *Higher kw available Heating circuit 15 kw DHW circuit 42 (Std.)* kw DHW Flow Rate Temp. rise from 10-50 15 l/min External Connections Primary flow Primary return Secondary flow Secondary return Boosted cold water Domestic hot water Thermostatic Bypass Adjustable 30-60 C A. 840mm B. 505mm C. 265mm A C B INTERNAL SYSTEM COMPONENTS 1. Ball Valve Connections 1A - Primary Flow (PF) 1B - Primary Return (PR) 1C - Secondary Flow (SF) 1D - Secondary Return (SR) 1E - Domestic Hot Water (DHW) 1F - Boosted Cold Water (BCW) PF 1A 2 3 M 1C SF 2. Strainers 3. Diverter Valve for DHW 4. Thermostatic By-pass Valve (optional) PR 1B HM 5 6 4 7 M 9 TMV 2 1D 1E SR DHW 5. Heat Meter (optional) 6. Differential Pressure Control Valve 7. Zone Valve Heating 8. Plate Heat Exchanger DHW 9. Thermostatic Mixing Valve DHW (optional) 10. Flow Sensor DHW 8 10 1F BCW Tel: +44 (0)1386 712 400 Email: sales@rwc.co.uk 11

ACTIVE SPECIFICATION Instantaneous Domestic Hot Water Unit Weight 30 (approx.) Kg Pressure Rating Primary (max) 10 bar Cold water mains (min) 2 bar Cold water mains (max) 4 bar Temperature Primary (min) 65 C Primary (max) 95 C Domestic hot water 30-60 C Differential Pressure Primary (max) 2.5 bar Primary (min) 0.5 bar DPCV Factory set 0.3 bar Heat Transfer Capacity DHW circuit 42 (Std.)* kw *Higher kw available DHW Flow Rate Temp. rise from 10-50 15 l/min External Connections Primary flow Primary return Boosted cold water Domestic hot water Thermostatic Bypass Adjustable 30-60 C A. 840mm B. 505mm C. 265mm A C B INTERNAL SYSTEM COMPONENTS 1. Ball Valve Connections 1A - Primary Flow (PF) 1B - Primary Return (PR) 1C - Domestic Hot Water (DHW) 1D - Boosted Cold Water(BCW) 2. Strainer 3. Primary Control Valve 4. Plate Heat Exchanger 5. Thermostatic Blending Valve DHW PF 1A 2 3 M 5 TMV 1C 4 DHW (optional) 6. Heat Meter (optional) 7. Differential Pressure Control Valve 8 8. Thermostatic By-pass Valve (optional) HM 9. Flow Sensor DHW PR BCW 1B 6 7 9 1D 12

ZEST SPECIFICATION Indirect Heating & Domestic Hot Water Unit linked to a Pre-plumbed Cylinder Weight 25 (approx.) Kg Pressure Rating Primary (max) 10 bar Secondary (max) 3 bar Temperature Primary (max) 95 C Secondary (max) 90 C Differential Pressure Primary (max) 2.5 bar Primary (Min) 0.5 bar DPCV Factory Set 0.3 bar Heat Transfer Capacity (At dt=30k and flow=571l/hr) 20 kw External Connections Primary flow Primary return Secondary flow Secondary return A. 840mm B. 505mm C. 265mm A C B INTERNAL SYSTEM COMPONENTS 1. Ball Valve Connections 1A - Primary Flow (PF) 1B - Primary Return (PR) 1C - Secondary Flow (SF) 1D - Secondary Return (SR) 2. Strainer 3. Zone Valve 4. Thermostatic Control Valve (optional) PF 1A 2 3 M 4 T 5 1C SF 5. Plate Heat Exchanger 6. Heat Meter (optional) 7. Differential Pressure Control Valve HM PR SR 1B 6 7 1D Tel: +44 (0)1386 712 400 Email: sales@rwc.co.uk 13

