HotFlashing. HotFlashing TM

Similar documents
HotValley TM

HotEdge Rail TM

HotEdge Rail TM

INSTALLATIONGUIDE. HotSeam TM Overview ICE ROOF

The IceFree Eave System

Edge Melt Systems. Roof Ice Prevention Perfected Product Catalog. PO Box Delafield WI Version 2.

The Technology Leader. Deicing Systems Catalog PO Box Delafield, WI

Roof and Gutter De-Icing

The Roof Ice Prevention Leader. Deicing Systems Catalog PO Box Delafield, WI

ROOF AND GUTTER DE-ICING ICESTOP SYSTEM

Gardian W51. Approvals

ROOF ICE MELT (RIM2) SYSTEM

ROOF ICE MELT (RIM) SYSTEM

IceStop System Installation and Operation Manual

IceStop System INSTALLATION AND OPERATION MANUAL FOR ROOF AND GUTTER DE-ICING SYSTEMS

Operating Guidelines for Your Roof and Gutter Ice Dam Prevention System

SECTION RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES

EN RaychemRIM2StandardInstallationManual IM H /16 1

Principle of Operation:

Self-regulating Roof Heat Cable

Toll Free:

Self-regulating Roof Heat and Gutter Trace Cable

Venmar Ventilation inc. is North America s most important manufacturer of residential air quality equipment.

RX1200 ROOF AND GUTTER DE-ICING CONTROLLER INSTALLATION AND OPERATION MANUAL

ALUMINUM. ELEVATED. CEDAR RENDITIONS DESIGN SERIES INSTALLATION INSTRUCTIONS

Installation Instructions

CertainTeed. Designer Shingles. Shown in Max Def Moire Black

Radiant Edge LT TM Ice Melt System Installation and Operation Guide Version 1.4

CertainTeed. Luxury Shingles. Shown in Georgian Brick

SMPG3 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL. For three-phase heating cables PRODUCT OVERVIEW

CertainTeed. Designer and Luxury Shingles. Shown in Landmark Pro Max Def Weathered Wood

CMHC HOME MAINTENANCE CHECKLIST

CertainTeed. Designer Shingles. Shown in Max Def Weathered Wood

CertainTeed. S ymphony. Slate Series. Give Your Home a. Standing Ovation

Installation Guide Soil, Asphalt & Concrete De-icing Heating Ribbons

DECORATIVE ELEMENTS OPTIONS. Add a little flare to your glass structure.

CertainTeed. S ymphony. Slate Series. Give Your Home a. Standing Ovation

INSTALL & USERS GUIDE

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

READ AND SAVE THESE INSTRUCTIONS

COMMERCIAL & RESIDENTIAL SELF-REGULATING HEATING PRODUCTS APPLICATION AND DESIGN GUIDE EUROPE, MIDDLE EAST, AFRICA

ADDITIONAL INFORMATION

Cer tainteed. Luxur y Shingles. Shown in Brownstone

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

CertainTeed. Luxury Shingles. Shown in Smokey Quartz

SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES PRODUCT OVERVIEW

Introduction. A Window A Room A Lifestyle! Shutter Collections. Your Personal Design Statement Begins with Mirasol Shutters.

Sunshine Manufactured Structures, Inc.

Considering a. Shed or a Garage?

Home Maintenance Schedule

While most maintenance is seasonal, there are some things you should do on a frequent basis year-round:

Sub-Zero offers two distinctive different models with

WOOD REPLACEMENT GUTTER

NEW NEW. CertainTeed. Designer Shingles. Warranties. Shown in Max Def Weathered Wood

CertainTeed. Designer and Luxury Shingles. Shown in Landmark Pro Max Def Weathered Wood

ce Is the Key Seasonal Home Maintenance Inspecting help keep live. help you. person to round: snow or debris. test button, which should then cause the

Vinyl Sliding Patio Doors

Polymer solutions Heating mat EM2-CM

MODEL GF PRO AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

H908 WinterGard Plug-in Power Connection Kit with End Seal

TS0 Series Portable Bulb and Capillary

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

INSTALLATION INSTRUCTIONS

Lansing Building Products offers the most comprehensive gutter program in the industry. Gutter Coil Accessories Gutter Machines Gutter Guard Systems

