GROUND FLOOR: 163.7 m² GARAGE: 36.2 m² FIRST FLOOR: 0.0 m² ALFRESCO: 9.3 m² SUB TOTAL: 163.7 m² TOTAL: 212.1 m² 17.6 sq 22.8 sq 4 2 2 Master Bed 3.5 x 3.6 Bedroom 2 3.2 x 3.6 Bedroom 3 Bedroom 4 Living 4.2 x 5.2 SD 2110x1450 Dining 2.8 x 5.2 Sitting 4.1 x 3.6 BED 4 BED 3 WM LDRY BATH BED 2 GARAGE Garage 6.0 x 5.5 Alfresco 4.2 x 2.2 STUDY LINEN WC SW 1200x2170 SITTING ALFRESCO SD 2110x1810 LIVING DINING KITCHEN WIP REF WIR ENS ENTRY 2100x1350 MASTER BED PORCH AW 1800x1810 SW 1800x1810 SW 1027x1450 SW 1027x610 Living Area Total Area Total House Length Total House Width Minimum Lot Width 163.7m² 212.1m² 17.6 sq 22.8 sq 21.00 m 11.30 m 12.5 m
GROUND FLOOR: 163.7 m² GARAGE: 36.2 m² FIRST FLOOR: 0.0 m² ALFRESCO: 9.3 m² SUB TOTAL: 163.7 m² TOTAL: 212.1 m² 17.6 sq 22.8 sq LIGHTING & FITTINGS S.A. GP P DIM POWER OTHER S HWU M/B CEILING LIGHT OUTLET WITH ACRYLIC SHADE. PENDANT LIGHT AS SPEC. CEILING LIGHT WITH SPEC. FITTING. LED (FIXED) DOWNLIGHT. WALL LIGHT AS SPEC.. PARAFLOOD LIGHT WITH SENSOR. 1200 FLURO. SENSOR. INSTALLED AS PER B.C.A. 3.8.5. & EXHAUST FAN (SELF SEALING). TO COMPLY WITH A.S.1668.2. COMBINATION EXHAUST FAN & LIGHT. DIMMER SWITCH TO FITTING AS WIRED. TWO WAY SWITCHING TO FITTING AS WIRED. DOUBLE POWER POINT @ 300MM. SINGLE POWER POINT @ 750MM. DOUBLE POWER POINT @ 1150MM. SGL WEATHER PROOF P.POINT @ 1050MM. DOUBLE WEATHER PROOF P.POINT @ 1050MM. SGL P.POINT @ 600MM ON SEP. CIRCUIT. SGL P.POINT TO CEIL-REMOTE CONT. UNIT SMOKE DETECTOR. GAS BAYONET POINT @ 450mm EXTERNAL METER BOX. HOT WATER UNIT AS SPECIFIED UNLESS NOTED OTHERWISE APPROX. POSITION INSTALLED AS PER B.C.A. 3.7.2. & TO COMPLY WITH A.S.3786. S/B INTERNAL SWITCHBOARD. SOLAR HOT WATER UNIT SECURITY & COMMUNICATIONS 1300H MMP T-BOX ALARM TV POINT HEATING & COOLING TELEPHONE POINT TO MATCH ADJOINING POWER POINT HEIGHT (HEATING ONLY) TO BE TERMINATED AT ACCESS HATCH UNLESS SPECIFIED TV POINT & DOUBLE POWER POINT @ SPECIFIED HEIGHT WITH BLOCKING MULTIMEDIA POINT TO MATCH ADJOINING POWER POINT HEIGHT TERMINATION BOX ALARM KEYPAD D-HUB HTR DISTRIBUTION HUB BOX ALARM ST & SIREN ALARM CONTROL PANEL W/- SINGLE GPO @ 2200MM AFL ALARM SENSOR (TYPICALLY WALL MOUNTED) GAS DUCTED HEATING UNIT (COOLING ONLY) ECU EVAP. COOLER UNIT (WALL MOUNTED ) (CEILING MOUNTED ) AC - HEAD AIR CONDITIONER HEAD AC - CON AIR CONDITIONER CONDENSER CEILING FAN WITHOUT CEILING FAN WITH NOTE: HEATING & COOLING REGISTERS INDICATED ON PLAN ARE SYMBOLIC ONLY. ACTUAL REGISTERS SHAPE & LOCATION PER MANUFACTURES RECOMENDATIONS. DVS SYSTEM @1500MM APPROX. DVP POINT @300MM IMPORTANT: - PROVIDE LIGHT POINT & SINGLE G.P.O. IN ROOF KO. - WHERE INSTALLED, PROVIDE DIRECT POWER OUTLETS TO COOK TOP, RANGEHOOD, UNDER BENCH OVEN. KICKBOARD OUTLET (REFER INTERNALS FOR POSITION)
