YMA Air Handling Units

Similar documents
YMA Custom Air Handling Units

Centeral Station Air Handling Unit

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

EHH SERIES DRAW THROUGH FAN COILS CFM

Double Skin Casing Air Handling Units

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Modular Air Handling Unit

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

MODULAR AIR HANDLING UNIT. Models: FAC / FMC / FBC

AQX Air handling units. Air flow 1, ,000 m 3 /h (350-44,400 l/s)

AIR HANDLING UNITS MANDÍK

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Double Skin Air Handling Units

Easdale International INFINITY

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

39G Air Handling Unit

AHU N Range AQX. AQX Air handling units. Air flow 1, ,000 m3/h (350-44,400 l/s)

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

1.1 This section applies to air handling units for HVAC Systems.

CLIMACIAT. air HanDLIng UnIT: CLIMaCIaT. Air handling unit

Air Handling Units. Real HVACR people who understand your needs.

VRV+AHU System DAIKIN NEW STANDARD SERIES UNIT MODEL AHUR-CA/SA

GUIDE SPECIFICATIONS FOR AIR HANDLING UNITS VENTILATION UNITS & HEAT RECOVERY UNITS

SECTION AIR HANDLING UNIT

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

TYPICAL CPA SPECIFICATIONS

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

Double Skin Air Handling Units

Cert. n Air Conditioning Vulcan Pro Air Handling Units

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

SECTION AIR HANDLING UNITS WITH COILS. 1. Central Station Air Handling Units. 1. Section Basic Mechanical Requirements.

Product catalogue Air handling units. Easy and flexible solutions for any ventilation requirements

The ultimate in air handling units: directly and indirectly fired

AIR HANDLING UNITS. Revision AG 16-07

TEXTILE AIR ENGINEERING EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY

VERSO Air Handling Units

york airside products Creating higher comfort and flexibility

39FD, FX. Air Handling Units. 280 l/s to l/s 39FD, FX

Advance Release September 2009

Modular Supply Make-Up Air Unit

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

Panther Fan Coil Unit

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

The ultimate in air handling units: directly and indirectly fired

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Indoor Air Quality. For assured. Double Skin Air Handling Units

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

Customer id 2452 Project 1152 Unit 189 ACON From Inspection Side. Unit name AHU-22 R.05 Supply air EU m³/sec Exhaust air

ENGINEERING & SERVICE

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

When it comes to comfort cooling or air conditioning, Johnson Controls meets all your product needs.

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

AIR HANDLER SPECIFICATION

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

39HQM Central Station Air Handling Units AiroVison Guide Specifications

VERSO Air Handling Units

Series 2 FS 100 HM Q S AH D on innovative. a full green. meeting. line features. Page No Introduction a high unit is. Air Handling Units

Enjoy the Delighting Comfort Brought by High Air Quality

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

VTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories...

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

The ultimate in air handling units: directly and indirectly fired

Efficient energy recovery in AHU. DOHA, Qatar Timo Schreck Enventus AB, Sweden

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

DVU-HP. Integrated Reversible Heat Pump System

Pharmaceutical Facility Design

Energy. The Energy ducted units have been designed. Heat Recovery Unit

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

COOLING and DE-HUMIDIFICATION WITHOUT USING REFRIGERANTS

SeasonMaker ThinLine Fan-coil Units

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

13 HYGENIC AIR HANDLING UNITS

THE ULTIMATE ROOFTOP SOLUTION

Submittal Data Performance Data Electrical Data

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

CONTACT US. For more information,

DIVISION 15 MECHANICAL

Heat pump and energy recovery systems

Submittal Summary Page

air systems Large Rooftop DIC-BIH-DIG 360 to 480 G

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

ALL PRODUCTS BROCHURE

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

FCC Fan-Coil Units High-Performance, Vertical

Transcription:

