METOS Compact SMS. The smooth change of a product. Gottfried Pessl

Similar documents
Monitoring Solutions

SMS GSM Alarm Messenger

SC-F3G User Manual 1.0

with internal sensor (channel 1) with an external sensor (channel 2) A-Editor software, Professional AK20 version (not for version AK4)

HRX Technical Manual. Version 1.2

GLOBAL. InstallatIon & operation manual

BSC-50 ADU-500. Autonomous RTUs

Complete packages with Software and Controller

HRX3000. Technical Manual

Inner Range FE3000S. Serial GSM Modem. P/No: INSTALLATION MANUAL

SolarSET GSM SolarSET GSM with a Beacon

Upgrade of PSTN network Alarm System

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

PERMACONN PM1030 Includes DI300. Installation Manual

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Specification for On-Line UPS Battery Monitoring and Data Management System

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

HOBO U30 Remote Monitoring Systems

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

FIRElux Emergency Lighting

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Intelligent monitoring system for automobiles

Chromatographic Air circulated Refrigerator, two-door TC 603

GSM 3G AUTO DIALLER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard.

Cold chain monitoring technologies. Facility monitoring

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

Sentient. Downloader Manual D4854

GSM PROTECT ANTI-THEFT ALARM WITH GPS TRACKING & MOBILE PHONE ALERTS

Products compliant with the following standards and regulations: EN81/70, EN 81/28 and EN 81/72. Lead-free manufacturing. Reduced energy consumption

Chromatographic Air circulated Refrigerator, two-door TC 603

Сontrol panel Contact GSM-9N

T4000 Security Communicator

MONITORING. Software. M2M Transfer. Data Input. Processing. Reports Graphs, Excel Alarms. Logging Analysis, Alarms Various products

Internet enabled RTU/Data loggers. ilog-gsm/edm: Tutorial Vers /2.0 August 2006

InvisiFence User Manual

Measuring Recording Online Monitoring Regulation Alarming

Air Resource Specialists, Inc.

EasyLog Data Logger Series

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Remote monitoring for technical condition of buildings and constructions

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

your silent and loyal servant

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

idware Idware Remote Site Monitoring Solution

600 Range Dialer Installation Manual. Version 1.0

2G & 3G GSM Door Contact Alarm


Security designed for your lifestyle

YachtSafe GPS Alarm Manual

Intelligent Fire Detection and Visual Guided Evacuation System Using Arduino and GSM

IC60 Sintony 60 Intrusion Control Panel

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

IP & SMS Alarm Communicator

Kwêbeam GSM/Interface/Repeater Module

ALARM OUTPUT MODULE. Product #7736

WeatherLink for Alarm Output Addendum

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

M3092 Programmer. User s Manual. M3096B-33 E Copyright 2017 SELCO

System solutions for every lift. Everywhere. Lift emergency EasyGate PRO and Lift1

Octalarm-T: the latest in future-proof industrial alarm diallers

SI120 Guarto Easy I. Alarm system. Fire & Security Products

PROTECTION CABINETS SUPERVISION CABINETS FOR AUTOMATIC EXTERNAL DEFIBRILLATORS (AEDs)

Dry Contact Probe DCP (#30008)

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Access Control (card access)

VEHICLE SAFETY WITH DIALLING SYSTEM AND AUTOMATED LOCATION TRACKER

CRIOTEL. The complete solution for local and remote monitoring of cryogenic tanks under pressure

Exercise 8. Controlling a Batch Mixing Process EXERCISE OBJECTIVE

Elderly Care Alarm System

Common Questions & Answers

PROFESSIONAL GSM/GPRS WEATHER STATION. Operation Manual - 1 -

RS485 MODBUS Module 8AI

Microcontroller based design for Tele-sensing and extinguishing fire

Specialists in communications for the elevator industry

COMMUNICATOR ET08 / ET081

EL-USB-1-LCD Temperature Data Logger with LCD

Design of Intelligent Alarm System Based on GSM Network Shun Qing XU

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

MO n : 12JMC rév A

Snitcher. Installation Instructions

USER S MANUAL HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY

MiNi Server environment MoNitoriNg SySteM

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

Addressable and Conventional Fire Protection

Mercury Vapor Monitor VM-3000

Batt-Safe Battery String Monitoring System

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

Laboratory Refrigerator/Deep Freezer TC 802

SEE DISCLAIMER ON REVERSE

Solution F2. Fire Alarm Control Panels one step ahead.

