Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion

Similar documents
Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Product Data FEATURES/BENEFITS. 524J PACKAGED AIR -HANDLING UNITS WITH PURONr REFRIGERANT SIZES 07, 08, 12, 14, 16. Indoor air quality features

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz

Installation, Start-Up and Service Instructions

Product Data. 40RUA/40RUS 6to15TonDirectExpansion 7.5to15TonChilledWater Packaged Air---Handling Units FEATURES/BENEFITS. Indoor air quality features

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Product Data FEATURES/BENEFITS 524J***H 6 TO 20 TON DIRECT EXPANSION PACKAGED HEAT PUMP AIR -HANDLING UNIT. Indoor air quality features 524J-H 07-12

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

50TJM Nominal Cooling Capacity Tons HFC R - 410A Refrigerant

Product Data. Features/Benefits. 38ARZ ARS012 38ARD AKS with 40RM Commercial Air-Cooled Split Systems 50 Hz

BAC / BHC SERIES 7-1/2 to 20 Ton Air Handlers

Commercial High-Efficiency Condensing Units

PAJ3. Product Specifications

Models 566D 569C,576B with 524A 6to30Tons

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Commercial High-Efficiency Condensing Units

Models PF1A PF1B PACKAGED AIR-HANDLING UNITS. 6to10Tons. Form No. PDS PF1A.72.1 FEATURES/BENEFITS

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

MAC N-407 Air-Cooled Chiller

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

40 RM/RMS Packaged Air-Handling Units

INSTALLATION INSTRUCTIONS FAS/FHS Series, Package Air Handling Units 6 to 25 Ton Air Conditioners 6to20TonHeatPump

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

Product Data. Features/Benefits. 19XB Positive Pressure Storage System

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

2 shp 13 lc 1 36 t - 1 a

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )

COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 20 TONS

Product Data. Features/Benefits ComfortLink control

MACH N-407 Heat Pump Air-Cooled Chiller

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )

Indoor Air Handlers with Compressors MVS and MVW

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

Installation, Start-Up and Service Instructions

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

WJH4 Product Specifications

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

Air-Cooled Condensing Units with Compact Screw Compressors

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons

50TM COMBINATION HEATING/COOLING UNITS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Call us today! (800)

Duct Free Systems Product Data Digest ¾ to 5 Nominal Tons

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

Product Data. Features/Benefits. 09DE,DK Air-Cooled Condensers. 15 to 90 Nominal Tons

50TM TFF COMBINATION HEATING/COOLING UNITS

PACKAGE AIR CONDITIONER

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

PRODUCT SPECIFICATIONS

VariCool VAV Engineering Guide

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

Advance Product Data

PAR5. Product Specifications

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

Product Data. Features/Benefits. 50TJ Single-Package Rooftop Units Electric Cooling with Electric Heat Option 50 Hz

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

Product Data. Features/Benefits. PERFORMANCE 13 50XZ SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

13 SEER PACKAGE GAS / ELECTRIC UNIT (575V -3 Ph -60Hz) 36 to 61 MBtuh

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility allow for timesaving

Advance Release September 2009

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons

Product Data. 50ZP Single-Package Air Conditioners. 2 to 5 Tons

WCH5**4. Product Specifications

R4H4. Product Specifications

Advance Product Data

Product Data. Fig. 1 - Unit 50VR -A

VertiCool Aurora Engineering Guide

Product Data. Fig. 1 - Unit 50VG -A

C13-Series Engineering Guide

Transcription:

38ARZ/ARD Commercial Air-Cooled Split Sizes 007-028 With 40RM007-028 6-25 Nominal Tons - 50Hz Product Data The 38ARZ/ARD condensing units with scroll compressors match Carrier s 40RM indoor-air handlers for a wide selection of dependable commercial cooling solutions. Carrier s air-cooled split systems: provide a logical solution for commercial needs have a rugged, dependable construction Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion coils with outdoor condensing units for a wide selection of commercial cooling solutions. Up to 11.0 EER The high efficiency split commercial split system combining the 38ARZ/ARD outdoor condensing unit with 40RM air handling unit can save 20-27% of energy consumption. Constructed for long life The 38ARZ (single circuit, scroll compressor) and 38ARD (dual circuit, scroll compressor) models are designed and built to last. The copper tube-aluminum fin outdoor coil construction provides years of trouble-free operation. Where conditions require, a range of Enviro-Shield coil protection options are available. Cabinets are constructed of prepainted galvanized steel, delivering unparalleled protection from the environment. Inside and outside surfaces are protected to ensure long life, good looks, and reliable operation. Safety controls are used for enhanced system protection and reliability. 38AR-01 PD 50Hz 2011

