R407C 220-240V ~, 50Hz Hi - Wall Split Systems Technology Tropical Compressor Super Quiet Auto Mode Auto Restart Easy Flexible Installation IAQ Anti-dust Filters AMS AMS Wireless Control Independent Dehumidification Min. Minutes Time Delay Easy Fast Maintenance Self Clean Fans Smart Airflow Anti Freezing Anti-Freezing Protection Cleanable Front Panel Fashion Design Coils Vertical Auto Swing SLEEP Self diagnostic function Washable Air Filter LED Display Inner Groove Copper Tubing Horizontal Manual Swing Timer s Refrigerant Leak Detection $ Operation Hydrophilic Aluminum Fins Auto Auto Fan Speed Follow Me
Hi - Wall Split Systems R407C Cool Only High Wall Split is the optimum air conditioning solution for the places which require only high wall installations, elegant appearance and ultimate comfort combined with efficient and quiet operation, optimum air distribution, efficient Indoor Air Quality (IAQ) and green refrigerant R407C. KET FEATURES SMART CONTROL Healthy & Clean Indoor Air Quality (IAQ) generates large quantity of negative ions for refreshing air, killing germs, removing smoke and dust particles. gives an immediate sensation of energy and well-being. anti dust washable air filters for clean and healthy air. IAQ Self Clean function to clean and dry the indoor coil of indoor unit to prevent the bleeding of odors and bacteria. Infrared wireless remote OUTDOOR UNIT Modern Aesthetic Design Compact indoor unit with attractive appearance fits any interior decor with space saving. New stylish outdoor unit look. Smart LED display shows control functions and error code in case of a malfunction. 8QPCT EFFICIENT, TROPICAL & QUIET $ EFFICIENT AIR FILTRATION Tropical Operation with Minimum Electrical Consumption Patented heat transfer and aerodynamics technologies to ensure prefect operation up to 52 C outdoor ambient temperature for energy saving and low operating cost. tropical rotary compressor works in high ambient up to 52 C with high efficiency and low electrical consumption leading to true powerful system cooling. Air Management System (AMS) leading to maximum air flow with minimum turbulence for minimum air resistance, smooth airflow and efficient operation. Carrier innovative uneven aerofoil tangential blower technology for efficient operation at all speeds with maximum air flow. indoor and outdoor coils with large heat transfer surfaces for minimum electrical consumption. $ AMS www.miraco.com.eg Anti-dust Air Filters Quality Management System ISO 9001 : 2008 Certificate No.: QS-5519HH Indoor Fan Enviromental Management System ISO 14001 : 2004 Certificate No : 12 104 04 TMS Safety Management System BS OHSAS 18001 : 2007 Certificate No : 12 116 04 TMS trapeziform Inner groove copper tubing compared with traditional copper tubing, it allow more refrigerant flow, improving heat exchange efficiency and lowering power consumption while keeping the same capacity output level. Precoated Hydrophilic Aluminum Fins of indoor coil to protect the coil against corrosion and to allow easy and quick removal of unrestricted condensate water between the fins to increase airflow, improve efficiency of heat exchange and accelerate cooling.
