HRU-MinistAir-W-250. Equipment & accessories. Heat recovery units. Dimensions. Description

Similar documents
HRU-MinistAir-W-450. Elementy dachowe. Heat recovery units. Dimensions. Description. Control. ALNOR systemy wentylacji

Auxiliary Equipment and Accessories

Heat and energy recovery ventilators

User manual for HRU-MinistAir-W-450 heat recovery units. Wi-Fi control for the HRU-MinistAir-W-450 heat recovery unit

KOMFORT EC DB Suspended heat recovery air handling units

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

SEQUENCE OF OPERATIONS

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

Healthy, comfortable and energy-efficient ventilation

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

TSEK VHR EC HEAT RECOVERY UNITS

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h

Healthy, comfortable and energy-efficient ventilation

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

DEMAND CONTROLLED HOME VENTILATION HCC 2 Designed to suspended ceiling installation

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

Small Room Heat Recovery Ventilation

SINGLE-ROOM VENTILATION. for schools and public spaces

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

Lo-Carbon Sentinel Kinetic Horizontal

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Air to Air Heat Exchanger

VENTILATION. Effective heat exchange and fresh air ventilation

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

AIR HANDLING UNITS. AmberAir Compact Smarty RIS EKO 3.0 RIRS EKO 3.0

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

VEX100 series Air handling units with cross-flow heat exchanger

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

Sentinel Demand Energy Recovery Ventilation

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS

HRV Brochure. Heat Recovery Ventilation

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

DOMESTIC LINE DUPLEX EASY

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

The Sentinel Kinetic Horizontal Range

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

145SE. Vallox. Operating, maintenance and technical instructions

Manual. Document ENG

Lo-Carbon Sentinel Kinetic Range Overview

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

096SE. Vallox. Operating, maintenance and technical instructions

Operation and maintenance instructions

MODEL: BV400 Part No:

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

Swegon CASA R120. Instructions for installation, operation and maintenance. R120_h_EN-m

VENTILATION WITH HEAT RECOVERY

Energy recovery unit. Projection documents

Vallox INSTRUCTIONS FOR USE AND MAINTENANCE. Compact. Supply and extract air ventilation with heat recovery

Technical Information HXV - HRV Ventilation

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

InspirAIR Home RESIDENTIAL AIR PURIFICATION

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

Heat Recovery Air Handling Units

Heat recovery unit. Installation Manual

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

HRXD MVHR UNIT Mechanical Ventilation with Heat Recovery.

The new Xcell EC High Efficiency Range Fresh air pure and simple

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

Residential-Use Lossnay

Ventilation Unit Zehnder ComfoAir 350

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

Lo-Carbon Sentinel Kinetic Range Overview

CI/SfB (57.7) 2nd edition

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

250mm dia straight pipe length SP4 SP3. Air volume

Ventilation Product range ADVANCE ECO 4 ECO 2

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

COUNTER-FLOW, HIGH-EFFICIENCY HEAT RECOVERY UNIT IDEO ECOWATT

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

Indirect Evaporative Air Conditioning

Intelligent Air Solutions

Swegon CASA R85. Ventilation unit with rotary heat exchanger HOME VENTILATION

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

CI/SfB (57.5) November 2008

Indirect Evaporative Air Conditioning

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

Models Vallox 096 MC R Vallox 096 MC L. Document D2609 MANUAL. Valid from Type Updated Manual.

Endura Delta. Demand- and app-controlled ventilation system with heat recovery

VALLOX VENTILATION PRICELIST 2018

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Control System Structure

HEAT RECOVERY UNITS TSEK. Mech-Elec, 41, Hawthorn Road, Western Ind. Est., Dublin 12 Tel:

Flexit air handling units UNI 2, 3 og 4

TURBO HOODS. Product Brochure

Transcription:

