DigiTemp. Digital Water Tempering System. PVI.com

Similar documents
ADMS. AERCO Digital Mixing Station. AERCO.com

IntelliStation. The Smart Mixing & Recirculation System. For Domestic Hot Water in Commercial and Institutional Facilities. PowersControls.

Submittal S-NV-150-LF-M November, 2018 MEGATRON MODEL NV-150-LF DIGITAL TEMPERATURE CONTROL STATION

Submittal S-NV-200-LF-M DIGITAL TEMPERATURE CONTROL STATION. Valve assembly is ASSE 1017 Certified. Valve assembly is cupc Certified

COBREX. Semi-Instantaneous. Steam-Fired Domestic Hot Water Generator. Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty. PVI.

EZ Plate Instantaneous

5 (34) 10 (69) 45 (170) 64 (242) 65 (246) 92 (348) 90 (341) 127 (481) 85 (322) (227) 80 (303) 113 (428) 148 (560) 105 (397) 141 (534) 100 (379)

DIGITAL-FLO SEMI-INSTANTANEOUS VERTICAL HOT WATER

HL45, HL80 Thermostatic High-Low Valves

Circuit SolverTM THERMOSTATIC RECIRCULATION VALVE FOR DOMESTIC HOT WATER SYSTEMS.

Model SFMV Series. Lead-Free Supply Fixtures Based On The MV17 Master Mixing Valves

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

ENGINEERED DUPLEX ALLOY

INDIRECT FIRED EQUIPMENT INSTALLATION FORM

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

SECTION DOMESTIC WATER PIPING SPECIALTIES

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

WATER HEATING & WATER TEMPERATURE CONTROL DIGITAL & FEED-FORWARD

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

Automatic Temperature Controller (ATC)

POWER VTX. Condensing Storage Water Heater. 500 to 1000 MBH 225 Gallon Tank 15-year Warranty. PVI.com ENGINEERED DUPLEX ALLOY

TMV45 & TMV80 Standard Thermostatic Mixing Valves

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

water source / fan coils

earth safe Fuel Systems for Critical Power

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

HIGH EFFICIENCY COMMERCIAL BOILERS

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

Domestic Hot Water Systems and Plumbing Products

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ONQUEST. Featuring... Condensing Water Heater. Requires no tank linings or heat exchanger linings. Requires no anodes of any type. 10- year warranty.

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

Portable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions

Better Design, Better Control, Better Systems.

Project Name: Location: Engineer: Contractor: I. GENERAL

AM Series Proportional Thermostatic Mixing Valve

CONDENSING HIGH EFFICIENCY BOILERS

Pressure Steam Humidifiers LS SERIES. humidity.com

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages

DIGITAL HOT WATER SOLUTIONS

The water heater evolved. Hot water. Perfected.

Wilo CO-Helix Booster Systems. Product Presentation July, 2017

CL44eN-BAS DISHWASHER

CLPS86eN-BAS DISHWASHER

Pressure Steam Humidifiers. Designed to deliver reliable humidity from facility steam boilers. Live Steam

Portable C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

Fingertip control, optimum efficiency, total comfort and clear reporting. warmafloor.co.uk

Hubbell NX500 High Efficiency Gas Condensing Water Heater

AM SELECT DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES VOLTAGE. Item # Quantity C.S.I. Section AM15

Nu/Clean AquaBatch XL The Batch Cleaner with the HIGHEST TEMPERATURE PROCESS & the added cleaning power of STEAM!

VENTLESS DOOR-TYPE DISHWASHER

LightSweep. Lighting Control System

Hydronic & HVAC Control Systems

DAP III Zone Master User s Guide

Sequence of operation

A Better Boiler Just Got Better. Better Boilers. New Size Available. Express Setup. Load Status. User Setup. Installer Setup. Diagnostics.

