The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

Similar documents
DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

DH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS. OPTIONAL ACCESSORIES Two Row Hot Water Coil

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

Advance Release September 2009

Cooling/Heat Pump Convertible Air Handlers

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Condensing Units & Air Handlers

Product Specifications. Vertical Floor Consoles By First Co.

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

MAC N-407 Air-Cooled Chiller

TECHNICAL SPECIFICATIONS

SKYPAK II Heating & Cooling Self Contained Packages

RSG16**S1M. Split System Air Conditioner 16 SEER

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

TECHNICAL SPECIFICATIONS

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

Vertical Upflow Horizontal Left Air Handlers

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

CWA4 Chilled & Hot Water Fan Coil

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

Technical Data Manual Model Nos. and pricing: see Price List

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

KIC Air Curtains. Technical Guide

FCC Fan-Coil Units High-Performance, Vertical

VERTICAL FAN COIL UNITS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

MACH N-407 Heat Pump Air-Cooled Chiller

36,000-62,000 BTUH Nominal Capacity

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER

COMMON WATERSIDE ECONOMIZER APPLICATIONS:

Modular Multi-position Air Handler

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Commercial High-Efficiency Condensing Units

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

"SWVP - SWHP" COMMERCIAL WATER SOURCE HEAT PUMPS & AIR CONDITIONERS

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

technical guide Water-Cooled Self-Contained Units

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

Horizontal and Vertical DIRECT DRIVE BLOWER COIL UNITS. Rating and selection at

1.1 This section applies to air handling units for HVAC Systems.

Modular Heating & Ventilating Unit Model IGX-HV

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Split System Heat Pumps

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

Modular Supply Make-Up Air Unit

catalog CDV Fan-Coil Units High-Performance, Vertical

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

VertiCool Aurora Engineering Guide

FILTERS MANIFOLD CABINET REFRIGERANT CONNECTION LOCATION

Service Facts. Air Handler - Convertible Model: Series 2 Air Handlers ton GAT2A0B42S31SA GAT2A0C48S41SA GAT2A0C60S51SA WARNING: GAT2-SF-1B

C13-Series Engineering Guide

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

SSL & SBS Engineering Guide

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

Water-Cooled Self-Contained Units

PRODUCT CATALOG BLOWER COILS.

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.

STULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

PACKAGE AIR CONDITIONER

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

PRODUCT SPECIFICATIONS

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

Transcription:

Producing Quality Heating & Cooling Equipment For Over 50 Years DUW/DUX SERIES 1.5 THROUGH 5 TON VERTICAL OR HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat MAGIC AIRE DU SERIES FAN COILS ARE ETLC LISTED IN ACCORDANCE WITH UL 1995 AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. United Electric Company, L.P. 501 Galveston St. Wichita Falls, TX 76301 940-397-2100 Fax: 940-397-2166 www.magicaire.com DUW/DUX 1.0 PI 08/05 3M 1 DUW/DUX 1.0

DU SERIES Magic Aire DUW/DUX Series fan coils are designed for upscale homes, apartments and condominiums. Engineered with the distributor and installer in mind, one unit satisfies all demands. Additional features include: DUW 1" throwaway filter Three speed motors w/ thermal overload protection Hot Water Coils (Capacity to 124,000 BTU/H) with optional 115v pump assembly 3 and 4 row water coils Electric heating elements to 20KW Multiple access panels for easy servicing All metal parts are fabricated from heavy gauge galvannealed steel w/ polyurethane coating for the best finish in the industry All interior surfaces are fully insulated w/material to comply w/nfpa 90A and 90B Low RPM oversized fans are balanced for quiet, vibration free operation 24v transformer and fan relay DUX SEER Ratings to 13+ 24v 40 VA transformer and relay(s) 1" throwaway filter Two speed motors w/ thermal overload protection Hot Water Coils (Capacity to 124,000 BTU/H) with optional 115v pump assembly 3 and 4 row copper tube/aluminum fin DX coils to match most heat pump condensing units have piston metering refrigerant control Multiple access panels for easy servicing All metal parts are fabricated from heavy gauge galvannealed steel w/polyurethane coating for the best finish in the industry All interior surfaces are fully insulated w/material to comply w/nfpa 90A and 90B Low RPM oversized fans are balanced for quiet, vibration free operation 2

