Conventional & Twin-wire Fire System

Similar documents
Reliably Advanced Extinguishing Control

Reliably Advanced Extinguishing Control

Excel-EN Conventional Fire Control Panel

The EN54 Part 2 and 4 Fire System

The EN54 Part 2 & 4 Fire System

Engineer Paging. Staff Paging. Deaf Alert.

Intelligent Security & Fire Ltd

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

The EN54 Part 2, 4 and 13 Fire System

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Intelligent Security & Fire Ltd

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

Components Brochure DX CONNEXION

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

DXc Control Panels. DXc1. DXc2. DXc4. Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D)

Advanced FireAlarm Panel 1-4Loop

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

Installation, Operating and Maintenance Manual

OPERATION AND INSTALLATION MANUAL

Australia s Advanced Fire System

ZXSe Range Data Sheet

Panel Functions & Indicators - Key to Icons General & Zone Fire LEDs ACCEPT SOUNDERS START/ STOP RESET BUZZER MUTE KEYSWITCH DELAY ON/OFF ITEM SELECT

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

General Routing Interface

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

An introduction to... Sigma

System 800 Addressable Fire Detection & Alarm System

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

909e Series 2/4 Zone Panel. Operating and Configuration. Manual Version V01

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Application, Installation, Operation & Maintenance Manual

User Operation Manual

Conventional Fire Alarm System 2014 V1.2

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

user manual Document No , Revision 03 November 2015

Technical Data Sheet

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

The Leading Multiprotocol Intelligent Fire Panel

Surveyor Envoy-MINI 4

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

Installation, Commissioning & Operating Manual

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

DISABLED TOILET / EMERGENCY ASSISTANCE ALARMS

HART XL High Sensitivity Smoke Detection

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Operating instructions Vigilon panel and Network node Fire detection and alarm system

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Product Data Sheet. Remote Terminals. Features:

Installation, Commissioning & Operating Manual

Intelligent Single Loop Fire Alarm Control Panel

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

The Worldwide Fire System ANSI/UL 864 9th Edition

ID2000. operating manual

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Gen4 Domestic Intruder Panels RELIABLE AND FLEXIBLE INTRUDER PANELS. Domestic applications

2018 Johnson Controls. Tyco Fire & Security GmbH, Victor von Bruns-Strasse 21, 8212 Neuhausen am Rheinfall, Switzerland DUO-CEL

intelligent fire alarm ID60series panels

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

Intelligent Security & Fire Ltd

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

EMERGENCY ASSISTANCE ALARMS

Control Panel User Guide

SFC-200 SERIES LED FIRE ALARM PANEL

RP1r-Supra / VSN-RP1r+ / ESS-RP1r-Supra Extinguishing Control Panel User Manual. HLSI-MN-103I v.06 September 2017

SOUNDER CONTROL MODULE SCM-AS4

USER MANUAL & MAINTENANCE GUIDE OG OO

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

ZSC100 Gas Detection and Alarm System Controller

Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

NFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual

SALES SUPPORT DOCUMENT

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

SECURIT 700L PLUS ENGINEERING MANUAL

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

Document No Issue 4 user manual

HART XL High Sensitivity Smoke Detection

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

Why Hart XL Aspirating Smoke Detection?

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

HS-5100, HS-5200, HS-5400 ANALOGUE ADDRESSABLE CONTROL PANELS. User Manual. Approved Document UI-ELAN-02 Revision 03

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Menvier Fire System MF9300

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

Saxon Range 1-8 Zone Convertional Control Panels

FIRE DETECTOR TYPE ED816 ZONE 5 ZONE 4 ZONE 6 ZONE 7 FIRE FIRE FIRE FIRE FAULT FAULT FAULT FAULT DISABLED DISABLED DISABLED DISABLED OFF OFF OFF OFF

Different types of Fire Alarm System

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

TrueAlarm Fire Alarm Controls

Control Panel User Guide

Transcription:

Conventional & Twin-wire Fire System

Advanced Customer Service At Advanced we re not just famous for our fire systems. Our Advanced360 customer support, service and technical training are widely acknowledged as industry leading. The Advanced360 team works hard to ensure you fi nd an Advanced system easy to specify, install, confi gure and maintain, no matter how demanding your installation. It s another reason why we set The Standard in Fire Systems. UK Tel: +44 (0)1670 707 111 Dubai Tel: +971 4 299 0908 Email: sales@advancedco.com Web: www.advancedco.com

