Who we are? Spanish fire alarm systems manufacturer. Engineering team with more than 20 years of experience in the fire detection field. Own design 100% local components Own fabrication Total quality control Wharehouse in Spain 4
Chronology Founded in 2007 with the participation of the Circutor Group. In 2009 we launched the conventional and CO detection product range, in 2012 we launched the addressable product range and the extinguishing control panel in 2014. Until the end November 2014 we are selling in Spain the poducts under the brand Circontrol. Detnov brand for the export markets with customers in more than 25 countries. By the end November 2014 we become part of an european group of fire detection manufacturers. 5
European Group Finsécur (Francia): Top fire detection manufacturer in France (NF) TheFireBeam (UK): Fire beam detector manufacturer. Detnov (España): EN54 fire alarm systems manufacturer 6
Our facilities Headquarters in Sant Boi del Llobregat ( Barcelona) Branch office in Madrid
Product Range Conventional Addressable CO detection Extinguishing
Benefits of our systems Nice design Easy manufacturing and commisioning European Approvals, Dubai Civil Defense approved, etc. Same design for all the product range Competitive price 9
Our references Hotel / Residential Industrial Commercial Universities Banks Sports 10
Our references Hotel & Spa Golden Bahía (Girona) Hotel Best Western (Tarragona) Premium Business Center(Lithuania) Police Station Brcko (Bosnia) Mango Logistic Center (Barcelona) Europastry (Barcelona) Aurum Club Marmara (Turkey) Boboli Headquarters (Barcelona) Vlatacom R&D Center (Serbia) IQS University (Barcelona) Azel Kule Apartments (Turkey) Ikea Parking(Valencia) Bahaus Parking (Mallorca) 11
Associations and Exhibitions We belong to the following associations: We have stand in the most important fairs in our field: 12
Addressable system 13
Loop Power 250 addresses per loop, without any limitation for the connexion of any type of device into the loop Non polarity* Conventional and Extinguishing panels connected into the loop Sounder capacity (max. 50 in loop) 2Kms loop lenght 250 zones per control panel *For devices without isolator 14
Addressable Control Panels Models CAD-150-1 Mini: 1 loop (100 addresses) CAD-150-1: 1 loop (250 addresses) CAD-150-2: 2 loops (250 addresses x loop) CAD-150-4: 4 loops (250 addresses x loop) CAD-150-8: 4 loops expandable up to 8 (250 x loop) CAD-150-8 Plus: with big box 15
Addressable Control Panels Features 2 supervised sounder Output Alarm and fault relay output USB port for configuration and commissioning Easy to use Event programmation Configuration software user friendly 16
Addressable Control Panels Features Auto-search function Auto-check function Double address detection Day and night configuration Up to 4.000 events log register split in different parts: General 4096 events Alarms 512 events Faults 1024 events Commissioning 512 events 17
Addressable Control Panels Connectivity TRED-150: RS485 board TFID-150: Fiber optic board 32 control panels network Bus or rail configuration 1 Km within control panels 18
Modbus integration RS485 communication output BMS integration Integration with other security systems Communication protocol 100% open 19
ARC communication Alarm signal transmision Contact ID standard protocol Integration with most of the ARC Communication types* Telephone line GPRS Ethernet *depending on the model 20
Addressable detectors DOD-220A: Optical smoke detector DTD-210A: Heat detector (58ºC/8ºC min.) DTD-215A: High heat detector (78ºC) DOTD-230A: Smoke and heat detector Elegant design Same connection base Z-200 and high base STD-200 for all the systems 2 wire connection without polarity With or Without built in isolator 21
Addressable detectors Dirtiness compensation Avoids False alarms Buzzer for addressable detectors BUD-200 Evacuation warnings Leds blinking configuration 22
Addressable Modules Features Full range DIN rail installation Red Colour With or without isolator Safe box for modules Connections through removable terminal blocks 23
Addressable Modules Inputs / Outputs MAD-401: 1 technical input MAD-402: 2 technical inputs MAD-411: 1 free relay module MAD-412: 2 free relay module MAD-421: 1 input / 1 output module MAD-422: 2 inputs / 2 outputs module MAD-481: 230VAC free contact relay module Configurable NO & NC Input without supervision line With or without built-in isolator Module takes addresses depending on its number of inputs and outputs 24
Addressable Modules 24V Output/sounders MAD-431: 1 supervised output MAD-432: 2 supervised outputs 24V 25
Addressable Modules Conventional Zone MAD-441: 1 conventional zone MAD-442: 2 conventional zones 24Vcc 26
Addressable Modules Isolator No address Recommended every 32 devices Polarity 27
Addressable call points and sounders Manual call point MAD-450 without isolator MAD-450-I built-in isolator Addressable sounders MAD-464-I sounder MAD-465-I sounder beacon Maximum sounders per loop: 1Km up to 50 sounders 2Kms up to 25 sounders 28