Heat recovery units Description www.alnor.com.pl Dimensions Ø 125 600 660 702 Podręcznik użytkownika rekuperatorów is the smallest heat recovery unit in the range of MinistAIR products. With a total air supply output of 220 m 3 /h, the unit can be installed in small indoor areas which will benefit from a compact footprint and Elementy low weight składowe of the product. Centrale wentylacyjne są przeznaczone do odzyskiwania części energii z powietrza wylotowego w uk Key performance features: wentylacyjnym. Odzyskana energia jest przekazywana bezpośrednio do dostarczanego świeżego powietrza, co pozwala ogr Maximum heat recovery ratio 85.8%, tested as zyć per obciążenie EN 308 układu klimatyzacji. by TÜV SÜD Plastic counter-flow heat exchanger Design Automatic air flow bypass Freeze protection BMS connectivity (via Modbus) Preheater and secondary heater control connectivity 5 Programmable week control timer Filter clogging monitor 4 Class G4 filters in standard (class F7 filters available on request) Supported sensor typees: CO 3 2, RH, and pressure switch Wall-mounted or free-standing Metal duct connections with EPDM gaskets for air tightness class D EBM PAPST energy-efficient fans 380 400 Control When ordering, specify the control type. There are two versions of control available - wired and wireless: - with a wired controller W - with Wi-Fi control 1 6 2 1. Control 2. Air supply & exhaust filters 1 Sterowanie 3. Damper actuator 4. Counter-flow heat exchanger Filtry powietrza wylotowego 2 5. Housing i nawiewanego 6. Air exhaust & supply fans 3 Siłownik przepustnicy 4 Wymiennik przeciwprądowy 680 5 6 Obudowa Wyciągowy i nawiewny

Heat recovery units Technical specifications 350 300 Air flow rate (m 3 /h) * 220 Rated power supply (V/Hz/Ph) 230 / 50 / 1 Maximum power consumption (W) 112 Maximum sound pressure level (db (A)) ** 46 Weight (kg) 24 Filters * The static pressure is 100 Pa. ** Measured 1 m away from the unit. Performance curve Class G4 filter as per EN 779 (class F filter available on request) 250 Static pressure (Pa) 200 150 100 50 0 0 50 100 150 200 250 300 Air flow rate (m 3 /h) 681

Rekuperatory Technical specifications Sound level chart Octave sound pressure level (db: general A) Frequency 682

Heat recovery units Technical specifications The air tightness was tested per EN 308. The air leak rate was measured at an air flow rate of 221 m 3 /h and an air pressure of 100 Pa. The following table lists the internal and external air leak rates and percentage vs. the overall air flow rate: Test No. P stst (Pa) Air leak rate (m 3 /h) Inner air leak Percentage ratio (%) Air leak rate (m 3 /h) Outer air leak Percentage ratio (%) 1-400 2.4 1.1 2-300 1.9 0.8 2.8 1.3 3-250 1.6 0.7 4-200 1.3 0.6 2.1 0.9 5-100 0.7 0.3 1.3 0.6 6-50 0.4 0.2 0.7 0.3 7 0 0.0 0.0 0.0 0.0 8 50 0.3 0.2 0.7 0.3 9 100 0.6 0.3 1.2 0.5 10 200 1.2 0.5 2.0 0.9 11 250 1.4 0.6 12 300 1.7 0.7 2.7 1.2 13 400 2.1 0.9 The thermodynamic test was completed as per EN 308. The following temperature coefficients were measured for the heat recovery unit: 4 V 6V 8V 10 V Supply air q m2 [m 3 /h] 40 113 151 226 Exhaust air q m1 [m 3 /h] 40 114 153 230 Static pressure (supply) [Pa] 49 50 96 98 Static pressure (exhaust) [Pa] 48 47 95 96 Supply temp. recovery ratio eta t,sup [%] 87 85 83 80 Exhaust temp. recovery ratio eta t,eha [%] 71 76 75 74 Mean temp. recovery ratio eta t,epb [%] 79 80 79 77 683

Heat recovery units Energy class B 57 db 220 m 3 /h ENERGIA ЕНЕРГИЯ ΕΝΕΡΓΕΙΑ ENERGIJA ENERGY ENERGIE ENERGI 2016 1254/2014 684