DU SERIES The Premium Quality, High Seer Combination Fan Coil Units for Vertical and Horizontal Application with Hydronic or Electric Heat All From One Unit! Horizontal Right Hand Vertical Upflow Horizontal Left Hand Magic Aire DU Series Fan Coils are designed for upscale homes, apartments, and condominiums. Engineered with the distributor and installer in mind, one unit satisfies all demands. Information subject to change without notice. 3 DUW/DUX 1.0

DUW UNIT DIMENSIONAL INFORMATION STANDARD ONE PIECE CABINET (Cooling & Heating) RETURN TOP VIEW (Hot Water Heat Unit) SUPPLY NOTES: (1) Dimensions F, H, and K are for no heat and hydronic heat units. Dimensions G, J, and L apply to electric heat units only. (2) Return air openings Side return air openings require field modification. (3) On 60-DU electric heat units 1/2HP-230v-1ø. (4) Hot Water Pump Module (not shown) is 115v (.52 FLA). TWO PIECE CABINET KNOCKOUT FOR ELECTRICAL CONNECTIONS (BOTH SIDES) KNOCKOUT FOR ELECTRICAL CONNECTIONS (BOTH SIDES) OPTIONAL RIGHT OR LEFT SIDE RETURN (FIELD MODIFICATION W/SIDE RETURN FILTER KIT) HOT WATER COIL & PUMP MODULE/ ELECTRIC HEAT ACCESS PANEL BLOWER/MOTOR ACCESS PANEL SUPPLY RETURN OPTIONAL HOT WATER OR ELECTRIC HEATER SECTION FOR FIELD INSTALLATION COOLING SECTION PRIMARY & SECONDARY DRAIN CONN. 3/4" NPT FILTER ACCESS PANEL LEFT VIEW FRONT VIEW RIGHT VIEW 4

AIRFLOW DATA DUW-B SERIES FAN COIL CFM @.00".50" ESP NOTE: All data assumes dry cooling unit. UNIT ELECTRICAL INFORMATION NOTE: 10, 15 & 20KW require 2 supply circuits. Entering Air Temp (F) HOT WATER HEATING CORRECTION FACTORS Entering Water Temp (F) o o 100 110 120 o o 130 140 o o 150 160 o o 170 80 50 o. 419. 500. 579. 665. 742. 838. 917 1.000 1.090 55 o. 376. 460. 544. 629. 708. 791. 873. 963 1.048 60 o. 335. 419. 500. 579. 665. 742. 838. 917 1.000 65 o. 290. 376. 460. 544. 629. 708. 791. 873.963 70 o. 251. 335. 419. 500. 579. 665. 742. 838.917 75 o. 205. 290. 376. 460. 544. 629. 708. 791.873 80 o. 167. 251. 335. 419. 500. 579. 665. 742.838 5 DUW/DUX 1.0 1 o

DUWB-3 Coil Capacities 060-DUWB-3 048-DUWB-3 024-DUWB-2HW 036-DUWB-3 024-DUWB-3 2 Row Heating 3 Row Heating 024-DUWB-3HW 6 036-DUWB-2HW 036-DUWB-3HW

DUWB-4 Coil Capacities LWT LWT LWT 060-DUWB-4 048-DUWB-4 036-DUWB-4 048-DUWB-3HW 024-DUWB-4 3 Row Heating 4 Row Heating 048-DUWB-4HW 060-DUWB-3HW 7 DUW/DUX 1.0 060-DUWB-4HW

DUX SERIES Unit Dimensional Information 8

DUX SERIES Airflow Data DUX-B Series Fan Coil CFM @.00".50" ESP NOTE: 9 DUW/DUX 1.0

DUX SERIES Direct Expansion Coil Cooling Capacities Hot Water Coil Heating Capacities NOTES: 1. IMPORTANT When application calls for DUX series used in conjunction with a heat pump, contact factory for ratings and to confirm compatability with specific outdoor unit models. 2. DX cooling capacities are computer generated evaporator ratings based on specific entering conditions listed in the table. Actual performance with different condensing units may vary. 3. Contact factory for S.E.E.R. ratings with most major manufacturers' condensing units. 10 4. When ordering DUX series units with hydronic heat, specify whether pump module is required, and if so, whether it is required factory installed or shipped separately as a kit (See LIST PRICES for details). 5. Contact the factory for wiring diagrams of all unit combinations. 6. Due to continuous efforts to improve our products, all specifications subject to change without notice.