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION MEGATRON MODEL 10NB-LF 4 HOT & COLD INLETS 4 MIXED OUTLET 2 RETURN PIPING

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Med Touch Master Alarm

Taco 00 Series Cartridge Circulators

Document # R01

CL64eN-BAS DISHWASHER

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

Honeywell Water Solutions. Thermostatic Mixing Valves

Thermostatic mixing valves with interchangeable cartridges

ASSE 1017 Point of Source Commercial. Mixing Valves. Mixing Valves. MVA (34A) Series/MVAH Hydronic Series

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

Temperature Controllers

Date: Project #: Engineer: Prepared By: Bid Date:

WATER CONTROL VALVES

Intelligent System Solutions Steam Air Hot Water

AM Rapid Recovery Water Heaters

Automatic Circulating Water Heaters

Home. One Source For All Your Potable Water Needs

Heat Transfer Packages

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

95% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS REMOTE CONNECT CAPABLE CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages

OUTLET HOT INLET COLD INLET INSTALLATION

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Multiview Monitor / Controller

BOILER APPLICATION GUIDE for:

Carbon Monoxide Transmitter

Cultivator & Hybrid Cultivator

DIGITAL SHOWER SYSTEM

Packaged Semi-Instantaneous Steam Fired Water Heater

MEGATRON MODEL 2, 3, 4, and 5

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

AM SERIES BOILER INSTALLATION FORM

SAFETY SHOWERS AND EYEWASHES 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

Transcription:

DigiTemp Digital Water Tempering System PVI.com

DigiTemp Digital Water Tempering System DigiTemp is a domestic hot water main mixing station for commercial and institutional facilities that intelligently controls and monitors the water recirculation loop. It provides precisely controlled water temperature regulation within ± 2 F to ASSE 1017, even during low and zero demand periods. When paired with a PVI water heater, DigiTemp creates a safe system that helps maintain the appropriate water temperature you select for your facility. It delivers consistent hot water on demand wherever and whenever it is needed, in accordance with building codes. It also supports energy conservation through more efficient water temperature management and in turn reduces energy costs for greater savings. Mixed Water Outlet Building Return Return-line temperature and pressure sensors Mixed-line temperature and pressure sensors Electronic controller with 3-1/2" color touchscreen High-speed mixing valve actuator provides temperature accuracy to within ± 2 F in accordance with ASSE 1017 Internal capacitor re-positions valve to full cold port in the event of a power loss. DigiTemp is not reliant on batteries Hot-line temperature and pressure sensors Cold-line temperature and pressure sensors Monitors and displays: Hot supply temperature and pressure Mixed outlet temperature and pressure Mixed outlet set point Return loop temperature and pressure Mixed and return flow and energy use (optional) Read-write and alarm via BAS Return Connection to Water Heater Cold Water Inlet Hot Water Inlet 1

Features and Operation Features Configurable on location; does not require factory pre-programming or special software and laptop Controls water temperature to ± 2 F in accordance with ASSE 1017 Control ± 2 F during periods of low/zero demand In case of power or cold water failure, valve flows full cold for safety with manual override feature to set mixed outlet temperature Settings can be adjusted/monitored at the controller or remotely through BAS (Building Automation System) 3.5" full-color, user-selectable touch screen display User programmable high-temperature sanitization mode Displays pressure, temperature and flow/btu data Pass code protected for security User programmable high temperature alarm NSF 372 compliant Five-year warranty System Operation with Smart Controller DigiTemp maintains the recirculation loop temperature by energizing a field-supplied pump when loop temperature drops below a specified return limit and de-energizes the pump when proper loop temperature is re-established. Its touchscreen control operates a 3-way valve through a high-speed actuator to precisely maintain the selected outlet temperature. Temperature and pressure sensors are included at key points within the panel to enable an immediate response to changes in fixture demand and supply water conditions. A Sanitization Mode allows buildings with a thermal eradication protocol in place to control water-borne bacteria to deliver a higher water temperature for a pre-set duration to allow building maintenance staff sufficient time to open all of the fixtures. DigiTemp can be connected to a building automation system (BAS) to provide read access to a range of temperature and pressure measurements and allow adjustment of the outlet temperature setting within a pre-programmed range. BACnet IP, BACnet MSTP and Modbus protocols are all supported. Alert contact relays are included to aid in remote notifications. 2

