Indirect Expansion. USER MANUAL FOR OPERATORS AND PLUMBERS HEAT INTERFACE UNITS

Similar documents
Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

Heat Interface Units for decentralised water heating in district heating systems

Herz York Direct Heat Interface Unit

TS RD 7761 RD, 7761 RD

Say heating. Say Herz. HERZ-Supply Engineering

SEALED THERMAL STORE

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

Akva Vita TDP District heating flat station for direct heating and domestic hot water systems

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

Akva Lux VX District heating substation for indirect heating and domestic hot water systems

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems

HW 22 District heating substation for indirect heating and domestic hot water systems

Akva Lux TDP-F District heating flat station for direct heating and domestic hot water systems

Thermostatic mixing valves with interchangeable cartridges

Thermostatic mixing valves with replaceable cartridge for centralized systems

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

HERZ Differential Pressure Control Valve 4002

Unvented Electric Water Heater 10/15 litre Undersink

Thermostatic Concealed Shower Valve

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

CUBEflow Thermal Store Tank

Installation and operating instructions. DK energy storage and DK energy buffer

Installation and Operation Instructions Domestic hot water module FriwaMini with circulation - DN 15

Inta City Concealed Shower Mixing Valve CT80010CP

Installation Guide. Termix Distribution unit. 1.0 Table of Contents. 1.0 Table of Contents

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

ADVANCE ECB ELECTRIC COMBINATION BOILER

CENTRA-COIL QUALITY HOT WATER SERVICE

ELECTRIC BOILERS FOR CENTRAL HEATING

Manual. Above-counter dispenser for hot drinks OTHG /12

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

Operating instructions

Thermostatic valve bodies

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

THERMflow Thermal Store Cylinders

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Installation & Technical Guide. Domestic & Commercial.

Operating instructions

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Friwa Compact. Operating instructions EN

Installation, Operation and Maintenance Manual

STORAGE WATER HEATERS

HERZ Regulating valve 4002

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield

Intatherm Safe Touch Basin Tap IT1008CP

Enzo Concealed Shower Mixing Valve

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

Installation, Operation and Maintenance Instructions for Electric Storage Calorifier

Flow Factor ~

Operating instructions

WL Instantaneous water heater

OPERATING AND INSTALLATION MANUAL

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

Solar water heating system

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS

ADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS

Thermostatic valves with radiator connection systems

MEGAFLO HE Iss 1

Pump assembly Instruction manual

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

Akva Vita Instantaneous water heater

Instructions for installation and use Akva Lux II VX substations 1. Contents

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.

T. +44 (0) E.

Installation, Operating and Maintenance Guide

Electronically controlled instantaneous water heater. DEX: C models. Instructions for the user

COMMERCIAL ELECTRIC WATER HEATER OWNER S MANUAL OPERATION AND MAINTENANCE INSTRUCTIONS

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER

USER MANUAL INSTALLATION INSTRUCTIONS WARRANTY REGISTER

Valves, controls + systems. Local and district heating technology. Innovation + Quality. Product range. for improved.

Installation manual Operating instructions

Three-way reversing valve

ModuSat TP. Energy. Heat Interface Units

Eliminator TotalGuard Installation Manual

Valves, controls + systems. Innovation + Quality. Stations for solar energy and solid fuel boilers Product range

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

OPERATING AND INSTALLATION MANUAL

CAH SERIES INSTALLATION & MAINTENANCE MODELS CAH CAH

heat interface units A BOILER WITHOUT A FLAME

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

Thermostatic valve bodies

Wilbur Curtis Company, Inc. Service Manual WB-10 Water Boiler

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Transcription:

Indirect Expansion FOR OPERATORS AND PLUMBERS HEAT INTERFACE UNITS 1 4008 49 USER MANUAL HERZ Valves UK Progress House, Moorfield Point Moorfield Road, Slyfield Industrial Estate Guildford, Surrey GU1 1RU Tel: 01483 502211, Fax: 01483 502025 E-Mail: sales@herzvalves.com HERZ Armaturen GmbH Richard-Strauss-Str. 22, A - 1230 Vienna Tel.: +43 (0)1 616 26 31-0, Fax: +43 (0)1 616 26 31-27 E-Mail: office@herz.eu www.herz.eu

