CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

Similar documents
ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

ACCREDITED. Product range Code A2L Modulating temperature regulating unit for heating and cooling, with ALPHA2 L pump.

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

Convertible radiator valve for one-pipe systems, centre distance 35 mm

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB.

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

Mercury Mixing Kit (Code: ME1053)

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc)

Dynamic thermostatic radiator valves DYNAMICAL

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA

caleffi hydronic valves page 1 of 12

Thermostatic mixing valves with replaceable cartridge for centralized systems

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Adjustable three-way thermostatic mixing valve... connections ½", ¾", 1" NPT male union and sweat union and ¾" press

function Adjustable thee-way thermostatic mixing valve... connections 1/2", 3/4", 1" NPT male union and sweat union

geothermal march 2011

PRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING

R557R EN January 2012

281 Series. ThermoBloc boiler protection recirculation and distribution unit. Installation, commissioning and servicing instructions

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

Systems for central heating

Composite under-boiler dirt separator with magnet DIRTMAG

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

anti-condensation valve

FHM-Cx Mixing Shunts for Floor Heating

Data Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application:

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Installation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems.

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

DISCALDIRT deaerator-dirt separator

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

Installation, commissioning and servicing instructions

DEVIATING VALVES ART K063

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

MIX2 - MIX3 MIX2 MIX3 COMPONENTS DESCRIPTION DIMENSIONS

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Wall-mounted compact indirect heat interface unit SATK30 series Safety instructions Dimensions Technical specifications Installation Commissioning

Thermostatic mixing valves with interchangeable cartridges

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

product overview ProControl

FHM-Cx Mixing Shunts for Floor Heating

Metering systems 0548EN April 2014

Technical Product Guide

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

HIGH EFFICIENCY CIRCULATORS. Represented by Taconova Group AG CATALOGUE 2018 EN. easyuse. greatperformance

Introduction. Application. Technical data

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

TS RD 7761 RD, 7761 RD

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Balancing & Control. Frese PV Compact. Differential Pressure Control Valve

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

R586R. Distribution and Regulation units. Datasheet 0861EN 04/2019 R586RY103 R586RY102 R586RY101 R586RY104

Contact person Date Reference Page Björn Folkeson P (14) Energy and bioeconomy

VST Series. INAIL approved and calibrated safety valves. Technical Data Sheet. WattsIndustries.com

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

CONTROL UNIT FOR UNDERFLOOR HEATING SYSTEMS

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

AquaKond Split. Caring for the environment! New Condensation Boilers. Efficiency up to 109% 4 Stars. AquaKond 70 kw Standard I.S.P.E.S.L.

Installation, operation and care Wall-mounted electric boiler MP THL nr. - rev 02

THERMOSTATIC MIXING VALVES FOR CONDENSATION PREVENTION

AVTI Multifunctional self - acting controller

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

Roth fixed-value control set with high-efficiency pump

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

Installation and Commissioning Instructions

Thermostatic Radiator Valves (Caleffi)

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

DIRTCAL - DIRTMAG dirt separator

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

Flush individual room control for floor heating systems

Trade Product List 2013 BIOMASS ACCESSORIES

Valves, controls + systems. Local and district heating technology. Innovation + Quality. Product range. for improved.

21 20 LITER GAS FRYER FFA3200 INSTALLATION AND SERVICING.

8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN.

Paddle Flow Switch. Pressure Control Flow Switch

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Section - A. Radiator Valves

CALEFFI DISCAL. deaerator-dirt separator DISCAL series ACCREDITED 01123/17 GB. replaces dp 01123/14 GB

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation

Series 759 FireLock Alarm Check Valve

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Transcription:

Set point thermostatic regulating unit 8 series FM 65 00 CALEFFI 090/8 GB replaces dp 090/5 GB Function The thermostatic regulating unit is made to be used in radiant panel systems, in combination with distribution manifolds. The set point regulating unit performs the function of keeping the flow temperature constant, at the set value, for the medium distributed in a low temperature system for floor radiant panels. In this particular series, the temperature is regulated by a specific hydraulic unit equipped with a thermostatic three-way valve with a built-in sensor. Reference documentation - Tech. broch. 06 Manifolds in composite material specifically designed for radiant panel systems 670 series Product range Code 85.AL Pre-assembled set point thermostatic regulating unit with manifolds and box, with UPM Auto L 5-70 pump Technical specifications Materials Regulating unit with three-way thermostatic radiator valve Body: brass EN 98 CB75S Headwork: brass EN 6 CW6N Obturator: PSU Seals: EPDM Flow adapter unit Body: brass EN 98 CB75S Performance Medium: water, glycol solutions Max. percentage of glycol: 0% Adjustment temperature range: 5 55 C Accuracy: ± C Primary inlet max. temperature: 90 C Maximum working pressure: 600 kpa (6 bar) Minimum working pressure: 80 kpa (0,8 bar) Panel manifold differential by-pass setting (optional, code 8000): 5 kpa (.500 mm w.g.) LCD digital thermometer scale: 8 C Pressure gauge scale: 0 0 bar Connections: - to regulating unit: / M (ISO 8-) with union - panel circuit outlets: / for coupling with adapter code 675850 - outlet centre distance: 50 mm - primary circuit connections centre distance: 60 mm Panel circuit differential by-pass graph Δp (mm w.g.) 5000 500 000 500 000 500 Δp (kpa) 50 5 0 5 0 5 000 0, 0, 5 0,5 0 0,5 0 Flow rate (l/min) (m /h)

con forme no r me ISPES L BATHROO M Safety thermostat Factory setting: 55 C ± C Protection class: IP 55 Contact rating: 0 A / 0 V Electrical connection diagram Unit pump ST Safety thermostat L 0 V N Room thermostat User side H (m w.g.) 7 UPM Auto L 5-70 (kpa) G (m /h) Note: The pump can operate with constant speed, constant pressure and proportional pressure control, which adapts the performance to the system requirements. For further details, see the installation instruction sheet of the pump supplied in the package. Dimensions 5 outlets 9 outlets outlets BATHROO M Head available at the regulating unit connections Tests carried out with constant speed control. Pump High-efficiency pump: model UPM Auto L 5-70 Body: cast iron GG 5/0 Electric supply: 0 V - 50 Hz Max. ambient humidity: 95% Max. ambient temperature: 70 C Protection class: IP Pump centre distance: 0 mm Pump connections: / F (ISO 8-) with nut Code Panel outlets

