DH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS. OPTIONAL ACCESSORIES Two Row Hot Water Coil

Similar documents
The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 20 TONS

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

Models PF1A PF1B PACKAGED AIR-HANDLING UNITS. 6to10Tons. Form No. PDS PF1A.72.1 FEATURES/BENEFITS

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

C13-Series Engineering Guide

Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.

Product Data FEATURES/BENEFITS 524J***H 6 TO 20 TON DIRECT EXPANSION PACKAGED HEAT PUMP AIR -HANDLING UNIT. Indoor air quality features 524J-H 07-12

Product Data FEATURES/BENEFITS. 524J PACKAGED AIR -HANDLING UNITS WITH PURONr REFRIGERANT SIZES 07, 08, 12, 14, 16. Indoor air quality features

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

FCC Fan-Coil Units High-Performance, Vertical

BAC / BHC SERIES 7-1/2 to 20 Ton Air Handlers

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Product Specifications. Vertical Floor Consoles By First Co.

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

VertiCool Aurora Engineering Guide

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

CWA4 Chilled & Hot Water Fan Coil

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

engineering guide FH Fan-Coil Units Low-Profile, Horizontal

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

Condensing Units & Air Handlers

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

DEDICATED VERTICAL/WALL MOUNT

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

Product Data. 50ZH Single-Packaged Heat Pumps. 2 to 5 Tons. Features/Benefits

catalog CDV Fan-Coil Units High-Performance, Vertical

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

engineering guide FN Fan-Coil Units High-Performance, Horizontal

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

Horizontal and Vertical DIRECT DRIVE BLOWER COIL UNITS. Rating and selection at

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

Product Data. 50ZP Single-Package Air Conditioners. 2 to 5 Tons

SSL & SBS Engineering Guide

Product Data. 40RUA/40RUS 6to15TonDirectExpansion 7.5to15TonChilledWater Packaged Air---Handling Units FEATURES/BENEFITS. Indoor air quality features

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

PRODUCT CATALOG BLOWER COILS.

Cooling/Heat Pump Convertible Air Handlers

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons

Variable Speed Convertible Air Handler 5 Ton

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

MAC N-407 Air-Cooled Chiller

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Fan Coils & Air Handlers Product Catalog

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving

Model PA1Z SINGLE PACKAGED AIR CONDITIONERS. Size SS-PA1Z-01 DESCRIPTION FEATURES

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

ARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

High Heat COP. High/Low Stage

MACH N-407 Heat Pump Air-Cooled Chiller

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

PAJ3. Product Specifications

Transcription:

DH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS OPTIONAL ACCESSORIES Two Row Hot Water Coil MAGIC AIRE DH SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN SAFETY STANDARDS AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. UNITED ELECTRIC COMPANY, L.P.

GUIDE SPECIFICATIONS Magic Aire Fan Coil Unit HVAC Guide Specifications Size Range: to Nominal CFM Part General. SYSTEM DESCRIPTION Part Product General: C. Coils: water. DHB.

MODEL NOMENCLATURE AND SPECIFICATIONS DHB Model Number Nomenclature Position Example D H B B A R A A A A M Model Series M -- Not Used DHB-- DIRECT DRIVE Horizontal Mount DRAIN PAN OPTIONS A -- Galvanized Unit Size Nominal Tons B -- Stainless Steel -- -- -- CFM CFM CFM... DISCHARGE AIR ARRANGEMENT -- CFM. A -- Standard - Vertical PRIMARY COIL TYPE AND CAPACITY CONTROLS Type Rows Metering A -- Junction Box Only -- B -- None Chilled Water/Hot Water/-Pipe N/A N/A N/A J -- DX/R- Orifice MOTOR POWER SUPPLY K -- DX/R- TXV -- // M -- DX/R-A TXV -- -- /// // FUTURE USE A -- not used COIL CONFIGURATION R -- Re-Heat Right Hand (Cooling & Heating Coil) or N/A S -- Re-Heat Left Hand (Cooling & Heating Coil) COIL TREATMENT A -- No Coil Treatment P -- Phenolic Coating - Single Coil Model DHB DHB DHB Face Area Sq. Ft.... DH Series Specifications Nominal Motor Throwaway Coil Connections Coil Motor Filters (O.D. Sweat) Unit Rating HP Blower Rows Tube HP /" Thick Shipping in v & Size DX Dia v (Actual Size) Water Weight Tons -v Liquid Suction /" / / -. X. /" /" /" /". / / - X. /" /" /" /" / / -. X /" /" /" DHB. /". / / -. X. /" /" /" Motors PSC RPM; Speed Wall Switch (opt.) Model DHB DHB DHB DHB DH Series Electrical Data Motor Voltage Phase HP FLA MCA MOPD /.. - /.. /.... - /.... Notes:... MCA = Minimum Circuit Ampacity - /... MOPD = Maximum Overcurrent Protective Device, in amps.... FLA = Full Load Amps... HP = Motor nominal horsepower. - /... All motors are Hz.... Use minimum wire size # AWG C wire at unit. DHB. Page //

