Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Similar documents
Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

- Pamphlet A2404 TLV. ertrap a ic I Pump & Pump/Trap. GP Series GT Series

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

TL\l DRAIN TRAP. , s. JA JAHR Series I GS. TATSU2 SS1VA/JAHRASeries. Pamphlet A

Pump & Trap Combinations

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

Pure Performance For Steam Mains and Tracers

What is a Secondary Pressure Drainer?

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

THERMOSTATIC STEAM TRAPS

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

LIQUIDATOR UMT-TD Series Thermodynamic

Silhouette. Feedwater Heater. Boiler Feedwater

THERMODYNAMIC STEAM TRAPS

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

STEAM TRAPS

System Solutions. Efficient energy use, effective flash steam utilisation, and tailor-made customer solutions CHEMICAL THE STEAM SPECIALIST.

Pamphlet M JA3D / JA Series / G8 AIR & DRAIN TRAPS. TATSU2 SS1VG / JAHSeries

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

PRESSURE MOTIVE PUMP (PMP) APPLICATIONS

Pamphlet A2000. TL\l. Free Float Steam Trap Series

THERMODYNAMIC STEAM TRAPS

Documento Descargado desde:

MFP14 Automatic pumps for condensate and other industrial fluids

THE THERMOSTATIC STEAM TRAP

Liquid Drainers LIQUID DRAINERS

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

MFP14 Automatic pumps. for condensate and other industrial fluids

Steam Condensing Heat Exchanger SR-3 / SR-8

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

/ / Take the technological step into MODERN Condensate Handling Equipment for steam systems MANUFACTURED IN AMERICA with craftsmanship and quality.

HEAT EXCHANGER FORMULAS & EXAMPLE

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

STAINLESS STEEL PRODUCT GUIDE. Pamphlet M8012

Pumps. Pressured-powered pump catalog. The more reliable and efficient way to pump condensate and other liquids.

Pamphlet M AIR & DRAIN TRAPS. JA JAHR Series / G8 TATSU2 SS1VG / JAHRG Series

Hoffman Specialty General Catalog

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

LIQUIDATOR 450 SERIES

FT14 Ball Float Steam Trap (Screwed)

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

IN THE PULP AND PAPER INDUSTRY

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

Domestic Pump Condensate Transfer Equipment

FT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES. Manufacturer

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

High Capacity Instantaneous Steam Fired Water Heater

Pure Performance For Steam Mains and Tracers

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

A complete, compact steam heat exchange solution for process and domestic water heating requirements.

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

GIRTON CABINET WASHER MODEL 794A

SALES TRAINING HEAT RECOVERY SYSTEMS BLOWDOWN SEPARATORS & TANKS LIQUID SAMPLE COOLERS ORIFICE METERS

SECTION STEAM CONDENSATE PUMPS

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

Steam Systems 101. Understanding Your Energy Systems Better. May 5, 2016

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

Noiseless Heater Vacuum Relief Valve

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Economical and simplified solutions that offer quality and optimum steam trap service.

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Series 1140 and 1141 Temperature Regulators

Automatic Temperature Controller (ATC)

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

A. This Section includes the following domestic water piping specialties:

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

Industrial Processing Solutions

Standard Features. Performance/Capacities

Blowdown Separator & Aftercoolers

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

13-1. Temperature Regulator

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

TECHNICAL. Series 18. Pump Packages

STEAM AND TRAP FUNDAMENTALS

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Our Know-How. Your Peace of Mind. Steam Solutions

Strategies in Optimizing Condensate Return

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

STEAM VALVE SUPPLY & SYSTEM DESIGN

Custom Design TYPE CS

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

Transcription:

