Automatic Waste Water Lifting Unit. Ama-Drainer-Box Mini. Type Series Booklet

Similar documents
Automatic Waste Water Lifting Unit

mini-compacta Type Series Booklet

Submersible Waste Water Pump. Ama-Drainer N 301/302/ Hz. Type Series Booklet

Calio-Therm S NC/NCV Type Series Booklet

Submersible Waste Water Pump. Ama-Drainer N 301/302/303/358. Type Series Booklet

Vertical Ring-section Pump WKTB. Type Series Booklet

50 Hz. Submersible Waste Water Pumps

Cleaning System. Amajet. Type Series Booklet

Lifting Plants Product Overview

Sekamatik series PREFABRICATED LIFTING STATIONS FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATIONS

Building Services. KSB Building Services. A Real Welcome Home.

Technical data. Unilift KP. CRUNDFOS "~ ozpump.com.au Drainage pumps. Unilift KP

TYPE POS Oil Shield Sump Pump

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

JUNG PUMPEN LIFTING STATIONS

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

MULTISAN Fully automatic sewage and waste water pump

FEATURES. Other Fed-Flush Arrangements

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

LS Condensate Removal Pump Installation, Operation and Service Instructions

DRAINAGE AND SEWAGE. DRENA-LINE Residential Technology

Trusted Expertise in Domestic and Commercial Wastewater

Gira nurse call system Installation, start-up, operation. Gira emergency set

Data sheet: Wilo-RainSystem AF Comfort MC 304

Instruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data

LEAKSTOPPER 1 Single zone water leak detection system

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

GRUNDFOS PRODUCT GUIDE. Unilift CC, KP, AP. Submersible wastewater pumps 60 Hz

SL S.S.N.51D

X1 series Submersible Drainage Pump

Alarm Switchgear AS1-M

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

AlertMaxx2. Installation & Operating Manual. Ground Water (DMS-298) Pump Station High Level Alarm

LEAKSTOPPER RANGE Multizone water leak detection systems

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

Model Number Structure

The easy solution for waste water removal

NEWS 2017 SANIFLO. Pumps and pumping stations

INSTALLATION AND OPERATING INSTRUCTIONS

POWER and INTELLIGENCE

SL EX.4.51D

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

Stancor Duplex Oil-Minder System Submittal SE Volt Single Phase Duplex SE-100 Pumps with Floats and Oil-Minder Probe

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

SUPPLEMENTARY INSTRUCTIONS

Instruction Manual. Electronic gas and smoke detector GRM

MANUAL Oil Level Sensor

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

CRU 200 and 500 Series Condensate Recovery Units

Choosing the Right Pump

Dräger Polytron 5720 IR Toxic Gas Detection

KSB mechanical seals for water and waste water applications

Process engineering. Collection and disposal of commercial food waste ACO Waste-Jet Wet refuse collection system

ELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description

INFO 3/2015. NEWS WC connectors Bronze program Industrial stainless steel drainage system Swimming pool overflow radius gratings.

WISY. Rainwater Harvesting. Installation and Operating Instructions. English. instructions for the. rainwater units. these installation

SECTION HEATING BOILER FEEDWATER EQUIPMENT

USER MANUAL TUNGSTEN SMART-HEAT ELECTRIC WIRELESS DIMMER CONTROLLER BY BROMIC IMPORTANT

2016 Plumbing Supplemental Plan Review List

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Operating instructions. Emergency system set. Ref.-No.: NRS Safety instructions. 2. System overview

USER S MANUAL DN-2. Drain pump

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

DiMM Unit. LST Digital Interface Monitor Module (LST-DiMM) MAN3109

USER MANUAL TUNGSTEN SMART-HEAT ELECTRIC WIRELESS DIMMER CONTROLLER BY BROMIC IMPORTANT

OPTISENS TUR 2000 Technical Datasheet

DATASHEET. Burner control unit FDA 601x

This guide will discuss the scope of work, and technical requirements of connecting to the Energy Transfer Station(s) (herein referred to as ETS).

