Metasys Integrator Compu-Aire Application

Similar documents
Metasys Integrator Vilter Application

Metasys Integrator TITUS Application

Metasys Integrator Airflow Application

Metasys Integrator Cleaver-Brooks Application

Metasys Integrator Liebert Application

Metasys Integrator McQuay Application

Metasys Integrator York Application

Reciprocating Chiller

Data Aire DAP TM III. Metasys Control Points

York 25-Ton VAV Rooftop Unit

Weekly Testing of Dedicated Stairwell Pressurization Fans- Metasys System Extended Architecture Code No. LIT

Fire System Objects. Introduction Page *3. Engineering *17. Data Base Generation *43

Fire Operator Workstation (Fire OWS) User s Guide

Weekly Testing of Dedicated Smoke Control Dampers - Metasys System Extended Architecture

FCD-wire Contents. List of Figures

DAP III Zone Master User s Guide

DX-9100/9120 Local Sonalert Logic

21-light Remote Annunciator. Owner s Manual

Metasys System Extended Architecture Smoke Control UL 864 UUKL Compliance

Instruction Manual Model Backup Switch, 1 for 8

DX-9100 Applications from Engineering Services

Metasys Integrator Carrier Application

P2267 NETWORK INTERFACE

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

TC-9102 Applications

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

ACT2-CS Convenience Store Controller

DX-9100/9120 Warehouse Smoke Exhaust and Reset Logic for a Rooftop Unit

Multistate Alarm. Introduction

DX-9100/9120 Weekly Testing of Dedicated Stairwell Pressurization Fans

RPM1600 Series Room Pressure Monitors

ModBus DE-1 INSTALLATION AND USER MANUAL

20 Light Remote Annunciator

IntesisBox BACnet/IP Server - Notifier ID3000 series

User manual. KNXpar. version

Products no longer available

MicroTech Unit Ventilator

Introduction. What is the W2W Open controller?

Johnson Controls Fan Coil Units and Direct Digital Controls

HRX Technical Manual. Version 1.2

TEC Networked Multi-Stage Economizer Thermostat

RS485 MODBUS Module 8AI

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

Simplex Panel Interface Guide

Model A1700 Series Annunciator

Contents. Appendix E: LonWorks Protocol Implementation Conformance Statement Document revision history... 47

TEC Networked Multi-Stage Thermostat

User manual. KNXgal. version

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Installation Guide Bacharach Communications Adapter HGM-MZ to Johnson Controls Metasys N2 Network (Electrically Isolated N2 Port Version)

FieldServer FS Secutron

Single Story Enclosed Shopping Mall Smoke Control with FSCS Override - Metasys System Extended Architecture

Manual Supplement. Model Number: 8680-N2. Communications Protocol. Contents of this manual supplement include:

OVEN INDUSTRIES, INC.

ICC INDUSTRIAL CONTROL COMMUNICATIONS, INC.

Laptop / PC Programming Manual

OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement

Roo232 User Guide. Revision 1.0. Copyright 2006 RoboDynamics Corp

I/O ZONE 560/583 USERS GUIDE

Table of Contents. WSHP Open v3

SETTING UP A VIRTUAL KEYPAD WITH A DSC POWERSERIES ALARM SYSTEM

ME 3011C / Alarm Indication / Quick Reference Guide

Compu-Aire System 2200 xs Programmable Controller

TEC2100 Series Networked Thermostats

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

CLEANROOM MONITOR CR3A Network - Installation Instructions

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

Data Aire DAP TM III. LonWorks Protocol Integration Information

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X

TEC210x-2 Series Networked Thermostats

FS Mircom FX2000 Fire Alarm Panel

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

FST DFS Notifier Onyx 640

MicroTech Self-Contained Air Conditioning System

EXD-HP1/2 Stand-alone Superheat/Economizer Controller

R -OFF- 11. Remote control Setup for remote control. S xxxx I xxxx

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

DTSX200 Communications(Modbus) Guide

Data Aire DAP TM III. LonWorks Protocol Integration Information

AIS750 Series Alarm Annunciator

Carbon Monoxide Transmitter

AKSolutions Data Sheet April 2007 AK882X RF POWER MONITOR. Description: Features:

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

Installation & Maintenance

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

UNT Applications. Using UNT Applications...3. Introduction Key Concepts UNT Controller Applications Fan Coil Units...