Pamphlet A2404 Mechanical Pump & Pump/ Trap GP Series GT Series

Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment are some of the many benefits of condensate drainage and recovery. The GP/GT series provides the perfect solution for optimizing condensate processing in many applications. Handling Heat Exchanger Stall Stabilized temperature control improves product quality Elimination of water hammer prevents equipment damage and improves safety Prevention of corrosion caused by condensate accumulation Effective Recovery Energy recovered from condensate reduces boiler fuel costs Reusing water reduces water treatment costs Reduces effluent treatment and disposal costs No Cavitation Recovery of hot condensate up to 428 F possible without cavitation Low filling head capability permits drainage from near-grade equipment outlets. Eliminates the seal, bearing and impeller damage that can occur in standard centrifugal pumps No Electricity Required Ideal for use in areas requiring explosion-proof equipment, and areas with no electrical supply Reliable mechanical operation eliminates the need for complex level controls Quick and easy to install and maintain

s Series The Total Solution to Heat Exchanger Stall Stall prevents condensate from being discharged from heating equipment. It results in: Equip. press. "Stall" occurs and condensate backs up Process Temperature Swings Press. As the stall cycle repeats, the steam pressure in the equipment varies above and below the back pressure, causing product temperature and quality fluctuations. Temp. Set temp. Back press. Product temp. Time Water Hammer Damage Water hammer can occur when backed-up condensate re-evaporates, or as incoming hot steam hits cooler backed-up condensate and instantly condenses. Water hammer damage to tubes and stays Tube Corrosion and Damage Backed-up condensate in the equipment can form carbonic acid, which results in tube corrosion. Equipment temperature fluctuations can cause thermal shock and fatigue damage to tubes. Tube corrosion s series provides complete condensate drainage, the key to eliminating stall and its related problems. Optimum performance can now be yours with the. Controller When the demand for heating energy is high, the control valve is wide open, P1 is greater than P2 and condensate is discharged from the trap. Steam Control valve P1: Equipment pressure Product outlet temp. When the demand decreases, the control valve throttles in order to reduce the heating energy, and P1 drops. Backed-up condensate Steam space If P1 drops to P2 or below, the trap can no longer discharge condensate against the back pressure. then backs up in the heat exchanger, and the equipment becomes condensate logged. This condition is known as stall. recovery line P2: Back pressure Check valve Product inlet temp. When condensate is backed-up inside the equipment, the product temperature falls. The system compensates by opening the control valve again. P1 increases and, when it becomes greater than P2, condensate is forced out through the trap, and the cycle begins again.

Built-in Steam Trap Improves Performance (GT Series) Snap-action Mechanism Maximizes Life Instantaneous Switching Automatically switches between pump and trap operation, in response to process conditions Internal trap mechanism always matches pump output, with no damage to trap, and eliminates need for sizing No need for external steam trap means simplified compact design and lowered installation costs Trap valve and valve seat are both stainless steel for minimum leakage and maximum life Heat-treat hardened stainless internals Lifetime warranty* nickel-based alloy compression coil spring The 2-year warranty** snap-action mechanism simultaneously opens or closes motive medium inlet and exhaust valves, preventing erosion and resultant leakage * GP/GT14M, GP/GT14L, GP/GT10L, GP/GT5C: 1-year warranty ** GP/GT5C: 1-year warranty Contact TLV for full warranty details Low-maintenance Design Reduces Labor Easy inline maintenance, without removal of piping* Fast and easy cleaning of intake valve by simply opening a plug to remove (GP/GT14, GP/GT10, GP10F, GP/GT5C) Non-cavitating design eliminates the seal, bearing and impeller damage that can occur in standard centrifugal pumps * GP10F, GP/GT5C-motive medium piping must be removed Check Valves * for Durability Center guided check valves CK3MG and CKF3MG are used for maximum reliability even with dirty condensate (GP/GT14, GP/GT10, GP10F, GP/GT10L) Newly developed swing type check valve CKF5M enables use with a filling head as low as 12 (GP/GT14L, GP/GT10L), 14 (GP/GT14M) Last longer than bronze check valves Quiet operation * GP/GT5C are equipped with internal stainless steel check valves Economical Unit with Retrofitable Mechanism One-piece pump assembly for easy installation, maintenance and retrofit to pump bodies of certain other manufacturers Lighter-weight model, with ASME certified fabricated steel body for increased cost effectiveness