YMA Air Handling Units

Certifications Page 2

Page 3 YMA Modular Air Handling Units Air Volume Range 0.25 m 3 /s to 26 m 3 /s The YMA family of air handling units has air volumes ranging from 0.25 m 3 /s to 26 m 3 /s and total static pressures as high as 1600 Pascal. Custom designed units with larger capacities up to 50 m 3 /s are also available. All units are designed using NEXUS 1V.601.3014. All units are constructed from extruded aluminium profiles and have flush fitting panels and doors to provide aesthetically pleasing lines. All panels are completely removable. The thermally insulated rigid enclosure is fully sealed and has a high acoustic performance. Accurate computer selection ensures cost effective matching of all components to satisfy the specified conditions. YMA Air Handling Units can be manufactured in varied configurations, with a wide selection of components, to meet customer requirements. They may include combinations of any of the following: Single or double decked units. Indoor or outdoor applications. Outdoor units are available with a flat or sloping roof, louvres, rainhoods, birdscreens and special finishes. Site assembled units. Where space constraints restrict the size of a single item modules can easily be aligned and locked together by gaskets and stainless steel bolts inserted into factory predrilled assembly holes. Air mixing boxes. Various filter options. Cooling and heating coils. Cell deck Humidifiers. Heat recovery systems. Various fan types and drives. Sound attenuation. Miscellaneous components.

Page 4 The Frame The low weight corrosion resistant aluminium alloy twin box section profile is designed to provide strength and stability. Gaskets, between panels and profile, ensure airtight sealing. A thermal bridge free profile can be provided. Unit sections are mounted on a 4mm thick extruded aluminium base frame. Panels Standard 30mm or 60mm double skinned galvanised panels comprising 0.6mm internal and external skins and 40kg/m3 density pressure injected polymerised polyurethane foam insulation. Optional panels can be manufactured from pre-plastic coated steel, or Perluman. Panels are fixed to frame with galvanised screws. Access Panels are fully removable. Access doors are equipped with half turn nylon handles and cam locks. Hinges are fibreglass reinforced plastic with stainless steel pivots. Optional double glazed viewing portholes can be supplied. Standard Construction Dampers Extruded aluminium dampers are the opposed blade type. Flanged frame is provided for ductwork connection. A gasket is installed to minimise air leakage. Spindles are manufactured from aluminium or nylon and have nylon bushes. Control links are aluminium. Cold Bridge Free Construction

Page 5 Web Address: http://www.eurovent-certification.com Programme Air Handling Units Participant AL SALEM - YORK MANUFACTURING CO.LTD. Brand YORK Air Handling Units AHU 04.01.048 Range: YMA Construction Sizes Model Height Width Designation mm mm YMA-XXXX/YYYY WITH: XXXX=HEIGHT AND YYYY=WIDTH from 450 to 4050mm in step of 40mm from 500 to 7000mm in step of 50mm Performance characteristics YMA Catalogue Selection Software : NEXUS-1 v.601.3014 Performance characteristics (air flow, available pressure, power input, cooling and heating capacity, sound power, heat recover y system) as given in the above selection software are certified. Mechanical characteristics Class Casing designation Characteristics MB30 POLYYURETHANE MB60 POLYYURETHANE MB60 POLYYURETHANEtb MB60 ROCKWOOL MB60 ROCKWOOLtb Casing strength 2 2A 2A 2A 2 Casing air leakage under -400 Pa B B B B B Casing air leakage under +700 Pa B B B B B Filter bypass leakage F8 F8 F8 F8 F8 Thermal transmittance T3 T2 T2 T2 T2 Thermal bridging factor TB4 TB4 TB3 TB4 TB2 Acoustical Insulation Insertion Loss Casing Designation Frequency (Hz) 125 250 500 00 00 4000 8000 MB30 POLYYURETHANE 13 13 15 14 16 31 37 MB60 POLYYURETHANE 12 13 14 15 26 33 36 MB60 POLYYURETHANEtb 11 14 14 15 27 33 37 MB60 ROCKWOOL 13 26 34 32 30 36 37 MB60 ROCKWOOLtb 13 25 33 31 30 36 31

