Commercial Fan Heater

Similar documents
MODELS HSCFH60WX, HSCFH90WX, HSCFH120WX

Surface Warm Ceiling Heaters

Recessed Warm Ceiling Heaters

SURFACE WARM CEILING HEATERS

RECESSED WARM CEILING HEATERS MODELS HSRCH3000RF, HSRCH4500RF INSTALLATION AND OPERATING MANUAL

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

Instruction Manual WARNINGS

QUALITY SPACE HEATERS

INDEX WARNINGS AND RECOMMENDATIONS 2 COMPLIANCE DECLARATIONS 3 RANGE AND SIZES 3 ELECTRICITY SUPPLY 3 INSTALLATION 4 INSTRUCTIONS FOR UNINSTALLING

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

T-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

This price list supersedes all previous issues. Prices are in pounds sterling and do not include VAT.

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

Contact Details. Please note that some of the contact details on this PDF document may not be current.

ES3247B. 3 Channel Programmer. User and Installation Instructions

AC500T, AC1000T, AC1500T, AC2000T

SHORT WAVE INFRARED PANEL DRYER

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

Model: Available in : Sapphire Black and Glacier White. 1 Series

ivector HEATER/COOLER 2 AND 4-PIPE MODELS.

Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

PHV-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

CentaurPlus ZW and HRT4-ZW

ECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance

Space Saver. Installation and user manual. Issue 001 March 2018 ENGLISH UK IRL SmithsEP.co.uk. Issue March 2018 smithsep.co.

16 XD Mk2 Inset Electric Fire

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Model: Touch-RS. 1 Touch-RS

The Professional s Choice

Contents. Warning: Installation... 2 Warning: Operation...2 Warning: Disposal...3

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

Digital Room Thermostat

Electronic Dual Cylinder Thermostat Installation Instructions

Operating and Installation Instructions


irad Wireless Controller

16 Ultiflame Inset Electric Fire

FWC153, FWC304, FWC604 & FWC624

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

FWC152, FWC303, FWC603 & FWC623 Wine Coolers Installation, Use and Maintenance

CET B-RF Wireless Electronic Hot Water Cylinder Thermostat User & Installation Instructions

Underfloor Heating Programmable Thermostat

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters

HERSCHEL SUMMIT 2600 HERSCHEL SUMMIT 2600R Ceiling or Wall-mounted Infrared Heaters

User and Installation Instructions. Opus 700 Electric Salamander Grill OE7304 IS318 ECN3011

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Pie Warmer. Instruction manual. Model: GF454-A/GF455-A

For the user / for the installer. Instructions for Use and Installation. time SWITCH hour time clock

Imperial Electric Fires

ELECTRIC UNIT HEATER REGULAR DUTY

Quick start guide. Connected wireless room thermostat. Logic Combi C / Logic Max Combi C / Vogue Gen 2 Combi / Vogue Max Combi

Thank you for choosing EnviroVent

Vacuum Cleaner MC-E3003 MC-E3001. Operating Instructions. Model No.

CET2000B-RF + RX1-S + CS2

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

EVG Extractors. Manual for Installation, Use and Maintenance

Model : PRT-EN Model: PRT-EN1

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

User and maintenance manual

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

Installation, operating and servicing instructions

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

Ecostrad Amalfi. Wall-mounted Infrared Heater INSTALLATION & OPERATING INSTRUCTIONS. 3kg 2 Years (excludes lamp & remote control) IP65

Cooker Hood CHIM60 CHIM70 CHIM90 CHIM101 CHIM110. Installation & User s instructions

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

Model: Slimline-N. 1 Slimline Series

Oceanic Sauna Heater Manual

WHHR Midi & Midi Lite

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

HI-LINE LV FAN CONVECTOR MODEL: 7-4.

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

AP-EH500-L/RQA9837. Installation Guide

5KW ELECTRIC FAN HEATER

INSTRUCTIONS FOR USE. To make the most of your new oven, read the user's instructions carefully and keep them on hand for consultation in the future.