Construction GT14/GT14M/GT14L GT10/GT10L Mechanical pump with built-in trap GP14/GP14M/GP14L GP10/GP10L Mechanical pump GP10F Mechanical pump with retrofitable mechanism GT5C Compact mechanical pump with built-in trap GP5C Compact mechanical pump Materials Body (except GP10F, GP/GT5C) 1 2 3 Body (GP10F) Body (GP/GT5C) Cover (except GP10F, GP/GT5C) Cover (GP10F) Cover (GP/GT5C) Cover Gasket (GP/GT14M, GP/GT14L, GP/GT10, GP/GT10L, GP10F) Cover Gasket (GP/GT14) Cover Gasket (GP/GT5C) * Cast stainless steel available as option ** Not shown Cast Iron or Cast Steel* Fabricated Carbon Steel * Cast Iron or Cast Iron or Cast Steel * Cast Steel* Cast Iron or Graphite Compound Graphite/ Fluorine Resin 4 Lever Unit (GP/GT14, GP/GT10 only) 5 Snap-action Unit 6 Intake Valve Unit 7 Exhaust Valve Unit 8 Float 9 Trap Unit 10 Check Valve ** 11 Air Vent Unit** (GT5C only) GT5C shown above GP5C not equipped with trap unit Pump/ Trap: GT10 1 GT Trapping/Filling Cycle When GT inlet pressure is greater than back pressure, the GT acts as a trap, continuously discharging condensate. When inlet pressure is less than back pressure, condensate cannot be discharged, so it accumulates in the body, causing the float to rise. As the float rises, the trap opens, although condensate still cannot be discharged. Exhaust Check Valve Pump: GP10 1 GP Filling Cycle The pump body is equalized to the inlet receiver (usually atmospheric) by the open exhaust valve. This allows condensate to drain by gravity into the pump, where it accumulates and causes the float to rise. Exhaust Check Valve 2 GT Discharge Cycle When the float reaches its highest position, the trap is fully open and the snapaction mechanism actuates, instantly both opening the motive medium intake valve and closing the exhaust valve. The motive medium pressure forces out the condensate, and the float falls. The snap-action mechanism resets, instantly opening the exhaust valve and closing the intake valve. The cycle then repeats. Motive Medium Check Valve 2 GP Discharge Cycle When the float reaches its highest position, the snap-action mechanism actuates, instantly both opening the intake valve and closing the exhaust valve. The motive medium pressure forces out the condensate, and the float falls. The snapaction mechanism re-sets, instantly opening the exhaust valve and closing the intake valve. The cycle then repeats. Motive Medium Check Valve

Systems for Many Different Applications The series meets a variety of condensate processing needs. System Overview Equipment Closed System Power- Trap Exhaust pipe Reservoir recovery line Equipment Equipment Open System Power- Trap Venting pipe Exhaust pipe Discharge to atmosphere Receiver To drain Overflow line recovery line Benefits Notes Approx. Max. Pump Discharge Capacity Model Some Application Examples No need for external steam trap (GT model features built-in trap) No flash steam discharge Small reservoir Use with vacuum equipment possible Only one piece of equipment possible per system Equipment has minimum height requirement to ensure that condensate flows naturally, by gravity (approx.: GP/GT14, GP/GT10-32 ; GP10F - 40 ; GP/GT14M - 14 ; GP/GT14L - 12 ; GP/GT10L - 12 or 20 ; GT5C - 7 ) 17,000 lb/h and less (GT10) 12,000 lb/h and less (GT14) greater than 17,000 lb/h (install pumps in parallel) Mechanical pump with built-in trap GT14/GT10 less than 6,000 lb/h (GT14M) less than 4,000 lb/h (GT14L) Mid-size mechanical pump with built-in trap GT14M/GT14L less than 3,000 lb/h (GT10L) less than 300 lb/h (GT5C) Compact mechanical pump with built-in trap GT10L/GT5C Where there is ALWAYS a negative pressure differential (e.g. vacuum equipment), GP14/GP14M/GP14L/GP10/GP10L/GP10F can be used Large process/ flow, such as: re-boilers, large heat exchangers Small to medium process/flow, such as: room heaters, small to medium heat exchangers Collection of condensate from multiple equipment possible Can be used where trap is lower than receiver, such as equipment situated near grade (providing there is sufficient differential pressure) Separate steam trap required for each piece of equipment Requires venting pipe to discharge flash steam to atmosphere 18,000 lb/h and less (GP10, GP10F) 13,000 lb/h and less (GP14) 18,000 lb/h and greater (install pumps in parallel) Mechanical pump GP14/GP10/ GP10F Large process trap discharges, such as: cylinder dryers, platen presses less than 7,000 lb/h (GP14M) less than 4,500 lb/h (GP14L) Mid-size mechanical pump GP14M/ GP14L less than 3,500 lb/h (GP10L) less than 320 lb/h (GP5C) Compact mechanical pump GP10L/ GP5C Small to medium process trap discharges, such as: recovery: trace lines & mains, small to medium heat exchangers Closed System (GT) Sample Application: Drainage & Recovery from Heat Exchanger Open System (GP) Sample Application: Recovery from an Open Tank Vent line to atmosphere (Pipe Safely) Heat exchanger recovery line Collection of condensate up to 365 F possible Prevents clouds of steam from affecting the work environment Collection of condensate up to 212 F possible Makes it easy to design systems that can easily obtain pressure differential Overflow Line (Pipe Safely to drain) recovery line Pipe all atmospheric discharge to a safe area

