UL TEST REPORT AND PROCEDURE

Similar documents
UL TEST REPORT AND PROCEDURE

EU Declaration of Conformity

UL TEST REPORT AND PROCEDURE

File E Project 05ME Issued: November 1, 2005 Revised: February 27, 2009 REPORT

Certificate of Compliance

Certificate of Compliance

File E Project 97SC January 21, 1998 REPORT

REVISION HISTORY Rev Description Author. Approved by Date A Initial release per ECO Dean King Dean King November 16, 2012

UL TEST REPORT AND PROCEDURE

EU Declaration of Conformity

Certificate of Compliance

Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Certificate of Compliance

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

Certificate of Compliance

Field Certification Certificate of Compliance

Oberon s NEC Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

Installation Instructions

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

J-PRO TM Cable Support System

Table of Contents. Important Safety Instructions. WARNING: If the instructions contained in this manual are not followed

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

standards: standards:

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

HDCVI PTZ Network Camera

PRM-100 INSTALLATION MANUAL OUTDOOR PARAPET ROOF MOUNT WITH ELL CONDUIT BOX MANUAL NUMBER

UL Electrical Equipment for Measurement, Control, and Laboratory Use; Part 1: General Requirements, Second Edition

Installation Instructions

4 MP HDCVI PTZ In-ceiling Camera

Test Report. Appliance EMF Testing

Burner control unit BCU 370

Certification Supplement Manual

SECTION C. Section Cable Trays for Electrical Systems: Additional identification requirements for cable tray systems.

Installation Instructions

Installation Instructions

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

Installation Instructions

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

TECHNICAL BULLETIN VG4 Series Modular AutoDome

Installation Instructions

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Certificate of Compliance

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

Certificate of Compliance

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

LC3000 Level Controller Installation and Maintenance Instructions

Products :: Circuit Protection :: Thermal Circuit Breakers

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

INSTRUCTION & SERVICE MANUAL

Certification Supplement Manual

ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER

[Project Location] SECTION FUSION STAINLESS STEEL DOME HOUSING MOOG VIDEOLARM A&E SPECIFICATION SSDP SERIES

Certificate of Compliance

SECTION ISOLATED POWER SYSTEMS

Certificate of Compliance

Electrical Safety Requirements

ORDINANCE NO

INSTALLATION INSTRUCTIONS FOR SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP

Certificate of Compliance

File E Project 08ME October 7, 2008 REPORT. UNLISTED COMPONENT - Attachment Plugs, Fuseless. For Use Only In

FLASHLIGHT ANSI STANDARDS

Oberon s National Electric Code (NEC)Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

HDCVI PTZ Camera. 6C Series. Quick Start Guide Version Dahua Technology USA Inc.

CHAPTER 20 SERVICE EQUIPMENT

SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS

Certificate of Compliance

Explosion Protected Panelboards D2Z Series

CLASSIFICATION Constructional Data Report (CDR)

Effective Date: October 2016 Void After: October Product: Air Admittance Valves File No. C-3803

Installation Guide for models:

Installation Instructions Remote Blowers

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Section COMMUNICATION EQUIPMENT ROOM FITTINGS. Section Communications Cabinets, Racks, Frames and Enclosures

CERTIFICATION BULLETIN

Certification Supplement Manual

File EX3836 Project 05CA54707 Project 06NK13655 Project 06NK29644 Project 06NK25809 Project 08CA19260 Project 07NK04786 Project 08CA42763 REPORT

SAFETY INFORMATION AND WARNINGS

Installation and Operation Manual Low Power (LP) DC Power System

Installation Guide for models:

CERTIFICATE OF COMPLIANCE

GUIDE. Installation 5 SERIES. Built-In Electric Cooktops Built-In Induction Cooktops

Installation Instructions

Demystifying Power Tap Use in Healthcare Settings John Garbarino Sr. Marketing Manager, Commercial/Industrial Leviton Manufacturing Co.

