Fixed Gas Detectors Portable Gas Detectors Flame Detectors SmartWireless Control Solutions Gas Analyzers GF-00002A-EN

Industrial Grade Gas Detection Detecting The Difference

Industrial Grade Gas Detection

Industrial Grade Gas Detection

SIL 2. Ultima X Series Gas Monitors CERTIFIED

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Sieger Apex. Flexibility that meets your requirements

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

ALTAIR 5X Multigas Detector Product Specification

Monitores Personales. Personal Monitor

Toxic Gas Detection. Model F12. Toxic Gas Detection

Model D12. Digital Gas Transmitter

BM25 and BM25 Wireless

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

The Art of Gas Detection

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

RIG RAT III. Wireless Multi-Point Gas Detection System. The Stand-Alone Solution

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

SAFESITE Multi-Threat Detection System

Better detection. Better protection. Fixed Gas & Flame Detection Product Overview - North America Region

ALTAIR 5X Multigas Detector

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Equipment. Model R002. Description. SF6 leak detector

3M Oldham OLCT 100. Description. Fixed Gas Detector

ESD3000 ESD200 Combustible / Toxic Gas Detector

OLC(T) 100 FIXED GAS DETECTOR

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Leak detector for refrigerant gases R22, R134a, R410A, R407C...

ESD500. ESD500 Combustible / Toxic Gas Detector

APPLICATION DATA SHEET

Model Series 700. detcon. Environmentally Bulletproof Gas Detection Sensors. Multi-Layer Surge Protection Water-Proof Corrosion-Proof

Global. Products. The Power To Protect

Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

SP-220. Features. Combustible handheld gas leakage detector

DETCON MODEL SERIES 700 GAS DETECTORS

incontrol Systems Inc. Flame and Gas Detection

MSA Portable Gas Detection

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

Gas Detection For Life

DETCON MODEL SW-AV2-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Fixed Gas & Flame Detection Product Overview - EMEA Region

Frequently Asked Questions

DETCON MODEL SW-AV1-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

GAS DETECTOR ST400EC PART.NO

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

GasAlertMicroClip X3 Specifications

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

ALTAIR 5X Multigas Detector

Satellite XT. Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

Warranty Registration

Fixed Gas & Flame Detection International Product Range Overview

Global Gas Detection and Monitoring Solutions

IGD.CO.UK

Model D12-IR. Digital Gas Transmitter...

MERIDIAN UNIVERSAL GAS DETECTOR

Two-Channel Gas Controller

Products and performance

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

G-TECTA TM. Portable Gas Detection Instruments

The Dräger X-am 1700/2000 are a new generation of personal gas detectors.

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

Dräger X-am 7000 Multi-Gas Detection

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

YOUR PARTNER IN FIRE & GAS DETECTION

Model 1000 H 2 S E-Chem/ CO 2 Process Analyzer

Hazardous Gas Detection System. [ for Homeland Security ]

Personal & Portable Gas Monitors

PHD6. Flexible, comprehensive monitoring backed up by high performance functionality

MSA Gas Detection. for the Water and Wastewater Industries. Does your facility meet NFPA 820?

Dräger REGARD -1 Control System

Micro III (Models G203, G203S, and G213) Operation Manual

Dräger Flame 2100 Flame Detection

For the Safety of Your

Dräger X-am 5000 Multi-Gas Detection

DETCON MODEL AV1/AV2-C1D2M Hazardous Duty Class I. Div 2, Multitone Alarm Station

Portable Gas & Flame Detection Product Overview

DETCON MODEL AV2-C1D2C Hazardous Duty Class I. Div 2, Continuous Tone Alarm Station

VENTIS PRO SERIES. Product Guide

Meridian. Universal Gas Detector. Description. Features. Minimal drift High specificity Digital ID Broader toxic gas detection

RAE Systems Systems. User Presentation. October Protection Through Detection

Transcription:

detcon inc. SmartWireless Gas Detection Technology for Today s Industrial Environment Catalog #SW0315

SmartWireless Site Sentinel Transportable Gas Detection System Detcon s advanced SmartWireless Site Sentinel is a lightweight, transportable gas detection system that can be fitted with one, or a combination of electrochemical and infrared sensors to monitor toxic gases and/or combustible hydrocarbons in heavy industrial environments. Designed for reliability in rugged environments, each system includes a tripod, network HMI, gas detection sensor(s), and alarm warning devices. An optional Sentinel SiteWatch provides remote access to system data via Ethernet or cellular communication. Power to the sensor assembly is supplied by a rechargeable Smart Battery Pack, disposable batteries or directly from HMI. Flexible and expandable, a Site Sentinel network can include up to 32 devices and consist of any combination of wireless and/or wired sensors, one or more HMI panels and optional solar panels. Additional sensors and/or remote alarm stations on tripods can be added as needed to assure widespread alert to site personnel.