(For explanation purposes only, not intended as installation designs.) Closed System Steam supply Pump exhaust Power- Trap Motive medium supply reservoir Air Vent (to atmosphere, pipe safely) Balance Line to Exchanger* To Pit Filling head Height to equipment condensate outlet Back pressure Control valve Heat exchanger Temperature controller recovery line *Consult TLV for assistance. Closed system condensate recovery using a GT PowerTrap Check valve Strainer Gate valve or needle valve Gate valve or ball valve Air vent Steam line Exhaust and air discharge lines line A: outlets may be piped to either the condensate reservoir or the condensate recovery line. Where condensate from the equipment is less than 176 F, it is best to pipe to the condensate recovery line. In closed system applications where steam condensate is pumped, use steam as the motive medium. The height of the condensate outlet on the equipment must be at least: filling head + diameter of reservoir. Please read the instruction manual to ensure safe usage. Open System Steam supply Pump exhaust Motive medium supply Power- Trap Vent line receiver Open vent line (Pipe safely) Zulaufhöhe Filling head Back pressure Overflow line Steam trap Control valve Temperature controller Steam-using equipment Other steamusing equipment recovery line Open system condensate recovery using a GP PowerTrap Pipe the discharge to a safe area such as a pit. Steam line Exhaust and air discharge lines line It is recommended that the equipment condensate outlet be higher than the condensate receiver, in which case a vacuum breaker may also be required. Check valve Strainer Gate valve or needle valve Gate valve or ball valve The vent pipe and overflow pipe should discharge to a safe place. Please read the instruction manual to ensure safe usage.