Introduction The HERZ Substation Indirect Expansion is a wall mounted unit for providing hot water. In contrast to a hot water boiler which heats and then stores the water before it is being used, the substation operates only when hot water is required. Due to inner system division incorporating two heat exchangers, domestic hot water and heating is supplied completely separately. Furthermore with the integrated compact distributor, up to nine heating circuits can be connected with the Heat Interface Unit. The HERZ Substation Indirect Expansion ensures constant temperature and flow of hot water, no matter how much or how often water is drawn from a tap. Advantages of the HERZ Substation: - enables individual room heating and supply of domestic hot water - System separation with two heat exchangers - the continuous-flow heating enables a permanent supply when domestic hot water is required - the HERZ substation can be customized to the individual requirements of the consumer - up to nine heating circuits connectable with compact distributor - minimal space required - needs no domestic hot water boiler - the constant water temperature in the heat exchanger reduces the danger of legionella- and lime formation - low return temperature - minimal heat losses in the system - easy to install - optimal heating comfort 1. Function In the stand-by mode the heating water flows from the primary circuit (district heating main) via a bypass which is kept at operating temperature with a return temperature limiter. The Heat Interface Unit Indirect Expansion has a priority circuit in the PT - controller, which ensures that the whole power is used for providing domestic water, when needed. The radiator heating is then turned off,if a hot tap is operated. If hot water is drawn from a tap by a domestic user connected to the system, the control valve for the cold and heating water is opened by the difference in pressure. Cold water flows through the heat exchanger, is heated up and promptly available as hot water at the domestic hot water tap. The temperature of the domestic hot water is controlled by a thermostat. Using an immersion sensor, this thermostat controls the temperature of the hot water that exits the heat exchanger, which in turn regulates the pressure and temperature controller. If there is no demand from the hot water taps, the primary heating water flows in to the second heat exchanger and is used as hot water for the heating circuit 4. Equipment Important components of the HERZ Substation Indirect Expansion system, which flows then directly through the forerun into the compact distributor with built in shut-off valves. The temperature is then regulated by thermostats in the radiotors. An integrated circulation pump is installed in the heating flow, to ensure constant circulation in the heating circuit and an expansion vessel holds the pressure constant in the system. A zone valve with an actuating drive is installed into the return of the substation to shut off the heating circuit, when the substation is used in summer. As a safety measure (in accordance with EN 1111), a thermostatic mixing valve is fitted for the domestic hot water system so as to prevent scalding at the tap. Due to this safety fitting the hot water can be below the desired temperature if only a little quantity of water is used or the tap is turned on briefly. A Pressure Relief safety valve is addionally installed into the return of the compact distributor. It closes automatically if the pressure in the system is to high and regulates it down. A strainer with a fine-mesh screen of 0.75 mm is fitted in the heating flow to catch impurities. 2. General notes on installation 1. For installation please refer to the drawings and manual included in the packaging. 2. When choosing where to mount the HERZ Substation, the weight of the substation itself as well as the weight of the water must be taken into account. 3. If the HERZ Substation is built in or installed in confined spaces, intermediate ceilings, etc., the front of the unit must be freely accessible for repair and maintenance purposes. 4. Before mounting the HERZ Substation, check that the wall is vertical. 5. Depending on the type of wall where the unit is mounted, the appropriate wall anchors and screws must be used. 3. Safety notes 1. The substation must be installed and connected by professional plumbing and heating engineers only. 2. Only use original HERZ spare parts to replace faulty parts or heating components. 3. Check all connections for leakages prior to starting up the heating system. 4. All screws must be checked and tightened after the substation has been installed. 5. The user must not make any technical changes to the heating system. Otherwise HERZ will not assume liability for any resulting damage. 6. The HERZ Substation must only be installed in rooms and locations that meet the legal requirements. PT-controller As the central unit in the HERZ substation the HERZ PT-controller ensures the provision of hot water and constant temperatures. Reacting to the difference in pressure the valve opens or shuts the heating water and the cold water inlet to the exchanger. Simultaneously, the temperature of the hot water is controlled by a thermostat. Mixing valve for drinking water The mixing valve for drinking water regulates the temperature of the domestic hot water up to a maximum of 52 C. Thereby scalding at the open tap is avoided. The HERZ Substation DELUXE Indirect is thus usable for all public applications, like daycare centres, schools, hospitals. Cold and domestic water is mixed by the help of a thermostatic element, which can be adjusted to the required temperature. The mixing valve closes immediately if the cold water supply is interrupted. Thermostatic mixing valves according to EN 1111 are mandatory in certain applications for temperature protection at terminal points. Return Temperature Limiter Used for controlling the return temperature in the HERZ substation between 25-60 C. Limitation and locking of the set value range can be achieved by means of stop pins, which need to be ordered separately. -2-