SmartWireless Sensor Technology Wireless Battery Powered Devices Eliminate Expensive Installation Costs Quick and Easy Deployment Permanent or Temporary Installations Fault Tolerant Safety Network Network Capacity up to 32 Devices Description No Single Point of Failure Universally Acceptable Frequency 2.4 GHz Low Power Requirement 1.5 Mile Line-of-Sight Range As wireless capabilities reach new technological milestones the integration of wireless gas detection systems in industrial applications is increasing. Among the smartest and most revolutionary product lines available today is Detcon s SmartWireless technology. Easy to customize for a wide range of locations and heavy industrial applications, wireless components include toxic and infrared combustible gas detectors, controllers, remote HMIs, network configuration tablets, audio visual alarm stations, solar panels and rechargeable or disposable batteries. For remote access via ethernet or cellular application, the Sentinel SiteWatch is a new innovative solution. CXT Sensor Assemblies Detcon s Model CXT sensor is a compact, low powered, wireless gas detector that monitors for dangerous combustible & toxic gases and oxygen deficiency. This environmentally bulletproof gas detector has a built-in display and is powered by either rechargeable or disposable batteries. CX Sensor Assemblies Detcon s Model CX sensor is a wired version of the Model CXT that can be used with SmartWireless Site Sentinel CX/CXT Controllers as well as other Detcon control systems. Standard outputs include 4-20 ma, and RS-485 Modbus. Detectable Gases Combustible Hydrocarbons Acetylene C2H2 Ammonia NH3 Arsine AsH3 Bromine Br2 Butadiene C4H6 Carbon Monoxide CO Chlorine CL2 Chlorine Dioxide CLO2 Diborane B2H6 Ethanol C2H5OH Ethyl Mercaptans C2H5SH Ethylene C2H4 Ethylene Oxide C2H4O Fluorine F2 Formaldehyde CH20 Hydrazine N2H4 Hydrogen H2 Hydrogen Bromide Hbr Hydrogen Chloride HCL Hydrogen Cyanide HCN Hydrogen Fluoride HF Hydrogen Sulfide Methanol CH30H Methyl Mercaptan CH3SH Nitric Oxide NO Nitrogen Dioxide NO2 Oxygen Deficiency O2 Ozone O3 Phosphine PH3 Silane SiH4 Sulfur Dioxide SO2

SmartWireless HMI Up to 32 Devices, Wired or Wireless NEMA 4X Div 1 & Div 2 Packages Available Configurable up to eight zones SD card with datalogging Alarm and Fault Condition LEDs Display Indicates: Field Device Location, Alarm Status, Channel, Gas Reading, Battery Life & Signal Strength Site Sentinel CXT Controller The SmartWireless Site Sentinel CXT Controller provides operator interface to the network and real time status display of all network devices. Flexible and expandable, a Site Sentinel network consists of any combination of (up to 32) wireless and/or wired sensors, one or more control panels, and alarm warning devices. Command functions include alarm reset, alarm acknowledge, alarm test and radio silence. The control panel displays real time gas concentrations, field device status, battery levels, network RF signal quality and fault diagnostic conditions. Display indications include field device location, alarm status, channel, gas reading, battery life & link signal strength. Site Sentinel CX Sensor Station The Site Sentinel CX Sensor Station transmits data from up-to 4 wired gas detectors back to a CXT controller. The sensor station includes a battery that powers the radio, alarm devices, and the attached sensors. SmartWireless X40 Alarm & Control System Model X40 controller provides many of the same features and capabilities of the Site Sentinel CXT controller and can include up to 32 wired devices whereas the CXT controller can accommodate up to 4 wired devices. The Model X40 also allows for expanded use of Detcon addressable I/O modules that include a 4-channel 4-20mA input module (DA-4), a 4-alarm relay output module (RL-4), a 4-channel 4-20mA output module (AO-4), and a 4-relay contact input module (DI-4). Detcon modules can be mounted within the main system enclosure or installed remotely to simplify field wiring. SmartWireless MCX-32 Alarm & Control System In addition to providing many of the same capabilities of the Model X40, the MCX-32 adds 64-channel capability and an advanced touch screen display. Log File Viewer Data Logging Software Detcon Log File Viewer is an advanced catalog viewing system designed for use with the Site Sentinel, X40 and MCX-32 controllers. The software allows gas sensor information that is recorded by the controller to be stored on a secure digital memory card that can then be uploaded and viewed on a PC, laptop or tablet. Detcon Log File Viewer displays detailed sensor information in an easy-to-read chart format that can be examined by date, individual channel, or by event to include alarms, communication errors, calibration cycles, and TLV-TWA/Peak readings.