READ AND SAVE THESE INSTRUCTIONS

SUTTON 52 CEILING FAN

Hive Active Heating. Thermostat installation guide

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

RF Programmable Room Thermostat Installation Instructions

AMBIRAD QUARTZ GLOW INSTANT INFRA-RED HEATERS INSTALLATION AND OPERATING MANUAL

Bx OVEN SET UP AND OPERATION OF OVEN AND CONDENSER UNIT (IF FITTED) CLASSIC

air pump 2700/4500 ? 2YEAR GUARANTEE UK AIRPUMP _33435 CASC /10/ :16 Page 1

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

Installation & User Instructions: Model: Arizona/Broadway/Corsano/Compton/Compton1000/Corbiere/Empire /Newark/Newark1000/Qube/Tribeca

Model: Ecostrad Thermostrip with Remote

Model: Available in: Sapphire Black and Glacier White. 1 Series

Installation, Operating and Servicing Instructions

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

EVP61/91/101/121. Extractor. Installation, use and maintenance.

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Consultant Specification AGILE Wireless Fire Detection System

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

MAKING MODERN LIVING POSSIBLE. CP715Si. Electronic 2-Channel Common Timebase Programmer for Heating and Hot Water. User Guide.

SUBMERSIBLE WATER PUMPS

Transcription:

Commercial Fan Heater Installation and Operating Manual Catalogue Numbers: CH06CSiRX, CH06CPiRX, CH09iRX, CH12iRX, CH15iRX. INDEX Section General Information ----------------------------------------------------------- 1 Installation & Connection Details ------------------------------------------- 2 Intelligent Fan Control -------------------------------------------------------- 3 Wireless Control ---------------------------------------------------------------- 4 Servicing & Maintenance ----------------------------------------------------- 5 Consort Equipment Products Limited Thornton Industrial Estate, Milford Haven Pembrokeshire, SA73 2RT Tel: 01646 692172 Fax: 01646 695195 Mon to Thu 8.30am to 4.30pm Fri 8.30am to 3.30pm Email: technical@consortepl.com Web: www.consortepl.com

1. General Information 1.1 Introduction This instruction manual describes the commercial fan heater range from Consort. These heaters are robustly designed for use in large open areas. With a maximum heat throw of up to 11m, they are ideal for areas such as garages, workshops and warehouses. 1.4 Controller All commercial fan heaters are controlled via a CRX2 that can provide three levels of heat. The controller also includes a fan boost function. This controller is not supplied with the unit. Each heater is equipped with an intelligent fan control, which allows the heater to adapt to the environment by automatically adjusting the fan speed. The heater provides instant directional warmth, and also has a fan-only setting for air circulation. The heaters are wall mounted with multidirectional brackets, and must be operated with the wireless controller CRX2. 1.2 General All appliances must be installed in accordance with the regulations enforced in the country of use. These instructions must be handed to the user on completion of the installation. Installers and service engineers must be able to demonstrate competence and be suitably qualified in accordance with the regulations. To ensure continued and safe operation, it is recommended that the appliance is serviced annually. The commercial fan heater slots must not be obstructed during use. 1.3 Electrical Supply The unit must be wired in accordance with IEE regulations for the Electrical Equipment of Buildings, and the installer should ensure that a suitable isolating switch is connected in the mains supply. Electrical supply for the CH06CSiRX model is 240V single phase, neutral and earth. Electrical supply for the CH06CPiRX and CH09iRX/12iRX models is either 240V single phase, or 415V three phase, neutral and earth. Electrical supply for the CH15iRX model is 415V three phase, neutral and earth. The `RX` models will not work without the controller. The controller is not supplied with the heater. 1.5 Clearance Distances It is recommended that there is a minimum clearance of 200mm between the upper surface of the heater and the ceiling surface. The unit should be fitted between 2.5m and 3m from the ground (CH06CSiRX/CPiRX) or between 2.5m and 4m (CH09iRX/12iRX/15iRX). The unit should be positioned so that the airflow is not obstructed. Never install heaters opposite to each other. 1.6 Health and Safety Sole liability rests with the installer to ensure that all site safety procedures are adhered to during installation. Sole liability rests with the installer to ensure that protective safety wear such as hand, eye, ear and head protection is used during installation of the product. Do not rest anything, especially ladders, against the product. 1.7 Standards Units conform to the European electrical standard BS EN 60335-2-30 and 2009/125/EC Directive.