Conductivity Electrode LRG Original Installation Instructions English

Protecting you and your home

VDS2510 Installation Manual

TECHNICAL SPECIFICATION

Installation instructions Danfoss heat pump DHP-R

Danfoss gas detection units

Micro/Ultra Filtration System StamoClean CAT 430

NIBE SPLIT ACVM 270 Air/water heat pump

Installation and application. Leakage detectors, CLS/FLS/FLS10/MiniCAS II

RQE Series Temperature Controllers

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

Submersible Pumps. New Style Submersible Pumps. With closed-loop cooling system. Non-Clogging Type CNX Series

CI/SfB (57.7) 2nd edition. Lo-Carbon Quadra

CENTRIFUGAL CEILING EXTRACT FAN

8.0 Table of Contents. Monitoring system WIREM

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

GUIDE SPECIFICATIONS AQUARIUS ii

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz

grundfos SEG AUTOadapt The perfect grinder pump for wastewater transport be think innovate

XP95 Sounder VAD Base

XC10 Extinguishing control panels

Dräger Polytron 8720 IR Detection of carbon dioxide

NON-SUBMERSIBLE WATER PUMP

Transcription:

Automatic Waste Water Lifting Unit Type Series Booklet

Legal information/copyright Type Series Booklet KSB Aktiengesellschaft Pegnitz All rights reserved. Contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without KSB s express written consent. Subject to technical modification without prior notice. KSB Aktiengesellschaft Frankenthal

Contents Contents Building Services: Drainage... 4... 4... 4 Main applications... 4 Fluids handled... 4 Operating data... 4 Designation... 4 Design details... 4 Materials... 4 Product benefits... 5 Certification... 5 Technical data... 5 Characteristic curve... 5 Connections... 6 Dimensions... 7 Installation example... 7 Scope of supply... 8 Accessories... 8 3

Building Services: Drainage Building Services: Drainage Designation Example: C Key to the designation Code Ama-Drainer-Box Mini C Description Type series Small waste water lifting unit Variant for aggressive fluids Design details Design Collecting tank made of impact-resistant plastic, for floor or wall mounting Odour-proof cover with activated carbon filter and integrated overflow protection Submersible motor pump which starts and stops automatically, with special float Integrated swing check valve To EN 12050-2 Type of installation Stationary above-floor installation Connections Inlet DN 50/ DN 40/ DN 32 Discharge outlet DN 40 Shower connection DN 50 Main applications Single-pump units: above-floor box Mini Automatic drainage of washbasins, showers, washing machines, dishwashers, etc. DN 40 spigot and socket connection can be fitted at the site for venting Drive Single-phase a.c. motor Integrated temperature switch With cable and shock-proof plug Fluids handled Impeller type Standard variant Slightly contaminated water Open multi-vane impeller, free passage of 10 mm Variant C Variant C Material variant for aggressive waste water Aggressive fluids is not suitable for sewage from urinals and toilets. For these applications, please use our minicompacta sewage lifting units. Materials Overview of available materials Operating data Operating data Characteristic Flow rate Head Temperature of fluid pumped Q up to 10 m3/h (2.8 l/s) H up to 6.5 m t up to 35 C1) Component Collecting tank Pump Polypropylene See description for Ama-Drainer N 301 (C) 1) Up to 3 minutes for waste water from the hot water cycle of washing machines and dishwashers for non-industrial use. 4

Building Services: Drainage Product benefits Impact-resistant plastic collecting tank Ready-to-connect, easy installation and commissioning Integrated swing check valve Shower connection as standard Certification Certification Effective in: Comment Europe All sizes Technical data Selection table Ama-Drainer-Box Submersible waste water pumps Mat. No. [kg] With Ama-Drainer N P 1 P 2 50 Hz 1~230 V Power cable H07RN-FG [kw] [kw] I N [A] [m] [mm 2 ] Mini 2) 301 SE 0.43 0.18 1.9 3 3 x 0.75 29131770 9 Mini C 2) 301 SE/C 0.43 0.18 1.9 3 3 x 0.75 29131771 9 Characteristic curve 8 0 US.gpm 50 0 20 IM.gpm 40 5 20 H [m] [ft] N 301 5 0 0 5 Q [m 3 /h] 10 15 0 2 [l/s] 4 2) Supplied fully assembled ex works 5

Building Services: Drainage Connections 3 4 1 7 5 2 6 Connections Connections Connection Description Inlet / discharge outlet 1+2 Socket DN 50, horizontal optional for inlet with special pipe part DN 50/ DN 40/ DN 32 for discharge outlet special pipe part DN 40 Inlet 3 Socket DN 50, vertical for inlet with special pipe part DN 50/ DN 40/ DN 32 Connection to washing machine possible via Y-drain pipe Auxiliary connections Cable gland 4 Cable grommet, diameter 48 mm Shower connection 5+6 Special pipe part, outside diameter 50 mm, either right or left Venting 7 Carbon filter insert with overflow protection. Wherever possible, leading the vent pipe out of the roof is recommended (max. outside diameter 40 mm). 6