Actuating drive Electro thermal actuating drive for heating regulation valves, installation in combination with an electrical room thermostat for twopoint- regulation in heating and cooling systems. Zone valve 7760 RD Thermostatic valve with reverse function, straight model, valve body made of brass, nickel-plated, steel spindle made of stainless steel, seals made of EPDM. Model with male thread connection and inside cone for compression adapters. Thread for Thermostatic head M 28 x 1,5. Pressure Relief safety valve Housing made of forged brass, EPDM Diaphragm, cap seals and plastic. Temperature range is from 0 C to +110 C. Thermostatic bypass valve HERZ thermostatic valve, nickel coated brass, with screw cap. In the HERZ Substation Indirect ExpansionVersion substation this valve is installed in a bypass. Premounting unit Supplied as mounting plate with holes, completed by ball valves for heating, cold- and hot water, connection possible from the wall, or from the bottom. The connection to the substation is done by inserting and screwing connections at the pipe side, fixing parts included. The HERZ premounting unit needs to be ordered separately. 5. Operating data For providing hot water: With fitted flow rate limiter: 15 [l/min] Inlet pressure: 2,8 [bar] Amount of water drawn in l/min 15 Temperature of cold water in C 10 Pressure drop in kpa 25 Distribution of the connections: 1. Flow district heating plant 2. Return district heating plant 3. Flow cold water 4. Return cold water 5. Supply mains water 6. Heating flow 7. Heating return 1 2 3 4 5 6 7 Flow rate in l/h 880 Hot water temperature in C 50 Heating capacity of the heat exchanger in kw 6. Dimensions of the Substation 10 Dimensions of the HERZ Substation Dimension of the connections, inlet/outlet Supply flow district heating plant Return flow district heating plant Cold water inlet Hot water outlet Heating flow 7. Construction Through its reduced dimensions and its compact design the HERZ- Substation can be flush mounted, so the HERZ substation can be installed either in the staircase or in the apartment (e.g.: instead of a classic hot water tank). Therefore the HERZ- Substation is delivered as a flush mounted version, with all of her components on a metal steel plate and screwed in the inwall unit. This has the advantage that, when there are construction works only the body needs to mounted and when the construction works are done, the HERZ- DELUXE Substation only needs to be inserted and connected. Either the heating circuit or the domestic hot water can be isolated by closing the ball valves, so in a case of malfunction the problems can be solved independently from each other. A floor distributor set is integrated in the substation, which can also be installed separately after construction works are done. All elements of the HERZ- Substation are mounted with detachable connections so they can be changed or maintained. Heating return Substation Dimensions (W x H x D) mm Substation complete 646 x 1740 x 150-3-