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

Descriptive Report and Test Results

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

File EX CA March 31, 2010 REPORT RESIDENTIAL SPRINKLERS. Viking Corp Hastings, MI. Copyright 2010 Underwriters Laboratories Inc.

Burner control unit BCU 370

ccsaus certificate: for GSI 127 Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title Page

Issued: January 13, 2006 Revised: April 21, 2009 REPORT. Automatic Sprinklers. The Viking Corporation Hastings, MI

UL TEST REPORT AND PROCEDURE

Installation Instructions

NXM2G Installation and Operating Manual

AUTODOME IP starlight 5000i

Transcription:

Issue Date: 2011-01-24 Page 1 of 18 Report Reference # E183863-A17-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2007-03 (Information Technology Equipment - Safety - Part 1: General Requirements) Listing NWGQ, NWGQ7 (Information Technology Equipment Including Electrical Business Equipment) Product: Model: AutoDome System AutoDome Series HD: Models VG5-825-ECEV, VG5-825-ETEV, VG5-825-CCEV, VG5-836- ECEV, VG5-836-ETEV, and VG5-836-CCEV. AutoDome Series 700 IP: VG5-713-ECE2, VG5-714-ECE2, VG5-723-ECE2, VG5-724-ECE2, VG5-713-CCEV, VG5-723-CCEV Power Supplies: VG4-A-PAxx; VG4-A-PSUxx; Where x = 0-9 or A-Z or Blank that are non-safety related. Rating: (PA is power box with arm only - no dome, PSU is power box with cover only). 24Vac, 3A, 50/60Hz 120Vac, 0.7A, 60Hz or 230Vac, 0.4A, 50 Hz (not applicable to AutoDome Series HD nor AutoDome Series 700 IP) Applicant Name and Address: BOSCH SECURITY SYSTEMS INC 850 GREENFIELD RD LANCASTER PA 17601 UNITED STATES This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of UL LLC ('UL') in accordance with the Follow- Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. Copyright 2012

Issue Date: 2011-01-24 Page 2 of 18 Report Reference # E183863-A17-UL Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. Prepared by: Keith Wiebe Reviewed by: Michelle Hahnlein Copyright 2012

Issue Date: 2011-01-24 Page 3 of 18 Report Reference # E183863-A17-UL Supporting Documentation The following documents located at the beginning of this Procedure supplement the requirements of this Test Report: A. Authorization - The Authorization page may include additional Factory Identification Code markings. B. Generic Inspection Instructions - i. Part AC details important information which may be applicable to products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report. ii. Part AE details any requirements which may be applicable to all products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report. iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report. Product Description The AutoDome product is for indoor and outdoor use. The in-ceiling dome unit has been further evaluated for air handling space in accordance to UL Standard "Fire Test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air- Handling Spaces", UL 2043, Second Edition. Testing on AutoDome Series, VG4-1, VG4-2, VG4-3, and VG4-5 series is representative based on same construction. See also testing in enclosure Misc for Models VG5-713-CCEV, VG5-723-CCEV and VG5-825-CCEV. The unit configured as 1) power supply in a box as well as 2) power supply with neck and dome has been further evaluated for rain tight in accordance with UL 60950-1, 1st Edition, 2007-10-31 and CSA C22.2 No. 60950-1-03, 1st Edition, 2006-07 which is representative with UL 60950-1, 2nd edition and CSA C22.2 No. 60950-1, 2nd Edition and to IEC 60529, Ed. 2.1 to IP66. The pressurized autodome has also been further evaluated for raintight in accordance with UL 60950-1, 1st Edition and CSA C22.2 No. 60950-1-03, 1st Edition, 2006-07 which is representative with UL 60950-1, 2nd edition and CSA C22.2 No. 60950-1, 2nd Edition and to IEC 60529, Ed. 2.1 to IP 66. For pressurized autodome with the pipe mount, it has been evaluated to IEC 60529, Edition 2.1 for IP 67. The unit configured as the in-ceiling AutoDome has been further evaluated in accordance to IP54. See Enclosure Miscellaneous for test report of IP54. Testing on AutoDome Series, VG4-1, VG4-2, VG4-3, and VG4-5 series is representative based on using the same materials. See also testing in enclosure Misc for Models VG5-713-CCEV, VG5-723-CCEV and VG5-825-CCEV. Units rated 24Vac are intended to be powered by External UL Listed / I.T.E certified power supply, LPS or Class 2. When the unit is utilized for outdoor use, the Environmental Shield is added to the Dome. For indoor use only, there is no Environmental Shield and no heater module utilized. These units are for service access only. When the units are utilized for outdoors, all cables are not exposed and are shielded into the earthed conduit. Power supply box with enclosure is separately Listed within this report.