Heat recovery unit controller manual controller HRU-MinistCONT-Man Function Description Availability Fan speed control Fan speed boost Filter clogging indicator Automatic air flow bypass Electric heater control Sensor (VOD) Sensor (Humidity) Freeze protection Preheater control BMS connectivity Modbus connectivity Programmable week control timer Air supply and air exhaust fans are provided with a 3-speed control system. This function increases the fan speed: Option 1: Press the BOOST button on the control panel Option 2: Activated with an external dry relay input or an external 230 V input (activated e.g. by a lamp switch in the kitchen, bathroom, etc.) on the controller s PCB. Two filter clogging indicator options: Option 1: The filter clogging indicator counts down the unit's operating time to a preset value. When the preset value is reached, a filter change request indicator is activated on the control panel. Option 2: Filter clogging can be monitored with a pressure switch. When the filter reaches the clogging limit, the pressure switch activates a filter change request indicator on the control panel. The filtered fresh air is supplied indoors, bypassing the heat exchanger. The interfaced electric heater can have the output automatically switched between a maximum of 2 levels the selection of which depends on the desired temperature setting and the actual indoor temperature. The fans are operated continuously by the control output of a CO2 sensor or an air quality sensor. The fans are operated continuously by the control output of an indoor air humidity sensor. If the outdoor temperature is low, the freeze protection function is activated to protect the heat exchanger from freezing. If the outdoor temperature is low, the fresh air supply is treated by a preheater upstream of the unit. This function protects the heat exchanger from freezing. IN: The unit can be turned on and off using an external control panel. OUT 1: Unit status output OUT 2: Unit fault alarm output This feature allows operating all controls of the unit via a PC or a central automation system. The unit can be programmed to operate at specific hours in a weekly cycle. 3 speeds (all fans) (High / Medium / Low) Optional Optional Optional Data logging This function allows logging all available operating options of the unit. Fire mode This function activates a special operating status in the case of a fire alarm. Alarms - Filter change required - Fan failure - Preheater failure - Heater failure (Error code display) Child lock Locks the control keypad to prevent inadvertent operation. 690

Heat recovery unit controller HRU-MinistCONT-WiFi controller Kontroler HRU-MinistCONT-WiFi umożliwia zdalne starowanie centralami rekuperacyjnymi z serii HRU-MinistAIR - oznacza to, że z dowolnego miejsca na świecie możesz wybrać rodzaj trybu pracy centrali rekuperacyjnej odpowiadający Twoim aktualnym potrzebom w zakresie jej funkcjonowania. Wraz z zakupem centali, dokupując HRU-MinistCONT-WiFi otrzymujesz zainstalowaną puszkę sterującą wraz z adresem internetowym oraz danymi do zalogowania się i obsługiwania zdalnie Twojej centrali. Function Description Availability Fan speed control Fan speed boost Filter clogging indicator Automatic air flow bypass Electric heater control Sensor (VOD) Sensor (Humidity) Freeze protection Preheater control BMS connectivity Modbus connectivity Programmable week control timer Air supply and air exhaust fans are provided with a 3-speed control system. This function increases the fan speed: Option 1: Press the BOOST button on the control panel Option 2: Activated with an external dry relay input or an external 230 V input (activated e.g. by a lamp switch in the kitchen, bathroom, etc.) on the controller s PCB. Two filter clogging indicator options: Option 1: The filter clogging indicator counts down the unit's operating time to a preset value. When the preset value is reached, a filter change request indicator is activated on the control panel. Option 2: Filter clogging can be monitored with a pressure switch. When the filter reaches the clogging limit, the pressure switch activates a filter change request indicator on the control panel. The filtered fresh air is supplied indoors, bypassing the heat exchanger. The interfaced electric heater can have the output automatically switched between a maximum of 2 levels the selection of which depends on the desired temperature setting and the actual indoor temperature. The fans are operated continuously by the control output of a CO2 sensor or an air quality sensor. The fans are operated continuously by the control output of an indoor air humidity sensor. If the outdoor temperature is low, the freeze protection function is activated to protect the heat exchanger from freezing. If the outdoor temperature is low, the fresh air supply is treated by a preheater upstream of the unit. This function protects the heat exchanger from freezing. IN: The unit can be turned on and off using an external control panel. OUT 1: Unit status output OUT 2: Unit fault alarm output This feature allows operating all controls of the unit via a PC or a central automation system. The unit can be programmed to operate at specific hours in a weekly cycle. 3 speeds (all fans) (High / Medium / Low) Optional Optional Optional Data logging This function allows logging all available operating options of the unit. Fire mode This function activates a special operating status in the case of a fire alarm. Alarms - Filter change required - Fan failure - Preheater failure - Heater failure (Error code display) Child lock Locks the control keypad to prevent inadvertent operation. 691