SmartWireless Alarms SW-AV Series Audio Visual Alarm Stations Detcon SmartWireless audio-visual alarm stations are easily and economically deployable in both permanent and temporary installations. These devices feature a battery powered audio visual alarm station designed as a wireless cordless system component and are available in Class 1; Div 1 and Class I; Div 2, packages. The standard rechargeable battery packs are capable of delivering enough energy for 4-6 hours of continuous operation in a full alarm condition or 5-6 months (no alarm condition). An optional solar charging panel can be used to extend operating time and maintain full battery charge levels for virtually any application. An optional battery pack that uses disposable D cells (3.6V) is capable of delivering even longer operating times. Alarm relay options include adjustable set points and latching/non-latching relays. The audible alarm can be configured for acknowledge/silence via operator interface at the SmartWireless controller (CXT/X40/MCX-32). Alarm Bar Audio Visual Alarm Stations Alarm Bar audiovisual alarm stations consist of a siren and packaging options for two or four strobes. The Horn and Strobes meet NEMA 4X watertight, dust-tight requirements and are rated Class 1, Div 2. Alarm components are pre-assembled and packaged in a NEMA 4X rain tight enclosure that can be pipe or wall mounted. SmartWireless CXT Sensor with Visual Alarm Detcon s Model CXT wireless gas detection sensors can be configured with an integral visual alarm strobe. The visual alarm supplements zoned alarm indicators by providing point indication of hazardous gas conditions.

Sentinel Sitewatch Remote Monitor Automated emails for gas detection alarm and fault conditions on both smart and cellular phones Email includes last 10 minutes of detector s output prior to going into alarm/fault and coming out of alarm/fault Strong SSL/TLS-based encryption ensures security Configurable up to eight zones SD card with datalogging Description Sentinel SiteWatch is an advanced networking device that provides remote access to any Detcon gas detection system via Ethernet or cellular communication. The Sentinel SiteWatch Ethernet version provides an IP addressed web page that can be accessed via any web browser and both the Ethernet and Cellular versions provide automated emails for all alarm and fault conditions instantaneously. SiteWatch technology can be embedded into the Detcon Model CXT, X40 & MCX-32 wireless controllers. The Sentinel SiteWatch allows web browser access to real time data from the gas detection system that includes: detector type, serial number, location/name, gas concentration, gas type and alarm status. In addition, when used with Detcon SmartWireless systems, the data includes battery life and link quality of all devices in the network via LAN connection. Sentinel SiteWatch allows convenient and efficient access to remote system data by computer (desktop, portable, tablet) and cellular devices (iphone, Droid, etc.) virtually any device that has ethernet, wifi or cellular access. Site Sentinel X40 MCX-32 RS-485 In Cellular Remote Alerting Smart Phone/ Cell Phone Tablet Sentinel SiteWatch Ethernet + Remote Alerting PC LAN Wifi Laptop TYPE CXT SENSOR CXT SENSOR ALARM STATION HMI SERIAL # 937643 937644 937645 937646 LOCATION/NAME SHALE SHAKER MUD TANK MUD PIT/SHALE SHAKER DOG HOUSE CONCENTRATION 0 50 GAS TYPE PPM % ALARM OK ALARM 3 STATUS OK OK OK OK BATTERY LIFE 45+ DAYS 45+ DAYS 60% 45+ DAYS LINK QUALITY 100% 100% 80% 100%