Issue Date: 2011-01-24 Page 4 of 18 Report Reference # E183863-A17-UL Plenum design is not acceptable for ITE. The pipe interface board assembly is intended to be used for pipe mounting applications. See Photo 3-14 for details. The back box interface module is installed onto the in-ceiling dome for mounting to ceiling tiles. The units can be mounted in various means 1) Wall, Corner, Mast (Pole) Mount. See Section 1 of Enclosure Manual for mounting details; 2) Roof Parapet or Pipe Mount. See Section 2 of Enclosure Manual for mounting details; 3) Mounting In-Ceiling AutoDome. See Section 4 of Enclosure Manual for mounting details. This product does not connect to Telecommunication and /or Cable Distribution system. Model Differences Models VG5-825-ECEV, where the "C" indicates "clear" bubble and VG5-825-ETEV, where the "T" indicates "Tinted Bubble". Models VG5-713-ECE2, VG5-714-ECE2, VG5-723-ECE2, and VG5-724-ECE2 are identical to existing models except for optical magnitude of camera and video output which do not affect safety. Models VG5-713-CCEV, VG5-723-CCEV and VG5-825-CCEV are electrical the same as existing models VG5-713-ECE2, VG5-723-ECE2, and VG5-825-ETEV respectively, except these new models are for inceiling mount which utilizes a larger size enclosure and gasketing. Models VG5-836-ECEV, VG5-836-ETEV, and VG5-836-CCEV are identical to their respective models VG5-825-ECEV, VG5-825-ETEV, and VG5-825-CCEV except for camera model which incorporates same magnitude and color of window which do not affect safety. Technical Considerations Equipment mobility : stationary Connection to the mains : permanent connection Operating condition : continuous Access location : operator accessible Over voltage category (OVC) : OVC II (when rated 120 or 230Vac); OVCI (when rated 24Vac) Mains supply tolerance (%) or absolute mains supply values : +6%, -10% (for rated 120Vac); +10%, - 10% (for rated 230Vac); N/A (for rated 24Vac from external Listed Class 2 or LPS power adapter). Tested for IT power systems : No IT testing, phase-phase voltage (V) : N/A

Issue Date: 2011-01-24 Page 5 of 18 Report Reference # E183863-A17-UL Class of equipment : Class I (earthed) (rated 120 or 230Vac); Class III (SELV) (rated 24Vac) Considered current rating (A) : 20A Pollution degree (PD) : PD 2 IP protection class : IP66 (complete pendant mount assembly with camera and power supply in box); IP54 for in-ceiling AutoDome only, IP66 for pressurized AutoDome and IP67 for pressurized AutoDome with PipeMount. Altitude of operation (m) : 2000 m Altitude of test laboratory (m) : less than 2000 m Mass of equipment (kg) : 9.07 kg The product was investigated to the following additional standards: EN 60950-1:2006+ A11:2009 (which includes all European national differences, including those specified in this test report). The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted by the manufacturer s specification of: 50 C The means of connection to the mains supply is: Permanently connected (field wired) The product is intended for use on the following power systems: TN The equipment disconnect device is considered to be: provided as part of the building installation. The following circuit locations (with circuit/schematic designation) were investigated as a limited power source (LPS): Power source output (24Vac) The class of laser product is: Incorporates previously certified Class 1 laser product. Additional Information Max weight consist of Dome Camera Assembly, Power Supply and Arm Assembly is 20 pounds. The marking plate label noted in Enclosure Marking Plate ID 13-01 is representative of the Power Supply series. The marking plate label noted in Enclosure Marking Plate ID 13-02 is representative of the AutoDome series HD. The marking plate label noted in Enclosure Marking Plate ID 13-03 is representative of the AutoDome Series 700 IP. Markings and instructions