Programming tool Address Programmer PGD-200 Addresses all the loop devices (detectors/mcp/modules/sounders) Long battery life Functions/Programs Manual addressing / automatically Device address / analogue value 29
Configuration software Intuitive and user friendly (Windows) Copy and paste Logical maneuvers programmation Download free in our website 30
Engineering software Commissioning and maintenance tool. Detectors dirtiness display Detectors behaviour graphical display Communications check Devices verification (type, address, etc.) Control panel activation maneouvers 31
Graphical software Configuration systems Real time monitoring Reports Graphic creation Multi-user Different users with access levels Remote supervision Customization Competitive price 32
Conventional systems 33
Conventional control panels Full range: 2 up to 12 zones CCD-102 / CCD-104 / CCD-108 / CCD-112 Easy installation (ABS plastic case) 32 devices per zone Differentiation between the mcp and detector alarm Test mode per zone No polarity Connection into the addressable loop PC programmable 34
Conventional detectors DOD-220: Smoke detectors DTD-210: Heat detector DTD-215: High heat detector DOTD-230: Smoke and heat detector Elegant design Same connection base Z-200 and high base STD-200 for all the systems Available in black 35
Non polarity instalation Correct wiring Wrong wiring 36
Connection zones 32 devices per zone Differentiation between the mcp and detector alarm 37
Connection example RELAY OUTPUT ALARM & FAULT EOL R. 4K7 OUTDOOR SOUNDER OUTPUT EOL R. 4K7 EOL R. 4K7 EOL R. 4K7 CONFIGURABLE EXTERNAL INPUT 24V RESETTEABLE OUTPUT 24V AUXILIARY OUTPUT SOUNDERS DELAY 38
Expansion modules TRD-100: 4 Free Contact Relay Output Expansion Card TSD-100: 4 Supervised Voltage Outputs 39
Addressable Gateway TPLD-100 Allows the integration of the conventional control panels into the addressable loop. Cost effective solution for the conventional and addressable system 40
Programmation software Free software for complex configurations USB connection cable (CCC-100) Alarm or fault programmation 41
Modbus Communication Card Expansion Card TMD-100 RS485 network output Integration with BMS Integration with other security systems Management and control in zone level Communications protocol 100% open 42
ARC communication Alarm signal transmision Contact ID standard protocol Integration with most of the ARC Communication types* Telephone line GPRS Ethernet *depending on the model 43
Extinguishing control panel 44
Central de extinción CCD-103 3 detection zones and one extinction risk Certified EN12094/1, EN54-2 y EN54-4 One output for the activation of the bottle and one for the warning sign activation. 2 inputs for the bottle surveillance: pressure and one for the flow Working modes for the extinction block: Manual, automatic and y aborto. Two sounder outputs for the indication of the extinguishing states.: Pre-activated y activated. Configurable extinguishing delay on board. Two inputs for the area s surveillance: one for the door and one for the fan. Event and configuration history register. Three MCP inputs: start, stop and hold. Optional communication card that allows the integration in an Analog loop. Configuration Software. 45
Ejemplo de conexionado 46
Addressable Gateway TPLD-100 Allows the integration of the conventional control panels into the addressable loop. Cost effective solution for the conventional and addressable system 47
Programmation software Configuration of different options Events log register 48
Special detectos 49
Beam Detectors Motorized beam detectors DBD-DL40: 40 up to 100 meters* Controller and detector are separated Emitter and receiver in the same box Self configuration and alignment Avoid false alarms IP65 *Expandable kits up to 100 meters High humidity environments Easy commisioning 50
Stand- Alone detectors Domestic use Certified CPR EN15604:2005 + AC 2008 (domestic use) Battery life (1 / 5 / 10 years) Sounder and battery inside Calypso Serenity Calypso-R 51
Monoxide detection 52
Monoxide control panels Expandable up to 3 zones 32 detectors per zone 2 wires without polarity 2 kms cable lenght Different programmation: Instantaneous / Media Battery use 24V and 24V Aux (Optional) 53
Monoxide control panels Expandable up to 3 zones 32 detectors per zone 2 wires without polarity 2 kms cable lenght Different programmation: Instantaneous / Media Battery use 24V and 24V Aux (Optional) 54
Detectores de monóxido Célula electroquímica para mayor precisión Respuesta inferior a 10 segundos 5 años de vida útil Anti vandálico IP65 Estándar DMD-500 Compacto DMDP-500 55
Connection example Bus connection Star connection 56
Ventilation control modules Communications modules TRMD-500 y TRMD-501 Module with analogue outputs that allows to control the funs using speed regulators ( Energy Efficency) 57
Ventilation control modules Inverter 1 Extractor 1 Scada Software gestión CENTRAL CO Inverter 2 Extractor 2 58