3 2 2 Master Bed 3.5 x 3.6 Bedroom 2 Bedroom 3 Living 3.6 x 5.2 Dining 2.8 x 5.2 Sitting 3.2 x 3.6 Garage 6.0 x 5.5 SD 2110x1450 SW 1200x1810 Alfresco 3.1 x 2.2 BED 2 WM LDRY BATH SITTING GARAGE BED 3 ALFRESCO SD 2110x1810 LINEN WC LIVING STUDY DINING KITCHEN WIP REF WIR ENS ENTRY 2100x1350 MASTER BED PORCH AW 1800x1810 Living Area 136.2m² 14.7 sq SW 1800x1810 SW 1027x610 Total Area 182.2m² 19.6 sq Total House Length 18.00 m Total House Width 11.30 m Minimum Lot Width 12.5 m
LIGHTING & FITTINGS S.A. GP P DIM POWER OTHER S HWU M/B CEILING LIGHT OUTLET WITH ACRYLIC SHADE. PENDANT LIGHT AS SPEC. CEILING LIGHT WITH SPEC. FITTING. LED (FIXED) DOWNLIGHT. WALL LIGHT AS SPEC.. PARAFLOOD LIGHT WITH SENSOR. 1200 FLURO. SENSOR. INSTALLED AS PER B.C.A. 3.8.5. & EXHAUST FAN (SELF SEALING). TO COMPLY WITH A.S.1668.2. COMBINATION EXHAUST FAN & LIGHT. DIMMER SWITCH TO FITTING AS WIRED. TWO WAY SWITCHING TO FITTING AS WIRED. DOUBLE POWER POINT @ 300MM. SINGLE POWER POINT @ 750MM. DOUBLE POWER POINT @ 1150MM. SGL WEATHER PROOF P.POINT @ 1050MM. DOUBLE WEATHER PROOF P.POINT @ 1050MM. SGL P.POINT @ 600MM ON SEP. CIRCUIT. SGL P.POINT TO CEIL-REMOTE CONT. UNIT SMOKE DETECTOR. GAS BAYONET POINT @ 450mm EXTERNAL METER BOX. HOT WATER UNIT AS SPECIFIED UNLESS NOTED OTHERWISE APPROX. POSITION INSTALLED AS PER B.C.A. 3.7.2. & TO COMPLY WITH A.S.3786. S/B INTERNAL SWITCHBOARD. SOLAR HOT WATER UNIT SECURITY & COMMUNICATIONS 1300H MMP T-BOX ALARM TV POINT HEATING & COOLING TELEPHONE POINT TO MATCH ADJOINING POWER POINT HEIGHT (HEATING ONLY) TO BE TERMINATED AT ACCESS HATCH UNLESS SPECIFIED TV POINT & DOUBLE POWER POINT @ SPECIFIED HEIGHT WITH BLOCKING MULTIMEDIA POINT TO MATCH ADJOINING POWER POINT HEIGHT TERMINATION BOX ALARM KEYPAD D-HUB HTR DISTRIBUTION HUB BOX ALARM ST & SIREN ALARM CONTROL PANEL W/- SINGLE GPO @ 2200MM AFL ALARM SENSOR (TYPICALLY WALL MOUNTED) GAS DUCTED HEATING UNIT (COOLING ONLY) ECU EVAP. COOLER UNIT (WALL MOUNTED ) (CEILING MOUNTED ) AC - HEAD AIR CONDITIONER HEAD AC - CON AIR CONDITIONER CONDENSER CEILING FAN WITHOUT CEILING FAN WITH NOTE: HEATING & COOLING REGISTERS INDICATED ON PLAN ARE SYMBOLIC ONLY. ACTUAL REGISTERS SHAPE & LOCATION PER MANUFACTURES RECOMENDATIONS. DVS SYSTEM @1500MM APPROX. DVP POINT @300MM IMPORTANT: - PROVIDE LIGHT POINT & SINGLE G.P.O. IN ROOF KO. - WHERE INSTALLED, PROVIDE DIRECT POWER OUTLETS TO COOK TOP, RANGEHOOD, UNDER BENCH OVEN. KICKBOARD OUTLET (REFER INTERNALS FOR POSITION)