2. Installation & Connection Details 2.1 Mounting Fig. 1: CH06 Dimensions Ensure that the heater is fixed on a secure wall, within the mounting height limits stated in clearance distances. Mount the heater as shown in figures 1 and 2. The angle of the heater can be adjusted in steps, 45 deg. vertically and 180 deg. horizontally. The weight of the CH06CSiRX/CPiRX models is 11.5kg, and the weight of the CH09iRX/12iRX/15iRX models is 14kg. 2.2 Electrical Connections (CH06CSiRX): The heater is suitable for connection to 230-240 Volts single phase 50Hz supply. The heater consumes approximately 6kW on the full heat setting. The maximum current draw is 25A. (CH06CPiRX, CH09iRX/12iRX/15iRX): The heater is suitable for connection to a 400-415 volt 3 phase 50Hz supply. With modification the CH06CPiRX and CH09iRX/12iRX units can also be connected on a 230-240 volt 50Hz supply. The maximum current draw for the 06CPiRX/09iRX/12iRX models are 25A, 37.5A and 50A for single phase, and approximately 8.3A, 12.5A and 16.6A per phase for a three phase connection respectively. Fig. 2: CH09/12/15 Dimensions The maximum current draw for the CH15iRX model is approximately 20.8A per phase. For 230-240 volt single phase operation, link terminals L1, L2 and L3 on the main input terminal block and connect the supply to L. The heater consumes approximately 6kW, 9kW, 12kW or 15kW (CH06CPiRX, CH09iRX / 12iRX / 15iRX models respectively) on the full heat setting. Earth terminals are adjacent to the terminal block and are clearly marked with the symbol. For safety reasons a good earth connection must ALWAYS be made to the heater. There is a wireless receiver box pre wired to the heaters see section 4 for more information.

2. Installation & Connection Details 2.3 Installation It is the sole responsibility of the installer to ensure that the points of attachment to the building are sound. Consultation with the consultant/architect or owner of the building is recommended to ensure that a sound, mechanically stable installation is achieved. Fig. 3: Swivel Bracket Assembly Before fitting or wiring the heater, ensure that the casing faces as shown on the picture, and follow these installation guidance notes. The wall bracket is secured to one of the inner cardboard box corners. Cut the plastic bag to remove it. All fixing screws, are located in the box. The heater must always be installed horizontally, using the mounting bracket provided. This ensures correct positioning and adequate clearance. Assemble the swivel bracket as shown on Fig.3. Use M8 and M5 bolts with locknuts and washers as supplied in a bag. Attach the assembled bracket to the bottom of the heater by using 4 x M6 bolts with plain and spring washers as shown on Fig.3. Secure the wall bracket to the wall with suitable fixings. Ensure the position of this bracket will allow suitable clearances between the heater, when fitted, and adjacent walls. Minimum of 3 fixings must be used to secure the wall bracket to the wall. Attach the heater to the wall bracket. Finally, adjust the direction of the heater to the desired area and tighten up all clamping nuts and bolts. 3. Intelligent Fan Control The intelligent fan control incorporates one of the latest low energy consumption EC motors. This allows the heater to operate quietly, whilst still providing the best possible levels of comfort. The intelligent fan control is only activated when the heat is switched on. If the heater is running in fan/ boost mode only (heat switched off), then the fan will operate at a fixed speed. When activated, the intelligent fan control detects the temperature of the room. Depending on which heat mode is activated, it will calculate the best possible airflow temperature and will adjust the fan speed accordingly. NOTE: When turning the heater on, or changing heat mode or fan speed mode, the fan will respond accordingly after a small time delay.