DGC-1000 DIGITAL GENSET CONTROLLER

mti085 Temperature Interface

READ AND SAVE THESE INSTRUCTIONS

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

MicroTech Series 200 Centrifugal Chiller

VersAlarm. Installation & Operation Manual

Lift Station Level Controller

TEC Networked Single-Stage Thermostat

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Lennox Climatic 50 and BMS Modbus, Trend or BACnet.

TEC1100 Series Thermostat

Transcription:

Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date 0496 APPLICATION NOTE Metasys Integrator Compu-Aire Application lntroduction Page 3 Application Details 3 Component Requirements *5 Vendor Contact Information *5 Design Considerations *6 Cable Connections 7 Cable Pinouts 7 Connecting the Cable 8 Metasys Integrator Setup 9 Point Mapping Table 11 Metasys Network Setup 13 Mapping to a CS Object 13 * Indicates those sections where changes have occurred since the last printing. 1996 Johnson Controls, Inc. 1 Code No. LIT-6295230

2 Metasys Integrator Metasys Integrator Compu-Aire Application

lntroduction This document explains the Metasys Integrator Compu-Aire application. Use this document with the Metasys Integrator Technical Bulletin (FAN 629.5), which provides information on installing and commissioning Metasys Integrator. For information on vendor equipment, see Compu- Aire documentation (obtainable from Compu-Aire representative). Application Details Metasys Integrator allows Compu-Aire equipment to become an integral part of the Metasys and Metasys Companion Networks. Once Compu-Aire System 2100s are connected to a Metasys or Companion Network via the Metasys Integrator, their data is available to the full complement of Metasys Facility Management System (FMS) features, including Change-of-State (COS) monitoring, alarm notification, scheduling, trend, and totalization. The System 2100 connects to one of Metasys Integrator vendor ports. Each Metasys Integrator vendor port can connect to one Compu-Aire System 2100, which allows access to the entire Compu-Aire network. There can be up to 63 units on the Compu-Aire network. Figure 1 shows Compu-Aire and Metasys integration, and Figure 2 shows integration with a Metasys Companion Network. Metasys Integrator Metasys Integrator Compu-Aire Application 3

N1LAN Standard NCU RS-232 S ystem 2100 RS-232 RS-232 RS-232 System System 2100 2100 Metasys Integrator UNT N2 Bus compu1 Figure 1: Compu-Aire System 2100s and Metasys Integration PC-Version Panel Version/LTD or Converter Metasys Integrator RS-232 System 2100 RS-232 System 2100 RS-232 System 2100 UNT N2 Bus cmpucomp Figure 2: Compu-Aire System 2100s and Metasys Companion Integration 4 Metasys Integrator Metasys Integrator Compu-Aire Application

Component Requirements Metasys Release Requirements Metasys Companion Release Requirements Vendor Component Requirements Vendor Contact Information To integrate Compu-Aire System 2100s, you ll need the following: properly installed Compu-Aire 2100s RS-232 cable (for connecting the System 2100 to Metasys Integrator) Metasys Integrator N2 Bus (for connecting Metasys Integrator to the Metasys or Companion Network) portable PC for downloading vendor communication tables (.VCT files) and network setup information, and for running diagnostics cable for connecting portable PC to Metasys Integrator the correct vendor communication table (.VCT file) to download into Metasys Integrator (supplied on diskette) This document describes the RS-232 cable and the vendor communication tables. Compu-Aire documentation describes their equipment. The remaining components are described in the Metasys Integrator Technical Bulletin. To integrate Compu-Aire equipment into the Metasys Network, you ll need: Metasys OWS software Release 6.0 or higher Metasys Integrator software/firmware 5.0 or higher To integrate Compu-Aire equipment into the Metasys Companion Network, you ll need: Metasys Companion Release 5.0 or higher Metasys Integrator software/firmware 5.0 or higher Integration between Metasys Integrator and Compu-Aire has been tested with the Compu-Aire System 2100, version V2.0P for low resolution, and version V2.0PF for high resolution. Changes to this equipment or integration of Compu-Aire products not discussed in this document will require additional software development and testing by Systems Products. For information on integrating other products, call Engineering Services in Milwaukee (extension 4357). Compu-Aire, Inc. 8167 Byron Rd. Whittier, CA 90606 Phone: (310) 945-8971 FAX: (310) 696-0724 Metasys Integrator Metasys Integrator Compu-Aire Application 5