Contents About Advanced 3 QuickZone & QuickZone XL 4 Panel Overview 5 False Alarm Management 6 Programming Features 6 AdSpecials 7 QuickZone Product List 7 About Advanced Manufacturing and Quality Admin Customer Service and Support R&D Advanced is known all over the world for making the highest quality, best performing fire systems. We design easy into our products. We make it easy to set up a one panel system or a complicated 200 panel network and we make our software intuitive. We deliver fast, accessible support, training and service. Above all, we make it easy to rely on Advanced. Fire Systems are in our DNA. The people that started Advanced are the people that spearheaded the intelligent fire systems industry. They still work at Advanced and we train talented engineers and technologists every year. Over 25% of our business is dedicated to R&D. Our knowledge is unmatched, anywhere in the world and we re determined to keep it there. Our systems are protecting people and property in over 60 countries worldwide, in many of the most prestigious and challenging locations. We realise our growth comes from strong customer relationships. We stay friendly, flexible and reactive to your requirements and our customer service is consistently rated excellent. We manufacture all of our panels in the UK to demanding quality standards and hold global approvals. We enjoy full ISO 9001 compliance across manufacturing and design. 3

The Advanced Conventional and Twin-wire Fire System. QuickZone and QuickZone XL fire panels support 2-32 zones, are approved to EN54-2&4 and deliver a host of performance, configuration and programming features. A QuickZone system, as the name suggests is quick and simple to install and manage. QuickZone s standard and XL panel formats allow absolutely the best solution to be selected and make it ideal for any installation where a conventional panel is required. Quick on the Wall Sturdy metal enclosure Multiple knockouts Easy-change PCBs Ample space for wiring Integral, switch mode, 1.25/2.5/5.0 Amp PSU Quick to Configure Up to 32 Fire zones DIL switch selection of twin-wire /conventional format 2 open collector outputs 2 volt-free contacts 28V output Zone interface function allows last zone to be set via DIL for non-latching operation Simple access to batteries Metal earth bar (no crimping) No end-of-line modules required Compatible with a wide range of conventional detectors 2 inputs (class change and alert) Up to 6 sounder circuits Spare zones can be used as sounder circuits Common fire output and relay can be programmed to cancel on silence Modular expansion zone cards available XL system includes repeater panel Quick to Maintain Simple, clear LED indication of Fire, system status and zone status One-button fault diagnosis Colour coded keypad to manage Resound, Silence, Reset, Test, Disable, Mute and Test Lamps Simple 3 level programming accessible by keyswitch or keycode and DIL Disablements removed with one code Factory reset option 3 button action to disable zones Buzzer mute in Fault condition In test mode, tests can be run with or without sounders False alarm management 40 event log (XL only) Full, industry leading technical support from Advanced 3 year warranty 4

Panel Overview Advanced s QuickZone solution offers eight panels across two product lines that allows installers to specify the system that matches their performance and price requirements. QuickZone is the most straightforward panel in the range and is appropriate for quick, simpler installations. QuickZone XL is a feature rich panel that can support passive or fully functional repeaters and is ideal for larger conventional/twin-wire installations with more involved programming and configuration requirements. 2 or 4 zones DIL selectable conventional or twin-wire (sav-wire) set up Class change and alert inputs Fire and fault relays 2 monitored sounder circuits 1.25 Amp switch mode PSU Space for up to 3.2Ah batteries False alarm management Approved to EN54-2&4 3 year warranty 4-12/16-32 zone options DIL selectable conventional or twin-wire (sav-wire) set up per zone Integral 2.5/5 Amp switch mode PSU Up to 7/18 Ah batteries Class change and alert programmable inputs Programmable relays and outputs Up to 6/4 monitored sounder circuits Integral detector removal monitoring Test mode (with and without sounders) Alarm load of 2.4A shared across all sounder outputs Modular expansion zone cards available (4-12 zone only) 2 additional sounder circuits with expansion card (4-12 zone only) False alarm management Zonal programming Programmable outputs Programmable output delays Supports up to 8 QuickZone XL Repeater panels Approved to EN54-2&4 3 year warranty Repeater Same easy-to-use controls and indications as panel Can be fully functional or passive 12 zonal fault and fire indication 1.25 Amp integral PSU Class change and alert input Test mode and disablement functions Up to 8 per main panel Approved to EN54-2&4 3 year warranty 5