Key Features Comfort & Quiet with Minimum Sound Level Patented cross flow fan, elephant ear propeller, new heat exchangers, improved Air Management System (AMS), and quiet rotary compressor. Smart LCD infrared wireless remote control with complete control and safety functions built in the control system to ensure efficiency and safety at all operating conditions. Smart supply air flow for comfort cool and heat as per selected mode for optimal air distribution of supply air temperature and velocity inside the air conditioned space. Auto-swing horizontal supply air flap to up and down for optimal air distribution of supply air temperature and velocity inside the air conditioned space. Manual direction of vertical supply air flaps to right and left for optimal air distribution of supply air temperature and velocity inside the air conditioned space. Auto fan speed which changes the fan speed automatically to high or medium or low fan speed by sensing the temperature difference between room temperature and set temperature. Auto mode which changes the operation mode and capacity output automatically according to temperature difference between room temperature and set temperature. Independent Dehumidification mode which dehumidifies the room efficiently, but not lower the temperature so obviously as cooling operation. function for economical running and energy saving which automatically changes fan speed to Auto speed and changes set temperature to 24 C for cool and 26 C for heat. Sleep function for energy saving and comfortable healthy sleep which automatically changes fan speed to low speed and controls both set and room temperatures. Programmable timer for easy on and off selection with energy savings including off timer, on timer, off/on timer and on/off timer functions. Follow Me function for smart control of comfortable temperature when you stay close to the remote control. With this technology, an efficient sensitive temperature sensor is built in the remote control just like the air conditioner is following you. Auto Durability Anti-rust, weather proof and long life outdoor unit sheet metal parts made of chemically treated and zinc coated ( galvanized ) sheet metal. Powder painted casing of outdoor unit with prefect adhesion of highly resistant ployester paint 60-80 microns thick, which is electro-statically applied and baked at a temperature of 220 C. Safety & Reliability Auto restart function with backup memory. When the power failure is happened during the air conditioner operation, the microprocessor of printed circuit board will memorize the operation settings. After the power is recovered, the air conditioner operates automatically ( without remote control after elapse of compressor time delay ), according to the previous operation settings. (three) minutes safety time delay between compressor turning off and turning on for compressor protection against cycling. Anti-freezing protection of indoor coil when the system is operating in cool mode with excessive dirt on the indoor coil and / or clogged air filters and when the air conditioner is operating in heat mode at low ambient temperature. Smart self-diagnostic function for malfunctions detection for easy fast service and maintenance. Smart Refrigerant leak detection by sensitive sensors mounted on the indoor and outdoor coils for easy fast service and maintenance. Easy Installation, Service & Maintenance Flexible multi outlet locations for piping from the indoor unit, easy piping connections and easy electrical connections between outdoor and indoor units. Easy accessibility to all key components. Common spare parts across product family. Easy removal of front panel for cleaning by easy disassembly of panel engagement with indoor unit cabinet. Easy removal of washable air filters for cleaning by opening the hinged front panel up and then pulling filters down outside the indoor unit. Min. Anti Freezing Rev. (0) - 2012
Hi - Wall Split Systems Key Features Technology generates large quantity of negative ions for refreshing air, killing germs, removing smoke and dust particles. gives an immediate sensation of energy and well-being. has the following advantages : Eliminates bacteria and dust mites. Remove bad odors, smoke and domestic smells. Eliminates potentially pollutants and chemicals. Alleviates fatigue, allergies, body paints and disease. Increase feeling of calmness, reducing irritability and depression. Improves energy and alertness. Smart Air flow Smart supply air flow for comfort cool and heat as per selected mode for optimal air distribution of supply air temperature and velocity inside the air conditioned space. Cool Mode www.miraco.com.eg Temperature Compensation Temperature Compensation based on different installation height of indoor unit, the temperature deviation of the sensor sensed against the actual floor temperature always is different. Changing the jumping wires combination on the indoor PCB is possible to compensate the deviation. This could be achieved by installer in the installation field. Cool Mode