SPIRIT SPECIFICATION Indirect Heating & Domestic Hot Water Unit linked to a Standard Cylinder Weight 35 (approx.) Kg Pressure Rating Primary (max) 10 bar Secondary (max) 3 bar Temperature Primary (min) 65 C Primary (max) 95 C Differential Pressure Primary (max) 2.5 bar Primary (min) 0.5 bar DPCV Factory set 0.3 bar Heat Transfer Capacity Heating circuit 15 kw *Higher kw available Circulation Pump Branded A rated Pump head 6m Standard body 130mm(L) with 1½ connections External Connections Primary flow Primary return Thermostatic Heating Control Secondary flow Secondary return Adjustable 40-70 C A. 840mm B. 505mm C. 265mm A C B INTERNAL SYSTEM COMPONENTS 1. Ball Valve Connections 1A - Primary Flow (PF) 1B - Primary Return (PR) 1C - Secondary Flow (SF) 1D - Secondary Return (SR) 2. Strainers 3. Thermostatic Heating Control Valve (optional) 4. Plate Heat Exchanger PF 1A 2 3 T 4 5 1C SF 5. Circulation Pump Heating System 6. Heat Meter (optional) 7. Differential Pressure Control Valve 8. Zone Valve Heating 10 9. Expansion Vessel PR HM M SR 10. Overpressure Relief Valve With Pressure Gauge 1B 6 7 8 9 2 1D 14

CHILL SPECIFICATION Cooling/Air Conditioning Unit Weight 35 (approx.) Kg Pressure Rating Primary (max) 10 bar Secondary (max) 3 bar Temperature Primary (min) 5 C Primary (max) 15 C Differential Pressure Primary (max) 2.5 bar Primary (min) 0.6 bar DPCV Factory set 0.3 bar Heat Transfer Capacity Cooling circuit 4 kw *Higher kw available Circulation Pump Branded A rated Pump head 6m Standard body 130mm(L) with 1½ connections External Connections Primary flow Primary return Secondary flow Secondary return A. 840mm B. 505mm C. 265mm A C B INTERNAL SYSTEM COMPONENTS 1. Ball Valve Connections 1A - Primary Flow (PF) 1B - Primary Return (PR) 1C - Secondary Flow (SF) 1D - Secondary Return (SR) 2. Strainers 3. Energy Meter (optional) 4. Plate Heat Exchanger 5. Differential Pressure Control Valve PF 1A 2 8 1C 4 SF 6. Zone Valve Cooling 7. Expansion Vessel 8. Circulation Pump Cooling System 9 9. Overpressure Relief Valve With Pressure Gauge HM M PR SR 1B 3 5 6 7 2 1D Tel: +44 (0)1386 712 400 Email: sales@rwc.co.uk 15

OPTIONAL EXTRAS Radiance Thermal Interface Units are designed and manufactured to your individual project requirements. We offer a choice of optional extra components which can be included during assembly to meet your exact specification needs. Our in-house engineering department is available for advice on specification, system design and efficiency. First Fix Rail (FFR) A first fix rail permits phased installation of the unit and is supplied complete with ball valves to allow for pipework to be pre-installed independent of the main TIU. The packaging also includes a handy fixing template to aid the drilling of fixing holes in the correct location. The pipe work can be flushed and pressure tested, before the unit is installed and connected to the system. The FFR is available with or without a flushing bypass valve on the primary side. Ball Valves Connections are made easy with SharkBite push-fit connectors (as standard). Female BSP connections are also available, if required. For more information on SharkBite push-fit plumbing solutions please visit www.sharkbiteplumbing.co.uk Thermostatic By-Pass Valve (TBPV) The thermostatic by-pass valve ensures that the temperature of the primary flow pipe will not drop below the set point by circulating water through the primary system if necessary. This enables instantaneous DHW to be available quicker than if the system cooled completely. The TBPV will only circulate water when required thus reducing the energy loss of the system. Thermostatic Heating Control Valve (THCV) The thermostatic heating control valve offers better control over the secondary flow temperature and keeps the primary return temperature to a minimum which means the network performs at a higher efficiency. Thermostatic Mixing Valve (TMV) - DHW The thermostatic mixing valve controls the temperature of the DHW and limits it to the set temperature reducing scalding risk. Flushing By-Pass Valve An integrated connection/by-pass valve allows flushing of the network whilst by-passing the thermal interface unit. 16

