A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

STANDARD TEST PROCEDURE PRE-TEST QUALITY OF OPTIC FIBRE CABLE ON DRUMS TYPE OF CABLE :

This is a preview - click here to buy the full publication

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Special Provision No. 683S28 December 2017

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010

AS/NZS ISO/IEC :2012

ASSMANN ELECTRONIC GmbH ASSMANN SYSTEM GUARANTEE. DIGITUS Professional Fiber Optic Cabling System. Appendix B - Provisions for acceptance

Draft ES V1.1.1 ( )

Fibre Specification Standards

4120 Fire Alarm Network Reference

The Rise of Tier 2 Testing

OTDR II. Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling

LAB REPORT SUBMISSION COVER PAGE ETN4106 OPTOELECTRONICS AND OPTICAL COMMUNICATIONS

SECTION TESTING OF FIBER OPTIC CABLES

MT-RJ Optical Fiber System Field Testing

FACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014)

SECTION TESTING OF FIBER OPTIC CABLES

FTS500 Series. Handheld OTDR Test Set.

ETSI TS V1.2.1 ( )

EXECUTING HIGHLY ACCURATE FIBER MEASUREMENTS IN A FRACTION OF THE TIME

OPTICAL TIME-DOMAIN REFLECTOMETER

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

HELKAMA. Optical Fibre Cables

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

OTDR - FHO5000-xxx. Optical Time Domain Reflectometer

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

MTTplus Modular Test Platform

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Fiber Optics for Todays Industry Applications

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES

INTERNATIONAL STANDARD

M-Series Compact OTDRs User s Guide

Product Specification Qualification Test Report

Fibre Optic Basics FIA Summer Seminar 2014

OptiFiber Pro OTDR Built for the enterprise

FTS510 Series. Handheld OTDR Test Set.

VIEW500 USER-FRIENDLY STANDARD OTDR

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

ECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS

FLX380-30x FlexTester OTDR

Certified Fibre Optic Specialist - Testing

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

OptiFiber Pro OTDR Built for the enterprise

TESTING HIGH SPEED FIBER LINKS

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

Field Test Procedure for Optical Fibre Link Measurements

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

TECHNICAL REPORT IEC/TR Fibre optic communication system design guides Part 11: Multimode launch conditions. Edition 1.

Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis

INTERNATIONAL STANDARD

OPTICAL TIME DOMAIN REFELECTOMETER (OTDR): PRINCIPLES

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

GAMMA OTDR application consists of main window and menu. Using menu user can operate in different modes of application.

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

MINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR

The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise

Datasheet: OptiFiber Pro OTDR

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

VIEW500 FASTEST STANDARD OTDR

M700-Series Multifunction OTDR

This document is a preview generated by EVS

Duct Cable GYTS-144B1.3

Designed for Enterprise Fiber

M310 Data Center OTDR

PRO Android OTDR. Android Enabled OTDR. For Use With: PRO-2, PRO-3, PRO-FBE-300

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Transmission media and optical systems characteristics Optical fibre cables

MINI2 MOST ACCURATE COMPACT OTDR

MicrOTDR. Optical Fault Locator. User Manual

ACCESS Master MT9085 Series. Product Introduction

Ensuring Cabling Performance in the Customer-Owned Outside Plant

infrastructure for 10, 40 and 100Gbits/s readiness

Basic Professional Fiber Optic Installation

FLX380 and OFL280 FlexTester Series

Noyes OFL 250B Specs Provided by

Datasheet: OptiFiber Pro OTDR

Datasheet: OptiFiber Pro OTDR

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

iotdr Series Portable OTDR Test Set iotdr Series OTDR Tester is entirely new portable product released by OPWILL.


OPX-350 Series. Fiberizer Cloud. Universal Performer for Fiber Testing. Add value with. Test and Measurement in Fiber Optics

Hands-On CAT 5/6 & Fiber Optic Installer

STAND OUT FROM THE CROWD. Bisham Abbey, 14th May 2002 INTRODUCTION. Work Smart FIA. The Fibreoptic Industry Association STAND OUT FROM THE CROWD

A Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification

Terahertz Technologies Inc Fiber Optic Test Equipment Catalog

Yokogawa Meters & Instruments Releases AQ1200E, AQ1205A, AQ1205E, and AQ1205F OTDR Multi Field Testers

AQ7275 OTDR Optical Time Domain Reflectometer

A Quick Start Guide to Fiber-to-theAntenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification

DR-500 Series Handheld OTDR User Guide

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

Telephone and Data Structured Wiring

Transcription:

