SenSmart Universal Gas Detector Series

Similar documents
SenSmart 5000 Series "The Art of Gas Detection"

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Certificate of Compliance

The Art of Gas Detection

Universal Gas Detector Series Operations Manual Hwy 6 Hitchcock, TX UM-1067 Revision 6

S5000 Gas Monitor. GMS5000.com

incontrol Systems Inc. Flame and Gas Detection

ULTIMA X5000. MSAX5000.com

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Industrial Grade Gas Detection

APPLICATION DATA SHEET

GAS PLUS ALARM SYSTEM

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Model D12-IR. Digital Gas Transmitter...

Dräger Polytron 8310 IR Detection of flammable gases and vapour

IGD.CO.UK

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Industrial Grade Gas Detection

SEC 2000 Millenium Infrared Gas Detector

Dependable Solutions for Gas Detection

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

APPLICATION DATA SHEET

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Model D12. Digital Gas Transmitter

EXAMPLES OF HOW TO ORDER

Products and performance

Dräger Polytron 5100 EC Detection of toxic gases and vapors

EXAMPLES OF HOW TO ORDER

XNX Universal Transmitter

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8000 Stationary gas detector (EC)

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Touchpoint Pro Flexible Gas Control System

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Operation & Maintenance Manual

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 8100 EC Detection of toxic gases and vapors

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

APPLICATION DATA SHEET

Quick Start Guide. XNX Universal Transmitter

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Zareba Sensepoint Pro

YOUR PARTNER IN FIRE & GAS DETECTION

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

Two-Channel Gas Controller

SUPREMATouch. Modular Fire & Gas Detection System

Sieger Apex. Flexibility that meets your requirements

Dräger Polytron 8310 Stationary gas detector (DSIR)

Air Check EX LEL Gas Monitor Instruction Manual

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

Industrial Grade Gas Detection Detecting The Difference

Operation and Maintenance Manual

Carbon Monoxide Transmitter

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Model FMD. Field Mounted Display Module

Dräger Polytron 5720 IR Toxic Gas Detection

Oxygen (O2) Single-Point Gas Detection System

Warranty Registration

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

P R O D U C T D ATA S H E E T

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Dräger GS01 (wireless) Detection of flammable gases and vapours

Recalibrate the way you look at gas detection

Multi-Gas-Controller MGC2

Dräger Polytron 8000 Stationary gas detector (EC)

GAS DETECTION International Gas Detectors CH4 NO

Global Gas Detection and Monitoring Solutions

Sensepoint XCD. Flammable, toxic and oxygen. catalytic, electrochemical cell and infrared sensors.

Toxic Gas Detection. Model F12. Toxic Gas Detection

INSTALLATION AND OPERATING INSTRUCTIONS

SUPREMATouch. Modular Fire & Gas Detection System

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Danfoss gas detection units

Danfoss gas detection units

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

Dräger Polytron 7000 Fixed gas detector

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

Toxic and Explosive Smart Gas Monitor PN / Installation and User Manual

RIG RAT III. Wireless Multi-Point Gas Detection System. The Stand-Alone Solution

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

Dräger Polytron 8720 IR Detection of carbon dioxide

HART TOCSIN 903 SINGLE CHANNEL GAS DETECTOR USER INSTRUCTIONS. Oliver IGD Limited NEW WITH OPTIONAL. 4a Pepper Road Stockport SK7 5BW England

OLC(T) 100 FIXED GAS DETECTOR

RAEGuard 2 PID. User Guide

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

Transcription:

SenSmart Universal Gas Detector Series Installation Guide Flammable & Toxic Gas Detectors Smart Alarm Controllers Fire & Gas System Engineering Technical Service & Support Warning: Read & understand contents of this manual prior to operation. Failure to do so could result in serious injury or death.

A TRULY UNIVERSAL SERIES The Universal Gas Detector Series consists of a common processor board connected to various combinations of input /output options. The models are based on wireless vs wired communications; and powering as follows: SenSmart 4000 Low-power, 4-20mA loop powered gas detector for toxic and oxygen detection. Includes a 4-20mA output. SenSmart 5000 10-30VDC powered gas detector for toxic, oxygen, combustible, VOC and CO2 detection. This model adds a color backlit LCD display, and has Modbus and/or 4-20mA communications and relays available. SenSmart 8000 Battery powered wireless gas detector for toxic, oxygen, combustible and CO2 detection. Available in either 900MHz or 2.4GHz models. SenSmart 8000X 10-30VDC powered wireless gas detector for toxic, oxygen, combustible and CO2 detection. This model adds a color backlit LCD display. *All models use RC Systems latest Smart Sensor technology, providing smarter gas detection with simplified solutions.