Heat recovery unit controller HRU-MinistCONT-Wifi Controller Login panel: All users receive their personal user names and passwords for remote access to the device they purchase. Alnor ventilation controller configuration pane: The wizard's steps guide the user through the commissioning and local network configuration of the device. Heat recovery unit start and stop: ON / OFF 692

Heat recovery unit controller HRU-MinistCONT-Wifi Controller Heat recovery unit work mode selection: adjust the continuous operation of the unit to your needs, or use the predefined options as follows: STANDARD MODE: continuous air change. Enables work mode selection for the AIR SUPPLY fan and the AIR EXHAUST fan. AIR EXHAUST MODE: controls the air exhaust fan only. Fan work modes: speed 1, 2, 3 or OFF. Start the function to extract stale air from the area and return to the air change mode by selecting STANDARD. 693

Heat recovery unit controller HRU-MinistCONT-Wifi Controller AIR SUPPLY MODE: controls the air supply fan only. Fan work modes: speed 1, 2, 3 or OFF. Start the function to supply fresh air indoors and return to the air change mode by selecting STANDARD. VOD MODE: in the Ventilation On Demand mode, the air supply and air exhaust rates depend on the humidity readout from the optional indoor air humidity sensor connected to the heat recovery unit. The sensor is sold separately. Remote temperature setting: choose the indoor temperature for the room. Indoor air temperature: shows the actual temperature of the air exhausted from the area, which is changed by the controller via the heat recovery system to match the remote temperature setting. The outdoor air intake temperature. The temperature of the air supplied by the heat recovery unit to the area. 694 Alarm code: displays the error code of the heat recovery unit. (See the error code definitions in the User Manual.) BY-PASS FUNCTION: the heat recovery unit supplies fresh and filtered outdoor air bypassing the heat exchanger. When this indicator is checked, the By-Pass Mode is running. ONLINE: shows the status of the data connection between the controller and the heat recovery unit. When this indicator is lit, the data connection is correct.

Heat recovery unit accessories F7 filter EU4 filter EU7 (F7) filter elements are fine filters with the rated separation efficiency at 80 90% for 0,4 µm particulates. Product code Filter class Dimensions (mm) HRF-Mair-250-F7 F7 150x360x30 HRF-Mair-400-F7 F7 215x605x45 Product code Filter class Dimensions (mm) HRF-Mair-250-EU4 EU4 150x360 HRF-Mair-400-EU4 EU4 215x605 Humidity sensors An air humidity sensor can operate a heat recovery unit by regulating the air fan speed via its output signals. The air fan is switched between three 3 speeds which correspond to air humidity presets. H7015B1060 duct air humidity sensor Maintenance-free and automatic humidity and temperature measurement Power supply Humidity measurement range Output signal Temperature measurement range Protection rating Wiring length 24 V 0 to 100% RH 1 to 10 V 0 to +50 C IP65 200 m 695

Heat recovery unit accessories T7560C1006 room air humidity sensor CO 2 sensors Automatic humidity and temperature measurement Power supply Humidity measurement range Output signal Temperature measurement range Protection rating Sensor typee CO 2 (carbon dioxide) sensors allow regulating -W-450 heat recovery units according to the indoor or duct CO 2 concentration levels (depending on where the sensor is installed). 24 V 10 to 95% RH 1 to 10 V +6 to +40 C IP30 20 kω NTC AQS71-KAM-T duct CO 2 sensor Maintenance and calibration free Power supply Test Measurement accuracy Temperature measurement range Output signal 24 V 0 to 2000 ppm +/- 50 ppm 0 to +50 C 1 to 10 V C7110D1009A room CO 2 sensor Automatic humidity and temperature measurement Self-calibration algorithm Power supply Test Measurement accuracy Temperature measurement range Output signal Sensor typee 24 V 0 to 3000 ppm +/- 50 ppm 0 to +50 C 1 to 10 V 20 kω NTC 696