December 5th, 2017 Acceptance Requirements Fibre Optic Systems Revised 12/2017 Alexander Kölbel +49 6190 8880-40 alexander.koelbel@datwyler.com Dätwyler Cables GmbH, Auf der Roos 4-12, 65795 Hattersheim, Deutschland T +49 6190 8880-0, F +49 6190 8880-80, info.cabling.de@datwyler.com, www.cabling.datwyler.com Dätwyler Cables GmbH, Lilienthalstraße 17, 85399 Hallbergmoos, Deutschland T +49 811 998633-0, F +49 811 998633-30, info.cabling.de@datwyler.com, www.cabling.datwyler.com Dätwyler Cables GmbH, Niederlassung Österreich, Liebermannstraße A02 403, 2345 Brunn am Gebirge, Austria T +43 1 8101641-0, F +43 1 8101641-35, info.cabling.at@datwyler.com, www.cabling.datwyler.com Geschäftsführer / Managing Directors: Ralf Klotzbücher, Johannes Müller HRB 84724, Amtsgericht Frankfurt am Main, UST-ID-Nr. DE128947927 / ATU63707901

Content 1 Scope... 3 2 General requirements... 3 3 Approved measuring instruments... 3 4 Calibration of measuring instruments / measuring adapter... 3 5 Increase of the reflection loss... 3 6 Permitted attenuation values for installation sections... 4 6.1 Permanent link with spliced single-mode installations... 4 6.2 Permanent link with spliced multimode installations... 4 6.3 Permanent link with pre-assembled single-mode installations... 5 6.4 Permanent link with pre-assembled multi-mode installations... 5 7 Measuring direction... 6 8 Connectors of the test setup... 6 9 Test cables... 6 10 Visual inspection... 6 10.1 Cleaning connectors and connectors end faces... 6 10.2 Broken connectors... 6 11 Documentation / measurement results... 6 12 Approved test setups... 7 12.1 Test cords... 8 12.2 Length of test cords... 8 13 Alternative measurement: test with OTDR... 9 13.1 Approved test setup... 9 13.2 Test cable (launch and tail cord)... 9 2/9

1 Scope The following acceptance requirements apply to the measurement of permanent links with single and multi-mode optical fibres (SM and MM). The system warranty is only granted for installation sections with known components (Datwyler components). 2 General requirements The installation route includes the permanently installed route including the connector transitions, without patch and connection cables. The acceptance of installation links (permanent links) must be carried out according to the current DIN ISO / IEC 14763-3. The measured values must be submitted in the original format of the measuring device manufacturer. The measurement data must be loaded onto the Datwyler Sharefile system. The regional upload link of the Datwyler Sharefile system is indicated in the registration form. 3 Approved measuring instruments For testing installation routes, power meters and OTDR (Optical Time Domain Reflectometer) have been approved. All measuring instruments that comply with the guidelines of DIN ISO / IEC 14763-3 are approved for the measurements. The same applies to the necessary use of encircled fluxes in the measurement of multimode fibres. 4 Calibration of measuring instruments / measuring adapter The meter must be calibrated regularly by the service of the manufacturer. The last calibration has to be carried out within the past 15 months before the date of the acceptance measurements. It is not allowed to use measuring adapters, which are exceeding the permissible number of mate cycles according to the manufacturer. 5 Increase of the reflection loss The use of an immersion liquid in the connector to increase the reflection attenuation is generally prohibited (for the entire system)! 3/9

6 Permitted attenuation values for installation sections 6.1 Permanent link with spliced single-mode installations A spliced single-mode installation lines consists of: Datwyler FO cable, spliced on both sides on Datwyler 19 "splice boxes. The following parameters apply to the spliced OS2 solution: Attenuation of the fibre: α 0.36 db / km @ 1310 nm α 0.23 db / km @ 1550 nm Maximum value of the splice attenuation: αs 0.10 db Maximum attenuation of the connector: αc1 0.50 db * * The attenuation of plug-in connections in the data centre environment is subject to greater demands, which must be obtained before the acceptance test. 6.2 Permanent link with spliced multimode installations A spliced multi-mode installation lines consists of: Datwyler FO cable, spliced on both sides on Datwyler 19 "splice boxes. The following parameters apply to the spliced OM3 and OM4 solution: Attenuation of the fibre: α 2.7 db/km @ 850 nm α 0.7 db/km @ 1300 nm Maximum value of the splice attenuation: αs 0.10 db Maximum attenuation of the connector: αc 1 0.50 db* * The attenuation of plug-in connections in the data centre environment is subject to greater demands, which must be obtained before the acceptance test. 4/9

6.3 Permanent link with pre-assembled single-mode installations A pre-assembled single mode installation consists of: Datwyler FO cable, pre-assembled on both sides, plugged in Datwyler 19 Breakout boxes. The following parameters apply to the pre-assembled single-mode solution: Attenuation of the fibre: α 0.36 db/km @ 1310 nm α 0.23 db/km @ 1550 nm Maximum attenuation of the connector: αc 1 0.50 db* *The attenuation of plug-in connections in the data centre environment is subject to greater demands, which must be obtained before the acceptance test. 6.4 Permanent link with pre-assembled multi-mode installations A pre-assembled multi-mode installation consists of: Datwyler FO cable, pre-assembled on both sides, plugged in Datwyler 19 Breakout boxes. The following parameters apply to the pre-assembled OM3 and OM4 solution: Attenuation of the fibre: α 2.7 db/km @ 850 nm α 0.7 db/km @ 1300 Maximum attenuation of the connector: αc 1 0.50 db* * The attenuation of plug-in connections in the data centre environment is subject to greater demands, which must be obtained before the acceptance test. 5/9