4 2 2 Master Bed 3.5 x 3.6 Bedroom 2 3.2 x 3.0 Bedroom 3 Bedroom 4 Living 3.6 x 5.2 Dining 2.8 x 5.2 SD 2110x1450 Garage 6.0 x 5.5 Alfresco 3.1 x 2.2 BED 3 WM LDRY BATH BED 2 GARAGE BED 4 ALFRESCO SD 2110x1810 LINEN WC LIVING DINING STUDY KITCHEN WIP REF WIR ENS ENTRY 2100x1350 MASTER BED PORCH AW 1800x1810 SW 1800x1810 SW 1027x610 Living Area 136.2m² 14.7 sq Total Area 182.2m² 19.6 sq Total House Length 18.00 m Total House Width 11.30 m Minimum Lot Width 12.5 m
LIGHTING & FITTINGS S.A. GP P DIM POWER OTHER S HWU M/B CEILING LIGHT OUTLET WITH ACRYLIC SHADE. PENDANT LIGHT AS SPEC. CEILING LIGHT WITH SPEC. FITTING. LED (FIXED) DOWNLIGHT. WALL LIGHT AS SPEC.. PARAFLOOD LIGHT WITH SENSOR. 1200 FLURO. SENSOR. INSTALLED AS PER B.C.A. 3.8.5. & EXHAUST FAN (SELF SEALING). TO COMPLY WITH A.S.1668.2. COMBINATION EXHAUST FAN & LIGHT. DIMMER SWITCH TO FITTING AS WIRED. TWO WAY SWITCHING TO FITTING AS WIRED. DOUBLE POWER POINT @ 300MM. SINGLE POWER POINT @ 750MM. DOUBLE POWER POINT @ 1150MM. SGL WEATHER PROOF P.POINT @ 1050MM. DOUBLE WEATHER PROOF P.POINT @ 1050MM. SGL P.POINT @ 600MM ON SEP. CIRCUIT. SGL P.POINT TO CEIL-REMOTE CONT. UNIT SMOKE DETECTOR. GAS BAYONET POINT @ 450mm EXTERNAL METER BOX. HOT WATER UNIT AS SPECIFIED UNLESS NOTED OTHERWISE APPROX. POSITION INSTALLED AS PER B.C.A. 3.7.2. & TO COMPLY WITH A.S.3786. S/B INTERNAL SWITCHBOARD. SOLAR HOT WATER UNIT SECURITY & COMMUNICATIONS 1300H MMP T-BOX ALARM TV POINT HEATING & COOLING TELEPHONE POINT TO MATCH ADJOINING POWER POINT HEIGHT (HEATING ONLY) TO BE TERMINATED AT ACCESS HATCH UNLESS SPECIFIED TV POINT & DOUBLE POWER POINT @ SPECIFIED HEIGHT WITH BLOCKING MULTIMEDIA POINT TO MATCH ADJOINING POWER POINT HEIGHT TERMINATION BOX ALARM KEYPAD D-HUB HTR DISTRIBUTION HUB BOX ALARM ST & SIREN ALARM CONTROL PANEL W/- SINGLE GPO @ 2200MM AFL ALARM SENSOR (TYPICALLY WALL MOUNTED) GAS DUCTED HEATING UNIT (COOLING ONLY) ECU EVAP. COOLER UNIT (WALL MOUNTED ) (CEILING MOUNTED ) AC - HEAD AIR CONDITIONER HEAD AC - CON AIR CONDITIONER CONDENSER CEILING FAN WITHOUT CEILING FAN WITH NOTE: HEATING & COOLING REGISTERS INDICATED ON PLAN ARE SYMBOLIC ONLY. ACTUAL REGISTERS SHAPE & LOCATION PER MANUFACTURES RECOMENDATIONS. DVS SYSTEM @1500MM APPROX. DVP POINT @300MM IMPORTANT: - PROVIDE LIGHT POINT & SINGLE G.P.O. IN ROOF KO. - WHERE INSTALLED, PROVIDE DIRECT POWER OUTLETS TO COOK TOP, RANGEHOOD, UNDER BENCH OVEN. KICKBOARD OUTLET (REFER INTERNALS FOR POSITION)