BM 25W Wireless Transportable Monitor Up to 5 gases simultaneously 103 db at 3 feet audible alarm Ultra-bright flashing signal at 360 Run time of up to 135 hours Resistant to harsh environments Easily transportable - less than 15 lbs Up to 30 devices per network Up to 16 independent networks More than 0.5 mile RF line of site Only 4.5 hours recharge time Description The BM 25W is a rugged, user-friendly and transportable multi-gas monitoring system that offers a wide range of applications. It was designed for mobile or temporary work applications, team protection, area surveillance or places where fixed detection systems are not suitable. The BM 25W is durable and versatile. It is suitable for a wide range of industries including refineries and pharmaceutical production. Applications include turnaround work sites, rig overhauls and fence-line surveillance. The system detects up to 5 gases and can include up to 30 devices in a standard network. Should a device fail or an obstruction occur, communication automatically re-routes allowing the network to remain in operation. Powered by a NiMH battery pack, the BM 25W offers up to 135 hours of continuous run time. The monitor is equipped with a 360 flashing signal and an audible alarm rated 103 db at 3 feet. Standard features include STEL and TWA values and data logging capacity of more than four months (for 5 gas configuration). An intrinsically safe trickle charger is also available for long-term area monitoring in classified zones. Wireless communication is made via a 2.4 GHz radio and emitted power is less than 100 mw. Maximum distance between two communicating devices is 0.6 mile line of sight. The BM 25W is compatible with Detcon s CXT, X40 & MCX-32 Wireless controllers.

SmartWireless Network Technologies Detcon s SmartWireless systems are available in two technologies - Standard Mesh Network (320 System), and Fault Tolerant Safety Network (300 System). Both use an innovative mesh network topology that allows each device in the network to act as a router and repeater for every other device in the network. Therefore, if an instrument s signal is obstructed from communicating with the Master it will automatically reroute through another instrument to maintain communication. This technology creates a robust network that is not hindered by line-of-sight obstacles. Configuration and commissioning in the Standard Mesh Network is at the network HMI (CXT, X40 or MCX-32 Controller). Standard Mesh Network Obstruction gas Detcon s proprietary Fault Tolerant Safety Network is designed with an additional and unique innovation in mesh-networking to ensure network protection and stability. Data processing capability is embedded in each device in the network, guaranteeing that no single point of failure will interrupt communication between devices. Therefore, if the master device fails the network automatically elects another device to take over as master. This feature significantly enhances the redundancy and overall safety level of the wireless system. Detcon s Configuration Tablet is used to configure and commission the Fault Tolerant Safety Network. Fault Tolerant Safety Network New Master Automatically Elected Master Fails gas

SmartWireless Applications Tank Farm CXT-IR Sensor gas X40 Tank Tank RXT To Plant Wide Annunciation PLC RS-485 to PLC Alarms Alarms Doghouse Completion Site Perimeter Fence Line SO2 CX Sensor Station with Solar Workover Rig Flare Stack MCX-32 in Trailer

Battery Options for Wireless Applications Plug In High Energy Lithium Ion Technology Rechargeable & Replaceable/Disposable Options Industry Leading Run Times Twist Lock D Cell Replacable Smart Rechargeable C Cell Replacable Four Pack Charging Station Smart Rechargeable and D Cell replaceble battery packs are interchangeable without any changes in electronics. Rechargeable and Disposable Battery options include rechargeable packs as well as packs with disposable/replaceable batteries. Both use lithium ion technology and are available in low and high capacity versions. Detcon battery packs provide continuous run times for months at a time. Paired with a solar charging option Detcon SmartWireless system components can provide indefinite run times. The battery packs are packaged as a plug in module that uses a mechanical guide and gold plated mating connectors. A smaller compact version is packaged with a twist-lock design. Both are housed and secured inside a Division 1 enclosure. Optional solar charging panels are available in Class I, Div 1 (1.5 and 3 Watt) and Class I, Div 2 packages (5, 10, 20, 30 and 40 Wattt). Integrated safety circuitry continuously monitors each battery pack. If the discharge current exceeds the battery rating the output will be turned off until reset. If the voltage drops below operating levels the output will be turned off until the battery is recharged (rechargeables) or replaced (replaceables). Rechargeable packs are also protected from over voltage during charging. Battery Run Times CXT Gas Detectors C Cell Replaceable Rechargeable High Capacity Rechargeable D Cell Replaceable Model CXT-DM and CXT-IR 2 months 5 months 6 1/2 months 9 months Audio Visual Alarms* No Alarms Full Alarms - Continuous C Cell Replaceable na na Rechargeable High Capacity Rechargeable D Cell Replaceable 5 months 6 1/2 months 6 1/2 months 4-7 hours 5-9 hours 5-9 hours * Typical - See product data sheet for specific run times

