THE TRUSTED ADIABATIC COOLER AND CONDENSER

Similar documents
TOPAZ ADIABATIC COOLER

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

EcoCooler Legionella Risk Assessment Information Pack

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

AQUASNAP JUNIOR 30RHV

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Be sustainable while protecting your business

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Water-cooled chillers with High Speed Centrifugal Compressors

HYBRID ADIABATIC Cooling System

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SYSTEM DESIGN REQUIREMENTS

TrilliumSeries Condenser 1 TRILLIUMSERIES CONDENSER 10 ECOFLEX CONTROLS 11 SELECTION AND PAYBACK ANALYSIS SOFTWARE 3 BENEFITS 8 MODES OF OPERATION

AIR COOLED PACKAGED CHILLER

LZT High efficiency air to water heat pumps with E.V.I. compressors

Data Centre Cooling Solutions

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Data Centre Cooling Solutions

Aquaflair TRAC-TRAF-TRAH

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

Technical Development Program

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

Presenters. Brett Alexander. Mihir Kalyani. Troy Reineck

I.O.M. #116 7/10 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE. Covers Models from 25 to 100 tons.

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

Guide Specifications PART 1 GENERAL 1.01 SUMMARY

PACKAGE AIR CONDITIONER

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

LZA High efficiency air to water heat pumps with HP compressor

Product Data Sheet Refrigerant Dryer DFLO-ES 66 (-W) to DFLO-ES 660 (-W) with energy saving management

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Guide Specifications for InRow Direct Expansion

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

GUIDE SPECIFICATIONS AQUARIUS ii

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

AIR COOLED CONDENSERS

MAC-120HE-03 Air-Cooled Chiller

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

Condensing Units CUS 15-60

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

MAC N-407 Air-Cooled Chiller

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

Air cooled industrial chillers

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

RTU. Roof Top Units 8 30 Ton. Maxi-Kool.

Air Handling Units. Real HVACR people who understand your needs.

KELVIN Clim F497. Kelvin air conditioning

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

2003 METAL FORM MFG. FORM NO: PCIOM/03

GUIDE SPECIFICATIONS AQUARIUS ii

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

air systems Large Rooftop DIC-BIH-DIG 360 to 480 G

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Air-Cooled Condensers

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

CWA4 Chilled & Hot Water Fan Coil

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Product Data Sheet Refrigeration Dryer DFLO 66 (-W) bis DFLO 2400 (-W)

Commercial High-Efficiency Condensing Units

PAJ3. Product Specifications

EHH SERIES DRAW THROUGH FAN COILS CFM

Transcription:

THE TRUSTED ADIABATIC COOLER AND CONDENSER

The Trusted Adiabatic Cooler and Condenser SPARTIUM origins trace back to 1962 by joining the European Air Conditioning industry. At that time the U.S.A. was the only available source of know-how and equipment supply. In 1967 the company joined the new formed cluster of European manufacturers of HVAC equipment by establishing its own factory in Thessaloniki, Greece. To safeguard the integrity of its equipment performance, was one of the first 32 companies in 1993 to participate in Eurovent s originally established Certification Programme. During the turn of the century the company made an innovative breakthrough in designing, manufacturing and testing the SPARTIUM Adiabatic Cooler and Condenser. The prototype Adiabatic Fluid Cooler won the Innovation Award at the 2006 Interclima Exhibition in Paris and it was selected as a top innovation product for its impressive water saving features, combined with a unique safety operational concept. The greatest success feature however of those new product lines was the hygienic characteristics and the ability to contain the risk of Legionellosis associated with water systems in buildings and, therefore, fully complied with the strict legislation enforced in France, the United Kingdom and Spain. SPARTIUM achieved reliable manufacturing excellence every time and all the times through a vertically integrated manufacturing process, allowing quick response and adaptations to market s needs. Manufacturing applies a strict Quality Management System as per EN ISO 9001:2008 in accordance with the procedures of the Certification Body at TÜV NORD CERT GmBH and a Quality System for Pressure Equipment Manufacturer according to the EU Directive. 3

