Australian Indoor Flue Installation Instructions Vertical Termination Flue Kits for Universal H-Series (Forced-Draft) Heaters

Similar documents
INDOOR INSTALLATION AND VENTING

USER S INFORMATION MANUAL

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

Flue Installation Manual

ASX7-4-IOM-6 J

INSTALLATION INSTRUCTIONS

Flueing Installation Manual

INSTALLATION INSTRUCTIONS

Model: WS18-AU. Model: WS22-AU

Flueing Installation Manual For Rinnai Flamefire Heaters

Model: WS18-AU. Model: WS22-AU

PVK-80 Power Vent - Installation Instructions -

ASX7-5-IOM-3 J

Pellet Stove. Flex Pipe. Appliance Connector

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

GENERAL RULES. Ensure that the installation of your product conforms to all the indications given below. English CHIMNEY STACK

STERLING RSG SERIES INFRARED RADIANT TUBE HEATER

INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS

Specification and Installation Instructions

WARNING FIRE OR EXPLOSION HAZARD.

MASTERTEMP HEATER REPLACEMENT PARTS

Specification and Installation Instructions

Laboratory Fume Cupboards

Bosch 80% AFUE Gas Furnace BGS80 Model

USER S INFORMATION MANUAL

Model No: Little Devil II (inc ss)

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions

For use with log sets

Have you downloaded the groovy show App? Search in the Apple App store or the Google Play Store for Everything Under the Sun

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

EL195UHE SERIES GAS FURNACE WARNING WARNING

EL296UHV SERIES GAS FURNACE WARNING WARNING

Outdoor Tabletop Heater TTH20 Series

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions

WARNING FIRE OR EXPLOSION HAZARD.

MP GS/GD 10 GAS. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

USER S INFORMATION MANUAL

Twin Wall Installation Instructions And Maintenance Guide

INSTALLER'S GUIDE MASONRY CHIMNEY VENT KIT WARNING: BAYVENT800B 18- CH23D2-05

PROPANE GAS HEATER MODEL NO: DEVIL 4000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS GC ISS 4

STERLING RSS SERIES INFRARED RADIANT TUBE HEATER

Wok Cookers Instruction Manual

Superior Unvented (Vent-Free) Gas Log Heaters. Models. For use with log sets

Wall Mounted BBQ Rangehood

INSTALLATION AND SERVICE MANUAL

15B Cast Iron Gas Fired Boilers For Forced Hot Water

Area Heater AH100 Series

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

1.0 GENERAL RULES. Ensure that the installation conforms of all the following instrucons. FLUE LOAD-BEARING CAPACITY CANNA FUMARIA FLUE

Installation & Maintenance Instructions

WAFER Recessed Edgelite Exit LED EXITREC. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

D1/D2 Direct Vent Pilot Replacement Model #: D INSTALLER: Leave these instructions with consumer. CONSUMER: Retain for future reference.

Series RE Infrared Heater

INSTALLATION AND SERVICE MANUAL

OPERATING INSTRUCTIONS AND OWNER S MANUAL

AG Series Electric Heaters

PFS US. Installation and Operation Instructions. Vent-Free Remote Control Gas Fireplace System. Westerly32ZMN Westerly32ZMP

Installation Manual EF5000 AUS & NZ

Mechanical Appliance and Equipment Inspection Checklist

QASAIR Rangehood HNR Under Cupboard Hood

Superior Unvented (Vent-Free) Gas Log Heater. Models. For use with log sets

CAUTION FOR YOUR SAFETY

Zodiac JXi Gas-Fired Pool and Spa Heater Models 200, 370

FOR YOUR SAFETY FOR OUTDOOR USE ONLY PROPANE GAS. Model No. AH2069ODS, AH2063ODS

Manual. Owners & Installation GOSFORD FREESTANDING WOOD FIRE Model: F300B PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

Installation instructions for the T 9820 Gas Dryer

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

OPERATING INSTRUCTIONS AND OWNER S MANUAL

FREE. Functions and Features:

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

Operation & Installation Manual

USER S INFORMATION MANUAL

Models BGE18NV BGE18PV BGE2436NV BGE2436PV. For use with log sets

Wall Mounted BBQ GRHM & GRHL

Public Input No. 16-NFPA [ Section No ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