Building Services: Drainage Dimensions 75 A A 328 B 90 230 72 62 B 100 190 (1) 95 (2) 456 35 (3) 155 82 322 Dimensions [mm] (1) Cut-in level standard design (2) Cut-in level shower design (3) Cut-out level standard and shower design A Inlet / discharge outlet B Shower connection Installation example 7 6 H 1 2 3 1 4 5 Installation example 1 Inlet 2 Waste water lifting unit 3 Discharge line 4 Socket gate valve 5 Valve preventing backflow into the shower basin 6 Flood level 7 Backflow loop H Pipe loop min. 150 mm 7

Building Services: Drainage Scope of supply Small, ready-to-connect waste water lifting unit consisting of: Stable plastic collecting tank with pressure-sealed, odour-proof cover Inlet-side connections (rubber sockets) 2x DN 50/ 2x DN 40/ 1x DN 32 Discharge-side connection DN 40 (rubber socket) Shower connection DN 50 (special pipe part) Carbon filter insert with overflow protection Submersible motor pump which starts and stops automatically, with integrated swing check valve Accessories Electrical accessories Item Description M 1 alarm contactor Magnetic float switch as contactor for alarm switchgear AS 0, AS 2, AS 4 and AS 5 with 5 m connection cable Mat. No. 18040562 [kg] 0,8 Alarm switchgear Item Description Mat. No. [kg] Alarm switchgear AS 0, AS 2, AS 4 with circuit breaker, piezoceramic signal transmitter, 85 db(a) at a distance of 1 m and 4.1 khz, green equipment-on lamp Plastic housing IP 20, 140 x 80 x 57 mm; use float switch, F 1 moisture sensor (item E 64), M1 alarm contactor, or signal relay of control unit as contactor. E 50 AS 0 mains-dependent 29128401 0,5 29128422 0,5 E 51 AS 2 mains-dependent with volt-free signalling contact E 52 E 53 E 55 AS 4 mains-independent with volt-free signalling contact/battery buffer and selfcharging power supply unit (for 5 hours' operation in the event of power failure) Alarm switchgear AS 5 Mains-independent, with self-charging power supply unit for 10 hours' operation in the event of power failure, mains pilot LED, fault indicator light, horn-off push button, volt-free contact for hook-up to a control station, ready for connection with 1.8 m cable and plug. ISO housing IP 41, 190 x 165 x 75 mm, use float switch (E 60) or signal relay of control unit as contactor Alarm equipment (e.g. horn) E 70 230 V ~/ 12 V = 5 VA Alarm switchgear AS 1 in ISO plug housing IP 30, mains-independent, with self-charging power supply unit for 5 hours operation in the event of a power failure, acoustic signal 70 db(a) with circuit breaker and integrated signal transmitter with 3-metre connection cable, max. 60 C, not suitable for steam and condensate. Alarm transmission options: Water alarm signal at a water level of only 1 mm (!), by placing the contactor on the floor of rooms subject to a flooding risk, e.g. the cellar or next to the washing machine in the kitchen or bathroom. 230 V ~/ 9 V = 1,5 VA 8 29128442 0,5 00530561 1,7 00533740 0,9

Building Services: Drainage Item Description Mat. No. [kg] E 64 Moisture sensor F 1 19072366 0,2 E70 As contactor for AS 0, AS 2 or AS 4 alarm switchgear or LevelControl, with 3-metre connection cable, 40 C max., not suitable for steam and condensate. Possible applications for alarm transmission: - Water alert signal at a water level of just 1 mm (!) by placing the contactor on the floor of rooms subject to a flooding risk, e.g. the cellar or next to the washing machine in the kitchen or bathroom. Horn, 12 V DC, 105 db(a), 1.2 W For indoor and outdoor installation, to be mounted in a position where it is protected from direct rain, IP 54 enclosure 01086547 0,1 E 330 KSB washing machine interrupter Alarm triggered, with automatic interruption of power supply to the washing machine if the water level in the collecting tank is too high 230 V AC, 50/60 Hz, max. 16 A ohm resistive load Includes: Housing with socket and plug Buzzer Automatic re-start M 1 K contactor with 5-metre connection cable 01318215 0,279 9

KSB Aktiengesellschaft 67225 Frankenthal Johann-Klein-Str. 9 67227 Frankenthal (Germany) Tel. +49 6233 86-0 Fax +49 6233 86-3401 www.ksb.com 2336.52/01-EN 24.04.2012