Design Considerations When integrating Compu-Aire and Metasys, consider the following: Make sure Compu-Aire equipment is set up and running properly before integrating with Metasys or Companion Network. (The Compu-Aire representative is responsible for operation of Compu-Aire equipment.) Determine whether you are using the System 2100 in standard or enhanced high resolution mode. If you are using the enhanced mode, make sure you download the CA_210E.VCT file. Otherwise, use the CA_2100.VCT file. Make sure the System 2100 baud rate is set to 300. (The Compu-Aire representative is responsible for setting the System 2100 baud rate.) RS-232 cable distance between Metasys Integrator and the System 2100 can be a maximum of 50 feet. Anytime the operator attempts to modify parameters from the front panel of any System 2100 controller, that controller will go offline. It will return to online when front panel malfunctions are complete. 6 Metasys Integrator Metasys Integrator Compu-Aire Application

Cable Connections Cable Pinouts Use the following cable pinouts for the RS-232 connection between Metasys Integrator and the System 2100. Unit 1 Shield Comm on Signal Common RX from Slave From Integrator TX To Integrator RX TX to Slave 1- Shield 2- GND 3- Output 4- Input 5- Input 6- Output Vendor Port A or B on Metasys Integrator DB-9 Female Signal Pin RD 2 TD 3 GND 5 Unit 2 Shield Common Signal Common RX from Slave RX from Host TX to Host TX to Slave 1- Shield 2- GND 3- Output 4- Input 5- Input 6- Output To Next Unit compu2 Figure 3: Cable Pinouts Metasys Integrator Metasys Integrator Compu-Aire Application 7

Connecting the Cable Connect the female end of the RS-232 cable to either Vendor Port A or Vendor Port B on Metasys Integrator. Connect the other end to the RS-232 Serial Port terminal screws on the System 2100 Communication Card. Metasys Integrator System 2100 Communication Card Vendor Port A or B RS-232 Cable 11 10 4 RS-232 Terminal Block compu3 Figure 4: Port to Port Connection 8 Metasys Integrator Metasys Integrator Compu-Aire Application

Metasys Integrator Setup To set up Metasys Integrator, you ll use a portable PC connected to the Metasys Integrator Terminal Port. Metasys Integrator setup involves: downloading the correct vendor communication table (.VCT file) setting up the ports setting up the network addressing The following table provides information specific to the Compu-Aire application. For detailed procedures, see the Metasys Integrator Technical Bulletin. Table 1: Metasys Integrator Setup for Compu-Aire System 2100 Vendor Communication Table (.VCT File) Compu-Aire 2100 CA_S2100.VCT Compu-Aire 2100 Enhanced CA_S210E.VCT Port Setup Baud Rate 300 Word Length 8 Stop Bits 1 Parity Interface Network Setup Vendor Address Timeout Value Poll Delay Performance Guide Approximate Scan Time (For a single N2 address) Compu-Aire 2100 None RS-232 01 to 63 (two digits required) 10000 ms The timeout value varies for System 2100 networks. You may need to increase the timeout value if a large number of units are connected to the network. 550 ms 6 seconds Metasys Integrator Metasys Integrator Compu-Aire Application 9

