Introduction to Bulk Solids. The Basics

Similar documents
BHA Powerwave Acoustic Cleaning Systems Powerful cleaning to help increase performance

MICROSENSE FLOW SWITCH

Advanced Level Seminar 2015

Solid biofuel solutions

Model RA Rectangular Aerator

Dust Collectors. Unique Design & Engineering Approaches for Dust Collection and Pneumatic Conveying

ORIGINAL, GENUINE PRODUCTS THAT ARE BUILT TO LAST APPLICATION EXPERTISE YOU CAN RELY ON DEDICATED TO YOUR SUCCESS

SOLIDS FLOW SENSOR SOLIDS FLOW SENSOR: MWS-DP-2

The equipment for storage and transportation of grain

APPLICATION PROFILE EXPLOSIONS IN CEMENT PLANTS EXPLOSIONS IN CEMENT PLANTS CEMENT PLANT EQUIPMENT WITH HIGHEST EXPLOSION POTENTIAL. Form No.

Standard Features. Convey Dry Blend

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

New rotary batch blender cleans up company's testing process

Quality Construction Equipment

Safety Precautions As Related To Operating Slurry Slakers

Once the sensors are mounted and connected to the EGI-RLC-MM, each sensor needs to be adjusted as follows:

ASPHALT PLANT. atlasindustries.in

Laser Level Measurement Products. Introducing the New LLT100

ProcessBarron is a leader in the design, fabrication, installation, maintenance, and repair of air, flue gas and bulk materials handling system

ANNEXURE-A SPECIFICATIONS FOR HOT MIX PLANT

ASPHALT PLANT. MOBILE VARIANTS: MDDM 45 (40-60 tph), MDDM 50 (60-90 tph), MDDM 60 ( tph) atlasindustries.in

Installing Foundation Fieldbus H1 in Hazardous Areas. Presented By: Jim Peterson Sr. Applications Engineer MTL/USA

Industrial Dust Explosions Causes & Case Studies. Presented by Geof Brazier at Expocorma, Concepcion, Chile 10th November 2017

ASPHALT PLANT. atlastechnologiesindia.com. MOBILE VARIANTS: MDM 45 (40-60 tph), MDM 50 (60-90 tph), MDM 60 ( tph)

Low-Cost, Non-Invasive, Microwave-Based Bulk Solids Flow Detector

APTECH DRY AIR STORAGE & CONVEYING SYSTEMS

ASPHALT PLANT. atlastechnologiesindia.com. MOBILE VARIANTS: MDDM 45 (40-60 tph), MDDM 50 (60-90 tph), MDDM 60 ( tph)

BEHN+BATES. Information. Inline Valve Bag Filling Machines

General Design Practices in Reducing Risk in Grain Handling Facilities

ASPHALT PLANT. atlastechnologiesindia.com

Drum Mix facility A schematic diagram of the components in a typical drum mix facility is shown in the figure below.

Microwave Doppler Flow Switch. Installation & Operation Manual

Integrated Solutions for the. Food & Beverage. Industry

The feeder s role The feeder is important to the pneumatic conveying system because it controls the rate of material flow from the feed hopper. When t

Progressive Safety Services LLC 1

Handling Equipment & Dedusting

M-Sens 2 Application overview. FlowJam application overview. Online moisture measurement for solids. For measuring capillary and surface humidity

Concrete Plants ASTEC. Roller Compacted Concrete and Cement Treated Base

Microwave Sensors for Industrial Applications

venting method will work for all pressure conveying systems, analyzing your available equipment, your material s characteristics, and your conveying c

ASPHALT DRUM MIX PLANT - MDM 25 (20-30 TPH) I TECHNICAL SPECIFICATIONS COLD AGGREGATE FEEDER

CHAPTER 3 ASPHALT CONCRETE PLANTS

Document Code: 1 (6) Issuing date: Status:

ASPHALT DRUM MIX PLANT - MDM 25 (20-30 TPH) I TECHNICAL SPECIFICATIONS COLD AGGREGATE FEEDER. Gathering cum slinger conveyor 500 mm x 7.

PRODUCTION OF PARTICULATE MATERIALS

Information on Feeder Systems ProMinent Australia

Lightweight Concrete Mix Profitable Using Heavyweight Batch Mixer

Simply Plug and Convey

Is your process protected?

DM 45 (40-60 TPH) ASPHALT DRUM MIX PLANT - DM 50 (60-90 TPH) I TECHNICAL SPECIFICATIONS DM 60 ( TPH) COLD AGGREGATE FEEDER.

ROTARY DRYER CONSTRUCTION

...just the right thing for everyone - individually adapted

Ronan Model X96S Series Weighing System

Acrison. Model 515 Polyelectrolyte Preparation Module. For Dry and Liquid Polymers. Industrial and municipal chemical feed equipment.