Efficient operation Building owners will appreciate the high unit EERs (Energy Efficiency Ratios) offered by the 38AR units. These units provide greater efficiency than similar units in the marketplace, which translates into yearround operating savings. Controls for performance dependability The 38AR condensing units offer the building owner operating controls and components designed for performance dependability. The highly efficient compressors are engineered for long life and durability. The compressors include overload protection and vibration isolation for quiet operation. The high pressure switch protects the entire refrigeration system from abnormally high operating pressures. A low pressure switch protects the system from loss of charge. The 38ARD014-028 units feature 2 compressors and 2 refrigerant circuits that provide continuous air conditioning and design flexibility. All units include a crankcase heater to eliminate liquid slugging at start-up. The latest safety standards for 38AR units are UL, compliant. Innovative Carrier 40RM packaged air handlers are custom matched to 38AR condensing units The 40RM Series has excellent fan performance, efficient direct-expansion (DX) coils, a unique combination of indoor-air quality options, and is easy to install. Its versatility and state-of-the art features help to ensure economical performance of the split system both now and in the future. Indoor-air quality (IAQ) features The unique combination of IAQ features in the 40RM Series air handlers help to ensure that only clean, fresh, conditioned air is delivered to the occupied space. Direct-expansion (DX) cooling coils prevent the buildup of humidity in the room, even during part-load conditions. Unit sizes of 10 tons and larger feature dual-circuit coils for improved temperature control. Standard 1-in. aluminum washable filters remove dust and airborne particles from the occupied space for cleaner air. The pitched, non-corroding drain pan can be adjusted for a right-hand or left-hand connection to suit many applications and provide positive drainage and prevent standing condensate. Economy The 40RM Series packaged air handlers have low initial costs, and provide reduced installation expense and energy-efficient performance. Quick installation is ensured by the multipoise design. Units can be installed in either the horizontal or vertical configuration without modifications. Fan motors and contactors are prewired and thermostatic expansion valves (TXVs) are factory-installed on all 40RM models. High efficiency, precision-balanced fans minimize air turbulence, surging, and unbalanced operation, cutting operation expenses. Rugged dependability The 40RM series units are made to last. The die-formed galvanized steel panels ensure structural integrity under all operating conditions. Galvanized steel fan housings are securely mounted to a galvanized steel fan deck. Rugged pillow-block bearings (40RM014-034) are securely fastened to the solid steel fan shaft with split collets and clamp locking devices. Smaller unit sizes have spider-type bearings. Coil flexibility Model 40RM directexpansion coils have galvanized steel casings; inlet and outlet connections are on the same end. The coils are designed for use with R-22 refrigerant and have 3/8-in. diameter copper tubes mechanically bonded to aluminum sine-wave fins. The coils include matched, factoryinstalled thermostatic expansion valves (TXVs) with matching distributor nozzles. Easier installation and service The multipoise design and component layout ensures quick unit installation and operation. Units can be converted from horizontal to vertical operation by simply repositioning the unit. Drain pan connections are duplicated on both sides of the unit. The filters, motor, drive, TXVs, and coil connections are all easily accessed by removing side panels.

Model number nomenclature 38AR Z 007 -- - 9 0 1 S Type 38AR Commercial Air- S - High Ambient Cooled Condenser Packaging 1 - Standard Z-Single Circuit D- Dual Circuit Design Series 0 - Original Design Nominal Capacity in-tons 007-6 Tons 008-7.5 Tons 012-10 Tons 014-12 Tons 016-14 Tons 024-20 Tons 028-25 Tons -- - Not Used Voltage 9 400 3 50 Fin Type -- - Standard Bare Fins C- Cu/Cu Coil P- Pre-Coated Blue Fins

Physical Data English ARZ ARD UNIT 38AR 007 008 012 014 016 024 NOMINAL CAPACITY (Tons) 6 7.5 10 12 14 20 OPERATING WEIGHT (lb) Aluminium Coils (Standard) Copper Coils (Optional) 300 352 383 484 430 531 676 822 740 886 764 904 COMPRESSOR Scroll Qty Oil Charge (oz) 88 90 110 60(ea) 85(ea) 110(ea) REFRIGERANT TYPE * Operating Charge, Typical (lb) ** Shipping Charge (lb) FINISH CONDENSER FAN R22 12 20 22 11.5/circuit 14/circuit 2.0 3.1 Gray Propeller Type Qty RPM 2 700 2 920 2 900 Diameter 22 in 26 in Nominal Air Flow (Total CFM) 5000 5800 9210 Watts (Total) 330 505 1050 CONDENSER COIL (Qty) 2 Face Area (sq ft Total)) 29.2 29.2 Rows Fins/in. 1 17 2 17 3 15 Storage Capacity (lb)*** 17.3 34.2 48 CONTROLS Pressurerestart Settings (psig) High Cutout Cut-in Low Cutout Cut-in DISCHARGE GAS THERMOSTAT ( 0 F) Cutout Cut-in PRESSURE RELIEF Location Tempreature --- 428 ± 10 320 ± 20 27 ± 3 44 ± 5 270 ± 9 190 ± 13 Suction Line 200 PIPING CONNECTION Qty Suction 1 1 1/8 1 1 1/8 1 1 3/8 2 1 3/8 Qty Liquid 1 3/8 1 3/8 1 1/2 2 1/2 Hot Gas Stub 3/8 428 ± 10 320 ± 20 27 ± 4 44 ± 7 --- Liquid Line 200 028 25 127 153 111(ea) 17.97 /circuit 2 900 30 in 1300 1300 50.4 3 16-2 1 3/8 2 5/8 - ARZ ARD UNIT 38AR 007 008 012 014 016 024 028 SHIPPING DIMENSIONS (in) (W X H X D) (59.2X45.5X39) (72.6X44.25X41.7) (96.5X49.6 X54.3) *Unit is factory-supplied with holding charge only. **Typical operating charge with 25 ft of interconnecting piping. ***Storage capacity of condenser coil with coil 80% full of liquid R-22 at 95 F. 4