Aluminum Blinds. Aluminum Blinds. Dimensional Guidelines

Cottages. Construction Specs. Our Quality Sheds SKID LAYOUT

Installation Guide Maibec Regular Siding

ACR Solar International Corp Gibbons Dr. Suite H Carmichael, CA (916) "Islander" Installation Manual

CertainTeed. FiberCement Siding

SCREW PLUG IMMERSION HEATERS

PLSRR Heat Trace Cable Data Sheet

CertainTeed. Designer Shingles. Shown in Max Def Weathered Wood

Contents ATTACHING CONTROLS WARRANTY TOOLS... 5 ELEMENT ELEMENT POWER SUPPLY COVER HEATING ELEMENTS...

100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4

Commercial and Residential Self-Regulating Heating Products

MODEL CF CEILING SUPPORTED CHIMNEY

PRODUCT CATALOG. GUTTER SUPPLIES Residential and Commercial. Largest Selection, Competitive Pricing, Highest Quality and Unmatched Customer Service

Builder s Technical Sessions. Attic Ventilation. Presented by: Rob Kaethler. Presented in Partnership with: Insert your logo here

OFF-RIDGE VENTILATION PRODUCT BROCHURE

SEASONAL MAINTENANCE SCHEDULE

COMMERCIAL & RESIDENTIAL MARKETS U.S. ELECTRICAL

INSTALLATION INSTRUCTIONS

The CertainTeed Selects Advantage

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

The Monterey (PENNINSULA) MODEL PN36 3-SIDED, WOOD-BURNING FIREPLACE

CertainTeed. Designer Shingles. Shown in Max Def Weathered Wood

One of the most popular units within the inventory

CWA4 Chilled & Hot Water Fan Coil

SECTION ELECTRIC FLOOR HEATING AND SNOW MELTING EQUIPMENT

Solar Powered Roof Ventilation Fan

The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

ROOF DRAINAGE SYSTEMS

C e r t a i n Te e d D e s i g n e r S h i n g l e s

CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated)

Snow melting for ramps, access ways, and footpaths

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

STORM COLLAR 3/4" AIR SPACE BACK AND SIDES 31 5 / / /16 LOUVERS ON MODEL 3601 ONLY AIR KIT K/O GAS LINE K/O OUTSIDE AIR (LEFT SIDE ONLY)

Documentation. Parallel Heating Cable. Type: ELP

DS-8C RAIN/SNOW SENSOR CONTROLLER INSTALLATION INSTRUCTIONS

Transcription:

HotFlashing HotFlashing 800.411.3296 26 26

for HotFlashing for HotFlashing HotFlashing is a special engineered design used to prevent ice dam formations where roof walls meet roof slopes utilizing a commercial-grade 12W self-regulating UL-approved roof and gutter deicing heat cable. Since roof to wall or wall to roof can be problematic areas on many roof structures in medium and high snow load regions. A specially designed three sided angulated raceway securely holds a secure a single commercial grade self regulating heat trace cable in place for a direct heat transfer to prevent ice build-up along wall/roof areas on all roof structures. EXCLUSIVE FEATURES SECURE: An engineered channel was developed to receive existing composite asphalt shingles SIMPLE & FAST INSTALLATION: Simple design installs easily on all EXISTING asphalt composite shingle roofs NEC Compliant: The engineered open raceway design conforms to the NEC (National Electrical Code) Article 426 and provides access for insertion, inspection and replacement NO MODIFICATIONS: This one piece design requires no shingle cutting or removal. Avoids damaging or modifying existing roof shingles which saves time on installations to reduce overall cost of project LESS HEAT TRACE CABLE NEEDED: The benefit of a direct heat transfer is less heat trace cable is needed to prevent ice dam and icicles formations on all roof edges A GREEN SOLUTION: Less heat trace cable means lower energy costs. In fact, all HotEdge roof edge melt systems use at least 50% less heat trace cable than all other alternatives, i.e. zig zag and aluminum metal tracks WARRANTY: Industry leading 10-year limited warranty against heat cable failures and manufacture defects assures a long service. Heat trace cable is protected from UV light and snow/ice shifts and slides COLOR MATCH: Our expansive inventory and nationwide network allows HotEdge to best match existing roof or trim color 800.411.3296 27 27