7 Measuring direction Power Meter: The measurement has to be done in both optical windows (SM: 1310 and 1550nm, MM: 850 and 1300nm). Measuring an installation section with a power meter is sufficient from one direction. OTDR: The measurement has to be done in both optical windows (SM: 1310 and 1550nm, MM: 850 and 1300nm). The measurement of an installation section with OTDR is sufficient from one direction. If negative losses (gainers) occur, measurement from both directions is required. 8 Connectors of the test setup All used connectors of the referencing test setup have to have reference quality. The reference FO-connectors have to be of the same type used in the cabling to be tested. 9 Test cables The FO connectors of the test cables must have reference quality. The test cables used must have fibres with the same core diameter as the fibres of the installation to be measured. When measuring multimode optical fibres, the excitation conditions according to Encircled Flux must be observed. 10 Visual inspection Prior to each measurement, all connectors (measuring object and measuring cable) must be checked in accordance with IEC 61300-3-35. Each time the connection is changed, a new visual inspection is required. 10.1 Cleaning connectors and connectors end faces If contamination is detected during visual inspection, the connector end faces must be cleaned in accordance with DIN IEC / TR 62627-01. The effectiveness of the cleaning must be checked and the cleaning repeated if necessary. 10.2 Broken connectors Broken connectors have to be replaced. 11 Documentation / measurement results The results of the measured installation sections shall be made available in electronic form in the original format of the measuring device manufacturer. The following parameters have to be specified in the documentation to be submitted: - Identification of the measured permanent links - Tester (Type and manufacturer) - Serial number and state of calibration - Nominal wavelength - Details of the measured permanent link (length, fibre type, refractive indices) 6/9

- Documentation of the Datwyler products used - the measurement result - date of test - name of the testing person 12 Approved test setups For testing with a power-meter, only the following test setup is permitted: 1-Cord reference method Step 1 Reference measurement P0: (LS) Power Meter (PM) Optical Power Meter Launch cord 0.00 db Au to Econ Tail cord Step 2 Test measurement: (LS) Power Meter (PM) Optical Power Meter Launch cord Tail cord 0.15 db Au to Econ Check the increase in attenuation by inserting the second reference cable! <0.2 db (SM), <0.1dB (MM) Schritt 3 Prüfmessung P1: (LS) Measured attenuation Power Meter (PM) Optical Power Meter Launch cord Cabling under test (Permanent link) Tail cord 1.74 db Au to Econ 7/9

Using the Launch Cords, a zero balance of the test setup must be made. With a test measurement with connected Launch Cord and Tail Cord the attenuation increase by the Tail Cord is to be examined. An increase in attenuation up to 0.2 db (SM) or 0.1 db (MM) is permitted. For test measurement P1, the Permanent Link to be tested must be inserted between the Launch Cord and the Tail Cord. The test leads must remain connected to the light source (LS) or power meter (PM) during link measurements. The measurement P1 must be recorded in db. In order to avoid incorrect measurements as far as possible, the reference measurement P0 and the test measurement have to be checked in each case after max. 250 measurements. For measured deviations of 0.1 db, the measuring cables must be replaced. Each time the measuring devices are restarted, they must be referenced again. 12.1 Test cords The used test cords must have reference quality. The employed test cords must have fibres with the same core diameter/beam diameter as the fibres of the installation to be measured. The test cords include Launch Cord (as used for multimode with encircled flux method) and Tail Cord. 12.2 Length of test cords Launch Cord: - length: 2 m to 5 m Tail Cord: - length: 2 m to 5 m For Launch Cord and Tail Cord, pre-assembled patch cords have to be used with suitable reference connectors suitable for connection to the cabling under test and / or compatible with the measurement devices. 8/9

13 Alternative measurement: test with OTDR 13.1 Approved test setup For the measurement with OTDR measuring instruments, only the test with launch- and tail cords is permitted. For measuring installations with OTDR measuring instruments, the following test setup must be followed. OTDR Cabling under test (Permanent link) Tail cord Launch cord Event db 1 2 3 4 Cursor A B Result of the measured attenuation Die Settings for the OTDR measuring device can be found in DIN ISO / IEC 14763-3 Annex C. l (m) 13.2 Test cable (launch and tail cord) Launch and tail cords must be longer than the attenuation dead zone of the OTDR, but at least 150m (SM) or 75m (MM). For launch and tail cord, pre-assembled measuring cables are to be used with suitable reference connectors. Spliced cable pigtails are not allowed. 9/9