DHB- HORIZONTAL DIRECT DRIVE AIR HANDLING UNIT DHB. Page //

DHB- SERVICE CLEARANCES DHB. Page //

DH Series AIR F DH CFM vs. External Static for Standard Unit MODEL SPEED SETTINGS. ESP CFM. ESP CFM. ESP CFM. ESP CFM. ESP CFM DHB DHB DHB DHB DH with HH- CFM vs. External Static for Standard Unit with Hot Water Coil MODEL SPEED SETTINGS. ESP CFM. ESP CFM. ESP CFM. ESP CFM. ESP CFM DHB w/hh-- DHB w/hh-- DHB w/hh-- DHB w/hh-- DHB. Page //

DHB Row DX Coil DH Series DIRECT EXPANSION COOLING CAPACITIES DHB Row DX Coil DHB Row DX Coil DHB Row DX Coil DHB. Page //

CHILLED WATER COOLING CAPACITIES DHB Row CHW Coil deg F DB / deg F WB deg F DB / deg F WB deg F DB / deg F WB ENT WTR GPM P D FT. CFM F F DB WB DB WB DB WB EG D F....................................................................................................................................................................................................................................................................................................................................................................................................................................... DHB Row CHW Coil deg F DB / deg F WB deg F DB / deg F WB deg F DB / deg F WB ENT WTR GPM P D FT. CFM F F DB WB DB WB DB WB EG D F....................................................................................................................................................................................................................................................................................................................................................................................................................................... DHB. Page //

CHILLED WATER COOLING CAPACITIES DHB Row CHW Coil deg F DB / deg F WB deg F DB / deg F WB deg F DB / deg F WB ENT WTR GPM P D FT. CFM F F DB WB DB WB DB WB EG D F....................................................................................................................................................................................................................................................................................................................................................................................................................................... DHB Row CHW Coil deg F DB / deg F WB deg F DB / deg F WB deg F DB / deg F WB ENT WTR GPM P D FT. CFM F F DB WB DB WB DB WB EG D F....................................................................................................................................................................................................................................................................................................................................................................................................................................... DHB. Page //

DH Series Heating Capacities For Row Hydronic Coil Capacities calculated and based on entering air temperatures of degrees. Units not recommended for heating applications when leaving air exceeds degrees. Entering Air Temp (F) HOT WATER HEATING CORRECTION FACTORS Entering Water Temp (F) o o o o o o o o o......... o......... o......... o......... o......... o......... o......... When correction factors are used for various entering water temperatures, multiply the correction factor times the E.W.T. capacity. The correction factors may be used with all Magic Aire published E.W.T. heating capacities. o DHB. Page //

TYPICAL WIRING DIAGRAMS REFER TO NAMEPLATE FOR PROPER VOLTAGE VOLTAGE WIRING VOLTAGE WIRING Wiring, transformer, fan relay and terminal strips FIELD PROVIDED. Transformer Primary must match Supply Voltage. GND L/N TRAN V L R THERMOSTAT {C G FAN MOTOR SINGLE PHASE RELAY/CONTACTOR L (H) L (N) YEL BRN OFF AUX SWITCH OPEN IN "OFF" POSITION AUX SW HI BLK BLK M BLU BLU LO RED RED H M L FAN MOTOR WHT ORG OPTIONAL SPEED SWITCH DHB. Page //

DH Series HORIZONTAL HOT WATER COILS AIRF G F A HH-,, and - Series for DH Models C D H E B TOP /" OUTLET G /" INLET The Hot Water Coils are to be field installed on the discharge side of the unit. When the hot water coils section is placed on the discharge end of the DH unit, a flange will extend over the unit on the top and bottom. Install screws in these flanges to secure the hot water coil to the unit. Hot Water Section Cabinet Dimensions SIDE H MODEL A B C D E F G H SHIPPING WEIGHTS HH--..... HH--..... HH--..... HH--..... Two Row Hot Water Heating Capacities (Not Suitable for Steam) Capacities calculated and based on entering air temperatures of degrees. Units not recommended for heating applications when leaving air exceeds degrees. DHB. Page //

DHB.

ENGINEERING SPECIFICATIONS United Electric Company designs and builds its Magic Aire products to comply and perform to the following standards: AIR F General AMCA ASHRAE COIL CAPACITY Hydronic Direct Expansion ARI ARI SAFETY AGENCY LISTINGS Equipment ANSI/UL-- MATERIAL SPECIFICATIONS MAJOR COMPONENTS Sheet Metal Copper Tubing Aluminum Motors Wire Electrical Filters Fiberglass Paint ASTM A ASTM A ASTM B ASTM B ASTM B ASTM B ASTM B UL/CSA NEMA UL/CSA UL/CSA UL ASHRAE UL UL (/) ASTM E- ASTM B MAGIC AIRE DH SERIES FAN COILS ARE ETL LISTED TO U.S. AND CANADIAN SAFETY STANDARDS AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. UNITED ELECTRIC COMPANY, L.P. DHB. www. magicaire.com //