Typical Application: Single-Temperature Tempering 120 F to the building MIXED-TEMPERATURE FIXTURES MIXED TEMPERATURE OUTLET RECIRCULATION PUMP (SUPPLIED BY OTHERS) 140 F from the heaters Check Valve Ball Valve Union HOT INLET BUILDING RETURN TO THE WATER HEATERS HEAT TRAP COLD INLET EXPANSION TANK COLD WATER MAKEUP Illustrations are for concept only. Refer to manuals for complete piping details. 3

Typical Application: Dual-Temperature System with Tempering HIGH-TEMPERATURE FIXTURES MIXED-TEMPERATURE FIXTURES RECIRCULATION PUMP (SUPPLIED BY OTHERS) 120 F MIXED TEMPERATURE OUTLET RECIRCULATION PUMP (SUPPLIED BY OTHERS) 140 F Check Valve Ball Valve Union HOT INLET COLD INLET HEAT TRAP EXPANSION TANK COLD WATER MAKEUP Illustrations are for concept only. Refer to manuals for complete piping details. 4

Specifications and Capacity Specifications* Max Operating Pressure... 200 psi (1379 kpa) Max Hot Water Temp.... 200 F (93 C) Min Hot Water Supply Temp.... 2 F (1 C) above set pt Hot Water Inlet Temp. Range...120-180 F (49-82 C) Cold Water Inlet Range... 39-80 F (4-27 C) Min Flow... 0.5 gpm (1.89 lpm) Temp. Adjustment Range... 80-180 F (27-82 C) Listing /Compliance... ASSE 1017, cupc, NSF, CSA 24/UL873 *Refer to manual for complete details E365015 Temp. Ind. and Reg. Equip. Capacity Flow Capacity at 50-50 Mixed Ratio Pressure Drop Across Valve 5 Model Valve Configuration Min. System Draw CV V85 1.5" Single Valve 0.5 gpm 26.88 V135 2 Single Valve 0.5 gpm 42.70 V85-2 1.5 Dual Valve 0.5 gpm 53.57 V135-2 2 Dual Valve 0.5 gpm 85.27 5psi (34 kpa) 10psi (69 kpa) 20psi (138 kpa) 30psi (207 kpa) 60 gpm 227 lpm 96 gpm 363 lpm 120 gpm 454 lpm 192 gpm 727 lpm 85 gpm 322 lpm 135 gpm 511 lpm 170 gpm 644 lpm 270 gpm 1022 lpm 120 gpm 454 lpm 191 gpm 723 lpm 240 gpm 908 lpm 382 gpm 1446 lpm 147 gpm 556 lpm 234 gpm 886 lpm 294 gpm 1113 lpm 468 gpm 1772 lpm

Ordering Information Standard Capacity - Single Valve Valve Inlets (in) Outlet (in) Order Code V85 2 (50mm) 2 1/2 (63mm) V85-1 V135 2 1/2 (63mm) 3 (75mm) V135-1 Return Pipe Size 1 A 2 B Flow/BTU Package None Flow/BTU Package Strainers* None On inlets X F XNP SNP *Strainers ship loose and must be installed by a plumber at the job site High Capacity - Dual Valve Valve Inlets Outlet Order Code V85 4 (100mm) 4 (100mm) V85-2 V135 6 (150mm) 6 (150mm) V135-2 Return Pipe Size 3 C Flow/BTU Package None Flow/BTU Package Strainers None On inlets X F XNP SNP 6

T: (817) 335-9531 Toll Free: (800) 784-8326 PVI.com PV 8719 5-2017 2017 PVI