Ultrasonic Heat Meter An ultrasonic heat meter can be installed within the thermal interface unit to accurately meter energy consumption for billing purposes. The M-Bus interface for remote meter reading is included as standard. Mechanical Heat Meter A mechanical heat meter can be installed as an alternative to an ultrasonic heat meter to also accurately meter energy consumption for billing purposes. The M-Bus interface for remote meter reading is included as standard. Water Meter A water meter can be installed to accurately measure water consumption of both hot and cold water for billing purposes. It also includes a pulse output to enable reading by the heat meter. Meter Reading An M-Bus master unit is available to automatically read all meters on the M-Bus network. A wireless radio meter reading device is also available for manual meter reading. This works in conjunction with an android phone or tablet where information will be saved. Prepayment Unit The prepayment unit takes the reading from the heat meter and will shut off the TIU when there is no credit left. The unit communicates with a central server via GSM (Global System for Mobile Communications). It is also certified as an ENE3 display. A partner company is able to offer a full prepayment solution - please contact us for details. Cover Lock A locking mechanism is available to prevent tampering with the unit settings. Tel: +44 (0)1386 712 400 Email: sales@rwc.co.uk 17

DIVERSITY CHARTS Community heating networks show a high diversity on their domestic hot water (DHW) load. The diversity factor depends on how many units are connected to the network and also on the network layout. The maximum network load can be greatly reduced by including DHW diversity. This allows a reduction in the required pipe size, saving on installation and maintenance cost. The charts below give the load factors depending on the number of units connected to a branch or network. 1,00 0,90 Text Book Diversity Factor 0,80 0,70 Diversity Factor based on DIN 4708 0,60 0,50 0,40 0,30 Diversity Factor based on measurements taken from a working Heating Network Diversity Factor used by other manufacturers 0,20 0,10 0,00 0 20 40 60 80 100 120 140 160 180 200 18

Number of concurrently drawing Apartments 3,10 3,00 2,90 2,80 2,70 2,60 2,50 2,40 2,30 2,20 2,10 2,00 1,90 1,80 1,70 1,60 1,50 1,40 1,30 1,20 1,10 1,00 1 Diversity in 1-14 Apartments 2 3 4 5 6 7 8 9 10 11 12 13 14 Number of Apartments 3,90 Diversity in 14-45 Apartments 3,80 Number of concurrently drawing Apartments 3,70 3,60 3,50 3,40 3,30 3,20 3,10 3,00 2,90 2,80 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 Number of Apartments Tel: +44 (0)1386 712 400 Email: sales@rwc.co.uk 19

DIVERSITY CHARTS Diversity in 45-100 Apartments Number of concurrently drawing Apartments 6,20 6,10 6,00 5,90 5,80 5,70 5,50 5,50 5,40 5,30 5,20 5,10 5,00 4,90 4,80 4,70 4,60 4,50 4,40 4,30 4,20 4,10 4,00 3,90 3,80 3,70 3,60 45 50 55 60 65 70 75 80 85 90 95 100 Number of Apartments Diversity in 100-200 Apartments 9,50 9,00 Number of concurrently drawing Apartments 8,50 8,00 7,50 7,00 6,50 6,00 5,50 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 Number of Apartments 20

SYSTEM DESIGN Reliance Worldwide Corporation (UK) Ltd. offer a system design support service for Architects and Specifiers to consult with UK based engineers who are able to offer advice on effective system design to ensure maximum energy efficiency is achieved. Contact us on the number below. CONFORMANCE AND APPROVALS Conforms to Building regulations part L (2010) WARRANTY Radiance Thermal Interface Units (TIUs) are manufactured in the UK from the highest quality components to ensure reliability and maintain longevity. All Radiance TIUs are supplied fully assembled and leak tested with a 2 year warranty* as standard. *subject to terms and conditions which can be found at www.rwc.co.uk Tel: +44 (0)1386 712 400 Email: sales@rwc.co.uk 21