10 Metasys Integrator Metasys Integrator Compu-Aire Application

Point Mapping Table The following table shows the points available for mapping in the Compu-Aire System 2100. This table can be used with either.vct file. To get the hardware reference for mapping points to a CS object (via the software model), combine the NPT (Network Point Type) and NPA (Network Point Address). For example, the hardware reference for the Temperature point, the hardware reference is AI1. Table 2: Compu-Aire System 2100 Points NPT 1 NPA 2 Unit Description AI AI AI AI 1 2 3 4 DegF %RH DegF %RH Temperature Humidity Temperature Deadband (01-05) Humidity Deadband (02-10) BI 1 Fire Detector 0-ok, 1-alarm 3 BI 2 Smoke Detector 0-ok, 1-alarm 3 BI 3 Water On Floor 0-ok, 1-alarm BI 4 Air Flow 0-ok, 1-alarm BI 5 Water Flow 0-ok, 1-alarm BI 6 Power Interrupt 0-ok, 1-alarm BI 7 Change Filter 0-ok, 1-alarm BI 8 Fan Motor Overload 0-ok, 1-alarm BI 9 Humidifier Fail 0-ok, 1-alarm BI 10 Room Over Temperature 0-ok, 1-alarm BI 11 Room Under Temperature 0-ok, 1-alarm BI 12 Room Over Humidity 0-ok, 1-alarm BI 13 Room Under Humidity 0-ok, 1-alarm BI 14 Humidify 0-off, 1-on BI 15 De-Humidify 0-off, 1-on BI 16 Economy Cooling 0-off, 1-on AO AO 1 2 DegF %RH Temperature Setpoint (60-80) Humidity Setpoint (40-60) BO 1 Silence Horn 0-n/a 1-Yes 4 1 Network Point Type 2 Network Point Address 3 Fire/Smoke detectors mapped from the Compu-Aire System 2100 are not intended to meet the requirements of UL 864 or NFPA 72. Smoke detectors installed in Compu-Aire System 2100s required to meet the NFPA 90A, NFPA 101, or other local codes must be connected to an approved protective signaling system serving the building. Please refer to NFPA 90A Chapter 4 for further information. 4 Alarms can only be silenced. They must be corrected at the unit and cleared by a power down reset. Continued on next page... Metasys Integrator Metasys Integrator Compu-Aire Application 11

NPT 1 (Cont.) NPA 2 Unit Description BD 1 BD 2 BD 3 BD 4 BD 5 BD 6 BD 7 BD 8 BD 9 BD 10 BD 11 BD 12 BD 13 BD 14 BD 15 BD 16 BD 17 BD 18 BD 19 BD 20 BD 21 BD 22 BD 23 1 Network Point Type 2 Network Point Address Compressor 1 LP Fail 0-ok, 1-alarm Compressor 1 HP Fail 0-ok, 1-alarm Compressor 1 OL Fail 0-ok, 1-alarm Compressor 2 LP Fail 0-ok, 1-alarm Compressor 2 HP Fail 0-ok, 1-alarm Compressor 2 OL Fail 0-ok, 1-alarm Heater 1 Fail 0-ok, 1-alarm Heater 2 Fail 0-ok, 1-alarm Heater 3 Fail 0-ok, 1-alarm Heater 4 Fail 0-ok, 1-alarm Heat Stage 1 0-off, 1-on Heat Stage 2 0-off, 1-on Heat Stage 3 0-off, 1-on Heat Stage 4 0-off, 1-on Cool Stage 1 0-off, 1-on Cool Stage 2 0-off, 1-on Cool Stage 3 0-off, 1-on Cool Stage 4 0-off, 1-on Dehumidify Stage 1 0-off, 1-on Dehumidify Stage 2 0-off, 1-on CW Cooling 0-off, 1-on HW Heating 0-off, 1-on Humidify Flush Cycle 0-off, 1-on 12 Metasys Integrator Metasys Integrator Compu-Aire Application

Metasys Network Setup Metasys Network Setup is described in the Metasys Integrator Technical Bulletin. This section contains details specific to Compu-Aire applications. Mapping to a CS Object Table 3: Software Model and CS Object Details Application Software Model (on models diskette) Display Attribute (recommended) System 2100 CA_S2100.DDL AI1 Temperature NT Command Attribute (recommended) BO1 Silence Horn Metasys Integrator Metasys Integrator Compu-Aire Application 13

Notes 14 Metasys Integrator Metasys Integrator Compu-Aire Application

Notes Metasys Integrator Metasys Integrator Compu-Aire Application 15

Notes Controls Group FAN 629.5 507 E. Michigan Street Metasys Connectivity Technical Manual P.O. Box 423 Metasys Integrator Release 6.0 Milwaukee, WI 53201 Printed in U.S.A. 16 Metasys Integrator Metasys Integrator Compu-Aire Application