for HotFlashing for HotFlashing SPECIFICATIONS MATERIAL SELECTION:.021 Copper, 24 gauge Kynar 500 Steel or.032 Aluminum Kynar 500 COLOR: Our expansive inventory and nationwide network allows HotEdge to best match existing roof or trim color DIMENSIONS: 5 lengths and commercial grade adhesive included HEATING SYSTEM: Commercial-grade 12-watt/ft self-regulating heat cable, ULapproved for roof and gutter deicing COMPONENTS: HotFlashing, commercial-grade 12W self-regulating UL-approved for roof and gutter deicing heat cable, commercial grade adhesive ELECTRICAL REQUIREMENTS: 120VAC, or 208-277VAC. NEC Article 426.28 requires 30mA ground fault circuit protection for roof ice melting systems 800.411.3296 28 28

DESIGN GUIDE for HotFlashing for HotFlashing Heat cable Partial exposure of heat cable for insertion, inspection or replacement Complies with NEC Article 426 Bottom is secured to roof surface with commercial grade adhesive to avoid penetration. HotFlashing Part of the HotEdge Roof Ice Melt System HotFlashing holds a single run of UL Listed self-regulating heat cable and spreads the heat up to 6 to 8 across the HotFlashing panel. Compared to a single run of exposed heat cable, the HotFlashing panel creates a much wider heated drain path that prevents ice melt water from refreezing until it can be drained away from the structure s foundation. HotFlashing can be used in the valley between roofs or next to the vertical walls of dormers. It protects and hides the heat cable and is available in a number of different colors to match the architectural style. This presents a clean and attractive street view. The partial exposure of the heat cable provides for easy insertion, inspection and replacement of the cable is in compliance with the NEC (National Electrical Code) requirements. 800.411.3296 29 29

DESIGN GUIDE for HotFlashing for HotFlashing HotFlashing Panel Profiles 12-watt/ft heat cable 0.24 x 0.54 max 90 flange bend option for vertical surface flashing 0.24 Hem Flat surface for valley flashing Optional hem Vertical bend (VBxx) ption Total idth HotFlashing - Scale 2:1 Total Width: 3, 6, 10 Vertical Bend Option at 4 or 6 Standard length: 60 Profile Options Flat Flashing This profile is commonly used in the valley intersection of two adjoining roof surfaces. They can be slid under the existing shingles and secured with commercial grade adhesive. The panels can be bent or trimmed at the time of installation to clear existing nails or other obstructions. If the existing valleys have a W flashing in place, two runs of the panels are recommended. A maximum horizontal melt path of 6 to 8 from the heat cable can be expected. Right Angle Vertical Flashing These right angle flashings are used to create a melt path next to vertical walls, skylights, dormers, chimneys or other types of protrusions from the main roof surface. These areas can trap ice and snow and create hidden ice dams that need a drain path. The panels are available in 3, 6, 10 and 14 widths. For example, using a 10 total width, the vertical 90 flange bend is available at 4 to create a 6 vertical flange or at 6 to create a 4 vertical flange. Please note the total width measurement includes the horizontal and the vertical lengths. 800.411.3296 30 30

DESIGN GUIDE for HotFlashing for HotFlashing HotFlashing Harmonized Part Number Nomenclature HFLR 006 S - HAGR 060 XX REV11 HotFlashing Track Products HFLR 0015 = HotFlashing 1.5 Wide HFLR 003 = HotFlashing 3 Wide HFLR 006 = HotFlashing 6 Wide HFLR 010 = HotFlashing 10 Wide The width and length may be cut at the time of installation. Material & Color Length Options Material C = Copper, 0.021, 16oz., ½ hard S = Painted Kynar 500 Steel 0.019 A = Painted Kynar 500 Aluminum, 0.032 060 = 60 XX = No Options BTP = Build to Print (Special Order Only) Color NATC = Natural Copper (For Copper Material) Standard Colors ALMD= Almond CLRD = Colonial Red HMGR = Hemlock Green SLBL = Slate Blue BNWH = Bone White COPE = Copper Penny MNBN = Mansard Brown SLGR = Slate Gray MABL = Matte Black DKBZ = Dark Bronze MDBZ = Medium Bronze CLGR = Classic Green HAGR = Hartford Green SRTN = Sierra Tan 800.411.3296 31 31