CHP-turbine room. CHP can capture almost EXTRACTED STEAM 20 PSI HIGH-PRESSURE STEAM 1250 PSI HEAT EXCHANGER HOT WATER SUPPLY F

ASPHALT PLANT. AtlasTechnologiesIndia.com

Exploring Vacuum Technology in Pharmaceutical Processing FDA Eases-the-Way for Processors to Automate Processing Lines with Safer, Faster and

Vacuum - The Universal Conveying Force Suction and transportation of powders, liquids and gases

PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY

Fire Protection Guidelines for Handling and Storing PRB Coal

LS 1 Empty Belt Detector RF Admittance PXL1-XX02 PNL1-A. LS 2 Plugged Chute Detector RF Admittance PXL1-XX50 PNL1-A LS 3

Prevention of Fires and Dust Explosions within the Biomass Handling Process. PFI July 20, 2015

Computer Controller. The Bio-Burner has user regulated settings as well as built-in safety features to protect you and your burner.

SEGLER Customers. Made to Measure Solutions. Certified excellent quality. Products and Services. Different types of facilities and customized designs

Ultrasonic Point Level Switches

OPERATION AND MAINTENANCE INSTRUCTIONS MODEL 530 VIBRATORY LOSS-IN-WEIGHT FEEDER

Efficient Vacuum Conveyors Deliver Cost-Effective Solutions Pick-up, conveying and feeding of powders, granules and other bulk materials

ADJUSTMENTS FOR EFFICIENT AND PRECISION SEED CLEANING James Henderson Y

User Detection Sensors

Pneumatic Vacuum Conveying: an Easy Clean, Efficient, and Safe Mode of Transfer for Difficult or Harmful Pharmaceutical Powders

Ex Products Highest level of safety under the most difficult conditions

Boiler Technical Specifications (2013)

Reverse-Air Dust Collectors

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

BULK HANDLING SYSTEMS FOR THE FOOD, CHEMICAL AND PHARMACEUTICAL INDUSTRIES INGREDIENTS ENJOY CEPI

International Process Plants

Ultrasonic Switches. Features & Benefits

Coarse Material Washers & Blade Mill Aggregate Washers FROM

WINDFERN ROAD HOUSTON, TEXAS D-500 Dry Polymer Make Up System

Non-Destructive Dust Removal

industrial electronics electronic level measurement system

Radiation-based measurement Detectors

PRODUCT LINE QUICK REFERENCE. Worldwide Level and Flow Solutions SM

MJC cartridge dust collector

Once the sensors are mounted and connected to the EGI-RLC-MM, each sensor needs to be adjusted as follows:

The element is closed at one end and open at the other, and it s bolted onto the explosion vent opening on the equipment so that its open end overlaps

Level, Flow & Dust Detection Controls

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

C&W specializes in dust control for a variety of sand-related applications.

Pretreatment Applications. John Meunier Products and Solutions WATER TECHNOLOGIES

Matters Needing Attention of Electrical Equipment Installation Engineering in Hazardous Areas. Wang Qiaoli

From simple point level controls to advanced computer-based inventory management

D-1000 Dry Polymer Make Up System WINDFERN ROAD HOUSTON, TEXAS

Revision date Section Change page(s) Description

Instruction Manual April sitrans AS 100

Granulators Reprocessing Plastic Scrap into Valuable Regrind. world of innovation

Tasmanian supplier of high quality instrumentation, control and electrical equipment for all industries. Mining, Food and Beverage, Water and

AQ Translated English of Chinese Standard: AQ WORK SAFETY INDUSTRY STANDARD

Dense phase. Pneumatic conveying. Main advantages. Vacuum conveying - Working principle. Positive and negative conveying pressure.

Ribbon Blenders and other horizontal mixers

Transcription:

Introduction to Bulk Solids The Basics

Glossary of Terms Angle of Repose This is the angle that material will naturally mound up when filling a tank, or down when discharging a tank. Dielectric Constant All materials have a dielectric constant greater than Dry Air (Dk = 1). This term refers to the capacitive properties of a material. Materials such as plastics have a range of 1.2 to 3.0. Oils usually range between 2.0 3.0, while water (moisture) is usually 40 80. 2

Glossary of Terms Hazardous Areas Area of a plant determined to be hazardous typically due to gases, vapors, or dust Explosion-Proof Enclosures Contains an explosion within the enclosure Does not allow a secondary explosion or ignition outside of the enclosure Intrinsic Safety (IS) IS Barriers limit the amount of current to a device, preventing any ignition source The IS Barrier must be located in a safe (General Purpose) area 3

Glossary of Terms Bulk Density Weight of the material per volume such as pounds per cubic foot (lb/cu.ft.) or grams per cubic centimeter (g/cc). Hygroscopic Material will absorb moisture, some examples include starch, flour, fly ash, clays and cement. 4

Glossary of Terms 4-20mA The 4-20 ma current loop is a very robust sensor signaling standard. Current loops are ideal for data transmission because of their inherent insensitivity to electrical noise. 5

Glossary of Terms Guided Wave Radar A low powered, nanosecond-wide pulse is sent along an electrically conductive cable. When the pulse reaches the material a pulse is reflected back and then detected. The pulse is detected as an electrical voltage signal and processed through the electronics. Level distance is proportional to flight time of the pulse. Time Domain Reflectometry (TDR) Is a measurement technique used to determine the characteristics of electrical lines by observing reflected wave forms. Capacitance Is the ability of a body to store an electrical charge. 6