Follow Me Key Features When Follow Me function is activated, the room temperature sensor built in the remote control is activated and replaces the sensor of the indoor unit. Then the air conditioner regulates the room temperature based on the temperature around the remote control. Carrier Follow Me technology makes your air conditioner follow you for smart comfortable temperature. Normal Operation Operation with Follow Me ( SLEEP ) - Sleep function is useful when you go to sleep. This function is useful for energy saving, quiet and comfortable healthy sleep. - When sleep function is activated the air conditioner changes the set temperature automatically which in turn changes the room temperature automatically to maintain the most comfortable temperature and to avoid overcooling during cool mode or overheating during heat model. Rev. (0) - 2012
Hi - Wall Split Systems Wireless Remote Control Display Of Remote Control 1 2 www.miraco.com.eg 1 54 10 9 6 15 16 17 Control Buttons 1 2 4 5 6 7 8 9 10 11 12 1 14 15 16 17 MODE selection button Decrease temperature button Increase temperature button FAN SPEED selection button ON/OFF button IONIZER function button FOLLOW ME function button SELF CLEAN function button SLEEP function button function button CLOCK function button TIMER ON or TIMER OFF function button CANCEL function button LED display function button RESET function button F/C ( Fahrenheit or Celsius ) setting function button 2 12 1 14 11 8 7 1 2 AUTO COOL DRY FAN 4 5 6 7 8 AUTO LOW MED HIGH 9 10 11 12 1 10 5 4 12 9 AUTO COOL SET TEMP. o SPEED AUTO LOW MED HIGH Signal transmission indicator MODE indicator Automatic (heat pump model only) Ventilation (fan only) ON / OFF indicator SET TEMP. indicator Temperature unit of measurement (ºC or ºF) CLOCK indicator DRY TIMER ON TIMER OFF 8 TIMER ON or TIMER OFF function indicator FAN SPEED indicator FAN SPEED indicator AUTO FAN SPEED indicator LOW FAN SPEED indicator MED FAN SPEED indicator HIGH SLEEP function indicator function indicator IONIZER function indicator FOLLOW ME function indicator LOCK function indicator Displayed Of Indoor Unit OPERATION green led TIMER orange led IONIZER blue led FAN CLOCK 11 6 7 1
Super Safety Protections For System Reliability Malfunction Reason Flashing frequency Allowed Mode Return Air Sensor (open or short circuit) Fan Only Indoor Coil Sensor (open or short circuit) 2 Fan Only Compressor Drive 5 Fan Only Power Line Feedback (zero crossing) 9 - Rev. (0) - 2012
Hi - Wall Split Systems Technical Specifications www.miraco.com.eg System size 18 24 System type Cool only System model 5QPCT18CN2-708F 5QPCT24CN2-708F Indoor unit model 42QPCT18CN2-708F 42QPCT24CN2-708F Outdoor unit model 8QPCT18CN2-708 8QPCT24CN2-708 Cooling capacity @ 5ºC / 46ºC Ambient Btu/hr 18000 / 15895 22000 / 1940 kw 5.27 / 4.66 6.45 / 5.69 Rated input - cooling @ 5ºC / 46ºC Ambient W 1978 / 2290 200 / 2660 Rated current- cooling @ 5ºC / 46ºC Ambient A 8.9 / 10. 10 / 11.6 E.E.R. - Cooling @ 5ºC / 46ºC Ambient Btu/wh 9.10 / 6.94 9.56 / 7.0 W/W 2.66 / 2.0 2.80 / 2.14 Indoor unit model 42QPCT18CN2-708F 42QPCT24CN2-708F Dehumidification l/h 2.4 2.8 Nominal air flow (low/med/high) cfm 485 / 57 / 590 485 / 57 / 590 m /hr 822 / 910 / 1000 822 / 910 / 1000 Sound Pressure (low/med/high) db(a) 44 / 47 / 49 44 / 47 / 49 Net Dimensions (W H D) mm 44 / 47 / 49 44 / 47 / 49 Net Weight kg 14 14 Outdoor unit model 8QPCT18CN2-708 8QPCT24CN2-708 Tropical Compressor type Rotary Rotary Refrigerant type / Coupler type R407C / Flare R407C / Flare Sound pressure db(a) 60 62 Net Dimensions (W H D) mm 860 575 50 860 575 50 Net Weight kg 52.8 58.5 Installation data Pipe connection sizes Liquid /8 /8 Gas 5/8 5/8 Maximum pipe length m 20 20 Maximum height difference m 10 10 Condensate drain hose diameter 5/8 5/8 Recommended Wire Size / No. of Wires for Power Supply mm 2 /qty to Outdoor Unit 4mm 2 (2 Wires+1 Earth) Recommended Wire Size / No. of Wires for Controls from mm 2 /qty Outdoor Unit to Indoor Unit 1mm 2 ( Wires+1 Earth) Power supply V-ph-Hz 220-240/1/50 * Cooling Capacity and Energy Efficiency Ratio (EER) @ 5ºC ambient are based UAE.S ISO 5151:2011 & UAE.S 5010:2011 at : 27/19ºC db/wb Indoor Temperature. 20 volts power supply. High Air Flow * Cooling Capacity and Energy Efficiency Ratio (EER) @ 46ºC ambient are based UAE.S ISO 5151:2011 & UAE.S 5010:2011 at : 29/19ºC db/wb Indoor Temperature. 20 volts power supply. High Air Flow * Systems work in cooling at high ambient temperature up to 52ºC * Systems comply with Safety Standards IEC 605-2-40 * Carrier is committed to continuously improving its products according to national and international standards to ensure the highest quality and reliability standards, and to meet market regulations and requirements. All specifications subject to change without prior notice according to Carrier policy of continuous development.