GB162 Concentric Horizontal Vent Kit

ML180UH SERIES GAS FURNACE WARNING WARNING

CINCINNATI, OH USA

OPERATING INSTRUCTIONS AND OWNER S MANUAL

AUSTRALIAN GAS ASSOCIATION CERTIFIED

INSTALLATION AND OPERATING INSTRUCTIONS

Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES

OPERATING INSTRUCTIONS AND OWNER S MANUAL

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

WSK300 Multifunction Wall Control

PROPANE CONSTRUCTION HEATER

INSTALLER: LEAVE THIS MANUAL WTIH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

24 VAC SYSTEM CONTROL KIT

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

Installer s Guide IMPORTANT INFORMATION Read This Document First On completion, sign and leave with owner

PVC Venting Addendum. RIVA Plus WALL HUNG GAS BOILER FOR CENTRAL HEATING SUPPLY

Operating and Installation Instructions

XANDER INSERT WOOD BURNER

PG33 Gas Inbuilt. Manual

INSTALLATION AND OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS AND OWNER S MANUAL

vent With family and friends to take care of, it goes without saying you need the help of reliable kitchen appliances.

Installation Instructions

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

Transcription:

Australian Indoor Flue Installation Instructions Vertical Termination Flue Kits for Universal H-Series (Forced-Draft) Heaters IMPORTANT NOTES:. This kit is intended to be used only with Australian Hayward Universal H-Series (Forced-Draft) gas heater models manufactured after November, 203. These heaters may be identifi ed by inspection of the heater rating plate which is located on the inside base of the heater and can be seen with the front door removed. The model number should match one of those listed in Table, and the manufacturing date must be after November 203. The manufacturing date is part of the Serial Number and using Table 2 shows how to extract that date. 2. This instruction sheet is intended only for the heater service parts kits listed in Table. TABLE Part Number Description For Use With Heater Models Flue Pipe Limitations Flue Pipe Material Flue Termination Requirement UHXNEGVT50AU UHXNEGVT250AU UHXNEGVT400AU Indoor Flue Adapter Kit, Vertical Fluing Applications Only H50FDAU H250FDAU 2 metres max vertical height, 6 metres max horizontal length (horizontal length cannot exceed /2 of vertical height), 3 elbows allowed maximum. Single Wall Galvanised Non-Sealed Flue Pipe *Twin wall Flue Pipe* Vertical Only, Termination Above Roof of House/Building *Twin wall fl ue pipe can only be used with the use of a single wall to twin wall fl ue pipe adaptor that shall comply with the requirements of AS 4567* TABLE 2 Serial Number Format Year (y) Month (mm) 23yymmxxxxx00 3 = 203 4 = 204 5 = 205 6 = 206 7 = 207 8 = 208 0 = Jan 02 = Feb 03 = Mar 04 = Apr 05 = May 06 = Jun Note: xxxxx indicates the serial number. 07 = Jul 08 = Aug 09 = Sep 0 = Oct = Nov 2 = Dec 3. This kit enables outdoor model heaters to be confi gured for indoor installation. All work shall be conducted by a qualifi ed Gas Plumber/Fitter specifi cally trained and experienced in the installation of this type of heating equipment. The fl ue pipe termination is required to be vertically terminated above the house roof or building and the included approved fl ue cowling shall be used. The heater and Indoor Flue Kit must be installed as per the included instructions, and in accordance with AS/NZS 560. (current edition), as well as all local, state and federal laws and regulations. Where these instructions are contrary to the law or regulations of an appropriate government body those laws or regulations should take precedence subject to there being no compromise to safety. 4. These fl ue kits are only suitable for installation on heaters up to a maximum altitude of 60 metres and can be used on natural gas or propane models. WARNING Failure to comply with the installation instructions in this instruction sheet may result in equipment damage, fi re, asphyxiation, or carbon monoxide poisoning. Exposure to products of incomplete combustion (carbon monoxide) can cause cancer, birth defects, or other reproductive harm. Page of 5