RELATED PRODUCTS Tenant Valves Reliance Water Control Tenant Valves are an innovative, compact, 5-in-1 solution for the control and monitoring of incoming water supplies. Ideal for multi-occupancy buildings with several service provisions. Includes PRV, Pressure Gauge, Isolating Valve, Double Check Valve and Water Meter Port. Easy to service and maintain with its cartridge design construction. Significantly reduces leak potential. Saves labour time, cost and saves space. Supplied pre-insulated. Heat Pack The Reliance Water Controls Heat Pack is a useful all in one domestic heating system kit that contains all the common components required on a domestic heating system, including 2 x 22mm Zone Valves, a Wiring Centre, a Two Channel Programmer, a Contact Thermostat and an Electronic Room Thermostat. Components are also available to purchase individually. SharkBite Fittings, Valves and Pipe SharkBite is the world s most versatile range of metal push-fit fittings and valves for joining Copper, SharkBite PEX, Carbon Steel and Polybutylene pipes, in any configuration. With no solder, flux or heat required, SharkBite is ideal for applications where flamed jointing is not permitted. All fittings are manufactured from an ultra-low lead DZR brass and are electrically continuous (when used with metal pipe). They are also easily detectable behind stud walls in the event of future works. SharkBite fittings are rated up to 120 C at 10 bar so are ideal to use to connect right up to the TIU. All SharkBite fitting and valves are fully demountable (using a special tool) and are instantly reusable saving additional expense. Heating Controls Reliance Water Controls Touchscreen Programmable Thermostats provide precise temperature control within +/- 1 C and are available in a stylish white or black gloss case to suit any interior decor. The thermostats incorporate an easy to read digital LED display, with seven day programming, with up to six events per day. 22 For further information on any of the products above or to view the full Reliance Worldwide Corporation (UK) Ltd. range, please visit www.rwc.co.uk

Harron Valves The Harron Valve, a combined Thermal Balancing and Pressure Reducing Valve is the latest time saving innovation from Reliance Water Controls. This compact, two in one solution, reduces leak potential and the possibility of installation error. It is supplied complete with its own bespoke insulation case further saving time and cost. It is suitable for hot water applications and incorporates a built-in disinfection function to protect against legionella, a dry-fit thermometer, easy to read pressure indicator dial, integral strainer and SharkBite connectors for even quicker installation. A version is also available with MBSP union connections which permit ease of servicing. Thermal Balancing Valves Reliance Water Controls Thermal Balancing Valves automatically balance and maintain optimum temperatures in potable hot water systems and are supplied complete with their own unique moulded insulation. Fully adjustable with a tamper-proof cap and designed to incorporate a host of benefits including a built-in disinfection function to protect against legionella and a dry-fit push in thermometer which means there is no need to drain down the system for installation. Reliance Thermal Balancing Valves are also available with SharkBite connectors for even quicker installation. Water Meters Reliance Water Controls offer a comprehensive range of silent operation single and multi-jet, water meters for either hot or cold applications. The compact design permits both vertical or horizontal installation. All models incorporate a fully rotational dry dial enabling easy reading of the meter regardless of installation position. Pressure Reducing Valves (PRVs) Reliance Water Controls offer a comprehensive range of drop tight Pressure Reducing Valves suitable for both domestic and commercial, hot and cold water applications. All products in the range utilise a single piece cartridge design, which permits easy maintenance and can be installed in any orientation. Tel: +44 (0)1386 712 400 Email: sales@rwc.co.uk 23

FOR FURTHER INFORMATION OR TO MAKE A PROJECT ENQUIRY, PLEASE CONTACT US: Reliance Worldwide Corporation (UK) Ltd Worcester Road, Evesham Worcestershire WR11 4RA Tel: +44 (0)1386 712 400 Fax: +44 (0)1386 712 401 Email: sales@rwc.co.uk www.rwc.co.uk facebook.com/reliancewatercontrols @RWCUK In the interests of continuous product improvement Reliance Worldwide Corporation (UK) Ltd. reserve the right to alter specifications as necessary. E&OE. Copyright 2015 Reliance Worldwide Corporation (UK) Ltd. Copyright 2014 Radiance. All trademarks and registered trademarks are the property of Reliance Worldwide Corporation (UK) Ltd. All rights reserved. ISSUE 1-06/15