Why Adiabatic Cooling The Adiabatic Process SPARTIUM Adiabatic Cooling units incorporate engineering solutions for water or glycol cooling, or for condensing refrigerants. The water is evaporated into the air stream which through an engineered pad is chilled with heat taken from it, thus in an adiabatic state. The colder air as it passes in turn through a finned heat exchanger cools the hot process fluid to a much lower temperature or pressure level, increasing its heat rejection capacity of up to 40% more than what is achieved by a dry cooler or air cooled condenser. FEATURES OF THE SPARTIUM ADIABATIC COOLING Water Saving The SPARTIUM Adiabatic coolers and condensers do not use re-circulated water and therefore no bleed-off is required. This advantage in addition to the adiabatic cooling of the entering air, depending on the local climatic conditions, may result to more than 80% annual water saving compared to cooling towers, closed circuit cooling towers and evaporative condensers. Furthermore the chance of water droplets entrained in the air stream is totally eliminated with the SPARTIUM Cooler because during the humidification of the air no aerosols are produced since the transfer of humidity takes place at molecular level. During the annual operation of an Adiabatic Cooler, but even during the daily load requirements, the entering ambient dry bulb air temperature is often below the depressed dry bulb temperature coming out of the pad section of the unit. During all such periods the unit s software control system cuts off the wetting of the pads and the system runs dry. In addition, during the off season, the pads can be easily removed and the unit s dry operation can be further enhanced by the increased air flow, resulting to water saving. Electricity Saving The SPARTIUM units controller s software modulates the speed of the fans through their electronically commutated (EC) motors according to the load demands, before the pad wetting is energized. This fan speed modulation results to significant energy consumption savings. Choice of Operational Predominance The SPARTIUM family of products are ideal for installation in areas of water scarcity against other types of cooling equipment due to minimal water consumption and considerable higher thermal performance. On the contrary in areas where water is no issue, the software of the units allow more extensive use of the pre-cooling of the air and thus operation at lower fan speeds at considerable reduced electricity consumption. The control system also allows night operation during which the maximum allowable speed of the fans is reduced by energizing pre-cooling earlier achieving also a lower noise level. 4

Operational Safety - Legionella and the prevention of legionellosis. Legionellosis infections were identified in the second half of the 20 th century, caused by the legionella bacteria. The severity of the infections varies from mild febrile illness to a potential fatal form of pneumonia (Legionnaires disease) that can affect anyone in the vicinity. Water is the major natural reservoir for legionellae and the bacteria are found worldwide in many different natural and artificial aquatic environments such as water systems in hotels, hospitals, ships and factories. Water temperature above 25 C is a crucial factor for the bacteria colonization, when stagnant in equipment and in water distribution systems. Cooling towers and evaporative condensers have historically been implicated in numerous outbreaks of Legionnaires disease. The major risk factor for legionellae proliferation in these systems appear to be neglect or insufficient maintenance. Surveillance for Legionnaires disease is now a statutory notifiable disease in most industrialized countries. The SPARTIUM family of products are specifically designed to restrain legionella s colonization: Limited Maintenance Requirements. Due to is concept, design and construction the SPARTIUM equipment requires limited maintenance and there is no need for any main water supply pretreatment. By its factory adjusted city water calibrated metering devices, the wetting of the pads is secured and a certain amount of excess water is continuously flashing dirt and debris from the surface of the pads, prolonging their useful life. A tough and resilient edge treatment applied to the entering face of the pads allows frequent surface cleaning without damaging the pad and routine maintenance can be performed while the unit is still operating. unlike a cooling tower, it has no sump, where the legionella bacteria can proliferate at the commonly encountered temperatures in such equipment of 25 C and above. in the case the adiabatic process is interrupted the unit incorporates an intelligent control system that drains the water in its pre-cooling pad distribution system via an automatic operation of the valves, through the inclined gutter system, so that no stagnant water remains at any time in any part of the unit. because of the adopted low air velocity through the cooling pads and their design and construction, there is no water carry over, or aerosol generation. 5

Technical Data of Adiabatic Coolers Heat Exchangers in V Configuration (*) Nominal capacities based on 35 o C / 29 o C inlet/outlet water temperature, and ambient entering air 35 o C db / 21 o C wb Heat Exchangers in Vertical Configuration (*) Nominal capacities based on 35 o C / 29 o C inlet/outlet water temperature, and ambient entering air 35 o C db / 21 o C wb 6