CONTENTS OF THE KIT Qty Description Flue pipe adapter for vertical termination galvanised vent pipe Flue cover plate with hole for fl ue pipe 2 #0 Sheet metal screws Blower baffle plate (UHXNEGVT250AU & UHXNEGVT400AU only) Flue pressure switch Flue pressure switch tubing Flue pressure switch jumper wire pair Flue pressure switch tubing tee (UHXNEGVT50AU & UHXNEGVT250AU only) Label Indoor Installation Only Roladuct flue cowling - AGA Certifi ed NOTES ON INDOOR INSTALLATIONS Clearances The heater must be installed such that the installation and service clearances from combustible materials shown in Table 3 are maintained. This heater may be installed on combustible fl oors. Do not install heater in a cupboard or in a roof cavity or roof space. If the heater is being installed inside a garage it shall be installed with the base of the heater raised at least 450 mm above the fl oor. DO NOT install the heater in a location where it may ignite fl ammable vapours or materials or where chemicals may combine with combustible air and cause corrosion or malfunction of the heater. DO NOT store fl ammable or corrosive liquids or materials in the same room as the heater. The ventilation and combustion air shall be supplied via two permanently open vents connected directly, or via ducts that have the same cross-sectional area as the vents, to outside air. The openings shall be located to ensure the distance between the top of the upper opening and the ceiling of the room or enclosure, and the distance between the bottom of the lower opening and the fl oor of the room or enclosure, do not exceed 5% of the height of the room or enclosure. Each of the two permanent openings connected to directly outside shall be provided with a minimum free ventilation area as shown in Table 4. Table 4 is a guide only with the vent areas calculated for a single gas heater installed only and no other appliances requiring ventilation air. For more detailed methods of providing air for combustion and ventilation, refer to the current edition of AS/NZS 560. Gas Installations - Part : General Installations. Model TABLE 4 Gas appliance in a room or enclosure, other than a plant room Gas appliance in a plant room H50FDAU 47,400 mm² 23,700 mm² H250FDAU 79,200 mm² 39,600 mm² 26, 600 mm² 63,300 mm² Note: The minimum vertical dimension of any free ventilation opening shall be 6mm. Heater Panel TABLE 3 Top Front Back Water Connection Side Side Opposite Water Connection Required Clearance 000 mm Unobstructed 50 mm 300 mm 50 mm Hayward Pool Products (Australia) Pty Ltd, DOES NOT recommend installing spa blowers in the same room as a gas heater. This has the potential to be dangerous or fatal to spa or pool users. Air Supply Indoor installations and outdoor shelters (confi ned spaces) must be provided with adequate combustion and ventilation air to assure proper heater operation and shall be in accordance with AS/NZS 560. current edition. Failure to provide adequate ventilation voids all warranties and may be a danger to persons or property. Page 2 of 5

Flue Installation All aspects of fl ue installation shall be in accordance with AS/NZS 560. current edition and local / state regulations. All installation work must be carried out by an authorised and qualifi ed person. - The fl ue pipe diameter shall not be smaller than the size of the fl ue pipe adaptor on the heater (see Table 5). - The maximum total fl ue length incorporating a maximum of up to 3 x 90 elbows is 8 metres. - The maximum fl ue height cannot exceed 2 metres and any lateral (horizontal) run in a fl ue shall be as short as possible and not exceed /2 of the total fl ue height, and shall rise not less than 20 mm per metre of lateral run. - The minimum vertical length fl ue before an elbow can be used is 50 mm. For more detailed information regarding fl ue termination, refer to the current edition of AS/NZS 560. Gas Installations - Part : General Installations..5 metres minimum clearance to adjacent wall or building FIGURE AGA approved cowl 600mm minimum It is recommended that fl ues over 6 metres long may require to be insulated to reduce condensation related problems in cold environments, or to install an approved condensate drain at low points where condensate may collect. Flue joints shall seal adequately and if necessary a sealing agent shall be used. TABLE 5 Indoor Flue Kit Part Number Heater Model Flue Pipe Diameter UHXNEGVT50AU H50FDAU 50 mm UHXNEGVT250AU H250FDAU (6 inch) UHXNEGVT400AU 200 mm (8 inch) The fl ue shall be supported independently of the gas heater and shall be securely fi xed and adequately supported by brackets fastened to the building structure at suitable points, to ensure the stability of the fl ue unless the fl ue is designed to be structurally independent of the building. The minimum clearance between a single wall fl ue and a combustible surface and a non-combustible surface shall be as those stated in AS/NZS 560. current edition. All roof and wall penetrations shall be made using approved products and in accordance with AS/NZS 560. current edition and local regulations. Flue Termination The termination point of the fl ue shall be vertical and above the roof of the house or building. It shall be located in relation to any associated building and to neighbouring structures so that wind from any direction is not likely to create a downdraught in the fl ue and shall be: - At least.5 metres from any opening into a building. - At least 200 mm from another fl ue terminal. - At least 600 mm from the end of the fl ue to the nearest part of the roof (Refer Figure ). L GND Fenwal 35-6 Ignition Control Module S Spark IND PSW TH R V V2 Flame Sensor FIGURE 2 YLW Spark Igniter YLW BRWN RED TDR Blower Pressure H50 & H250FDAU NOTE: H50FDAU & H250FDAU Flue Pressure Normally Closed switch opens on pressure rise at set point. Normally Open switch closes on pressure drop at set point. Page 3 of 5