PSYCHROMETRIC CHART 0 mt ABOVE SEA LEVEL Barometric pressure 1.325 kpa 0 0 30 5 40 50 60 15 70 - -5 0 5 15 25 30 35 40 45 50 Dry bulb temperature C 80 90 25 0 30 29 28 27 26 25 24 23 22 21 19 18 17 16 15 14 13 12 11 9 8 7 6 5 4 3 2 1 PSYCHROMETRIC CHART 0 mt ABOVE SEA LEVEL Barometric pressure 1.325 kpa 0 0 30 5 40 50 60 15 70 - -5 0 5 15 25 30 35 40 45 50 Dry bulb temperature C 80 PSYCHROMETRIC CHART 0 mt ABOVE SEA LEVEL Barometric pressure 1.325 kpa 0 0 30 90 5 25 40 50 0 60 30 15 70 - -5 0 5 15 25 30 35 40 45 50 Drybulb temperature C 80 90 25 0 30 29 28 27 26 25 24 23 22 21 19 18 17 16 15 14 13 12 11 9 8 7 6 5 4 3 2 1 29 28 27 26 25 24 23 22 21 19 18 17 16 15 14 13 12 11 9 8 7 6 5 4 3 2 1 Page 6 DATA SHEET 06/07/06 /09/06 P 1 / 4 581500 Nexus-1 ver.113.03 0 Model YMA - 08H-10W Project Al Salem York Jeddah Ref. Flow AHU-1-0- 0.80 m3/s 01 FA DAMPER 700 x 990 mm 03 G3+F8 04 ADH 0 R - 1269 RPM - 0.75 kw 1525x027-G-05C-C-0-S-035-W-H-R-C-S-07-C-M-1.25-05 17 RDH 225 R - 3774 RPM - 1. kw 23 FA DAMPER 700 x 550 mm 24 G3 850 600 7 137 463 302 55 HEAT RECOVERY W HEEL Model W0800/0/025/AL DATA SHEET 06/07/06 /09/06 P 3 / 4 581500 Nexus-1 ver.113.03 0 Project Model Al Salem York Jeddah YMA - 08H-10W Ref. Flow AHU-1-0- 0.80 m3/s Qty Enthalpy rotor Variable speed 1 NO NO 8 x 10 005 004 242.5 024 023 700 8 SUMMER Fresh Air WINTER Fresh Air 16 55 011 55 6 m3/s kw Eff.% Inlet Outlet C % C % Pa m3/s kw Eff.% Inlet Outlet C % C % Pa 8 x 10 55 700 0 001 003 718 132 850 450 015 014 500 333 254 1313 1900 415.9 017 018 270 334 8 0 1 1 0.8 4.1 59.5 32.0 50.0 27.8 63.5 95 Exhaust Inlet Outlet m3/s kw Eff.% Pa C % C % 0.8 4.1 59.5 25.0 50.0 29.2 39.1 92 0.8 14.5 58.6-5.0 80.0 9.6 26.8 77 Exhaust Inlet Outlet m3/s kw Eff.% Pa C % C % 0.8 14.5 58.6.0 45.0 5.4 0.0 87 30 10 371 006 008 237.0 302 275 550 Enthalpy kj/kg Saturation temperature C Humidity ratio g/kg Enthalpy kj/kg Saturation temperature C Humidity ratio g/kg 007 427 009 275 0 025 ACCESS DOOR 55 0 1 2 Dimensions 15 x 340 mm Handles 10 990 55 171 383 685 244 019 0 416.0 021 022 334 383 0 1 3 ACCESS DOOR Dimensions 700 x 2 mm Handles 002 012 013 016 DRAIN PAN Panels PANELS / FRAME Thickness 60 mm Break out Airborne sound power (db) A 125 Hz 250 Hz 500 Hz 1 KHz 2 KHz 4 KHz 8 KHz 0 1 4 Material C304-12 Drain size 48.00 mm Insulation External sheet Internal sheet ALUMINIUM FRAME FEET polyurethane 40 kg/m3 Preplasticized steel sheet C3-06 0.6 mm - IVORY 3 MN Preplasticized steel sheet C3-06 0.6 mm - IVORY 3 MN PR55TT CBZN{ H = 0 mm } 60.5 70 59 59 54 41 43 41 Mechanical characteristics (EN1886) Casing strength Casing air leakage Thermal transmitt. Thermal bridging T2 TB3 Al Salem York Manufacturing Co. Ltd. is participating in the Eurovent Certification Programme for Air Handling Units. The range YMA is certified under the number 04-01-048 and presented in the Directory of Certified Air Handling Units 0 1 5 A S Y M C O IL Flow Qty Model Air dens. 0.80 m3/s 1 CA-006--21.25x027-G-05C-C-0-S-035-W-H-R-C-S-07-C-M-1.25-05.00-A-H-L-99-S-S [ 0 mt ] 73.13 dm3 0.00 m2 1.225 kg/m3 Air side DB WB UR Tootal load Sensible load Air vel. Pressure Drop In 32.00 C 25.00 C 57.06 % 1x32.6 kw 1x16.1 kw 2.16 m/s 131 Pa Out 15.40 C 15.00 C 95.97 % WATER temp. Water flow Water P.D. Water vel. Connection size Enthalpy kj/kg Saturation temperature C Humidity ratio g/kg In Out 7.00 C 1 x 32 1 x 1.60 l/s 28 kpa 1. m/s 12.00 C 1 x 32 NC Fins material Tubes material Headers Frame Flange Counterflange 7 AL-HERESITE CU Copper Galvanized Steel MPT NO ACCESS DOOR List price Total weigth 734 kg 0 1 6 Dimensions 700 x 500 mm Handles + Hinges Sample Printout Sample Printout Sample Printout