Technical Data of Halocarbon Adiabatic Condensers Halocarbon Refrigerants (*) Nominal capacities refer to R134a, based on 40 o C condensing temperature, and ambient entering air 35 o C db / 21 o C wb Technical Data of Ammonia Adiabatic Condensers Ammonia Refrigerants (*) Nominal capacities based on 40 o C condensing temperature, and ambient entering air 35 o C db / 21 o C wb 7

Standard & Optional Components Electrical Panels and Control Logic The SPARTIUM Cooler is a plug-and-play cooling unit fully wired and programmed at the factory and only needs to be connected to the grid and its pad wetting piping to the city water supply. The factory installed Power and Control Panels in IP55 enclosure include main magnetic power switch, emergency stop, power failure reset, individual fan motor circuit breakers, microprocessor controller with display, wired to immersion temperature or pressure sensor, and ambient air sensor. The software activates or stops adiabatic pre-cooing in steps on the basis of a pre-programmed logical combination of the fan speed and the ambient temperature. Optional items include a General Contactor Relay; an Inverter by-pass Switch (for units with AC fans); an Electric Internal Heater with fan, thermostat and circuit breaker; BMS communication cards. Internal Fan Compartment Partitions supplied as standard, ensure a uniform and swirl free flow of the air to each individual fan, reducing noise vibration and eliminating flow obstacles. In case of an idle fan the partitions prevent air bypassing the heat exchangers. Pad Edge Treatment supplied as standard, a tough and resilient pad edge treatment applied to the air entering face of the pads. It has been constructed to withstand repeated cleaning without damaging the pad and prevents algae and minerals from anchoring into the substrate of the pad. 10

Sloping Fully Drainable Gutter Any excess city water after wetting the pads cleans them from any debris and drains itself through fully drainable sloping gutters ensuring that no stagnant water remains behind. Pre-cooler Frame in Stainless Steel As an option, the pre-cooler frames can be furnished in heavy gauge stainless steel construction. Pad Wetting Metering Devices The anticipated city water flow for the wetting of the pads is strictly controlled by a metering device with calibrated water scale in l/min. The devices can be re-adjusted in the field depending on local conditions. Service Switch If local regulations warrant it, a Service Switch can be installed next to each fan, as an optional item, allowing the interruption of the power supply before any intervention is needed to a particular fan. The switch is supplied in an IP65 enclosure. Fin Epoxy Coating If resistance to corrosion in aggressive environments is needed, then the heat exchangers can be constructed with aluminium finstock coated with epoxy lacquer. 11

General Specifications The SPARTIUM Adiabatic Cooler and Condenser is an integral combination of five major components: the adiabatic cooling pad section; the heat exchangers section; the air movement package; the electrical and control installation and the steel supporting frame. ADIABATIC PRE-COOLER HEAT EXCHANGER The cooling pad section serves as an adiabatic saturator to cool the incoming air. It consists of specially impregnated and corrugated cellulose paper sheets with flute angles that have been bonded together, with high evaporation efficiency while still operating with a very low pressure drop. The impregnation procedure for the cellulose paper ensures a strong self supporting product, with high absorbance, which is protected against decomposition and rotting. A pipe circuit supplies the evaporative fluid, such as city water, to a distribution manifold and the rate of the water flow is initially regulated by a special metering device which throttles the correct flow rate. An inlet air edge coating developed specially for harsh and tough conditions prevents the pad surface from extreme environment such as dirt, sand storm, and risk of bacterial and algae growth. A distribution pad on the top of the cooling pad ensures an even water distribution and minimizes the risk of dry spots. The water flows down the corrugated surface of the evaporative cooling pad. The incoming warm and dry air that passes through the pad evaporates most of the water. Any remaining water assists in washing the pad, and is drained to the gutter through a sloping pan. The air that leaves the pad is therefore cooled and humidified simultaneously without any external energy supply, thus adiabatically. The Finned Coil Heat Exchangers of the Coolers and halocarbon refrigerant Condensers consists of SF-Cu seamless tubes and aluminum fins. Staggered tube construction provides substantially higher capacity since more tubes are exposed to the air stream. The advanced rippled-corrugated fin design creates a state of continuous turbulence, which effectively reduces the boundary layer formation that could otherwise reduce the rate of heat exchange. Fins have full drawn collars to maintain fin spacing and provide a continuous surface cover over the entire tube. The tubes are mechanically expanded into the fin collars to provide a continuous primary to secondary compression bond over the entire finned length for maximum heat transfer rates. Headers are made of seamless copper tubing and the coils are circuited for counter-flow heat transfer to provide the maximum mean effective temperature difference. The entire coil block is air pressure tested under warm water. The Finned Coil Heat Exchangers of the Adiabatic Ammonia Condensers consists of Grade TP304L stainless steel tubes and aluminum fins. Headers are made of stainless steel Grade TP304L tubes and the coils are circuited for counter-flow heat transfer to provide the maximum mean effective temperature difference. The headers have stainless steel flanged connections, as standard. The entire coil block is air pressure tested submerged in warm water. The Condenser Finned Coil Heat Exchangers are manufactured in strict accordance to the Quality System Manufacturer of the EU Directive for Pressure Equipment under the inspection of TÜV NORD. 12

