MaxGard. Interconnection Systems. Durability. Performance. Safety

Similar documents
Heavy Industrial/Marine MaxGard

CS1000. Single Pole Plugs & Connectors up to 400A, 1000VAC Featuring: Silver-Nickel, Butt-Style Contacts. Locking Pin. Finger Guard (IP2X)

ULTRA-SAFE Explosion-proof Duct Heaters

FX5 Series Explosion-Proof Electric Air Heaters

PANELBOARD PROTECTION ON A GLOBAL SCALE

ULTRA-SAFE Explosion-proof Duct Heaters

Control and power circuit fusing to meet N.E.C.

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

Custom Duct Heaters. Special Applications

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

You work hard on your panel. we work hard in your panel. PRODUCTS FOR

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

2409/2900. Fire Guard

SIMPLEX WEATHERPROOF CONTROL PANELS

2408/2900. Fire Guard

SECTION HVAC Fans

Custom Duct Heaters. Special Applications

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved

TABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

EJB Custom-Built Control Panels

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

SUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS)

PowerWave 2 Busway System

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

VIII. Heaters Mobile Climate Control 121 MCC Reference Manual 2014

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

SIMPLIFIED LIGHTING. TRUSTED PROTECTION. CODE MASTER LED LUMINAIRES CLASS I, DIVISION 1

Centro-Matic Automated Lubrication Systems System Controls

ABH BASIN HEATER CONTROLS PACKAGE. engineering data and specifications

Description. Applications

SECTION ISOLATED POWER SYSTEMS

Model: FT110 Dishwasher

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards.

ULTRA-SAFE EXP. Applications E X P L O S I O N - P R O O F H E A T E R S

Special Provision No. 682S27 June This Special Provision refers to the following standards, specifications or publications:

Tubular Industrial Process

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4

Applications. Standard Materials

Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

Cold Deck FIT. Canopy and Shelf Lights and Retrofit Kit. Installation Guide for General Information. Tools and Accessories Recommended

EXH Series Explosionproof Electric Air Heaters

Explosion Proof Hazardous Location Roof Top A/C Units

Capacity: 1.5 to 6.0 Ton

Thermal Devices, Inc. Mount Airy, Maryland USA C D E F. Typical Maxiband Clamping

Installation Instructions Air Pump

Powers Controls Low Temperature Detection Thermostat

SECTION SANITARY SEWAGE PUMP STATIONS

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

DETCON MODEL AV1/AV2-C1D2M Hazardous Duty Class I. Div 2, Multitone Alarm Station

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.

I P. Tough Starters for Tough Environments. Explosion Proof Starter. Ready to Install, Completely Wired and Assembled

Introducing a revolutionary new line of 15 and 20 amp devices engineered for fast and easy installation

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

Introduction. Technical Features

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

EHT/EHTD. Electromechanical Closer-Holder Release Devices

CX1 ProVector Explosion-Proof Heaters

your dust explosion protection experts

PRODUCTS FOR Wiring Duct Power & Grounding Connectors Fastening Products Control Termination Identification Solutions

ASCO Series 185 Power Transfer Switches

Water Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Explosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps

SECTION EXTERIOR LIGHTING

Explosion Proof Push Button Momentary Switch - C1D1, C2D1 - Adjustable Timer - 10 sec-170 Minutes

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

Brasch Hazardous Location Unit Heaters

A99B Series Temperature Sensor

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B

Eldex Column Heater. Operator s Manual

PS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL

Pathway Lighting. Introduction

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Explosion Proof Exit Sign - Class I, Division I - IP65-120V/277VAC - Emergency Battery Back-Up

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

Explosion Protected Panelboards D2Z Series

Section COMMUNICATION EQUIPMENT ROOM FITTINGS. Section Communications Cabinets, Racks, Frames and Enclosures

POWER AND CONTROL PRODUCTS QUICK RESPONSE PROGRAM.

150W Explosion Proof LED Light - 5' Tall Base Stand Mount - 24" Stand - Class I Div 1 C&D V

Operator: Save these instructions for future use!

NJWEA TECH TRANSFER MARCH 1, 2016

EVLPF Series Compact Fluorescent

Capacity: 1.5 to 6.0 Ton

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

Transcription:

8Russellstoll Pin and Sleeve Power Connectors Safety Different power supply ratings can t mix: 24 single-rate device polarizations ensure exact voltage, frequency and phase differentiation Safe connections: Safely connect and disconnect, even in the most extreme conditions such as heavy industrial and explosion-proof environments Added safety measures: Explosion-proof rating on all plugs Plugs stay in: Standard delayedaction pull-and-turn withdrawal offers all plugs an explosion-proof rating Waterproof construction: Standard O-ringed interior components provide environmental separation; watertight mated or unmated Durability Built for durability: Rugged cast aluminum housings with an electrostatic epoxy coating are standard, along with stainless steel hardware The best connections for life: Pins and sleeves are made from Marine-grade CDA 485 brass; 200- and 400-amp pins and sleeves are silver plated Performance Foreign objects stay out: All receptacles and connectors have a gated rotating disk (gated deadfront) on the face of the interior, which engages upon insertion Any configuration you need: Through 4-pole 5-wire configurations, all have a safety center earth ground pin design that makes first and breaks last Ease of assembly: Solderless pressure-type screw terminals with hex socket heads and rear-access, take-apart housings provide quick wiring access no interior removal required for wiring receptacles and connectors More control available: Two optional pilot/control pins for contactors, load monitoring circuit, shunt trip or any other communication function you need More power: 150% non UL rating enables MaxGard installations to be extended up to 600-amp custom loads with separate disconnect service