Page 7 Filters Filter sections are designed for easy withdrawal of the following filter types: Prefilters Synthetic or glass-fibre media panel filters, class EU2 to EU4 (EU3 supplied as standard) arranged in galvanised steel frames or sliding rails. Main Filters Synthetic or glass-fibre media bag filters, class EU5 to EU8 (EU6 supplied as standard) arranged in galvanised steel frames with gaskets to avoid air bypass. Final Filters High efficiency compact cell filters, class EU to EU12 (HEPA 95 to 99.99% Nacl), fixed with brackets, nuts and bolts or clamps to a heavy galvanised steel gasketted structure. Condensate pans are a dry pan design, manufactured from a choice of aluminium or stainless steel to ensure complete condensate removal. The drain pan is double skin insulated PPTM droplet eliminators are fitted after cooling coils when the air velocity exceeds 2.5m/s or high latent load on request. Coil options are: Medium/high pressure steam coils. Copper fins. Electro-tinned copper fins. Epoxy coated fins. Direct expansion coils. All steel coils. Stainless steel drain pans. Aluminium droplet eliminators. Electric Heating Coils Manufactured from low temperature screened stainless steel tube and spiral fin heating elements secured to a heavy gauge steel frame. A automatic reset safety thermostat. Optional High temperature cutout Airflow switch are fitted Step or modulating control Cooling and Heating Coils Cooling and heating coils are computer selected to achieve the optimum psychrometric efficiency with low air and water pressure drops. Coils Standard coils are constructed from copper tubes mechanically bonded to aluminium fins, with threaded copper headers, all contained in a galvanised steel frame. Air vents and drain connections are provided. Coils are leak tested at 30 bar with a maximum design pressure of 16 bar. The cooling coil assembly is located in a drain pan. The coil section can be removed easily from either side.