System Manual W A R N I N G. PC6O1O Software Version 2.1

ELECTRICAL COMPONENTS REMOTE LIFT ALARM

CE818. User Manual. Made in Italy M1.5.1-H2.0-F1.41-S1.41-ENG

Transcription:

METOS Compact SMS The smooth change of a product Gottfried Pessl

METOS Compact the Technical Specifications Single Board Climate Station 512 kb Flash Memory 8 bit Siemens µprocessor 12 Minute Measurement Interval 12 Minute Logging Interval 13 Specified Sensor Inputs 1 unspecified Analogous input RS232 Serial Interface with 19200 Baud 7 bit Programmable Alarm Output Operating Temperature -20 C to 60 C Two 6 Volt 4 Ah Lead Acid Batteries Solar Power Supply Less than 450 µa Average Power Consume without Communication Less than 3 ma Average Power consume with daily data download The actual METOS Compact is representing more than 14 years of experience in producing electronic climate stations by Pessl Instruments.

METOS Compact More than two years ago the former barometric pressure input has been changed to an open unspecified input place. This gives bigger opportunities to adapt the system on specific needs.the extended use of one unspecific analogous input place: Barometric pressure Second Watermark sensor tensiometer conductivity... Power Switch and Fuses Plugs for: Barometric Pressure place METOS 2 Leaf wetness sensors 3 Temperature sensors eprom RAMemory CompactFlash Memory 2 Relative Humidity sensors Solar Panel and Battery Plugs for: 1 Analog Input 1 Watermark sensor 1 Global Radiation sensor 1 Wind Direction sensor 1 Wind Speed sensor 1 Rain Gauge 1 Day Length sensor µprocessor Alarm Output RS232 Interface

METOS Compact More than two years ago the standard speed and the behaviour of the serial interface has been changed to 19200 and the support of hardware handshake. This change was made to support the use of GSM modems. It is still possible to change the speed to lower Baud rates by the use of a specific command: This change of Baud rate will be part of the upcoming software version. GSM GSM modems are working with 9600 upt to 14400 Baud in air. This is only possible if the speed on the serial line is equal or higher then 9600 Baud.

METOS Compact GSM Solutions Since more than six years we are delivering GSM solution. This solutions have changed quite a bit during the years. At this time we are supporting 2 solutions for different applications. 12V Package: Big Solar Panel and car battery with Siemens TC35 6 V Package: METOS Compact Battery with METOS Compact solar panel and Wavecom modem GSM

12V Package: Big Solar Panel and car battery with Siemens TC35 Galvanised Steel box IP 65 Plastic housing for electronic sturdy simple 12V 10W solar panel powerful GSM 12 V > 36 Ah 12V 6 A solar charging controller TC35 modem and antenna with cable and holder SIM card and battery is purchased locally winter hard big expensive

6 V Package: METOS Compact Battery with METOS Compact solar panel and Wavecom modem 5/4 wave length METOS sturdy simple Solar panel 6V 1.6W Lead Acid Battery 6V 4Ah Metos Solar charging controller Wavecom modem antenna and cable SIM card has to be purchased locally GSM power efficient winter adaptable small cost effective

The new METOS Solar charging controller gives the opportunity to use a small solar package nearly everywhere Features support of 2 solar panels support of all day consumer support of only day consumer panel1 panel2 battery Day & night Day times Easy adaptable to the local sun shine situation. Mediterranean climate will not need more than one solar panel for all year 24 hour use. In winter fog areas it will help to switch off the consumer if the solar panel has no power. This means all day use most the time of the year and day time use only from late fall to spring. In northern European areas where sun shine hours are limited it can be beneficial to connect a second solar panel.

METOS GSM Box What makes a METOS Compact SMS? METOS Compact eprom supporting SMS alarm Temperature sensor used for frost alarm The SMS alarm like it is at this stage is designed for frost warnings e.g. for apple growers. It could be expanded to other sensors if there is evidence to do it. It is designed to be used with GSM networks because of their standardisation

SMS Alarm Features Common Features Overall availability of GSM signal mobile phones are part of common live good delivery service inside GSM networks is guaranteed in most European countries no extra receiver for the alarm is needed METOS specific features 3 receivers possible selectable sensor selectable threshold multiple settings possible easy set-up by MetWin or in future via cell phone telephone will ring after receiving SMS

How to set up an SMS alarm from PC Use MetWin2 or MetLink to set up the SMS alarm. If your climate station supports this feature the SMS button is visible. Before using the SMS button make sure that all the sensors on the METOS are working. This is easiest to take a data download and to check the value. 1 st Select the temperature sensor 2 nd select the threshold in the alarm when smaller or alarm when higher window 3 rd input the three telephone numbers 4th send the settings to the METOS

How does the SMS Alarm work An alarm is send when the situation is reached. If the situation is left and reached again another alarm goes out. If the situation stays for less than 5 hours no other alarm is made if it is longer than 5 hours a second alarm will occur.