Installation Piping Example for GT5C * Product Outlet Steam Product Inlet Control Valve Filling Head Specifications Motive Medium Supply GT5C * Actual installation differs depending on the desired discharge capacity and operating conditions, etc. See product specifications data sheet (SDS) for details. Easy Maintenance Inlet/outlet check valves and motive medium intake valve unit are removable while connected to the piping The unit can be disconnected by removing only 2 bolts The body can be disassembled by removing six bolts while still connected to the piping Simple Installation Only motive medium intake pipe - no exhaust pipe necessary Inlet/outlet piping is linear, streamlined and efficient Built-in air vent and check valves minimize external installation 6" Filling Head Usable with low condensate outlet heat exchangers Model GT14 GP14 GT10 GP10 GT14M GP14M GT14L GP14L GT10L GP10L GP10F GT5C GP5C Approx. Max. Pump Discharge Capacity (lb/h) 12,000 13,000 17,000 18,000 6,000 7,000 4,000 4,500 3,000 3,500 18,000 300 320 Approx. Built-in Trap Cap. (lb/h) 80,000 80,000 30,000 27,000 24,000 2,200 16 15 /16 Values attained using a TLV CK3MG (screwed) or CKF5M/CKF3MG (flanged) check valve, unless otherwise indicated. GP/GT5C have a built-in check valve. 15¾ 13 3 /4 10 16 5 1 /2 Dimensions (in) 22 7 /16 27 5 /8 16 7 18 14 3 /16 14 3 /16 30 3 /4 7 1 /16 24 28 5 /8 18¼ 16 1 /8 16 1 /8 18 10 1 /16 12 1 /4 Connection * 1 S F S F S F S F F S F S F S S Body Cast Iron 280 273 280 273 190 198 124 122 101 99 44 44 Material Carbon Steel Cast Steel 306 328 300 322 306 328 300 322 205 207 110 108 & Weight 154 (lb) Cast 40 40 Size (in) Pumped Med. Inlet 3 2, 3 3 2, 3 3 2, 3 3 2, 3 1 1 /2 1, 1 1 /2 1 1, 1 1 /2 1 3 1 Pumped Med. Outlet 2 1 1 /2 1 2 1 Motive Med. Inlet 1 1 /2 3 /4 1 /2 Pump Exhaust Outlet 1 1 /2 1 3 /8 Max. Oper. Press. PMO 200 psig 150 psig 200 psig 150 psig 75 psig Max. Oper. Temp. TMO 392 F 365 F 428 F 365 F 428 F 365 F Max. Allow. Press. PMA 200 psig (C.I.) * 2, 230 psig (C.S.) * 2 230 psig (C.I.) * 2, 300 psig (C.S.) * 2 150 psig Max. Allow. Temp. TMA 428 F 428 F (C.I.) * 2, 500 F (C.S.) * 2 428 F 650 F 428 F Motive Med. Press. 100-200 psig 5-150 psig 5-200 psig 5-150 psig 5-75 psig Max. Allow. Back Press. 150 psig * 3 143 psig * 3 193 psig * 3 143 psig * 3 68 psig * 3 Motive Medium * 4 GT Series : Saturated Steam GP Series : Saturated Steam, Compressed Air, Nitrogen Pumped Medium * 5 GT Series : Steam GP Series : Steam, Water Filling Head * 6 (in) Standard 36 Minimum 30 * 1 S = screwed, F = flanged * 2 C.I. = cast iron, C.S. = cast steel * 3 Motive medium pressure minus back pressure must be greater than 7 psi * 4 Do not use with toxic, flammable or otherwise hazardous fluids. * 5 Do not use for fluids with specific gravities under 0.85 or over 1, or for toxic, flammable or otherwise hazardous fluids. * 6 Measured from grade. * 7 At 15 psig back pressure, per 1,000 lb condensate. * 8 Equivalent consumption of air at 68 F under atmospheric pressure. Full product details (sizes, pressures, capacities and materials) are included in the individual specification data sheets (SDS). Std. 25 Min. 14 Std. 25 Min. 12 Std. 25 Min. 18 (12 w/ CKF5M) Steam/Air Consumption * 7 1.7 lb steam,96 ft³ compressed air * 8 (GP Series) 2 lb steam,100 ft³ air * 8 Std. 42 Min. 33 Min. 6 1 /4 To avoid abnormal operation, accidents or serious injury, DO NOT use this product outside of the specification range. Local regulations may restrict the use of this product to below the conditions quoted. DO NOT DISASSEMBLE OR REMOVE THIS PRODUCT WHILE IT IS UNDER PRESSURE. Allow internal pressure of this product to equal atmospheric pressure and its surface to cool to room temperature before disassembling or removing. Failure to do so could cause burns or other injury. READ INSTRUCTION MANUAL CAREFULLY. 13901 South Lakes Drive, Charlotte, NC 28273-6790 Tel: 704-597-9070Fax: 704-583-1610 E-mail: tlv@tlvengineering.comhttp://www.tlv.com For Technical Service 1-800 TLV TRAP Copyright C Pamphlet A2404 Rev. 8/2017 (O) Specifications subject to change without notice.