8. Function schematic Substation Indirect Expansion Reacting to the difference in pressure the valve opens or shuts the heating water and the cold water inlet to the exchanger, and simultaneously the temperature of the hot water is controlled by a thermostat. Due to the built in compact distributor (16), up to nine heating circuits can be connected. Furthermore the integrated circulating pump (12) ensures a constant circulation of the heating water. The mixing valve for the domestic hot water system (8) is another essential component of the HERZ Substation. It is fitted with a thermostat and mixes cold and hot water to the desired temperature in order to avoid scalding at the tap. Addionally a pressure relief safety valve is installed. An expansion vessel (17), in the substation, holds the pressure in the system on a constant level. Hot water is drawn via the HERZ ball valves (6 and 7). 9. Connecting to the district heating main The Substation is connected parallel to the district heating main. If possible, the substation should be installed before the first end user. 10. Operating conditions Besides the national rules and regulations, the industrial standards as well as the connection conditions of the local water supplier need to be met and, furthermore, installation and operating instructions need to be followed. The room where the substation will be installed should be frostfree and the place of installation has to be chosen in such a way that the substation is easily accessible for maintenance and repair work. The incoming water temperature should range between a minimum of 60 C and a maximum of 80 C. A primary static pressure of 10 bar and a primary differential pressure of 0.5 bar are fine. Furthermore, in case of system failure, all connecting pipes must be able to withstand a maximum temperature of 95 C. 1 HERZ- PT - controller 2 HERZ- thermostatic bypass valve 3 HERZ- return temperature limiter 4 HERZ- actuating drive 5 HERZ- strainer 6 HERZ- ball valve for drinking water 7 HERZ- ball valve 8 HERZ- mixing valve for drinking water 9 HERZ- thermostatic head with hydrosensor 10 Heat exchanger 11 Heat exchanger 12 Circulating pump 13 HERZ- pressure relief safety valve 14 HERZ- differential pressure overflow valve 15 Draining cock 16 Compact distributor 17 Expansion vessel System description: The control system consists of two heat exchangers (10 and 11) with a priority circuit in the forerun. When domestic water is tapped, the PT-controller closes so that the whole power is used for the domestic water processing. Meanwhile the heating circuit is closed. The HERZ pressure and temperature controller (1) is built in as the central unit in the HERZ Substation Indirect Expansion, which ensures the provision of hot water and constant temperatures. 11. Starting-up The HERZ Substation is easy to operate and user-friendly. All you have to do is open up the ball valves in the following order so as to avoid water hammer: 1. Open heating water inlet slowly (red ball valve). 2. Open cold water inlet slowly (green ball valve). 3. Open heating water return slowly (red ball valve). 4. Open hot and cold water outlet slowly (green ball valve). 12. Temperature setting The HERZ Substation DELUXE Indirect is set to a default temperature of max. 55 C. The settings of the thermostat cannot be changed to ensure the optimal tap water temperature at all times. 13. Initial start-up In accordance with the Austrian ÖNORM H5195-1 standard, before initially starting up the HERZ Substation, make sure to use only clean pipe materials that comply with standards (i.e., all pipe work must be free from forging scale, rust, burrs and impurities). The same holds true for fittings and units (boilers, radiators, convectors, expansion vessels, etc.). The Austrian ÖNORM H5195 standard further provides for clean and professional workmanship (without welding beads, sealing or solder residues, burrs, bore chips and others) and cleaning of all components prior to their installation. Strainers should be fitted because deposits in the pipes can damage the controller and impurities can enter the drinking water system. To prevent corrosion in the heating system, the Austrian ÖNORM H5195-1 standard requires the following measures: When installing and operating the heating system, make sure that as little air as possible enters the closed heating circuit. Before initially starting up the heating plant, flush it through twice (so that the entire water contained in the system is replaced twice). Then fill with clear, filtered water (filtered with a 25 μm pore size filter) of the required quality standard. When first -4-