8 series Pmax0 bar r Tset 0 point 60 C Electric supply V bar 8 0 0 norme ISPESL CALEFFI Characteristic components BOILER FLOW Return manifold equipped with shut-off valves. BOILER SYSTEM ENTRATA C Flow manifold equipped with flow meters and balancing valves. Differential by-pass hose kit (optional, code 8000) SYSTEM FLOW C 6 ENTRANCE 6 c onforme CL.5 5 End fittings with automatic air vent and fill/drain cock.. Thermostatic three-way mixing valve with built-in sensor. High-efficiency pump UPM Auto L 5-70. Fitted for adjustable drain valve. Safety thermostat 5. Pressure gauge 6. Electrical wiring box Hydraulic diagram

CL.5 Operating principle The regulator element inside the thermostatic three-way valve consists of a temperature sensor () fully immersed in the mixed water outlet chamber. By expanding and contracting, it continuously ensures a correct proportioning of hot water, coming from the boiler, and water returning from the panel circuit. The water intake is regulated by a shaped obturator () that slides inside a special cylinder placed between the hot water flow () and the water returning from the circuit (). Even if the thermal load of the secondary circuit or the inlet temperature from the boiler changes, the mixing valve automatically adjusts the flow rates until it obtains the set temperature. PRIMARY INLET Construction details Regulating unit body The valve body, containing the temperature regulating device, is made out of a single casting with connections to the primary and secondary circuits. A specific internal channel carries the system return medium to the regulating valve, making it possible to build a compact unit that is easy to connect. Reduced head losses The three-way mixing valve is equipped with a special obturator that acts on calibrated water orifices. This ensures a high flow rate and a compact size, while maintaining accurate temperature control. PRIMARY SECONDARY Anti-seizing materials The materials used for the mixing valve construction eliminate potential seizing due to scale. All functional parts, such as the obturator, valve seats and guides, have been made using a special material with low friction coefficient, which ensures product performance over time. Low-inertia thermostatic sensor The temperature-sensitive element, the actuator of the threeway thermostatic valve, has low thermal inertia; in this way it can react quickly to changes in the conditions of inlet pressure and temperature, shortening the valve response time to the changes in thermal load. SECONDARY FLOW Flow unit The flow unit is made out of a single casting with the necessary ports to connect with the functional components such as the safety thermostat and the pressure gauge. Temperature adjustment and locking The control knob is used to adjust the temperature in a full turn (60 ) between min. and max. It also has a tamper-proof system for locking the temperature at the set value. 8 series Pmax0 bar Tset0 60 C Electric supply V 6 bar 0 0 8 c onforme norme ISPESL Adjustment locking Turn the knob onto the required number, unscrew the upper screw, remove the knob and put it back on so that the internal reference couples with the protrusion on the knob holder nut. Safety thermostat We recommend the safety thermostat is connected to the heat generator so that the electric supply is cut off when the triggering temperature is reached. To do so, connect the two safety thermostat wires directly to the generator and create an electrical jumper between the two contacts on the terminal board for unit 8, previously connected to the safety thermostat.

con f orm e no rm e I SP ES L Application diagrams Pump Variable speed pump Three-way valve Thermostatic radiator valve Lockshield valve Shut-off valve Clock Room thermostat Differential by-pass valve

SPECIFICATION SUMMARY 8 series Set point thermostatic regulating unit. Connections to the regulating unit / M (ISO 8-) with union. Panel circuit outlet connections / for coupling with adapter code 675850. Medium water and glycol solutions; max. percentage of glycol 0%. Regulating temperature range 5 55 C. Maximum temperature at primary circuit inlet 90 C. Maximum working pressure 600 kpa (6 bar). Minimum working pressure 80 kpa (0,8 bar). Panel manifold differential by-pass (optional, code 8000) setting 5 kpa. LCD thermometer scale 8 C. Pressure gauge scale 0 0 bar. Complete with: flow manifold for panel system with outlets (from to ) with PA66GF body, flow rate regulating valve with flow meter with a scale of l/min; return manifold for panel system with outlets (from to ) with PA66GF body, shut-off valve. Regulating unit with three-way thermostatic valve with brass body and headwork, PSU obturator and EPDM seals. Flow adapter unit with brass body. Electric supply 0 V - 50 Hz. Safety thermostat: factory setting 55 C ± C, protection class IP 55, contact rating 0 A / 0 V. Pump UPM Auto L 5-70, protection class IP. Supplied preassembled in painted sheet metal box. Closure with a push-fit clamp. Depth adjustable from 0 to 50 mm, including floor supports adjustable in height from 70 to 0 mm. We reserve the right to make changes and improvements to the products and related data in this publication, at any time and without prior notice. Caleffi S.p.A. S.R. 9 n. 5 800 Fontaneto d Agogna (NO) Italy Tel. +9 0 89 Fax +9 0 867 info@caleffi.com www.caleffi.com Copyright 08 Caleffi