4. Wireless Receiver 4.1 Choosing a Location The heater come pre-wired to the wireless receiver RXREC. The RXREC wireless receiver can be positioned near the heater or in any other convenient place. Care should be taken when choosing a position to avoid places where there would be metal objects between the RXREC and CRX2. The RXREC should be positioned the way that the status light is visible to the user 4.2 Installation The RXREC is supplied with two metal wall brackets. The brackets have to be attached to the back of the main box as shown on the picture below. Use the screws supplied. Once the wall brackets are attached, the unit is ready to be screwed to the wall. Use 4 suitable wall plugs and screws. 4.3 Pairing to the Controller. Power up the CRX2 (see section Power options in CRX2 user instructions for details). Set heater into pairing mode as follows: 1. Locate the RXREC status light. 2. Turn power to the heater ON. Count 4 seconds, or count 4 red flashes of the status light on the heater. Turn power OFF. 3. Turn power back ON. The heater status light should be flashing green. (If the light is solid green, the 4 seconds timing was incorrect. Repeat step 1.) 4. The heater is now ready for pairing with CRX2. This has to be done within 30 seconds. After 30 seconds, the heater will return to normal operating mode. Set CRX2 into pairing mode as follows: 1. Touch and hold and icons together for 5 seconds. 2. The display will show CRX2 identification code. 3. Tap the button while the light on the heater is flashing green. If the pairing was successful, the light will stop flashing and the heater is paired with CRX2. 4.4 Status Light Light colour 4.4 Mode Selection. Heater status STAND-BY No heat output Reduced heat output Full power heat output Heater is ready for pairing with CRX FAULT - Overheating FAULT - Connection with CRX lost FAULT - Connection with CRX lost The CRX controller will come factory set in temperature control mode. This can be changed to manual/ timer mode. In this mode, the temperature control is disabled and the controller doesn t have to be installed in the same location as the heaters. To switch to manual mode, touch and hold the and & icons for 5 seconds to access the setup menu. Use icon to navigate through the menu. Navigate to option 6, and change the value to 2, this will change your controller to manual/timer mode. MANUAL MODE : In manual mode the CRX still has the 4 operating Features, Boost, Manual, setback, and programme. Each feature can be selected by activating the CRX2 and tapping to cycle through the options. MANUAL Use the & button to choose required heat setting. By tapping will enable fan boost. F - fan speed F0 = heater OFF, F1 = fan normal speed, F2 = fan boost H - heat output H1 = heat 1, H2 = heat 2, H3 = heat 3 On heaters with only two heat setting H1 and H2 are half heat. BOOST MODE: F2 H3 setting - The heater is running at maximum speed and full heat PROG MODE: In this mode, the CRX2 will follow the week s time / fan, heat setting programme. The fan speed and heat setting can be set for induvial time periods. Follow CRX2 instructions on how to set 7-day programme.

5. Servicing & Maintenance 5.1 Maintenance 5.3 Thermal and Fault Protection ALWAYS ENSURE THAT THE MAIN EXTERNAL ELECTRICITY SUPPLY IS SWITCHED OFF BEFORE COM- MENCING ANY MAINTENANCE ON THIS HEATER. To obtain the best results from the heater, it is essential to avoid the accumulation of dust and dirt within the unit on the air inlet and discharge grilles. For this reason regular cleaning is necessary, paying particular attention to the removal of dirt build up on the rotor blades. Cleaning of the fan is best carried out with a soft brush. The product should be serviced annually. Servicing shall be undertaken by a competent person. The units are protected from overheating in the event of fan failure or an obstruction of the free airflow, by two thermal cut outs. If this happens the thermal cut outs effectively switch off the appliance. The appliance will not operate until the thermal cut outs are manually re -set. This should be done by a competent electrician. 5.4 Resetting Thermal Cut-Out The cut-outs are located under the top cover on the top of the heating element. a) To reset the cut-out, allow the appliance to cool for 20 minutes. b) Gently press the plastic square button on the top of the cut-out. c) Restart, switch ON the appliance. 5.2 General If the Fan Heater does not operate after switching on, then a suitably competent service engineer should be called to identify the nature of the fault. If the heater will not operate, disconnect it from the mains and arrange for a certified electrician to attend to investigate the reason. Note: The manufacturer operates a service function from the address provided in these instructions. 5.5 Spares It is essential when ordering spares or replacement parts to state the model number and the serial number. NB: DO NOT COVER ANY OF THE AIR INLET OR OUTLET GRILLES AT ANY TIME. In the interest of progress the Company reserves the right to vary specifications from time to time without notice. The material listed is offered subject to the Company s General Conditions of Sale, a copy of which can be obtained on request. Other faults in relation to the element, motor and wiring should be identified using conventional fault finding techniques. In the event that electrical components are replaced, please ensure that electrical safety checks in accordance with the regulations in force in the country of use are undertaken. Consort Equipment Products Ltd Registered Office: Thornton Industrial Estate Milford Haven, Pembrokeshire, SA73 2RT Tel: 01646 692172 Fax: 01646 695195 Email: technical@consortepl.com BS EN ISO 9001 Registered Company No FM12671

CH06CSiRX Wiring Diagram

CH06CPiRX Wiring Diagram

CH09iRX/12iRX/15iRX Wiring Diagram