INSTALLATION PROCEDURE. If connected, turn pump, main gas valve, and heater power off. 2. Locate the heater as close as practical to the fl ue pipe exit. 3. Remove the button Phillips-head screws and remove the fl ue cover panel on top of the heater and discard. Save the button-head screws as they will be re-used later. 4. Remove the screws that fasten the heat barrier to the heater. Remove the heat barrier and discard. See Figure 3. 5. Remove the screws that fasten the rain guard to the heater. Remove the rain guard and discard. See Figure 3. 6. Install the fl ue pipe adapter plate included in this kit into the heater using the #0 screws included with this kit. Ensure the white gaskets are in place under the vent pipe adapter plate before installing. See Figure 4. 7. Install the new fl ue cover included with this kit over the fl ue pipe adapter and secure with the button-head screws from step 3 above. See Figure 5. 8. Remove heater front access door. 9. The fl ue pressure switch included with this kit is for this model heater up to an altitude of 60 metres only. Install the fl ue pressure switch inside the heater using two #0 screws as shown in Figure 6. 0. If installing the kit on models H250FDAU or, you must replace the existing blower baffl e plate with the new one included in the kit. a) Remove the 5 #0 hex head screws that fasten the plate to the blower and remove the blower baffl e plate and discard. Save the 5 screws as they will be needed to install the new plate. b) Install the new blower baffl e plate included in the kit using the 5 screws. It may be helpful to drive the screws in and out of the plate outside of the heater fi rst to thread the holes before installing it in the heater. See Figure 7.. Attach the pressure switch tubing to the fl ue pressure switch. On models H50FDAU & H250FDAU use the 6 mm plastic Tee provided in the kit to join into the grey air pressure tube that connects the blower air pressure switch to the pressure tap on the blower outlet. For the model attach the pressure switch tubing to the fl ue pressure switch and to the pressure tap point located on the blower baffl e plate just below the array of holes. See Figure 7 for blower tap location on models H50FDAU & H250FDAU. 2. Connect the pair of jumper wires included with this kit onto the terminals on the fl ue pressure switch. Unplug the bottom blue wire from the blower pressure and connect the jumper wires from the fl ue pressure switch to the connector on the blue wire and the terminal on the blower pressure switch so that now both pressure switches are connected in series. See excerpt from heater wiring schematic in Figure 2 located on page 3. 3. Re-install heater front door. 4. Take the label Indoor Installation Only that is in this kit and replace or stick on top of the label on the heater that says Outdoor Installation Only 5. Connect fl ue piping system to heater fl ue adapter. 6. If connected, turn pump, main gas valve, and heater power back on. 7. Activate heater and check for proper function. Page 4 of 5

FIGURE 3 FIGURE 4 Flue Adapter Heat Barrier Rain Guard FIGURE 6 FIGURE 5 Flue Cover FIGURE 7 Blower Air Inlet Plate Blower Pressure Tap Tubing Page 5 of 5