Issue Date: 2011-01-24 Page 6 of 18 Report Reference # E183863-A17-UL Clause Title For units intended to be installed outdoors (See model nomenclature in enclosure "Miscellaneous") Marking or Instruction Details Following or equivalent installation instruction: "All wiring connecting to this unit must be routed inside a permanently earthed metal conduit" See manual pages 5 and 19 per enclosure "Manual", supplement Id 6-01. Manual attached in enclosure "Manual", supplement Id 6-01: The following or similar wording shall be included in the manual; See manual pages 5, 6, 7, 9, 19, 22, 25, 26, and 29, marked with asterisk. A) Must use UL Listed Liquid Tight Strain Reliefs for Conduits; B) External Interconnecting Cables are to be installed in accordance to NEC, ANSI/NFPA70 (for US application) and Canadian Electrical Code, Part I, CSA C22.1 (for CAN application) and in accordance to local country codes for all other countries. C) the branch cicuit protection is 20A as is provided as part of the building installation. D) A readily accessible disconnect device shall be incorporated in the building installation wiring. E) Unambiguous reference to service documentation for instructions for replacement of fuses replaceable only by service personnel; F) Short Circuit/Overcurrent Protection: Instructions indicate Listed circuit breaker or branch rated fuse, rating, number of poles, special characteristics; G) Mounting Instructions - Indicates min thickness of wood 3/4 ". The manual for AutoDome Series HD will be representative for the requirements to Manual for AutoDome Series 700 IP. Manual Instructions for Pipe Mounting In order to maintain the type rating of the 4 and 4X Enclosure, the installation manual shall state the following or similar wording: "A. The end of the Pipe Mount that is meant to terminate into an enclosure is intended to be field installed and shall be marked or provided with instructions that identify the equipment necessary to maintain the environmental integrity of the enclosure: In order to maintain the integrity of a Type 4X environment, equipment connected needs to have a Type 4X environmental rating. In order to maintain the integrity of a Type 4 environment, equipment connected needs to have a Type 4, 4X, 6 or 6P environmental rating. B. Thread Sealing Compound for pipe mounting must be used and must be Teflon Tape. C. All screws shall be securely tightened." Marking Label/Instructions - Raintight The product may be marked "RainTight". 1.7.1 Power rating - Ratings Ratings (voltage, frequency/dc, current) 1.7.1 Power rating - Company Listee's or Recognized company's name, Trade Name, Trademark or File Number

Issue Date: 2011-01-24 Page 7 of 18 Report Reference # E183863-A17-UL identification 1.7.1 Power rating - Model Model Number 1.7.2 Disconnect device - Permanently connected equipment Statement indicating that a readily accessible disconnect device shall be incorporated in the building installation wiring. (Instruction) 1.7.6 Fuses - Non-operator access/soldered-in fuses Unambiguous reference to service documentation for instructions for replacement of fuses replaceable only by service personnel 2.7.1 Short Circuit/Overcurrent protection for Pluggable B or permanently connected equipment Installation Instructions indicate Listed circuit breaker or branch rated fuse, rating, number of poles, special characteristics. 1.7.7.2 Terminals for external primary power supply conductors Capital letter "N" located adjacent to a terminal intended exclusively for connection of the primary power neutral conductor 1.7.7 Class 2/3 terminals "Class 2" or "Class 2 output" Special Instructions to UL Representative N/A