DUX SERIES MULTI-FUNCTION CONTROLLER Description DUX series multi-position air handlers are available with a Multi-Function Controller that reduces the number of electrical connections and field supplied parts required to install these units with boilers, pumps and condensing units. Heating: Air handlers can now be directly wired from the boiler to the air handler without adding additional relays or related controls. Multiple air handlers may be connected to a single, highefficiency natural gas or oil fired hot water boiler to provide complete, whole house hydronic space heating. Each air handler includes a high-efficiency cooling coil, a separate hot water coil, drain pan,115, 208, 230 volt three speed blower motor, throwaway filter and a 24V transformer. Cooling: These air handlers are completely compatible with all split system type condensing units. Cooling coils in the DUX-HW air handlers are extra-large and engineered to offer cooling efficiencies to 13 SEER, depending on the condensing unit used. Features Include: Diagnostic Indicator Lights 100% Factory Tested Automatic Multi-Speed Switching Prevents False Calls for Fan Operation Simplified Wiring Universal Thermostat Compatibility Contractor Friendly PC Board Layout Increased Operating Efficiency Available in 115, 208, 230 volts Made in USA DX Cooling / Boiler Heating Heating Cycle 1. Boiler Start Relay: Eliminates field installed boiler relay, allowing direct wiring from the boiler to the air handler. 2. Heating Cycle Blower Delay: User selectable 1, 3, or 4 minutes delay of the blower start to allow the coil to be preheated before the blower energizes. Cooling Cycle 1. Cooling Cycle Blower Delay: Maximizes cooling efficiency by allowing the blower to run 1 to 100 seconds after the thermostat is satisfied. 2. Horizontal Drain Pan: Factory installed. (re-positions within cabinet for right-to-left airflow) 3. Drain Connections: Primary and secondary on cooling coil. Optional Features 1. Freeze Protector: (Optional freeze protector switch required) Reduces the possibility of the water coil freezing by switching the pump on if the water temperature is nearing a freezing condition. 2. Aquastat: An optional aquastat is an available feature that ensures that there is hot water available prior to fan start up. Additional Standard Features 1. The diagnostic lights show full functionality of the Fan Control. The green light should always be on indicating that power is connected. Red lights indicate fan operation for heating and cooling modes. 2. Pump dry contact activated for 2 minutes every 24 hours (boiler contacts not activated). User selectable. 3. Pump dry contacts activated for 30 seconds every two weeks (boiler contacts not activated). User selectable. 4. Compatible with most major brands of split condensing units. 11 DUW/DUX 1.0

ENGINEERING SPECIFICATIONS Cabinets shall be fabricated of LFQ (min) steel. External parts are to be made with a polyurethane based powder coated heavy gauge galvanealed, while internal parts are to be built from heavy gauge galvanized steel. Units shall pass 500 hour salt spray test as described in ASTM B-117 Coils are to be tested at 500 PSI for operation at 400 PSI guage. All water coils have air vents. Fan wheel bearings shall be self aligning, sealed cartridge, permanently lubricated ball bearings that provide dependable fan operation for an average life of 200,000 hours (belt drive only). Variable pitch motor sheaves. United Electric Company designs and builds its Magic Aire products to comply and perform to one or more of the following standards: COIL AIR FLOW CAPACITY General Belt Drive Equipment Direct Drive Equipment Hydronic Direct Expansion AMCA 210 ASHRAE 51 ARI 430 ARI 440 ARI 410 ARI 210 IN DUCT SOUND RATINGS Air Moving Equipment ASHRAE 68 AMCA 330 SAFETY MATERIAL AGENCY LISTINGS SPECIFICATIONS MAJOR COMPONENTS Coils UL Report # Equipment ETL Report # Sheet Metal Copper Tubing Aluminum Motors Wire Electrical Filters Fiberglass Paint UL 207 SA 3438 CAN/CSA C22.2 #236 ANSI/UL-1995 491893 ASTM A525 ASTM A527 ASTM B68 ASTM B75 ASTM B88 ASTM B251 ASTM B209 UL/CSA NEMA UL/CSA UL/CSA UL ASHRAE 52 UL 181 UL 723 (25/50) ASTM E-84 ASTM B117 MAGIC AIRE DU SERIES FAN COILS ARE ETLC LISTED IN ACCORDANCE WITH UL 1995 AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. United Electric Company, L.P. 501 Galveston St. Wichita Falls, TX 76301 940-397-2100 Fax: 940-397-2166 www.magicaire.com DUW/DUX 1.0 12 PI 08/05 3M