SenSmart 4000 SenSmart 5000 SenSmart 8000 SenSmart 8000X Universal Gas Detector Series

GETTING STARTED Gas Detector Installation and Power-up 1 Installation of Gas Detector A. Mount the Gas Detector in desired location. (see Figure 1 for mounting dimensions.) B. Remove windowed lid from unit. 1. AL Enclosure unscrew lid and remove thumbscrew to access terminals 2. PY Enclosure - unscrew (4) lid screws to access terminals C. Remove thumb screws and pull display to the side. (Aluminum Enclosure) www.rcsystemsco.com

Figure 1 - mounting dimensions Aluminium Polycarbonate Universal Gas Detector Series

GETTING STARTED Power Up/Standard Output Installation 2 SenSmart 4000 A. Connect the +10-30VDC/4-20mA loop wires to terminals TB2.1 and TB2.2 (See Figure 2) 3 SenSmart 5000 and SenSmart 8000X A. Connect 10-30VDC power lead to TB2.1 (See Figure 3) B. Connect Common lead to TB2.3 (See Figure 3) C. Connect signal lead to TB2.5 (4-20mA Out) (See Figure 3) D. For SenSmart 8000X wireless network setup, please refer to the Universal Gas Detector Manual 4 SenSmart 8000 A. Ensure 3.6V Lithium D Cell battery is installed observing proper polarity B. Hold magnet over UP/ON key to turn gas detector on C. For SenSmart 8000 wireless network setup, please refer to the Universal Gas Detector Manual www.rcsystemsco.com

Figure 2 - SenSmart 4000 wiring Figure 3 - SenSmart 5000/8000X wiring Universal Gas Detector Series

FINALIZE INSTALLATION 1 A. Replace display and tighten screws. B. Apply power to unit and observe power up screen. C. After the warm up period, observe gas type and gas concentration on screen. D. Using appropriate magnet, swipe Down Key on the display. Follow on-screen prompts to perform calibration check. www.rcsystemsco.com

OPTION INSTALLATION 1 10-0531 SenSmart 5000 RS485 Modbus Option A. RS485 Modbus Master Port TB1 provides a Modbus Master Port. Please refer to the Universal Gas Detector Manual for Communication Port setup. B. RS485 Modbus Slave Port A and B terminals are tied together to allow for the daisy chaining of gas detectors along a Modbus network. (Refer to Universal Gas Detector Manual for Communication Port Setup) Figure 4 - RS-485 Modbus option wiring Universal Gas Detector Series

OPTION INSTALLATION 1 10-0532 SenSmart 5000 RS485 Modbus / Relay Option A. RS485 Modbus Master/Slave Port TB1 provides a Modbus Master/Slave Port, which is programmable from the gas detector. Please refer to the Universal Gas Detector Manual for Communication Port setup. B. Relay Outputs 2 programmable 5A SPDT Relays (RLY1 and RLY2) with a single dedicated failsafe fault relay (see Figure 6). (Refer to Universal Gas Detector Manual for Communication Relay Setup) Figure 5 - RS-485 Modbus/Relay option wiring www.rcsystemsco.com

SPECIFICATIONS Power Supply SenSmart 4000 SenSmart 5000 SenSmart 8000X Loop Powered 10-30 VDC at <.75 watt 10-30 VDC at < 6.5 watts with relay board (SenSmart 5000 only all relays energized) 4-20MA Output SenSmart 8000 SenSmart 4000 SenSmart 5000 SenSmart 8000X Replaceable internal D-cell lithium battery; 9 months Toxic/Oxygen and 6 months LEL operation 2-wire 4-20mA current Sink. Max loop R is 600 ohms with nominal 24VDC power supply 3-wire 4-20mA current source. Max loop R is 750 ohms with nominal 24VDC power supply Modbus Output SenSmart 5000 MODBUS slave ports Wireless Output SenSmart 8000 SenSmart 8000X FHSS 900 MHz and 2.4 Ghz Wireless Relay Output SenSmart 5000 3x programmable alarm relays with 5A capability Enviornmental Approvals Warranty ALL SenSmart 4000 SenSmart 5000 ALL ALL Operating range -40 C to +60 C Sensors include sensor heater for low temperature operation Relative humidity to 95% for IR; to 85% noncondensing when using electrochemical sensors CSA Class I, Div1, Group A, B, C, D, Class I, Zone 1, Group IIC, T4 CSA Class I, Div 2 Groups A, B, C, D, Class I, Zone 2, Group IIC, T4 5 year limited warranty For sensor warranty see sensor specifications sheet. Universal Gas Detector Series

R.C. Systems provides 24/7 superior technical support from experts right here in our local facility. If you are in need of any assistance during the setup of this product, you may contact our main office and your call will be directed appropriately. At R.C. Systems we are proud to supply quality products and are happy to help if you have any questions or concerns. 8621 Highway 6 Hitchcock, TX 77563 Tel: (409)986-9800 Fax: (409) 986-9880 www.rcsystemsco.com MM-1060