Specifications (Abbreviated - See Specific Product Data Sheets for Full Specifications) CX & CXT Sensor Assemblies Sensor Type Electrochemical for Toxics and Oxygen Non-dispersive Infrared Optical (NDIR) - Combustible Gas Sub-miniature Plug-in Field Replaceable Input/Output 2.4Ghz DSSS Radio Transmission (CXT) 4-20 ma and RS-485 Modbus (CX) Power Input 9-30 VDC and/or Internal Battery Pack with C Size (3.6V) disposable batteries Optional internal Battery Pack with D Size (3.6V) disposable batteries Optional Lithium Ion Rechargeable Battery Pack Safety Approvals Explosion proof CCSAUS Class I, Division 1, Groups C, D (Tamb = -40 C to +60 C) Class I, Zone 1, Group IIB ATEX Ex d ib IIB T4 Gb (Tamb = -40 C to +60 C) CE Marking Performance Approvals CCSAUS Performance tested to ISA 12.13.01-2000 and CSA 22.2 #152 Site Sentinel HMI Capacity Up to 32 Input Devices Display 1 1/4 x 6 Backlit LCD Electrical Classification (Designed to) Class I; Division 2; Groups A, B, C, D NEMA4 General Purpose Power Input External: 11.5-30 VDC Internal: Rechargeable Smart Battery (up to 60 days operation) Operating Temperature Range -20 C to +70 C; -4 F to +158 F Alarm Stations Input Voltage 24VDC Electrical Classifications Available Class I; Div 1; Groups C, D Class I; Div 2; Groups A, B, C, D Sound Output 115dB @ 1m (1kHZ) (Div 2 Version) 95dB @ 1m (1kHZ) (Div 1 Version) Tones On-board choice of 15 tones (Div 2 Version) 32 Selectable (Div 1 Version) Strobe Colors Amber, Blue, Clear, Green, Purple, Red (Div 2 Version) Amber, Blue, Clear, Green, Opal, Red, Yellow (Div 1 Version) Alarm Bar Input Voltage: 12-48VDC Electrical Classification: NEMA 4X Class I; Div 2; Groups A,B,C,D Sound Output: 115dB @ 1m Tones: 32 Selectable Strobe Colors: Amber, Blue, Clear, Green, Purple, Red Sentinel SiteWatch Signal Input: RS-485 Signal Output: Ethernet; Cellular Power Input: 115-230 VAC Electrical Classification NEMA 4X corrosion resistant weatherproof Network Configuration Tool Display 10.1 Wide (LED Backlit, 1366x768) Dual Bonded Processor/Cache Intel Atom Z670 processor (1.5 Ghz) Inputs Touch (Capacitive Multi-Touch) and Pen (Active Stylus) Input Voltage 100-240VAC~1.5A, 50-60Hz Lithium-Ion Battery with 43WHr capacity (up to 8 hours) Operating Temperature Range 41ºF to +109ºF, +5 C to +43 C BM 25W Display: LCD with backlight Sensor Type Electrochemical for Toxics and Oxygen Catalytic Diffusion for Combustible Gas PID for Isobutylene Infrared for CO2, Methane, Propane Butane, Isobutane, LPG, Ethanol and Pentane Audible Alarm 103 db @ 1 meter Visual Alarm Ultrabright LED beacon visible 360 degrees Run Time: 135 hours Battery Options Smart Rechargeable Pack Power Rating - 13.2 AH; High Capacity Version - 17.4 AH Operating Temperature Range -20 C to +60 C; -4 F to +140 F Pack with Disposable C Cells (3.6V) Power Rating 8.5 AH Operating Temperature Range -55 C to +85 C; -67 F to +185 F Pack with Disposable D Cells (3.6V) Power Rating 19 AH; High Output Version - 13 AH (for alarms only) Operating Temperature Range -55 C to +85 C; -67 F to +185 F -40 C to +85 C; -40 F to +185 F (High Output Version) Solar Power Options Electrical Classification 1.5 and 3 Watt - Class I; Div 1 Groups C, D 5, 10, 20 and 40 Watt - Class 1, Div 2

Corporate Headquarters 4055 Technology Forest Blvd. The Woodlands, Texas 77381 713-559-9200 888-367-4286 Fax 281-292-2860 sales@detcon.com www.detcon.com Customer Service Center 25003 Pitkin Rd. D800 Spring, TX 77386 713-559-9230 Fax 281-292-2860 service@detcon.com