Glossary of Terms - Vessels Silo Type of construction could be welded, bolted, corrugated or spiral wound Welded Silo Bolted Silo Corrugated Silo 7

Glossary of Terms - Vessels Hopper Usually refers to the conical portion of a silo where the diameter decreases in size down to the discharge point. Sometimes refers to vessels which have very little or no straight side wall. 8

Glossary of Terms - Vessels Surge tank or surge hopper Similar to hopper but usually closed top and under pressure. 9

Glossary of Terms Rotary Air Lock (Star Valve or Rotary Valve) Isolates air in pneumatic conveying systems Can be used as a feed device when used with a variable speed motor. 10

Glossary of Terms Slide Gate Valve (Knife Valve) Used to regulate discharge rate from silos or hoppers 11

Glossary of Terms Diverter Valve Used in pneumatic conveying systems to divert material from the discharge of a hopper or silo to the top (fill point) of a hopper or silo. 12

Glossary of Terms Conveyor Types: Screw, Pneumatic, Drag, Belt, and Bucket Elevators Used to move bulk materials. Bulk materials are always filled from the top of a bin, and emptied from the bottom. 13

Glossary of Terms Screw Conveyor 14

Glossary of Terms Pneumatic Conveying System 15

Glossary of Terms Tubular Chain Drag Conveying 16

Glossary of Terms Bucket Elevators 17

Level Measurement Characteristics Liquid Level Measurement Liquids always lay flat in the tank Liquids usually flow in and out of the tank easily Liquids do not aerate, settle, or compact in a tank Liquid seeks it s own level Steam and vapors may be present with liquids Liquids are often under pressure 18

Level Measurement Characteristics Dry Bulk Level Measurement Material rarely lays flat in a silo or tank. Angle of repose varies with different materials Flow of material into and out of the tank must be considered. Level indicating device cannot be located near the fill stream. Mass flow discharge in a tank can destroy a side mounted level indicator. Dry bulk materials can be aerated; can settle and compact over time; bridge; rat hole. In order to solve flow problems, aeration or vibration may be introduced. Dust in a silo is created by filling, discharging or aerating the material in it. Dust can blind ultrasonic or laser measuring devices. It can also coat point level devices, causing false readings. 19

Flow Characteristics Funnel Flow Material flows from the side walls into the middle of the tank when discharging. Material does not move down the side wall of the tank. First material entering bin usually is the last material out Can cause material to remain in tank when tank appears to be empty. 20

Flow Characteristics Mass Flow Material flows down the side wall of the vessel as it discharges. All material in the tank is in motion when any is withdrawn. Angle of repose flattens as material is discharged. First material in, first material out Vibrators, live bottom bins, air slides, or aeration pads are usually used to help create mass flow. 21

Flow Challenges In Silos Rat Hole Material above discharge point empties out of bin, leaving material around the outside walls. Can be several feet in diameter down to a few inches. Problem: If a level instrument is located above the rat hole, the tank may appear empty. If the level instrument is located anywhere on the side wall, the tank will appear to have material at that point. 22

Flow Challenges In Silos Bridging Silo discharge valve is open, but material does not discharge. Can be caused by cohesive material, undersized discharge opening, shallow hopper (cone) section, or inadequate aeration. If a low level switch is located below the bridged material, it will indicate that the silo is empty. 23

Flow Challenges In Silos Problem Combinations Funnel flow can lead to a material bridge or a rat hole. Cohesive materials (materials that stick to themselves) such as Bran, Cement, and Flour are more likely to bridge or rat hole. 24

Level Measurement Challenges In Silos (1) Center Fill / Center Discharge Tank (2) Mount level control 1/6 diameter or 1/3 from side wall. This is the average level point due to angle of repose. (3) In Funnel Flow silos there is no change in level reading until the positive angle of repose of material becomes completely negative 3 1 2 1 25

Applications Questions to Ask Point Level or Continuous Level? Does the customer want a switch (point level) or a continuous measurement (read 0% 100%)? Output Requirement? Related to above Does the customer want a switch or relay output? Does the customer want a local readout, 4/20mA output, digital communication? Area Classification? Will the instrument be in a General Purpose area or a Hazardous area? Intrinsic Safety or Explosion-Proof? 26

More Applications Questions Temperature? Most integral level switches can be applied in materials up to 200 F (93 C). Above this temperature, electronics housings must be separated from the heat source What are the maximum, minimum, and normal temperatures the level instrument will be exposed to? Many dry bulk materials are hot.. Vibration? Materials that do not flow well usually require some assistance. Vibrators or Live Bin Bottoms are used to assist material discharge. Does the tank have a live bin bottom, or is there a vibrator on the tank? Where is it in relation to the level sensor? 27

More Applications Questions What is the material? What is the material s bulk density? What is the material s moisture content? What is the range of material size? Does the material coat the side walls? Is the material a food or drug? 28