STEEL SUPPORTING FRAME Structural elements and panel enclosure are constructed by using heavy gauge hot dip galvanised steel with an innovative metallic coating on both sides that offers protection in the harshest environments. The coating consists of a metallic chemical composition of zinc with aluminium and magnesium, which creates a stable and durable layer across the entire surface and gives a far more effective corrosion protection. AIR MOVEMENT ELECTRICAL & CONTROL PANELS The Air Movement Package combines premium aerodynamic and acoustic performance with innovative design to offer a compact fan and motor as an integrated product. It heralds a new era in fan design and technology, extending and setting new standards of innovation, performance and reliability. Increased electricity savings is achieved by the use of fan motors with permanent-magnet rotors, due to their higher efficiency. Motors with this technology are primarily known as EC motors. The fans selected are labeled as soft commutation. This involves a combination of commutation strategy and motor design. The result for the customer is low-noise operation, without structure-borne noise. With the fans selected there is no motor noise variation across the entire speed range. The advantage is that when demand for cooling is low, such as operation at night, very low operating speeds can be selected, resulting to extremely reduced absorbed power. Motor Electrical Details Phase Nominal voltage Nominal voltage range Frequency Motor protection Insulation Class Continuous running from Overall Efficiency Efficiency Grade N 3 400 VAC 380...480 VAC 50/60 Hz IP55 F 40oC to +60oC 51.0% [ required 2015: 37.1% ] 53.9 [ required 2015: N=40 ] The SPARTIUM Adiabatic Cooler is a plug-andplay machine complete with an Electrical Power panel section and an Electrical Control panel section, all fully wired. The complete electrical panel consists of an IP55 enclosure with a main magnetic power switch, an emergency cut-out switch, a circuit breaker for each fan and a 400V/230V/24V transformer with auxiliary fuses. The electrical Control panel section is supplied with 24V and includes: Its own Main Switch A microprocessor controller with display, wired to an ambient air sensor and to an immersion leaving temperature or pressure sensor A Pad Maintenance Switch Control Logic The fan speed is controlled on the basis of the actual fluid leaving temperature, or pressure, at the exit from the heat exchanger of the unit, and the design process fluid temperature, or pressure, ensuring minimum electrical consumption and noise level. The adiabatic pre-cooling will be activated and stopped on the basis of a preprogrammed logical combination of the fan speed and the ambient temperature. If water saving is the predominant objective, default settings will not activate adiabatic pre-cooling unless the fans are running at maximum permissible speed and the dry-to-adiabatic switch point has been reached. 13

Manufacturing Excellence SPARTIUM has achieved 50 years of manufacturing excellence in the HVAC industry by applying vertically integrated methods in manufacturing using latest Stateof-the-Art production machinery. It applies a strict Quality Management System as per EN ISO 9001:2008 in accordance with TÜV NORD CERT procedures, and applies a Quality System for Pressure Equipment Manufacturer according to the EU Directive, authorizing to affix the CE sign. 14

Dambassinas S.A. 272 Kifissias Ave., Chalandri, Athens, 15232, Greece Telephone: (+30) 210 6852 045 Fax: (+30) 210 6820 867 E-mail: info@spartiumcooler.com www.spartiumcooler.com AD/A/17