starting up the heating system, it must be kept running at normal operating conditions for 24 hours so that the heating water is evenly mixed with the inhibitor. Old heating systems must be treated with a chemical cleanser and then flushed with water before refilling them. Do not partially or entirely drain the heating system, leaving it without anti-corrosion treatment for a prolonged period of time; otherwise the system will be more susceptible to corrosion. To avoid damage by frost at low temperatures, the heating system must be protected in compliance with the Austrian ÖNORM H5195-2 standard as follows: In general, anti-freeze and water can be mixed to any percentage. However, heating systems with circulation pumps should be filled two thirds with water, then the anti-freeze added and only then should the system be topped up with water. The anti-freeze will be thoroughly mixed with the water once the system is put into operation and the fluids start circulating. Gravity-fed heating systems, however, must be filled with a combined anti-freeze and thermal fluid. If anti-freeze needs to be put into a heating system that has so far been unprotected, the following must be observed: 1. Ensure that the anti-freeze is suitable for the sealing materials. 2. The system should be power flushed. 3. After having added the anti-freeze, the system must be double checked for leaks. In order to be able to do this, HERZ recommends using the HERZ multifunction ball valves on the inlet and return pipes (order no.: 1 2414 xx and order no.: 1 2415 xx, respectively). 14. Shutting down, emptying Shutting down the HERZ Substation for a prolonged period of time or dismantling it for whatever reason is done by shutting all ball valves. In rooms exposed to temperatures below freezing the HERZ Substation must be drained down prior to the start of the cold season if the substation is to be shut down for several days. To drain the substation, place a vessel with a capacity of 4 to 8 litres underneath the substation and drain the hot water from the ball valves till the HERZ- Substation is completely empty. If temperatures are liable to drop below freezing point, be aware that not only the water in the HERZ Substation and the hot water pipes may freeze but also the water in the cold water inlet pipes leading to the fittings and to the unit itself. Therefore it is best to drain all water pipes and pipe fittings up to the frost-proof part of the domestic heating system. 15. Servicing and maintenance Owing to its outstanding design, the HERZ Substation requires comparably little maintenance work. However, in hard water areas lime-scale can build up in the system. Depending on the hardness of the water, your system should be de-scaled by a professional every one to two years. In case scale in the system has damaged the valves, these should be replaced immediately to ensure smooth operation of your heating system. If the strainers provided have been fitted into the mixing valves, they have to be inspected by a plumber at regular intervals in order to prevent the hot water temperature from rising. Do not clean the unit with scouring or harsh cleaning products. Wipe it down with a damp cloth which has been rinsed in water with a few drops of mild detergent. Heat exchanger Parameters Temperature Recommended limits for the tap water quality on the secondary side Depends on the composition of the water, but under 60 C, to reduce the risk of stress corrosion of the stainless steel and pitting corrosion in the copper through the hot water. PH-value 7-9 Alkalinity Conductivity 60 mg/l < [HCO 3 -] < 300 mg/l < 500 μs/cm Hardness [Ca 2 +,Mg 2 +]/[HCO 3 -] > 0,5 Chloride 1000 mg/l at 25 C 300 mg/l at 50 C 100 mg/l at 80 C 0 mg/l at T > 100 C Sulphate [SO42-] < 100 mg/l and [HOC3-]/[SO42-] > 1 Nitrate Free chlorine < 0,5 mg/l [NO3-] < 100 mg/l Note: The given reference values of the heat exchanger producer are considered with regard to the required water quality. 16. Spare parts Article PT- controller Thermostat Return temperature limiter Thermostatic bypass valve Premounting unit Mixing valve for drinking water Actuating drive Thermostatic valve with return function -5-

Pressure Relief safety valve Heat exchanger CB 20/40 Heat exchanger CBH 18-16 17. Accessory Premounting unit HERZ- Inwall unit Inwall unit made of zinc coated steel, with mounting frame. - Front frame and door white powder coated (RAL 9003), door with lock - W x H x D: 646 x 1740 x 200 mm - inklusive Befestigungsmaterial - ist separat zu bestellen Electronic Room Temperature Controller 1 change-over contact Set value range 10-30 C Switching difference ± 0.2 K fixed Room Temperature Controller For individual time and temperature programmable adjustment. Digital timer with program on a weekly and yearly basis, automatic switching between summer and winter time. Set value range 8-38 C Switching difference as 2-point controller 0.4-8 K Metering precision 0.3 K at a temperature of 20 C 18. Troubleshooting, malfunctioning Problem: The hot water temperature is too high Solution: The HERZ PT controller must be checked and, if necessary, replaced by a qualified and approved plumbing and heating engineer. Problem: The hot water temperature is too low Lösung: The heat exchanger must be checked and, if necessary, replaced by a qualified and approved plumbing and heating engineer. Check with your district heating provider whether there is a failure in their system. Check that the red ball valves are turned on. The thermostat controller must be checked and, if necessary, replaced by a qualified and approved plumbing and heating engineer. The whole system must be checked by a qualified and approved plumbing and heating engineer for scale buildup. 19. Recycling and disposal The substation as well as the packaging are mainly made of recyclable raw material. Substation Substation as well as the accessory don t belong to the household waste. It needs to be taken care of that the substation and available spare parts are disposed properly. Packaging The disposal of the packaging is left for the craftman s establishment, who installed the substation. Please note: all diagrams are indicative in nature and do not claim to be complete. All specifications and statements within this brochure are according to information available at the time of printing and meant for informational purpose only. Herz Armaturen reserves the right to modify and change products as well as its technical specifications and/or it functioning according to technological progress and requirements. It is understood that all images of Herz products are symbolic representations and therefore may visually differ from the actual product. Colours may differ due to printing technology used. In case of any further questions don t hesitate to contact your closest HERZ Branch-office. BA_WÜS-49_0612_1-6-