Page 8 Humidifiers Generated Steam Humidifier (Special Option) Consists of immersed electrodes, steam cylinder, stainless steel distribution pipe and electronic controls for water regulation and automatic flushing. Cell Deck Humidifier A viscose-coated evaporating pack is moistened with water, circulated by an internally mounted pump with removable strainer, from a header tank. The base tank includes a ball valve, overflow and drain. The assembly is constructed from aluminium alloy sheets. Options Galvanised and painted internal parts. Stainless steel structure, tank and eliminators. fans. Fan inlets are aerodynamically designed and wheels statically and dynamically balanced according to airflow and speed. Smaller fans have sealed for life bearings and larger versions have pillow block type self aligning ball journals with grease points. Vee belt fan drives have removable fan guards. (Option) Motors are totally enclosed fan cooled type class F insulation to IP55 protection. Fans YMA units are supplied with one or two double inlet, double width forward or backward curved centrifugal

Page 9 The total fan assembly is installed on a separate frame isolated from the unit structure by spring anti-vibration mounts. Where plant space is at a premium plenum type fans may be used. The plenum fan pressurises an acoustically lined fan chamber and circular or rectangular discharge duct connections can be located on the external faces of the chamber. This reduces the length of the air handling plant by eliminating the need for external attenuators or complicated duct transformation pieces. Please contact local sales office for fan application details. Sound Attenuation Fan Controls Double speed fan motors. Direct drive fans. Fan speed frequency inverters. Standard attenuation sections, having baffles of galvanised steel and hygroscopic material, are available in six lengths from 600mm to 1800mm. Perforated plate liners are optional. Heat Recovery The following forms of heat recovery equipment can be supplied: Plate Heat Exchanger Manufactured from aluminium (optional stainless steel or polycarbonate) and turbulation channels to permit heat transfer from warm to colder air systems without mixing the two air streams. Drain trays are provided for condensate collection. Horse Shoe Heat Pipe By circuiting heat pipes in sections before and after the cooling coil heat is removed from the air stream before it encounters the cooling coil. The passively pre-cooled air means less sensible cooling is required by the coil, providing more latent capacity, and superior dehumidification ability. The now Over-cooled air passes across the re-heat section of the heat pipe, bringing the air temperature to a comfortable supply condition. Thermal Wheel Available with a hygroscopic or non-hygroscopic rotor for recovering and transferring heat energy from the exhaust to the supply air streams. Lighting Optional water resistant bulkhead lights and switches can be supplied. Computer Selection Programme The flexible computerised programme provides the optimum equipment selection, to satisfy the specified conditions, and provides full technical information and certified drawings. NEXUS - 1 V.601.3014 Heat Pipe Vertically mounted tubes, charged with refrigerant, exchange heat by the evaporation of warm air stream in the lower section and re-condensation in the cold air stream in the upper section.

Page Notes

Johnson Controls provides comfortable environments wherever you Live, Work or Travel Whether you re at home, in a car, or in an office or workplace, chances are there s a Johnson Controls product or service nearby, helping to make your environment more comfortable, safe and sustainable. Johnson Controls creates smart environments that improve the places where people spend most of their time their homes, workplaces and vehicles. We anticipate consumer needs, and then integrate technologies, products and services to make life better and easier. For Johnson Controls, sustainability matters at every level and through our products, service operations and community involvement, we promote the efficient use of resources to benefit all people and the world. Our triple bottom line of sustainability that is, economic prosperity, environmental stewardship and social responsibility impacts each and every aspect of our business. York products are now a premier brand manufactured by Johnson Controls. The acquisition of York, gives us a unique insight into designing HVAC products that match your exact requirements. We provide solutions for today's most critical concerns - energy efficiency, refrigerant alternatives and indoor air quality. Johnson Controls has a wide range of York products for residential, light commerial and commercial applications. Our offering includes package & split air conditioners and heat pumps. In addition, Johnson Controls offers chillers, air handling units, ventilation equipment and controls for larger projects. Our advanced technology is leading the way in developing efficient and environment friendly solutions for your homes, offices and places of leisure. Let us create the ideal environment for you. YMA/EUV/03-08 Supersedes YMA/EUV/09-06 We reserve the right to change in part or in whole the specifications without prior notice. Johnson Controls Middle East Head Office P.O. Box 365, API World Tower, Sheikh Zayed Road Dubai, United Arab Emirates. Tel +9714 3326050 Fax +9714 3326074