Receptacles, Inlets, Plugs, Connectors, Interlocked Receptacles, Explosion-Proof Interlocked Receptacles Plug and Receptacle with Angle Adapter and Junction Box Electrostatic epoxy powder coat finish for maximum corrosion resistance Extra thick-wall back boxes 300 series stainless steel hardware for corrosion resistance (entire line) CDA 485 Marine-grade brass pins and sleeves Copper-free cast aluminum housings Neoprene O-rings on pins, sleeves and interiors provide environmental separation and true waterproof integrity Acme threads prevent freezing of screw collars and covers Compression-type gland bushing for optimal cable seal Center Ground Contacts: Make First, Break Last Optional Control/Pilot Contacts: Make Last, Break First Padlock-out access hole in plug shroud provided as standard safety feature Optional pilot contacts available for control or electrical interlocking Extra-long current contacts with deep-well arc containment Gated deadfront construction Delayed insertion/removal keyways provide explosion-proof approval for standard 30-, 60- and 100-amp plugs and receptacles. Hex-type pressure terminals to ensure tighter connections Available up to 4P5W + pilot; Circuit Interrupting/Load Breaking 30 to 200 amps. 9Russellstoll Pin and Sleeve Power Connectors

Receptacles, Inlets, Plugs, Connectors, Interlocked Receptacles, Explosion-Proof Interlocked Receptacles Cast Aluminum Circuit Breaker Interlocked Receptacle (Cutaway View) Thick-wall cast copper-free aluminum housing with epoxy powder coat finish Standard conduit openings through top or side (cutaway shown), optional sizes and locations Standard, high A/C or NA breaker switch (cutaway shown) Heavy On/Off handle adds mechanical-to-electrical interlock function Options include: Shunt Trip Auxiliary Switch Trip Ratings (External lockout option kit available) Gated, rotating deadfront receptacle Protective screw cap (flap cap also available) Watertight = Screw cap cover Splashproof = Flap cover Heavy-duty sliding bar interlock mechanism (mates with plug padlockout access hole) NEMA 4X interlocks avail able in 30 400-amp ranges through 4P5W, with 2 optional pilot/ control contacts. 10

Fused-Disconnect Switch* Interlocked Receptacle Available in 30-, 60- and 100-amp sizes, all polarizations through 600VAC. Standard 600V cartridge fuse clips and spacing Safety fuse pulls Clear shield for test probes Backup door safety latch Three external lockout points Door safety switch Heavy.060 steel galvaneel with baked enamel, NEMA 3R/12 construction Consult for additional options Fully interlocked MaxGard receptacle Meets Federal specification WS865C, UL File #E5239 Meets UL 98, 50, 1682, 508, 231 Meets NEC Table 373-6(b) Meets major automotive specs * Also available as switch only Angled front receptacle for easier access 11

MaxGard DBRE and DSRE series interlocks are explosion proof and waterproof (O-ring sealed), along with optional control contacts, and are fully UL Listed. Explosion-Proof Waterproof Circuit Breaker Interlocked Receptacle Available in 30-, 60- and 100-amp sizes, all polarizations. Heavy-duty cast aluminum housing, electrostatic epoxy coat finish Standard, high AIC and NA (switched only) breakers available Threaded access (cover not shown) with O-ring for explosion-proof and waterproof integrity Gated deadfront safety UL and CSA listed for hazardous locations Class I, Division 1, Groups B, C and D Class II, Division 1, Groups F and G UL File E10919 NEMA 7, 8, 9 CSA DOT shipboard used above deck green water NEMA 4X USCG approved Drain plug Factory-sealed receptacle interior accepts standard MaxGard plugs Explosion-Proof Waterproof Non-Interlocked Receptacle Available in 30A 480VAC max, all polarizations Factory-sealed interior (no filled conduits) Easy low-cost installation Threaded access (cover not shown) with O-ring for explosionproof and waterproof integrity Gated deadfront for safety Heavy-duty cast aluminum housing, electrostatic epoxy coat finish UL and CSA Listed for hazardous locations Class I, Division 1, C and D Class II, Division 1, Groups F and G UL File E10919 NEMA 7, 8, 9 CSA DOT shipboard used above deck green water NEMA 4X USCG approved All standard polarizations available to 480VAC Factory-sealed receptacle interior accepts standard MaxGard plugs 12