Options and accessories 38AR, options Enviro-Shield condenser options offer pre-coated coils that provide protection in mild coastal environments. Several options are available to match coil protection to site conditions for optimum durability. See table below. Consult your Carrier representative for further information. Non-fused disconnect switch to remove power locally at the condensing unit. This switch also includes a power lockout capability to protect the service person. This lockout switch saves the service person time and effort because there is no need to access a distant disconnect switch while servicing the unit. Carrier s line of thermostats provide both programmable and non-programmable capability with the new Debonair line of commercial programmable thermostats. The Commercial Electronic thermostats provide 7-day programmable capability for economical applications. PremierLink Controller is a field retrofit split system control compatible with the Carrier Comfort Network (CCN) and other building automation systems (BAS). This control is designed to allow users the access and ability to change factory-defined settings thus expanding the function of the standard unit. CONDENSER COIL OPTIONS COPPER TUBE COILS WITH ENVIRO SHIELD OPTION Al Fins (Standard Coils) Cu Fins Al Fins, Pre Coated ENVIRONMENT Standard Mild Coastal Moderate Coastal X X X LEGEND Al Aluminum Cu Copper Electrical data VOLTAGE COMPRESSOR COMPRESSOR FAN MOTORS POWER UNIT NOMINAL RANGE* 1 2 (Qty 2) SUPPLY SIZE VOLTAGE 38AR V-Ph-Hz FLA LRA MIN MAX RLA LRA RLA LRA MCA MOCP (ea) (ea) Z007 400-3-50 360 440 9.6 82 -- -- 0.5 0.9 12.4 20 Z008 400-3-50 360 440 13.5 95 -- -- 0.8 1.6 17.9 30 Z012 400-3-50 360 440 20.7 130 -- -- 0.8 1.6 26.9 45 D014 400-3-50 360 440 9.6 82 9.6 82 1.7 -- 27.8 30 D016 400-3-50 360 440 13.5 95 13.5 95 1.7 -- 38.0 45 D024 400-3-50 360 440 20.7 130 20.7 130 1.7 7.5 56.0 70 D028 400-3-50 360 440 22.9 145 22.9 145 3.0 -- 63.3 80 LEGEND FLA Full Load Amps LRA Locked Rotor Amps MCA Minimum Circuit Amps per NEC, Section 430-24 MOCP Maximum Overcurrent Protection (amps) RLA Rated Load Amps (compressor) *Units are suitable for use on electrical systems where voltage supplied to the unit terminals is not below or above the listed limits. NOTES: 1. The MCA and MOCP values are calculated in accordance with thenational Electrical Code (NEC), Article 440. 2. Motor RLA and LRA values are established in accordance with Underwriters Laboratories (UL), Standard 1995.

Base Unit Dimensions 38ARZ 007 012 Approximate Shipping Weight Approx. Shipping Dimensions 38ARZ Size With Standard Al/Cu Coil With Optional Cu/Cu Coil ( A x B x C ) KG LB KG LB mm inch 007 154 339 178 392 008 192 422 238 524 (1504X1157X992) (59.2X45.5X39) 012 213 467 259 570

Base Unit Dimensions 38ARD 014 024 Approximate Shipping Weight Approx. Shipping Dimensions 38ARD Size With Standard Al/Cu Coil With Optional Cu/Cu Coil ( A x B x C ) KG LB KG LB mm inch 014 357 785 423 931 016 386 849 452 994 (1844X1124X1058) (72.6X44.25X41.7) 024 397 873 461 1014

Base Unit Dimensions 38ARD 028 Approximate shipping weight Approx. shipping dimensions 38ARZ With standard Al/Cu Coil With optional Cu/Cu Coil (A B C) size KG LB KG LB mm Inch 028 580 1279 695 1532 2451 1380 1282 96.5 54.3 50.5