False Alarm Management QuickZone false alarm management functions according to one of three different modes as described in EN54-2. QuickZone supports mode A while QuickZone XL supports all three modes. False alarm management can be selected for individual zones on both panels. Mode A: The first alarm is not indicated and the sounders do not activate. The panel resets and rechecks the zone within 15-30 seconds, if an alarm is detected the panel activates a full fire condition. Any new alarm from the same or a different zone within 30 minutes also activates a full fire condition. Mode B: The first alarm will indicate at the panel but the sounders do not activate. The panel resets and rechecks the zone within a programmable time period (1 4 minutes). If an alarm is detected the panel activates a full fire condition. Any new alarm from the same or a different zone within a second programmable time period of 5 to 30 minutes will also activate a full fire condition unless the reset button is pressed. Mode C: The first alarm will indicate at the panel but the sounders do not activate. The panel will not activate a full fire condition unless a second device is activated in the same or a different zone. Programming Features Zone Function Programming: To maximise configuration options, QuickZone allows individual zones to have specific programmed options including: Set as latching or non-latching Short circuit = Fire for monitoring Specified for MTL5061 I.S. barrier compatibility Compatible with schottky or zener diode bases False alarm management modes Set delays to outputs Silent mode for indication purposes - visual and audible alarm at panel but no sounder operation Detector removal monitoring can be turned off for older non-approved detectors (non-compliant to EN54). Twin wire zone can be programmed to zone of origin continuous ringing. Other zones can be set to pulsing, silence or continuous. Inputs: Two independent programmable inputs - class change and alert input Either or both inputs can be programmed for remote evacuation, remote silence alarm, remote reset. Inputs programmable for indication purposes so the zone 12/32 LED or fault LED will illuminate. Two additional programmable inputs (remote reset & remote silence alarms), are available on the 16-32 zone panels. Outputs: Can be set to latching Fault outputs can be inverted Aux relays and all outputs, including sounders, are independently programmable: On, off or pulsing Programmed to a dedicated zone Programmed with a custom response to silence alarm, evacuate, class change input, alert input or during zone delay. Other sounders can be switched off, pulsing or continuous Output delays can be applied to aux outputs and sounders (for example investigation delay for false alarm management). 6

Custom Built Panels and Control Units Advanced s special engineering and manufacturing team develops bespoke solutions for customers on the backbone of our market leading fire technology. From mimic panels and special enclosures to high specification control units and monitoring stations, the AdSpecials team s work is found in thousands of locations worldwide. Offering a consultancy, design and build service, the AdSpecials department is the epitome of what makes Advanced a manufacturer of choice - we go further to provide customers with exactly what they need. Product List Product Code QZ-2 QZ-4 QZXL-4 QZXL-8 QZXL-12 QZXL-8HS QZXL-12HS QZXL-16 QZXL-24 QZXL-32 Description QuickZone QuickZone - 2 Zone Panel QuickZone - 4 Zone Panel QuickZone XL QuickZone XL - 4 Zone Panel QuickZone XL - 8 Zone Panel QuickZone XL - 12 Zone Panel QuickZone XL - 8 Zone Panel (c/w additional - 2 sounder outputs, 2 switched -ve outputs & 1 aux c/o relay) QuickZone XL - 12 Zone Panel (c/w additional - 2 sounder outputs, 2 switched -ve outputs & 1 aux c/o relay) QuickZone XL - 16 Zone Panel QuickZone XL - 24 Zone Panel QuickZone XL - 32 Zone Panel Product Code QZXL-ZEC Description QuickZone XL Expansion Cards QuickZone XL - 4 Zone expander Card QZXL-HSZEC QuickZone XL - 4 Zone expander Card (c/w additional - 2 sounder outputs, 2 switched -ve outputs & 1 aux c/o relay) QZXL-R12 QuickZone XL Repeater Panel QuickZone XL - Repeater 12 Zone 7

The Standard in Fire Systems UK and EMEAA HQ Moorland Way, Cramlington, Northumberland NE23 1WE UK Tel: +44 (0)1670 707 111 Fax: +44 (0)1670 707 222 Dubai Office Dubai Airport Free Zone, Building W3, Office 211, Dubai UAE Tel: +971 4 299 0908 Fax: +971 4 299 0554 Email: sales@advancedco.com Web: www.advancedco.com SSD1591 [Edition 3]